Electrolux 9CHG584121, 9CHG584117, WHWUSFOOOO, 9CHG584115, 9CHG584116 User Manual

...
thermaline S90
ELECTRIC FRY TOP, GRILL/GRIDDLE
PLAQUE CHAUFFANTE, PLAQUE GRIL ET GRIDDLE, ÉLECTRIQUE
US INSTALLATION- AND OPERATING INSTRUCTIONS page 3 FR INSTRUCTIONS D’INSTALLATION ET D’EMPLOI page 11
Doc. 62.9676.01_UL Edition 1
01.2006
Against wall - contre une paroi
Free standing - isolé
Connections - Raccordement
Electricity - Electricité
Fig.1 INSTALLATION DRAWINGS - PLANS D'INSTALLATION
CONTENTS
I. GENERAL INFORMATION................................................................................................. 3
II. INSTALLATION INSTRUCTIONS .......................................................................................4
III. OPERATING INSTRUCTIONS ............................................................................................8
SOMMAIRE
IV. INSTRUCTIONS GÉNÉRALES .........................................................................................11
V. INSTRUCTIONS RELATIVES À L'INSTALLATION .........................................................12
VI. INSTRUCTIONS DE FONCTIONNEMENT .......................................................................16
62.9676.01_UL Page 1
Page 2 62.9676.01_UL

I . GENERAL INFORMATION

GENERAL INFORMATION

1. INSTRUCTIONS FOR SAFETY AND USE

1.1 INSTALLATION AND INITIAL OPERATION
S The installation, adjustment and initial
operation of the appliance must be properly carried out in accordance with the manufacturer's instructions and may only be done by an authorised specialist.
S Installations for the supply of electricity must be
carried out by qualified installers in accordance with the specific national and local regulations. They bear the responsibility.
S The appliance must not be placed in operation
until the user has become familiar with its operation. The operating instructions and the related safety precautions must be followed precisely. Follow strictly the attention and warning label indications on the appliances.
1.2 OWNER'S OBLIGATIONS
S The manager is responsible for ensuring that
all components relevant for safety are in perfect working order at all times. The operating condition of these components must be examined by an authorized technician at least once a year and any defects remedied if required.
S The operator of this appliance is responsible
for total observation of the national regulations concerning operating safety.
S Remain the manual for future reference.
1.3 USE AS PRESCRIBED
S Closed containers (jars, cans, bottles, tubes,
etc.) must not be heated owing to the danger of bursting and injuries.
1.5 AFTER-SALES SERVICE AND REPAIR
S In the event of a permanent fault which
interferes with operation, the appliance must be switched off and disconnected from the power supply.
S To perform maintenance and repairs contact
the factory, the factory representative or a local service company.
S Repair, maintenance work and other
adjustments are only to be carried out by an authorized specialist. The valid local and national regulations must be observed. This applies especially to safety and control elements. Parts requiring replacement are only to be replaced by original spare parts. A service contract is recommended.
S Cleaning and maintenance must be done only
when the heating surfaces are cold. Do not use inflammable liquids to clean the appliance.
S An obligatory service check is required
annually.

2. TECHNICAL DATA

inch
31.5
35.4
35.4
Width Depth
Height
PNC
Appliances
9CHG584114 WHWURFOOOO 208
9CHG584115 WHXURFOOOO 240
9CHG584116 WHWUSFOOOO 208 11.4
9CHG584117 WHXUSFOOOO 240
9CHG584118 WHWURAOOOO 208 11.4
9CHG584119 WHXURAOOOO 240
9CHG584120 WHWUSAOOOO 208 11.4
9CHG584121 WHXUSAOOOO 240
Appliance type
Voltage
V
mm
800 900 900
Cooking
surface
29.4“ x
25.6“ 748 x
649 mm
Power
in kW
11.4
13.2
13.2
13.2
13.2
1.4 SAFETY-CONSCIOUS WORKING
S Touching the hot plates can cause burns. S Spraying the appliance or its parts with a high-
pressure cleaning device may cause malfunctions and is not to be done.
S When putting oil, fat, water or ingredients in the
preheated hot frying pan, they may spit. - Dan­ger of burning!
S Filling quantity and temperature must be selec-
ted as appropriate. At high temperatures (above 100°C) too much liquid in the trough can lead to boiling over and spitting. - Danger
of burning!
S Overheated oil can ignite spontaneously.
Never use water to extinguish burning oil, but smother the flames with the lid or a damp cloth.
S For appliances with a downpipe, the hose
should lead into a drain opening which is cov­ered by a grating such that it cannot be kicked or tipped, or a drain gutter should run under­neath the appliance.
S Devices on wheels set up in block configuration
must be checked before each start-up whether the potential equalization is connected with the neighbour equipment. The connection may be done only by authorized technical personnel.
S Appliances on wheels must be fastened to the
building.

3. PACKAGING

All the packaging materials used are environmentally friendly. They may burnt at an incineration plant or sent for recycling.

4. TESTS / CERTIFICATES

All electrical appliances are UL 197 tested. The appliance noise level is negligibly low. The statutory
guidelines are met; the noise level is less than 70 dB (A).

5. SPECIFICATION PLATE

The specification plate (E) is located in each case inside and outside on the right of the operator panel (C) (Page 5 Fig. 5).
The serial number is marked on the type plate. The 8 digits give following information:
Y last digit of the year of production WW week of production XXXXX running number
62.9676.01_UL Page 3
INSTALLATION INSTRUCTIONS

II . INSTALLATION INSTRUCTIONS

1. INSTALLATION

The appliance is designed for connection to fixed lines. The appliances are suitable for setting up as single appliance s or as a group of appliances. They can be set up freely in the room, side by side, at the side and/or at the back against a wall.
Gaps between two appliances or appliance and sidewall should be filled with a FDA approved silico ne such as Samco RTV103.
1.1 DISTANCES
If an appliance is set up next to or against temperature-sensi­tive furniture or similar, a safety gap of approximately 6“ (15 mm) should be maintained or some form of heat insulation fit­ted.
The walls must be made up of non-combustible material like tiles or steel.
1.2 HEIGHT ADJUSTMENT
Appliance on feet: Alignme nt is carried out by screwing the
Appliance on steel plinth:
Appliance on feet.
lower foot parts in or out. Irregularities or differences in height can
be equalized by inserting one or several strips of chrome nickel steel.
D Turn the lower part of the feed to adjust the appliance high.
The feet are adjustable from 4“ to 8“ (100 to 200 mm). A high of 8“ (200 mm) can be recommended and results in an appli­ance high of 35,4“ (900 mm).
Note: Adjustment of the legs shall provide an unobstructed
clearance of minimal 6“ (150 mm) and maximal 8“ (200 mm) beneath the unit due to sanitary and stability aspects.
The lower part of the foot must not be unscrewed too far. The exposure of threads is prohibited.
1.3 ASSEMBLING TWO APPLIANCES
(2)
(1)
(1)
(2)
(2)
a
b
1
c
Fig.1 Lateral connection
(3a)
(1)
(3b)
(3)
(2)
(3c)
(3c)
The assembly kit contains three of each of the following: caged nuts (1 / Fig.1) pre-assembled on the rig ht-hand side of
the appliance, hexagonal screws M8x25 (1 / Fig.1), bolts wi th retaining rings (2 / Fig.1) and mounting links (3 / Fig.1)
D Remove the control panels from both appliances as in 2.2 D Remove the front panels from both appliances as in 2.1 D Insert the bolts with the retaining rings (2 / Fig.1) from out-
side into the guide in the right-hand connecting plate.
D Keeping the screw (3 / Fig.1) loose, turn it until it is approx-
imately 5 mm deep in the caged nut.
Positioning the appliances:
D Place the appliances next to one other. D Align for position and height.
Connect the appliances:
D Push the appliances togethe r so that the bolts (1 / Fig.1)
engage in the guides of the appliance to be attached.
D Fit the mounting link (3 / Fig.1) into the inside of the second
appliance's left connecting plate.
D Tighten the screws.
Note
If required, the caged nuts can also be fitted on the other side of the appliance.
The connection of two appliances (Fig 1c, arrow) must co rre­spond to the hygienic regulations respective the standard NSF/ANSI 4. All resulting joints and seams in a splash zone shall be sealed and smooth.
Page 4 62.9676.01_UL
Loading...
+ 13 hidden pages