ElectrIQ CD12LE, CD20LE, CD12P User Manual

USER MANUAL
PREMIUM LOW ENERGY COMPRESSOR
DEHUMIDIFIER WITH DIGITAL HUMIDISTAT
AND AIR PURIFIER
CD12LE – 12 litres per day
CD20LE – 20 litres per day
Thank you for choosing electriQ.
Dehumidier and keep it safe for future reference
Visit our page www.electriQ.co.uk for our entire range of Intelligent Electricals
CONTENTS
SAFETY INSTRUCTIONS 2
INSTALLATION 5
PARTS 6
CONTROL PANEL 7
QUICK REFERENCE GUIDE 8
POSITIONING 11
WATER DRAINAGE 12
CARE AND MAINTENANCE 12
TROUBLESHOOTING 14
TECHNICAL DATA 15
Carefully read the instructions before operating the unit This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and
may cause re, electrical shocks or other injury to user or property.
Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical supply have it
checked and if necessary, modied by a qualied electrician. This dehumidifier has been tested and is safe to use. However, as with any
electrical appliance - use it with care.
Disconnect the power before dismantling, assembling or cleaning.
Avoid touching any moving parts of the appliance.
Never insert ngers, pencils or any other objects though the guard
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision
or instruction concerning the use of the appliance by a person responsible for their safety. Do not leave children unsupervised with this appliance. Do not clean the unit by spraying it or immersing it in water.
Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualied electrician. Never operate this appliance if the cord, power adapter or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.
A damaged power supply cord should be replaced by the manufacturer or a
qualied electrician in order to avoid a hazard. Any service other than regular cleaning or lter replacement should be performed
by an authorized service representative. Failure to comply could result in a voided warranty. Do not use the appliance for any purpose other than its intended use.
Do not tilt the unit while in use. The unit is design to work only in vertical position. This dehumidifier must always be stored and transported upright, otherwise
irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
Avoid restarting the dehumidier unless 5 minutes have passed since being turned
off. This prevents damage to the compressor. Never use the plug as a switch to start or turn off the dehumidifier. Use the provided ON/OFF switch located on the control panel. Always place the unit on a dry and stable surface. The appliance should not be installed in laundry or wet rooms where the humidity is higher than 85% RH
Do not dry laundry above the unit to prevent water entering the dehumidier. Place the laundry at least 1 meter away from your dehumidier.
IMPORTANT
SAFETY INSTRUCTIONS
02
The appliance must be placed in a room without sources of ignition (for example: open ames, an operating gas appliance or an operating electric heater).
R290 refrigerant gas complies with European environmental directives. R290 has a low GWP (Global Warming Potential) of 3. The CD12LE contains about 60g of R290 refrigerant gas. The CD20LE contains about 75g of R290 refrigerant gas. Do not use or store the CD20LE in an unventilated space with an area smaller than 4.1m2 per unit. Do not use or store the CD12LE in an unventilated space with an area smaller than 2.6m2 per unit.
If the appliance is installed, used or stored in an unventilated room, the room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of re or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
Refrigerant gas may be odourless.
Do not use the product and contact the retailer for advice, if damage has occurred
to the unit which may have compromised the refrigerant system. Any repairs or maintenance must only be carried out on the unit by a suitably
qualied engineer. Before opening and servicing the unit the authorized engineer
must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized. The refrigerant system should not be perforated or punctured.
Do not place the unit next to heat sources (e.g. electrical res, replaces, etc.) Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its internals and increases the risks of operating it. Do not store or use gasoline, petrol, paint, solvents or other ammable vapours or liquids in the vicinity of this dehumidier or any other appliance. This dehumidier must not be used in spaces where there is a high concentration of gases, solvent or other volatile organic compounds; in very dusty environments; in any domestic, commercial or industrial environment where the air composition is ammable.
Do not cover or restrict the airow from the outlet or inlet grills. Do not operate and
follow troubleshoot procedure if the self-opening louvers do not open on power on.
For maximum performance the minimum distance from a wall or objects should be
20 cm
Keep the lters or grills of the unit clean. Under normal conditions, lters or grills should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality. Vacuum both mesh and optional carbon lters and wash the mesh lters with hot soapy water and dry them before placing them back in the unit.
ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS
03