ElectrIQ AIRCUBE 10DLX User Manual

Page 1 of 13
AIRCUBE
AIRCUBEAIRCUBE
AIRCUBE® 10DLX
10DLX10DLX
10DLX
PORTABLE AIR
PORTABLE AIR PORTABLE AIR
PORTABLE AIR CONDITIONER
CONDITIONERCONDITIONER
CONDITIONER WITH HEATPUMP
WITH HEATPUMPWITH HEATPUMP
WITH HEATPUMP
USER MANUAL
Thank you for choosing ElectrIQ.
Please read this user manual before using this innovative Air Conditioner and keep it
safe for future reference.
Visit our page www.electrIQ.co.uk for our entire range of Intelligent Electricals
Page 2 of 13
CONTENTS
1..SAFETY INSTRUCTIONS ………………………………….. 3
2..FEATURES AND PARTS LIST ………………………….... 4
3..INSTALLATION …………………………………. …………. 6
4..OPERATION AND SETTINGS …………………………….. 7
5..WATER-DRAINAGE …………………………………………. 9
6..MAINTENANCE ……………………………………………… 10
7..TROUBLE SHOOTING …………………………………. …. 11
8..APPENDIX ……………………………………………………. 12
Page 3 of 13
SAFETY INSTRUCTIONS
Important!
Carefully read the instructions before operating the unt. Note: This AC is for indoor use only.
Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
Installation must be in accordance with regulations of the country where the unit is used.
If you are in any doubt about the suitability of your electrical supply have it checked and, if
necessary, modified by a qualified electrician.
This air conditioner has been tested and is safe to use. However, as with any electrical appliances - use it with care.
Disconnect the power plug from socket before dismantling, assembling or cleaning.
Avoid touching any moving parts of the appliance.
Never insert fingers, pencils or any other objects though the guard
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Do not leave children unsupervised with this appliance.
Do not clean the unit by spraying it or immersing it in water.
Never connect the unit to an electrical outlet using an extension cord. If an outlet is not
available, one should be installed by a qualified electrician.
Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp object/edges.
A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty.
Do not use the appliance for any other purposes than its intended use.
The air conditioner unit must always be stored and transported upright, otherwise
irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off. This prevents damage to the compressor.
Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF switch located on the control panel.
Always place the unit on a dry and stable surface.
The appliance should not be installed in laundry or wet rooms
Energy Saving and Unit Safety Protection Tips
Do not cover or restrict the airflow from the outlet or inlet grills.
For maximum performance the minimum distance from a wall or objects should be 50cm. Unit
is fitted with thermal cut off sensor that will prevent overheating
Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality.
For the initial start-up set the fan speed to maximum and the thermostat to 4-5 degrees lower than the current temperature. After, set the fan switch to low and set the thermostat to your desired setting.
To protect the unit we recommend not using the cooling function when the ambient temperature is higher than 35°C.
To protect the unit we recommend not using the heating function when the ambient temperature is lower than 7°C. Use electrical or alternative heating to raise the room temperature to 10°C than start the air conditioner in heat mode and set it to the desired temperature. Heating by heat pump will take longer but is cheaper than any other form of heating and ideal for maintaining room temperature constant.
Page 4 of 13
FEATURES AND PARTS LIST
1. Features
Part of ElectrIQ AirCube® range of Intelligent Air Conditioning products
Cooling, Heating and Dehumidifying for all around the year use
Improves comfort and indoor air quality
Self-evaporative system - no external water tank needed
Compact, designer inspired luxury model
Digital Control Panel with side vents to prevent dust and dirt entering the machine.
Bright LED screen, indicates temperature and error codes
Remote control that can be stored in slot at on the side of unit after use.
The hot air outlet is positioned high on the unit – this allows for improved performance
with the use of a short hose
On/Off timer function – allows you to choose when the unit operates both in air
conditioning or dehumidifying mode
Advanced Compressor protection technology
Recessed castors for improved portability
2. Parts list
::::
1. Control panel 8. Bottom drain port
2. Remote control sensor 9. Remote control slide in slot
3. Cold air outlet 10. Hot air outlet hose mount
4. Cold air outlet hose mount 11. Hot air outlet
5. Exhaust hose connector 12. Evaporator filter
6. Exhaust hose 13. Cool air inlet
7. Hot air inlet 14. Secondary drain port
Loading...
+ 9 hidden pages