PERRY ELECTRIC Srl
Via Milanese, 11
RECESS SERIES ELECTRONIC
22070 VENIANO (CO)
ITALY www.perry.it
THERMOSTATS MODULE - H 45 mm
Models with differential ON/OFF intervention and luminous charge inserted signal
1TITE302/MC - Electronic thermostat with On-Off-Antifreeze control and input for night reduction
1TITE304/MC - Electronic thermostat for night reduction control on board
1TITE305/MC - Electronic thermostat with remote thermostat for floor heating;
night reduction control on board
TECHNICAL DATA
Supply voltage: 230 V~ 50 ÷ 60 Hz
Type of action, disconnect and device: 1 / B / Electronic
Type of output relay with changeover contact NO / COM / NC:
Output connection (load): 2 or 3 conductors
Wire section at terminals:
Insulation type: Class II
Protection degree: IP 30
Pollution:
Temperature adjustment range
(excluding 1TITE305/MC
Temperature adjustment range
(only 1TITE305/MC
ERP Energy classification:
Thermal gradient: max 1K/15 min.
Differential operation:
Precision of reading ± 1 °C
Operating temperature limits: 0 °C ÷ + 50 °C
):
):
Reference standard for CE mark: LVD EN60730-2-9
voltage free - 8(2)A / 250 V~
min. mm0,752- max. 2,5 mm
normal
from+5°Cto+30°C
from 0°Cto+60°C
()limitable
()limitable
ErP: Class I; 1% Reg. EU 811/2013
T=0,7°C
EMC EN60730-2-9
PERFORMANCE DATA (according to model)
Night reduction control on board (1TITE and 1TITE304/MC 305/MC)
Night reduction temperature (referred to the set): - 4°C (all models excluding 1TITE305/MC)
Antifreeze temperature (only 1TITE302/MC): +5 °C fix
Temperature set lock (all models): mechanical with “range disc” (supplied)
External probe (only 1TITE305/MC): probe with 4 m of cable (supplied)
Luminous signals (all models): LED showing charge inserted/disengaged
remote control ( 302/MC)1TITE
- 9 °C ( 305/MC)1TITE
PE - DETIPE013 02/18
PE - DETIPE014EN 02/20
DISPOSAL OF OLDELECTRICAL & ELECTRONIC EQUIPMENT
This symbol on the product or its packaging to indicates that this product shall not be
treated ashousehold waste.
Instead, it shall be handed over to the applicable collection point for the recycling of
electrical andelectronic equipment,such as forexample:
- salespoints, incase you buya newand similar product
- localcollection points(waste collection centre,local recyclingcenter, etc...).
By ensuring this product is disposed of correctly, you will help prevent potential negative
consequence forthe environment and human health,which could otherwisebe caused by
inappropriate wastehanding ofthis product.
The recycling of materials will help to conserve natural resources. For more detailed
information aboutrecycling ofthis product, please contact your local cityoffice, yourhouse
hold wastedisposal serviceor the shopwhere youpurchased the product.
Ins allation
t
and user
in tructions
s
Read this manual carefully before using the
product as it provides important guidelines
regarding safety,installation and use.
The manual must be preserved with care for
future reference.
English
2
INSTALLATION EXAMPLES
5
1010
1515
0
303
5
2020
252
5
10
5
151
3030
5
2020
5
1010
1515
0
303
2020
2525
h 1,5 m
Install the thermostat at a height of 1,5 m ÷ 1,7 m from the floor, far from heat sources, air vents,
doors or windows and anything else that could affect its operation.
5
101
0
5
151
3030
2020
2525
AB
252
C
C
DIMENSIONS
SIGNALS AND CONTROLS (according to model)
Load status signal LED:
alight = load inserted
Knob with temperature scale:
DD
Examples of installation in heating systems
with a thermostat that controls:
A) Wall mounted boiler
B) Burner
C) Circulation pump or Motorized solenoid valve
D) Area solenoid valve
N.B.: the examples contained in this documentation are in principle.
5 °C ÷ 30 °C TE30 /MC1TI 2
0 °C ÷ 60 °C TE305/MC1TI
Reference index for temperature setting
Selector for controlling work mode, according to model:
1TITE302/MC 1TITE304/MC 1TITE305/MC -
--0
I
(Alight - OFF - Antifreeze)
--0
(Winter - OFF - Nighttime economy)
(Winter - OFF - Nighttime economy)
--0
"
1TITE304/MC
SAFETY PRECAUTIONS
Important: the installation and electrical connection of the devices and appliances must be implemented by person with electrotechnical expertise only and in conformity with current laws and
regulations. he manufacturer declines anyliability for the use ofproducts subjectto special environmental and/or installationstandards.T
Attention: before starting any operations on the device, disconnect the 230V~ mains power supply
This appliance must be intended only for the use for which it was built. Any other use must be considered improper and dangerous.
The thermostat isnot intended foruse bypersons (including children)with reduced physical, sensory or mental capabilities, orby those with a lackof experience and knowledge ofthe instructions,
unless theyare supervisedor havereceived the necessary instructionsconcerning use of thedevice by a person responsiblefor theirsafety.
Children shouldbe supervisedto ensurethat they do not playwith thedevice.
COMPATIBILITY TO THE MOST COMMON RESIDENTIAL SERIES PLATES
IMPORTANT: for the assembly procedure of the thermostat with the chosen
residential plate, follow instructions contained in the specific compatibility
sheet contained in the package.
INSTALLATION INSTRUCTIONS
1-INSTALLATION EXAMPLE
Make sure to remove the 230V mains supply before proceeding with the installation
COMPATIBILITY TO THE MOST COMMON RESIDENTIAL SERIES PLATES
IMPORTANT: for the assembly procedure of the thermostat with the
chosen residential plate, also follow instructions contained in the
specific compatibility sheet contained in the package.
Thermostat body
Front
Apply the chosen front
(4 lateral blocking teeth)
AB
E
Insert the knob
IMPORTANT!
Fasten the chosen frame
from the type 503 recess box
Make the electrical connections
Left ledge
Correct knob
position
C
Insert the thermostat
into the frame until it is blocked
Attention to the position of the
insertion pins of the ledges
F
Apply the two ledges to the frame
(if required based on the plate type)
Right ledge
Set temperature lock
Apply the chosen plate
D
(only if desired)
G
Range disc
Plate
2 - WORKING FLUID MAXIMUM TEMPERATURE OF THE ENVIRONMENT LIMITATION
It is possible to preset from 16 °C to 24 °C, with 2 °C step, the maximum temperature value (excluding 1TITE305/MC).
It is possible to preset from 25 °C to 45 °C, with 5 °C step, the maximum temperature value (1TITE305/MC).
NB: the thermostat is supplied with the "range disc" preinstalled with pin in the neutral hole (no temperature limitation).
Temperature limit setting or its subsequent modification
a) Rotate the knob anti-clockwise and pull it out.
b) Take out the “temperature range” disc and reinsert it by locating the maximum desired temperature
hole over the pin placed on thermostat .
c) Reinsert the and verify at the end of the anti-clockwise limit corresponding to 5°Cknob
(0°C for 1TITE305/MC) with index, if different, re-insert the rotated by 180°.knob
(fig. 1)
16 °C (25 °C)
18 °C (30 °C)
20 °C (35 °C)
22 °C (40 °C)
24 °C (45 °C)
N.B.:
the values in parenthesis
refer to TE305/MC1TI
Index
Holes for temperature set point limitation
Range disc seat range
Pin
Rdange isc
Neutral hole
Holes
Knob
Fig. 1
2