ENGLISH
PHOTOCELL LIGHTING CONTROL WITH INTERNAL SENSOR
- Threshold adjustable from 2 to 200 LUX
- The product is supplied pre-set at 10 LUX
1 – TECHNICAL DATA
Supply voltage:
Caracteristics of the breaking device:
Example of maximum operating power:
230V~ 50 ÷ 60 Hz
Relay with NA single-pole polarized contact,
16A / 230V~
3500 W / 230V~ cos =1j
PE IC 13 03/18- DE NN0
WARNINGS!
Read this manual carefully before using the
product as it provides important guidelines
regarding safety, installation and use. The
manual must be preserved with care for future
reference.
Caution! Installation by person with
electrotechnical expertise only.
This equipment will be intended only for use for
which itwas specificallybuilt.
Before starting any operations on the device,
disconnect the 230V~mains powersupply
CFL
2300 W (23 x 100W)lamps
Maximum wire section at terminals:
Protection degree:
Photo-sensitive element:
Activation threshold:
Switch on/switch off delay:
Operating temperature limits:
Storing temperature limits:
Installation:
Reference standard for CE mark:
DISPOSAL OFOLD ELECTRICAL& ELECTRONIC EQUIPMENT
This symbol on theproduct or its packaging to indicates thatthis product shall not be treatedas household waste. Instead, it shall be
handed over to the applicable collection point for the recycling of electrical and electronic equipment. The recycling of materials will
help toconserve naturalresources.
700 W (12 lamps x 58W)
290 W (5 x 58W 35 µF)lamps
1,5 ÷ 2,5 mm²
I65P
Photodiode
2÷200 LUX adjustable
25 seconds approx.
-30 °C ÷ +60 °C
-30 °C ÷ +65 °C
For external use pole or wall mounting
LVD EN60669-2-1
EMC EN60669-2-1
max 7 lamps (7W ÷ 15W)
LED