Electric Heating Company Electric Combination Radiators Installation And Technical Manual

EHC Electric Combination Radiators
Installation and
technical manual
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. BE SURE TO OBSERVE ALL
LABELS AND WARNINGS ON THE APPLIANCE.
Unit 40, Block 5, Third Road, Blantyre Industrial Estate, Blantyre, Glasgow, G71 6NP
Tel. 01698 820533 Fax. 01698 825697
info@electric-heatingcompany.co.uk
www.electric-heatingcompany.co.uk
EHC Electric Combination Radiators – Installation and technical manual Page 2
CONTENTS
1. Safety information ......................................................... 2
2. General information....................................................... 4
3. Installation ..................................................................... 5
4. Operating instructions ................................................... 10
5. Operating safety ............................................................ 10
6. Technical data ................................................................ 13
1. Safety Information
Electrical Connections
IMPORTANT
The wires in the mains leads are coloured in accordance with the following code:
GREEN & YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
WARNING – THIS APPLIANCE MUST BE EARTHED
The installation of this appliance should be carried out by a competent electrician in accordance with I.E.E. Regulations for Electrical Equipment.
The radiator is fitted with a standard UK 3 pin plug that can be directly connected to an electrical socket. Care must be taken when connecting radiators in this way not
to overload the ring main circuit. If you are unsure contact a qualified electrician.
Alternatively the mains cable can be cut to length and connected to a suitable fused 20 amp double-pole switched spur adjacent to the radiator. Please ensure that the electricity supply is disconnected prior to using this installation method.
Each supply circuit to the radiator must incorporate a Fused 20 Amp double pole switched spur having a contact separation of at least 3mm.
EHC Electric Combination Radiators – Installation and technical manual Page 3
1. Safety Information (cont.)
Handling
This radiator is very heavy. Take adequate precautions when lifting and manoeuvring it. Always assess the load, and seek assistance with heavy or awkward loads that are beyond your capabilities.
Positioning
This radiator is very heavy. In order to maintain stability and to ensure its future safety in use, it is essential that the radiator is FIXED SOUNDLY TO A WALL and that the brackets are mounted on a FIRM, LEVEL SURFACE. Castors or Feet can be purchased as an accessory. Care should be taken to avoid irregular surfaces.
It is important that the following instructions are strictly followed.
Keep the following minimum safety distances to avoid fire risk due to high surface temperatures of the appliance during heating cycles:
Lateral heating walls – masonry ......................................................50 mm
Lateral heating walls – combustible matter ..................................100 mm
Heating walls above floor ................................................................80 mm
Cover plate – combustible covering installed on top of it ...........150 mm
Cover plate – non-combustible covering installed on top of it ...100 mm
Please note that our IPX4 rated models should be used in bathrooms.
Portable radiators must not be fitted in bathrooms or wet areas.
CAUTION – This radiator must not be located below a fixed socket outlet.
DO NOT POSITION under windows where curtains may contact the radiator.
DO NOT PLACE THE APPLIANCE in the vicinity of a swimming pool.
Installation
It is important that the fixing device chosen is appropriate to the wall material to which the radiator is being fixed. Some modern internal building materials are very low density block and require specialised fixing devices to provide a safe, secure installation.
(see section 3, page 6)
Ongoing safety
CAUTION – If during any reassembly of the radiator, a part of the thermal insulation shows damage or deterioration which may impair safety, it should be replaced with an identical part.
CAUTION – In order to avoid overheating, do not cover the radiator.
DO NOT COVER OR OBSTRUCT the surfaces of the appliance.
DO NOT PLACE OBJECTS in contact with the radiator.
EHC Electric Combination Radiators – Installation and technical manual Page 4
2. General Information
EHC Combination Electric radiators have been designed using the latest technology to create an elegant solution for all hard to heat situations. They can be installed in almost any location apart from the safety restrictions noted in this manual.
The range has been developed to provide a flexible solution for electric heating in Domestic properties, Conservatories, Holiday homes, Offices and any other temporary heating situation.
Our unique patented ’Magmatic’ heating tablets provide the heat source for your new radiator. Whilst the radiator is classed as a 100% efficient Direct Acting appliance, the heating tablets provide partial storage to prolong your heating comfort and to reduce running costs. The radiator has a robust body which incorporates a spot welded high fin surface area to ensure that there are no contraction noises during the heating cycle. The high fin design boasts 6 times the normal radiator surface area to provide a balance of Convection and Radiant heat for your added comfort.
The radiators can be simply plugged in to a Standard socket or Hard wired to an existing spur connection. The range has the flexability of being Wall mounted or free standing on Castors or Feet.
For added versatility we can supply Conservatory radiators which are also ideal for use below windows with low sills.
All our standard model sizes are supplied with a TEI 1 manual room thermostat. For a fully controllable central heating system, the radiators can be installed with our EHC Control Box, Single Channel Programmer and Room Thermostat to comply with the latest Building Regulations.
In addition to the above we also supply Radio Frequency radiators which provide all the benefits of the standard version however the control wiring is eliminated. These models can be controlled by our TEI 6 and TEI 8 Programmers.
All EHC radiators are manufactured to the highest safety and quality Standards. Each radiator is CE Marked and carries all the necessary European Approvals. Each radiator is fully checked and tested prior to leaving the factory and as such is packed with full Quality certification.
We hope you enjoy the comfort provided by this superior product and we look forward to being of assistance to you in the future.
EHC Electric Combination Radiators – Installation and technical manual Page 5
3. Installation
Preparation
1. Before beginning, remove the radiator and parts from the box and check everything is present and correct. In addition to the radiator body, there should be a top grille, a pair of mounting brackets, four suspension hooks, a set of mounting screws/ plugs and an instruction manual.
2. Check page 3 of this manual to find the minimum clearances for your chosen location. Mark the bracket positions on the wall according to the following diagrams:
Rad. Length
(mm)
Bracket
separation
(mm)
380 680 850
980 1280 1580
220 420 580
680 1000 1200
Loading...