EXA RJ45 and NET D6
INSTALLATION GUIDE
COPYRIGHT
Electrex is a trademark of Akse S.r.l. All rights reserved.
It is forbidden to duplicate, adapt, transcript this document without Akse written
authorization, except when regulated accordingly by the Copyright Laws.
WARRANTY
This product is covered by a warranty against material and manufacturing defects for a 24
months period from the manufacturing date.
The warranty does not cover the defects that are due to:
• Negligent and improper use
• Failures caused by atmospheric hazards
• Acts of vandalism
• Wear out of materials
• Firmware upgrades
Akse reserves the right, at its discretion, to repair or substitute the faulty products
The warranty is not applicable to the products that will result defective in consequence of
a negligent and improper use or an operating procedure not contemplated in this manual.
RETURN AND REPAIR FORMALITIES
Akse accepts the return of instruments for repair only when authorized in advance. The
transport costs are at customer charge.
RE-SHIPPING OF REPAIRED PRODUCT
The terms for re-shipment of repaired products are ex-works, i.e. the transport costs are
at customer charge.
Products returned as detective but found to be perfectly working by our laboratories, will
be charged a fl at fee to account for checking and testing time irrespective of the warranty
terms.
SAFETY
This instrument was manufactured and tested in compliance with IEC 61010-1 CAT III 300V class 2 standards for operating voltages up to 300 VAC rms phase to neutral.
In order to maintain this condition and to ensure safe operation, the user must comply with
the indications and markings contained in the following instructions:
• When the instrument is received, before starting its installation, check that it is
intact and no damage occurred during transport.
• Before mounting, ensure that the instrument operating voltages and the mains
voltage are compatible then proceed with the installation.
• The instrument power supply needs no earth connection.
• The instrument is not equipped with a power supply fuse; a suitable external
protection fuse must be foreseen by the contractor.
• Maintenance and/or repair must be carried out only by qualifi ed, authorized
personnel
• If there is ever the suspicion that safe operation is no longer possible, the instrument
must be taken out of service and precautions taken against its accidental use.
• Operation is no longer safe when:
1) There is clearly visible damaged.
2) The instrument no longer functions.
3) After lengthy storage in unfavorable conditions.
4) After serious damage occurred during transport
The instruments must be installed in respect of all the local regulations.
OPERATOR SAFETY
Warning: Failure to observe the following instructions may lead to a serious danger of
death.
• During normal operation dangerous voltages can occur on instrument terminals and
on voltage and current transformers. Energized voltage and current transformers
may generate lethal voltages. Follow carefully the standard safety precautions while
carrying out any installation or service operation.
• The terminals of the instrument must not be accessible by the user after the installation.
The user should only be allowed to access the instrument front panel where the
display is located.
• Do not use the digital outputs for protection functions nor for power limitation functions.
The instrument is suitable only for secondary protection functions.
• The instrument must be protected by a breaking device capable of interrupting both
the power supply and the measurement terminals. It must be easily reachable by the
operator and well identifi ed as instrument cut-off device.
• The instrument and its connections must be carefully protected against short-circuit.
Precautions: Failure to respect the following instructions may irreversibly damage to the
instrument.
• The outputs and the options operate at low voltage level; they cannot be powered by
any unspecifi ed external voltage.
• The application of currents not compatible with the current inputs levels will damage
to the instrument.
Further documentation may be downloaded from our web site www.electrex.it.
This document is owned by company AKSE that reserves all rights.
DECLARATION OF CONFORMITY
Akse hereby declares that its range of products complies with the following directives EMC
89/336/EEC 73/23CE 93/68 CE and complies with the following product’s standard
CEI EN 61326 – IEC 61326 CEI EN 61010 – IEC 61010.
The product has been tested in the typical wiring confi guration and with peripherals
conforming to the EMC directive and the LV directive.
READINGS
Exa Net
ELECTREX
EXA NET D6
VER X.XX-XXXX
SN XXXXXX
ADDR 247
MEASURE LIST TABLE
(The parameters available vary according to instrument confi guration)
Short keypress
P P Avg Imp P Avg Exp P MD Imp P MD Exp
Q Q Avg Imp Q Avg Exp Q MD Imp Q MD Exp
S S Avg Imp S Avg Exp S MD Imp S MD Exp
Long keypress
Long keypress
Long keypress
PF
Short keypress
U L-N / f U THD L-N U L-N Min U L-N Max
U L-L / f U THD L-L U L-L Min U L-L Max
Short keypress
In I I THD I Max I AVG I MD
Short keypress
Ea Imp ∑ Ea Imp P Ea Exp ∑ Ea Exp P
Er Ind Imp ∑ Er Ind Imp P Er Ind Exp ∑ Er Ind Exp P
Er Cap Imp ∑ Er Cap Imp P Er Cap Exp ∑ Er Cap Exp P
Es Imp ∑ Es Imp P Es Exp ∑ Es Exp P
C1 Pulse ∑ C1 Pulse P
LEGEND OF PARAMETERS AND SYMBOLS
L-N Phase Neutral U Voltage
L-L Phase Phase I Current
THD Total Harmonic Distortion In Neutral current
Avg Average (rolling) value P Active Power
MD Maximum Demand Q Reactive Power
Imp Import value S Apparent Power
Exp Export value PF Power Factor
Ind Inductive Ea Active Energy
Cap Capacitive Er Reactive Energy
Min Minimum values (10 cycles time base) Es Apparent Energy
Max Maximum values (10 cycles time base) f Frequency
CNT ∑ Pulse count (total)
CNT P Pulse count (partial)
MECHANICAL CHARACTERISTICS
Case Self-extinguishing plastic material class V0
Protection degree IP40 on front panel, IP20 terminals side
Size 105 x 90 x 58 mm (6 DIN modules)
VOLTAGE INPUT
Direct insertion Up to 300 Vrms phase-neutral or 520 Vrms phase to phase
With external VT: Primary: programmable (max. 400 kV)
Secondary: programmable (max. 300 V)
Overload: 900 Vrms phase to phase for 1 sec
Aux. power supply 85/265Vac +/- 10% 50/60Hz
Self consumption: < 2 watt
MODELS
PFNE6-11519-110 EXA NET D6 WEB 85÷265V 1DI 2DO
ENERGY ANALYZER & WEB DATA MANAGER
PFNE6-11509-110 EXA NET D6 WEB 85÷265V
ENERGY ANALYZER & WEB DATA MANAGER
PFNE6-11W09-110 EXA NET WI-FI D6 WEB 85÷265
ENERGY ANALYZER & WEB DATA MANAGER
PFNE6-11A09-110 EXA NET WI-FI EDA D6 WEB 85÷265
ENERGY ANALYZER & WEB DATA MANAGER
PFNE6-11709-0M0 EXA RJ45 D6 85÷265V
ENERGY ANALYZER & DATA MANAGER
PFNE6-11A09-0M0 EXA RJ45 WI-FI EDA D6 WEB 85÷265V
ENERGY ANALYZER & WEB DATA MANAGER
Keep pressed for 2
seconds to display:
- Type of instrument
- Firmware version
- Serial number
- RS485 address
Ea Imp ∑
Fase
Er Ind Imp ∑
Fase
![](/html/da/daa3/daa30998de5a4b78523a3cf7de76b6d19f208dec37ad7c54660a4f373b35327a/bg2.png)
DESCRIPTION OF KEYS
Short keypress Long keypress
Confi rm parameter Setup confi rmation
Modify parameter
Modify parameter
Go to previous value Go to previous page
Go to next value Go to next page
Exit without saving the confi guration
MEASURES
On “MEAS” page are displayed the main measures of the device (voltage, current, power,
energy, etc.).
ELECTREX
EXA NET D6
VER X.XX-XXXX
SN XXXXXX
ADDR 247
SET
RESET
MEAS
HARM
PAGE
HARMONICS
On “HARM” page are displayed the harmonics (from 2
ELECTREX
EXA NET D6
VER X.XX-XXXX
SN XXXXXX
ADDR 247
Select measure (U1N, U2N, U3N, I1, I2, I3)
Select harmonic (from H2 to H32 - value in %)
Exit without saving the confi guration
RESET
MEAS
HARM
PAGE
STAT
nd
to the 32nd) for voltage and current.
U
H
1N
0.0 %
2
PAGE
In development
ELECTREX
EXA NET D6
VER X.XX-XXXX
SN XXXXXX
ADDR 247
MEAS
HARM
PAGE
STAT
SET
STAT
The “STAT” page shows the assigned IP address of the LAN and WI-FI port (if present)
ELECTREX
EXA NET D6
VER X.XX-XXXX
SN XXXXXX
ADDR 247
HARM
PAGE
STAT
SET
RESET
ETH
ETH
192.168.027.001
WIFI
192.168.026.001
RESET
The “RESET” page allows to reset the total (TOT) and partial (PAR) energy counters, the
minimum and maximum values (MAX) and the historical maximum values (MD).
RESET
ELECTREX
EXA NET D6
VER X.XX-XXXX
SN XXXXXX
ADDR 247
PASSWORD REQUEST 0000 ... 9999 0000
COUNTERS
CHANGE PWD
TOT N, Y
PAR N, Y
MAX N, Y
MD N, Y
COUNTERS
TOT
N
PAR
N
MAX
N
MD
N
PWD 0000...9999 0000
STAT
SET
RESET
MEAS
HARM
DEVICE SETUP
ELECTREX
EXA NET D6
VER X.XX-XXXX
SN XXXXXX
ADDR 247
SETUP SEQUENCE
PAGE PARAMETERS VALUES AVAILABLE DEFAULT
PASSWORD REQUEST 0000 ... 9999 0000
NET Note n.4
ETH Note n.5
WIFI Note n.5
LCD Note n.3
CHANGE PWD
MEAS1 Note n.1
MEAS2 Note n.2
RS485-1
RS485-2
DEF ETH, WIFI ETH
ETH N, Y Y
WIFI N, Y Y
NET
DEF
ETH
ETH
Y
WIFI
Y
DHCP N, Y N
IP xxx.xxx.xxx.xxx 192.168.027.001
NETM xxx.xxx.xxx.xxx 255.255.255.000
GWAY xxx.xxx.xxx.xxx 127.000.000.001
ETH
DHCP
N
IP
192.168.027.001
NETM
255.255.255.000
GWAY
127.000.000.001
DHCP N, Y N
IP xxx.xxx.xxx.xxx 192.168.026.001
NETM xxx.xxx.xxx.xxx 255.255.255.000
GWAY xxx.xxx.xxx.xxx 127.000.000.001
WIFI
DHCP
N
IP
192.168.026.001
NETM
255.255.255.000
GWAY
127.000.000.001
DIM DISABLE, ENABLE DISABLE
TIME 1...90 (sec) 3
LIGHT 300...1000 500
PULSE DISABLE, ENABLE ENABLE
LCD
DIM
DISABLE
TIME
3
LIGHT
0500
PULSE
ENABLE
PWD 0000...9999 0000
NET 3PH-4W, 2PH-2W, 1PH-2W, 3PH-3W-2C 3P-4W
CT 1...10000 / 1...5 5/5
VT 1...400000 / 1...300 1/1
I AVG 1...60 (MINUTES) 8
P AVG 1...60 (MINUTES) 15
MODE SLAVE, MASTER SLAVE
TOUT 100...10000 (ms) 1000
RETR 0...9 2
ADDR 1 ... 247 27
Swap None, B = byte, W = word, D = doubleword NONE
COM1 2400, 4800, 9600, 19200, 38400 38400
Data Bit 5...8 8
Parity N = none, E = even, O = odd N
Stop Bit 1 or 2 2
ST (Silent Time) 0...5000 (ms) 100
IMP / EXP EXP
MEAS1
NET
3P-4W / EXP
CT
00005 / 5
VT
000001 / 001
MEAS2
AVG
I
AVG815
P
RS485-1
MODE
SLAVE
TOUT
01000
RETR
2
RS485-2
ADDR
247 /
COM1
38400 / 8
COM2
N / 2
ST
0100
PAGE
STAT
SET
RESET
MEAS