11-1
TROUBLESHOOTING
Revision Y05-01Service Manual - MOBILE Series
11. TROUBLESHOOTING
CONNECT THE AIR CONDITIONER TO
POWER SUPPLY.
DOES THE ST ANDBY
INDICATOR LIGHT UP?
START THE UNIT BY THE REMOTE
CONTROL.
START THE UNIT BY THE
ON UNIT CONTROL.
DOES THE SOPERATING
INDICATOR LIGHT UP?
IS THE CONTROLS SET
PROPERLY?
DOES THE
SOPERATING
INDIC ATOR LIGHT
UP?
IS THERE CO RRECT
VOLTAGE BETWEEN THE
LINE AND NEUT RAL
TERMINALS ON THE MAIN
P.C.B?
REPLACE MAIN P.C.B OR DISPLAY P.C.B
DOES THE OPE RATION
INDICATORS LIGHT UP
WHEN STARTING FROM ON
UNIT PANEL CNTROL.
IS THERE VO LTAGE BETWEEN THE
CONDENSATE PUMP TERMINALS ON
THE MAIN P.C.B?
IF LOW OR NO VOLTAGE, REPAIR POWER
SUPPLY.
REPLACE BATTERIES OR RESET THE
REMOTE C ONTROL, OR REPLACE P.C.B.
REPLACE MAIN P.C.B OR DISPLAY P.C.B
SET THE REM OTE CONTROL
DOES THE CO NDENSATE
SYSTEM FUNCTION
CORRECTLY?
REPLACE MAIN P.C.B
IS THERE VOLTAGE BETWEEN THE
CONDENSATE PUM P TERMINALS ON
THE MAIN P.C.B?
DOES THE CO NDENSATE FLOAT OR
FLOAT SWITCH FUNCTIONS
PROPERLY?
REPAIR OR REPLACE FLOAT OR M ICRO
SWITCH
REPAIR WATER TUBING OR REPLACE
PUMP
CHECK ELECTRIC AL WIRING OR
REPLACE CAPACIT OR OR MOTOR
RESISTOR OR FAN.
DOES THE INDOO R FAN
FUNCTION CORRECTLY ?
REPLACE MAIN P.C.B
IS THERE VO LTAGE ON THE TPUMP
TERMINALS ?
IS THERE VOLTAG E BETWEEN THE
TERMINALS ON THE MAIN P.C.B?
IS THERE VOLTAGE BETWEEN
INDOOR FAN TE RMINALS ON THE
MAIN P.C.B?
REPLACE CAPACITOR OR O UTDOOR FAN
OR PUMP
IF NO VOLTAG E REPLACE MAIN P .C.B - IF
LOW VOLTAGE REPAI R PO WER S UPPLY.
REPLACE CAPACI TOR OR OVER LOAD
PROTECTOR O R COMPRESOR.
DOES THE OUTDOOR FAN
OR OUTDOOR
CONDENSATE P UMP
FUNCTION CORRECTLY ?
DOES THE OVER
FLOW SWI TCH
FUNCTION
CORRECTLY?
DOES THE COMPRESSOR
START UP ( CHECK WITH
AMPMETE R)
REPAIR ELECTRI CAL WIRING
IS THERE C ORRECT VOLTAGE
(AT START) BETWEE N THE
COMPRES SOR TERMINALS ON THE
MAIN P.C.B?
IS THERE C ORRECT VOLTAGE
(AT START) ETWEEN COMPRESSOR
TERMINALS ?
DOES THE
REFRIGERATION SYSTEM
FUNCTION CORE CTLY FOR
COOOLING AND HEATING
*?(CHECK WITH
AMPMETER AND OR
PRESSURE GUAGES OR
SURFACE THERMOMETER
CHECK FOR LEAKS O R TUBING RESTRICTION,
REPAIR REFRIGERATION SYSTEM AND
CHARGE REFRIG ERANT IF NECESSARY.
CHECK IF 4-WAY REVE RSING VALVE GETS
POWER (FOR HEATI NG) OR IS DISCONNECTE D
(FOR COOLING), IF VALVE DOES NOT
FUNCTION REPAIR WITH ASSOCIATED
TUBING .
NORMAL
CHECK AND REP AIR ELECTRICAL WIRING
REPLACE MAIN P.C.B
CHECK AND REP AIR ELECTRICAL WIRING
DRAIN THE COND ENSATE OR REPAIR
FLOAT OR OVERFLOW SWITCH.
No Yes
No
No
No
No
Yes
No
No
Yes
Yes
No
No
No
No
No
No
No
Yes
No
No
No
IS THERE VOLTAGE O N THE
TERMINALS BL OCK OF THE
OUTDOOR SECTION?
Yes
No
Yes
Yes
Yes
No
Yes
MOBILE SP LIT - TROUBLE SHOOTIN G CONTRO LS AND REFRIGERATION
Yes
Yes
Yes
Yes
Yes
* FOR HEAT PUMP MODELS
NOTE: The Standby indicator is not in use for the portable units.