Electra evolution User Manual

Page 1
KIT VIDEO DOOR PHONE evolution 2 families
Call from the Outdoor panel keys; Possibility to see on the Terminal's display the person calling ; Full duplex hands-free audio communication; Command of the access gate/door opening from the indoor Terminal ; Video and audio monitoring of the entrance of the property, by the inhabitant;
.UTP CAT 5e (AWG 24) cable required
Harry Johnston
Oliver Thompson
USER MANUAL
EN
Page 2
02
1 K IT COMPONEN TS
Outdoor panel
1 pc.
294 × 144 × 53 mm
Indoor terminal
2 pcs.
212 × 96 × 30 mm
Supply control unit
1 pc.
130 × 141 × 73 mm
Access tag
10 pcs.
35 x 62 x 7 mm
Video connection box
1 pc.
100 × 71 × 60
Supply tension of the system (supply of the control unit)
Video communication
230 V±10% / 50 Hz
0,4A AC
Audio communication
Full-duplex
Data communication
Digital
Analog video signal
Maximum power expenditure from the 230 V AC network
2 TECHNICAL FEATURES OF THE SYSTEM
Supply tension
12,0 ... 14,3 V DC(stabilized)
Steerable video camera module
- CCD, 1/3”, 573(H) x 597(V) pixel resolution; 420 TV Lines;
- angle of visualization: 96° horizontal, 45° vertical;
- video signal: 1Vvv/75 PAL;
- presence of video camera – 1 RED LED, intermittently on;
- left-right rotation angle: ± 25° 13 LED's = 850 nm; 7mW/sr per LED radiated
luminous intensity
Infrared illumination
2.1 Technical features of the Outdoor video panel
Harry Johnston
Oliver Thompson
Page 3
03
EN
2.2 Technical features of the video Terminal
Supply tension
12,0 ... 14,3 V DC(stabilized)
Keyboard
Permanent RED signaling of the VOLUME key if the terminal is turned off.
Adjustments
Audio communication volume: MAXIMUM LEVEL – MEDIUM LEVEL – TURNED OFF
- Image characteristics: luminosity, chrominance, video impedance adjustment
TOUCH type,4 keys Backlit on touch
3.5” or 2.4” LEC, TFT, resolution: 320 x RGB x 240; Display Up/down/right/left visibility angle: 10/35/50/50
Display
Range of transport and storage temperatures
- 33°C ... + 55°C
Dimensions
Weight
0,4 kg
212 x 96 x 30 mm
Operating temperature range
0°C ... + 45°C
Case
ABS Glass screen, 3 mm thick
Mounting
Surface
Casing protection level (IP)
IP31
Display of the inhabitant's name
Case
Aluminum profile painted in electrostatic field; Secured glass screen, 8 mm thick
Mounting
Flush
Keyboard
TOUCH type, permanently backlit
Casing protection level (IP)
IP44
Operating temperature range
- 30° C ... + 60°C
Transport and storage temperature range
- 33° C ... + 55° C
Dimensions
294 x 144 x 53 mm
Weight
1,52 kg
Backlit name space
Page 4
04
2.3 Technical features of the Supply control unit
Supply tension
+14V - GND : +14V DC (stabilized)/ 2A DC
+ Uv GND : +14V DC -
Vcam
GND : +12V DC -
(stabilized)/ 0.5A DC
(stabilized) / 0.4A DC
Generated power tensions/ power capability
Case
Mounting
Fireproof ABS
- On DIN rail: TH 35 x 15 or 35 x 7,5 in compliance with DIN46277-3, EN50022, IEC60715
- Surface: with A3,5 x 32 plastic screws and ø 6 mm pins
Casing protection level
Operating temperature range
IP31
0°C ... + 45°C
Transport and storage temperature range
Dimensions
Weight
- 33°C ... + 55°C
130 x 141 x 73 mm
0,4 kg
230V±10%/50Hz
Outputs (derivations)
-On DIN rail: TH 35 x 15 or 35 x 7,5 in compliance with DIN46277-3, EN50022, IEC60715
-Surface: with plastic screws and pins
2
Case
ABS
Mounting
0,21 kg
100 x 71 x 60 mm
Casing protection level (IP)
IP31
Operating temperature range
0° C ... + 45° C
Range of transport and storage temperatures
- 33° C ... + 55° C
Dimensions
Weight
Main input – output
1
2.5 Technical features of the Video connection box
Functioning frequency
125kHz
2.5 Technical features of the Access tag
Page 5
3 B LOCK D IAGRAM OF THE SY STEM
Main
terminal
6
/
6
/
Additional terminal 1
From the
video
connection
box
All additional products are sold separately.
3
/
3
/
Additional terminal 2
Additional terminal 3
Additional terminals in parallel (optional)
For more than 1 external video camera and outdoor panels in parallel, a video selection box is necessary.
05
ACC
12V/1,3Ah
(Optional)
Supply control unit
Terminal 1
Panel
OUTDOOR
INDOOR
230 V AC
/
6
/
2
/
3
/
4
/
3
/
6
Terminal 2
/
6
/
6
Video
connection
box
EN
A
ccu
mul
a
t
or
Electromagnetic
lock DC / AC
External
Video Camera
(Optional)
(Optional)
Case
Reading distance
ABS
25 mm
Casing protection level (IP)
Operating temperature range
IP 65
-30°C ... + 60°C
Range of transport and storage temperatures
Dimensions
Weight
- 33°C ... + 55°C
35 x 62 x 7 mm
7,5 g
1 out of 1.099.511.627.700
Harry Johnston
Oliver Thompson
Page 6
4.1 Recommended cables
Outdoor panel Supply control unit
UTP CAT5e (AWG24) cable for distances of maximum 70 m between the outdoor panel and the supply control unit and 250m between the outdoor panel and the video terminal. For distances greater than 250 m, please request additional information from the producer.
Video terminalVideo connection box
06
To the video
Terminal
/
6
/
6
Panel
Supply control unit
/
4
/
4
/
4
/
4
/
6
Video selection box
3.2 Block diagram of the connection of additional Outdoor panels (optional)
INSTALLATION4
To the video Terminal
Video selection box
Panel 1 Panel 2 Panel 3 Panel 4
/
6
Supply control
unit 3
Supply
control
unit 2
Supply control
unit 4
Supply control
unit 1
/
6
/
6
/
6
/
6
/
6
/
6
/
6
/
6
3.1 Block diagram of the video selection box connected with 4 additional video cameras (optional)
Harry Johnston
Oliver Thompson
Harry Johnston
Oliver Thompson
Harry Johnston
Oliver Thompson
Harry Johnston
Oliver Thompson
Harry Johnston
Oliver Thompson
Page 7
07
EN
Supply control unit
Flexible, multistrand cable, (Cu) 2 or 3 x 0,75 mm² for distances of maximum 50 m or (Cu)2 or 3 x 1 mm² for distances of maximum 100 m.
Electromagnetic lock (optional)
Supply control unit
Flexible, multistrand cable, (Cu) 3 x 0,75 mm²
230 V AC network
External video camera (optional)
UTP CAT5e (AWG24) cable for distances of maximum 200m between the external video camera and the Supply control unit. ATTENTION! Because the signal output of the video camera is on a coaxial cable, a balun adapter will be used for the passage from a coaxial cable to AWG24 cable, installed between the signal output of the video camera and the Vin2 and GNV2 inputs of the Supply control unit.
Supply control unit
è ATTENTION! The installation, the connection to the 230V/50 Hz network and
the maintenance of the Supply control unit will only be carried out by authorized personnel!
è The installation of the Supply control unit is recommended to be made within
an electrical panel.
è ATTENTION! DO NOT UNFASTEN THE FRONT LID! DANGER OF ELECTRIC
SHOCK! Only the protection lids of the connections can be unfastened.
è ATTENTION! It is mandatory for the supply of the Supply control unit from the
230 V/50Hz network to be made through two automatic fuses of 10 A (on phase and null). The connection of the F and N terminals of the Supply control unit will be made through two isolated (Cu) wires, with a section of 0,75mm²
è ATTENTION! During the installation, connection of the Supply control unit at
the 230 V/50Hz network and during service, the safety fuses from the panel must be opened. (POWER OFF)
è The connection of the (Cu) 0,75mm² grounding wire between the grounding
terminal of the electrical panel and the grounding terminal of the Supply control unit is MANDATORY.
è IMPORTANT! Before connecting the Supply control unit's supply fuses, check
the precision of the connections in the system. Check both visually, and by measurement with an ohmmeter.
è IMPORTANT! Install the protection lids of the Supply control unit's connections
before connecting the 2 supply fuses (230V/50Hz).
è PAY ATTENTION to the polarity of the terminals when connecting them to the
Supply control unit of a buffer accumulator (max. 7 Ah). The inversion of the terminals leads to the failure of the accumulator. The installation and connection of the accumulator will be carried out by authorized personnel.
è DO NOT TOUCH the wires exiting from the connectors and the terminals of the
control supply unit. Disconnect the fuses (10 A) from the supply's phase and null of the Supply control unit.
è ATTENTION! Do not supply components of the installation separately (Outdoor
panel, Terminals etc.) at tensions higher than 15V DC or directly from the network (230V/50Hz). DANGER OF ELECTRIC SHOCK and of the door phone system's destruction.
4.2 Safety instructions for installation
Page 8
4.3 Installation of the Supply control unit
DIN rail mounting
Wall mounting
RetainerDIN rail
1
2
3
A3,5 x 32 screw (2 pcs.) B2,9 x 9,5 screw (4 pcs.)Protection lid (2 pcs.)
The accumulator will be connected to the terminals of the power supply, after the commissioning of the system.
4.4 Installation of the Video connection box
Retainer
DIN rail
1
2
A3,5 x 32 screw (2 pcs.) B2,9 x 9,5 screw (4 pcs.)Protection lid (2 pcs.)
DIN rail mounting
Wall mounting
08
Frontal view Lateral view Back view
Frontal view
Lateral view
Back view
Page 9
09
The terminal will be placed at the
155cm height (recommended height)
4.5 Installation of the video Terminal
Before starting...
1
2
A3,5 x 32(35) screw
(4 pcs.)
Cable retainers – adapters
18 cm
Cable length (from the wall)
4.6 Installation of the Outdoor panel
The Outdoor panel is installed at the entrance of the property or building, on the body closest to the access door, at a height of approx. 1.7 m (upper part) from the ground, protected from rain and sunrays.
Lateral viewFrontal view Back view
The Outdoor panel keys numbering is from the bottom up, the first key meaning address 1.
EN
Page 10
10
Before starting...
The Outdoor panel is installed at the entrance to the building, on the body closest to the entrance door.
Detail of camera adjustment
Customization of the name display
Remove the plastic pad from the keyboard module
Affix a sticker with the name, cut to size, on the white space allocated to it.
Insert the pad back into the keyboard module
frontal view lateral view back view
Door phone cable
Antitheft protection
1
2 3
Tor
x
S
crew
The Torx screw must be completely screwed. Otherwise, when the system is powered, the panel emits a permanent acoustic signal. This warning function is useful if an unauthorized person tries to open the Outdoor panel. The alarm turns on immediately after one starts to unscrew the Torx. The function is turned off during the programming of the panel’s parameters.
2,5 x 8 mm screw Video camera angle adjustment
Torx Screw
for antitheft protection
Page 11
EN
PROG
CO NNECTI ON DIAGRAM
5
BROWN
GREEN
BLUE
O
RA
N
GE
External video
camera
GREEN
OR
A
NGE
BLUE
GREEN
Ac
cumula
t
or
C
ab
l
e
2 x 0,5 mm
ACC
12
V
/
7 Ah
E
lectr
i
cal p
a
nel
2
30 V
A
C/
5
0
Hz
Cabl
e
3 x 0,
75 m
m
+
1
4V
CD
IN
GND
P
Vi
n
1
G
N
V 1
GNV
2
Vi
n 2
V
c
a
m
G
ND
+
14
V
C
D
O
UT
G
ND
+U
v
V
o
ut
GN
V
B
UT
LC
LA/C
LA
AU
X
2
A
UX
1
F
N
-
A
CC
+A
C
C
.V
D
N
.
x
x
y
S
up
ply c
ont
r
o
l u
n
i
t
BROWN
BROWN
OR
ANGE
BLUE
BROWN
O
RA
N
G
E
BLUE
+1
4
V
CD
G
N
D
P
UTP
CAT 5e
(
A
WG 24)
2x
Si
g
.
10A
V
ou
t
G
N
U
GREEN
UTP
CAT
5e
(
A
WG 24)
Panel
(
O
p
t
io
n
al
)
I
NDO
OR
O
UT
D
OO
R
C
o
n
n
e
c
ted
-
w
ith
out exter
i
o
r came
r
a
N
o
t con
nect
e
d -
w
it
h exteri
or camer a
Do
o
r
be
l
l
GREEN
ORA
N
G
E
BLUE
Vi
n
G
N
V
V
o
u
t
C
D
G
ND
+
Uv
Db
l
+1
4
V
BROWN
T
er
min
a
l
1
Do
o
r
bell
GREEN
OR
ANG
E
BLUE
V
in
G
N
V
V
o
ut
CD
GN
D
+
Uv
D
bl
+
14V
BROWN
T
er
m
i
na
l 2
+
1
4V
i
n
-
ou
t
C
D
i
n-
ou
t
G
N
D
i
n
-
ou
t
GN
D
in
-
o
ut
+1
4V
1
+
2
CD
1+2
G
N
D
1
+
2
+
Uv
1
+2
Vo
u
t
1
G
N
V
o
u
t
G
NV
1
V
i
n
i
n
V
ou
t
2
G
NV
i
n
GN
V
2
+U
v
i
n-o
ut
Vo
u
t
o
ut
GN
D
1+
2
BLUE
BROWN
GREEN
ORANGE
ORANGE
BLUE
BROWN
GREEN
BLUE
BROWN
GREEN
ORANGE
Vid
e
o c
o
nec
t
io
n b
ox
UTP
CA
T
5e
(AWG
24)
(
Op
t
i
o
n
al
)
UTP
CAT
5e
(
AWG
24)
Door Opening Button
DC Electromagnetic lock
(Optional)
or
AC Electromagnetic lock
Auxiliary command
see ch. 5.3
C
onnection o
f
one e
xternal
video camera
(Optional)
(Optional)
(Optional)
UTP CAT 5e
(AWG 24)
11
Page 12
12
COMMISIONING OF THE SYSTEM
6
6.1 Description of the supply control unit
TIME:
Lock timing adjustment
The Supply control unit includes:
Protection lid for the connections
Protection lid for the connections
Front lid
LED signaling of programming / defect within the system
*PROG. : programming button
S2: existence of tension at the +Uv - GND terminals
S1: presence of tension at the +14V - GND terminals
*The kit does not require programming. This button is used only if you add additional Terminals or panels to the system.
5.1 Installation of the electromagnetic lock
Direct current (DC)
Direct current
electromagnetic lock (DC)
LC2
Cable
2 x 0.75 mm
BUT
LC
LA/C
LA
Supply control unit
LC1
Cable
2 x 0.75 mm
Alternative current
electromagnetic
lock (AC)
BUT
LC
LA/C
LA
Transformer
12 V230 V A C
Supply control unit
Alternative current (AC)
Ÿ The Supply control unit can supply a current of max. 1A
for the supply of the lock.
Ÿ The tension of +14 V DC is present on the LC terminal of
the Supply control unit.
Ÿ The connection of a lock actuating button from the
interior of the building will be made at the BUT and LC terminals of the Supply control unit.
(optional)
A C
G
ND
LA
AUX 2
A
U
X
1
Automation
Relay contact
Maximum switched current: 1.5 A
5.2 Connection of the auxiliary command (optional)
GNV 2
Vin 2
Vcam
GND
BUT
LC
LA/C
LA
AUX 2
AUX 1
5.3 Connection of one external video camera (optional)
External
video camera
V/(+)
Supply control unit
Jumper
G/(-)
Video Balun
BROWN
GREEN
BLUE
ORAN GE
BLUE
BROWN
UTP cable
CAT 5e
Not connected - with exterior camera
ORANGE
GREEN
Core Cable (for power)
If in a system you want to install more than one External video camera, you need to connect it to the Video Selection Box (VSB.4DN.BLW)
Coaxial Cable (video signal)
BNC
connectors
RCA
connectors
Braid (GND)
Central Conductor (+12V)
Maximum output current from the Supply Control Unit to power a video camera is of 0,4 A
Ÿ The Supply control unit can supply a
current of max. 1A for the supply of the lock.
PROG
Page 13
How to adjust the audition level of the video Terminal:
Through consecutive touches of the VOL UME key, different audition levels are obtained: OFF (mute) – red LED, MEDIUM white-red LE D, MAXIMUM – white LED
After checking leave the Terminal on open volume position (white on).LED
EN
13
6.3 Checking the functions and adjustments
Check anywhere in the installation, during the call and the communication, and make sure that the +14V – GND and +Uv – GND supply tension is higher than 12,0V. Check the functions of the Terminals and of the Outdoor panel: call, communication, access, audio and video monitoring. The system is adjusted by the producer in what concerns the audio part, for standard functioning conditions.
How to adjust the image characteristics on the video Terminal:
If due to the type of system (type of cable) the image on display is not qualitative, successively adjust (on the back of the Terminal) until the maximum result is obtained, in the following order:
1. Impedance adjustment;
2. Luminosity;
3. Chrominance.
Any intervention in the system will be made with the system disconnected from the 230V AC supply network (the phase and null fuses are opened) and from the accumulator (the +ACC terminal is disconnected).
6.4 Troubleshooting
Check the existence of the supply tensions with the values mentioned below, at the terminals of the Supply control unit (use a direct current voltmeter)
Ÿ Tensions measured at the terminals of the Supply control unit :
+14V – GND /13,8 … 14,3V DC +Uv – GND /13,5 … 14,3V DC
Ÿ Tensions measured at the terminals of the Outdoor panel and at the terminals of the
Terminals:
anywhere in the system
+ 14V - GND min. 12 V DC + Uv - GND min. 12 V DC
If necessary, adjust the image of the Terminal :
• In case of an unclear image, adjust:
IMPEDANCE ADJUSTMENT 6
• For color or brightness, adjust
CHROMINANCE 4
LUMINOSITY 5
Make sure that the Torx screw of the Outdoor panel is completely screwed to prevent turn ing on the anti-theft alarm.
Connect the Supply control unit to the 230 V AC network, by connecting the two automatic 10A fuses, installed on phase and null.
Optionally, connect the accumulator to the +ACC and –ACC terminals of the Supply control unit.
PAY ATTENTION to the polarity of the accumulator!
Check the precision of the connections in the system!
The +14V , GND , CD , GNV and Uv signals are common to all components of the system. The Vin and V out signals are specific to each Terminal or video camera (they are not to be
connected jointly). Any short circuit between them leads to the non-operation of the entire system.
6.2 Checking the precision of the connections in the system and the connection of the Supply control unit
Page 14
14
Short circuit in the system between +14V and GND
Control unit: S1: green S2: PRO G:
There is no image on the display, the system functions only on audio mode
3
Identify the spot of the short circuit. Remedy the defect and turn the system on.
4
The CALL does not function
Control unit: S1: green S2: green
PRO G:
Terminal:The keyboard
is functioning, it does not take the call command.
Outdoor panel:
Emits an error signal .
No CD connection at the terminals of the Terminal, or CD wire interrupted before reaching the terminals of the Terminal.
Connect the CD to the Terminal or check the continuity of the CD wire from the audio connection box to the Terminal.
The system does not Function (Supply control unit without accumulator)
2
Control unit: S1: intermittent green S2: PROG:
Identify the spot of the short circuit. Remedy the defect and turn the system on.
Control unit: S1: green S2: green
PRO G: intermittent red Terminal: The keyboard
is functioning, it does not take the call command.
Outdoor panel:
Emits an error signal
The CALL does not function
Remedy the short circuit. (by case)
Short circuit between the CD and GN D , +14V connections.
5
6
Control unit: S1: green S2: green
PRO G:
During call or monitoring there is no image on the screen of the Terminals. All the other functions of the system are active
- Check the +Uv connection between the Supply control unit – Video connection boxes – Terminals.
- Locate and remedy the defect.
- Lack of tension between the +Uv and GNV terminals of the Terminals
- Lack of Vout connection at the terminals of the Outdoor panel or at the Vin or Vout terminals of the Supply control unit.
The system does not function (Supply control unit without accumulator)
Lack of tension from the 230V AC network
1
Check the 10A fuses from the electrical panel and the 1,6A Fuse 1 from the Supply control unit input. Check the continuity of the supply cables.
Control unit: S1: S2: PROG:
Short circuit in the system between +Uv and GNV .
Problem
Signaling
Solutions
No.
Possible causes
The system functions correctly
0
Control unit: S1: green S2: green PRO G:
Page 15
15
EN
The system functions (Supply control unit with accumulator)
The accumulator is in charging mode
9
ok
8
At a repeated monitoring command on any video Terminal installed, the image disappears (black LCD screen)
Connect the JP1 jumper. Check that at a repeated monitoring command, the image on the Terminal's screen remains unchanged.
The system functions (Supply control unit with accumulator)
Defect accumulator or discharged
10
The system functions (Supply control unit with accumulator)
Lack of tension from the 230V AC network The system functions powered by the accumulator
11
Replace the
accumulator
Check the 10A fuses from the electrical panel and the 1,6A Fuse 1 from the Supply control unit input. Check the continuity of the supply cables.
7
USE
Do not hit the glass screen with hard objects! If the front glass screen cracks, DO NOT touch the product!
7.1 User safety instructions
The JP1 jumper on the Supply control unit is NOT CO NNE CTED, at each stroke of the MONITORI NG key , the image on the screen of the Terminal will change from the image sent by the video Outdoor panel to off screen (there is no video signal connected to the Vin2 input of the Supply control unit)
Control unit: S1: green S2: green PRO G:
Control unit: S1: intermittent red – green S2: green
PROG:
Control unit:
S1: intermittent red –
green
S2: green
PROG:
acoustic signal
Control unit: S1: red S2:
PROG:
During the call and/or communication, the image on the Terminal's screen presents horizontal or oblique lines, fixed or mobile (moar)
Control unit: S1: green S2: green
PRO G:
7
Locate and remedy the defect.
The wires connected to the Vin / Vout and GNV terminals are not twisted until close to the terminals (until approx. 1 cm from the terminals).
Page 16
16
3 ACCESS
After the command, the lock is unblocked for 1...10 s for the access of the visitors.
// You cannot grant access without having a prior communication. .
2 CALL AND COMMUNICATION
Call duration: maximum 15 s (3 calls)
Communication duration: maximum 2 min.
The LED of the key blinks and the display shows the image sent by the video camera of the Outdoor panel. By touching the key, communication is initiated. The LED does not blink anymore
Do not touch the key during communication.
END COMMUNICATION NO ACCESS! The second touch of the key ends communication without granting access and
the Terminal returns to stand-by mode.
7.2 Use of the video Terminal
1 STAND-BY
The keyboard is not backlit. At the first touch, the keyboard is backlit and the Terminal may receive the
following commands: AUDIO – VIDEO MONITORING +VIDEO CAMERA SELECTION
Monitoring duration: 10 s By touching this key, you may see and listen to what goes on at the entrance, in front of the Outdoor panel. Monitoring is not possible if another Terminal of the system is being called or is during communication. // If several video cameras are installed within the system, the successive stroke of the key changes the camera through which the monitoring is done. VOLUME ADJUSTMENT OR
“TERMINAL TURNED OFF” By successive touches of this key, the 3 volume levels are passed through:
maximum (white LED), medium (red-white LED) and turned off (red LED). The red LED will remain permanently turned on until the key is pressed again.
ANSWE R THE CALL
ACCESS and END COMMUNICATION!
No matter what the state of the Terminal is: monitoring, call or communication, this key may action an automation connected to the system: auto access or garage gate, lighting system etc.
4 COM MAND AUX
AUXILIARY COMMAND
Stand-by
Call
Communication
Page 17
17
EN
7.3 Use of the Outdoor panel
1 STAND-BY
The key of the Outdoor panel and the inhabitant’s name are permanently backlit. The intermittent RED led signals the presence of video monitoring.
2 CALL AND COMMUNICATION
Call duration: maximum 15 s ( 3 calls) Communication duration: maximum 2 min.
Touch the key . The call to the inhabitant is signaled acoustically. You may end the call by pressing again the key . If the inhabitant answers, communication is initiated. If access is granted, the panel emits an acoustic signal, and the lock remains unblocked for maximum 10 seconds. If the inhabitant does not answer, after a minute, the panel returns to stand-by mode.
The symbol indicates the RFID tag reading area.
7.4 Use of the Access tag
Step
1
Supply control unit
PROG
Long stroke of PRO G. The red LE D is on.
The tags are already memorized. When used, the panel emits a recognition acoustic
signal and the symbol blinks green.
7.5 Programming additional tags
Touch with the tags, piece by piece, the symbol.
BEEEEEP
After each memorized tag [ ].
Outdoor panel
Step
2
Step
3
PROG
Press PROG.
The red LE D is off, programming procedure is terminated.
Any error during programming is signaled with [ ] .
BEEEEEP
In this case, the procedure must be recommenced from Step 2 .
Supply control unit
7.6 Deleting all the programmed tags
Use this procedure only if you lost one or more of your tags. The remaining ones must be programmed again.
First
Key
from
bottom up
Long press the key [ . The Panel enters programming.
BEEEEEP
]
7 short touches 2 x [
BEEP
].
BEEEEEP
Immediately one long press [ The tags are deleted.].
Step
3
PROG
Press PROG.
The red LE D is off, programming procedure is terminated.
Supply control unit
Step
1
Supply control unit
PROG
Long stroke of PRO G. The red LE D is on.
Outdoor panel
Step
2
Harry Johnston
Oliver Thompson
Page 18
11.2014 USM.KIT.VPE.2F0.ENY
Designed and Manufactured by ELECTRA Made in EU
ELECTRA Building Communications GmbH
Parkring 10, Liebenberggasse 7 | 1010 Wien – Austria Phone +43 1 516 33 – 3817 | Fax + 43 1 516 33 – 3000
office@electra-automation.at
MAINTENANCE
8
The Outdoor panels must be kept away from corrosive substances, lime or mechanical shocks. The Terminals must be kept away from water, or any other liquids, mechanical shocks, fumes, dusts etc. The components of the system can be cleaned with a piece of soft, cotton cloth. The optional accumulator connected with the Supply control unit will be replaced after the expiry of its life span. The Supply control unit ensures the accumulator's charging, as long as the accumulator is not defect. The state of the accumulator is indicated by the signals of the LED S1 and the acoustic warning in case of a defect.
WARRANTY
9
A three year warranty is granted, from the purchase date, on the basis of the proof of purchase and if the system was used according to the technical manual.
NO WARRANTY IS GRANTED for: inappropriate installation and use, deliberate damaging, theft, arson, natural disasters, unauthorized interventions to the system, the lack of protection of the system's components in case of renovation activities in the building.
The BELLCOME video systems for residential buildings are produced in compliance with the EU standards and bear the CE conformity marking.
AUTHORIZED REPRESENTATIVE of ELECTRA S.R.L.
10
Loading...