● Bended indoor coil with treated aluminum fins and coating for improved efficiency.
● Easy access to the interconnecting tubing and wiring connections, so that removing
the front grill or casing is not necessary.
SM WNGDCI 2-E.4 GB
● Refrigerant pipes can be connected to the indoor unit from 5 different optional
directions.
● Automatic treated air sweep.
● Low indoor and outdoor noise levels.
● Easy installation and service.
1-1
INTRODUCTION
CONTENTS
1.3 Indoor Unit
The indoor unit is wall mounted, and can be easily fitted to many types of residential
and commercials applications.
Indoor Unit features:
FeatureWNG 50WNG 60WNG 72 / 80
DisplayLCD or LEDLCD
IonizerYES
ESFYES
Fresh airYESNO
Indoor fan motorVariable speed (PG)
Horizontal motorized louverYES
Vertical motorized louverYES
Heating elementNO
M2L Cable portYES
Dry contactPresence detector or (jumper selected) power shedding
1.4 Filtration
The WNG DCI INV series presents several types of air filters:
● Easily accessible, and re-usable pre-filters (mesh)
● Pre-charged electrostatic filter (disposable)
● Active carbon filter (disposable)
● ESF. Active Electro Static re-usable filter (optional)
1.5 Ionizer (Optional)
A special design Ionizer protected by unique patents integrated into the indoor unit,
generating negative ions to the room providing comfort and upgraded indoor air quality.
1.6 Control
The microprocessor indoor controller, and an infrared remote control, supplied as
standard, provides complete operating function and programming.
Remote controllers: RC-2/3/4/5/7, RC-4i-1, RCW, μBMS.
Networking system Airconet version 4.2 and up, MIU SW version H8 and up.
1-2
SM WNGDCI 2-E.4 GB
1.7 Outdoor Unit
CONTENTS
The WNG DCI INV outdoor units can be installed as floor or wall mounted units by using
a wall supporting bracket. The metal sheets are protected from corrosion paint work
allowing long life resistance. All outdoor units are pre-charged. For further information
please refer to the Product Data Sheet, Chapter 2.
Outdoor Unit Feature
FeatureDCI 50DCI 60DCI 72 / 72Z / 80
Display3 LED’s
Base HeaterOptional
Outdoor FanVariable speed DC Inverter
M2L cable PortNoYes
NightNoYes
STBYNoYes
INTRODUCTION
Power SheddingNoYes
AlarmNoYes
1.8 Tubing Connections
Flare type interconnecting tubing to be produced on site.
For further details please refer to the Installation Manual, Appendix A.
1.9 Accessories
ItemDescription
MIU (WNG)MODBUS interface unit
RS485 Adapter
Base Heater
M2L cable Port
To be used as an interface
with RCW or μBMS remote
controllers
1.10 Inbox Documentation
SM WNGDCI 2-E.4 GB
Each unit is supplied with its own installation and operation manuals.
1-3
INTRODUCTION
CONTENTS
1.11 Matching Table
1.11.1 R410A
OUTDOOR UNITS
INDOOR UNITS
MODELREFR”
DCI 50R410A
DCI 60R410A
DCI 72
R410A
DCI 72Z
DCI 80R410A
WNG 50 DCI WNG 60 DCI WNG 72 DCIWNG 80 DCI
√
√
√
√
1-4
SM WNGDCI 2-E.4 GB
PRODUCT DATA SHEET
CONTENTS
2.PRODUCT DATA SHEET
2.1 WNG 50 DCI
Model Indoor UnitWNG 50
Model Outdoor UnitDCI 50
Installation Method of PipeFlared
CharacteristicsUnitsCoolingHeating
Capacity
Power input
EER (Cooling) or COP(Heating)
(1)
(1)
(1)
Energy efficiency classAA
Power supplyV/Ph/Hz220-240V/Single/50Hz
Rated currentA6.6 7.5
Starting currentA10.5
Circuit breaker ratingA20
Fan type & quantityCrossflow x 1
Fan speedsH/M/LRPM1200/1050/900
Air flow
(2)
H/M/Lm3/hr850/760/620
External static pressureMin-MaxPa0
Sound power level
Sound pressure level
DimensionsWxHxDmm1060x295x210
Weightkg15
Package dimensionsWxHxDmm1125x360x280
Packaged weightkg18
Units per palletunits16 units per pallet
Stacking heightunits8 levels
Refrigerant controlEEV
Compressor type,modelScroll,Panasonic 5CS130XCC03
Fan type & quantityPropeller(direct) x 1
Fan speedsH/LRPM920
Air flow H/Lm3/hr2160
Sound power levelH/LdB(A)63
Sound pressure level
(4)
H/LdB(A)53
DimensionsWxHxDmm795x610x290
Weightkg39
Package dimensionsWxHxDmm945x655x395
Packaged weightkg43
Units per palletUnits9 units per pallet
OUTDOOR
Stacking heightunits3 levels
Refrigerant typeR410A
Refrigerant chargless distancekg/m1.50/7.5
Additional charge per 1 meterg/mNo need
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
SM WNGDCI 2-E.4 GB
2-1
PRODUCT DATA SHEET
CONTENTS
2.2 WNG 60 DCI
Model Indoor UnitWNG-60
Model Outdoor UnitDCI60
Installation Method of PipeFlared
CharacteristicsUnitsCoolingHeating
Capacity
Power input
EER (Cooling) or COP(Heating)
(1)
(1)
(1)
Energy efficiency classBB
Power supplyV/Ph/Hz220-240V/Single/50Hz
Rated currentA8.9 8.6
Starting currentA10.5
Circuit breaker ratingA20
Fan type & quantityCrossflow x 1
Fan speedsH/M/LRPM1250/1100/1000
Air flow
(2)
H/M/Lm3/hr900/760/620
External static pressureMin-MaxPa0
Sound power level
DimensionsWxHxDmm1060x295x210
Weightkg15
Package dimensionsWxHxDmm1125x360x280
Packaged weightkg18
Units per palletunits16 units per pallet
Stacking heightunits8 levels
Refrigerant controlEEV
Compressor type,modelScroll,Panasonic 5CS130XCC03
Fan type & quantityPropeller(direct) x 1
Fan speedsH/LRPM820
Air flow H/Lm3/hr2860
Sound power levelH/LdB(A)65
Sound pressure level
(4)
H/LdB(A)55
DimensionsWxHxDmm846x690x302
Weightkg46
Package dimensionsWxHxDmm990x770x430
Packaged weightkg50
Units per palletUnits9 units per pallet
OUTDOOR
Stacking heightunits3 levels
Refrigerant typeR410A
Refrigerant chargless distancekg/m1.65/7.5
Additional charge per 1 meterg/mNo need
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
2-2
SM WNGDCI 2-E.4 GB
PRODUCT DATA SHEET
CONTENTS
2.3 WNG 72 DCI
Model Indoor UnitWNG-DCI 72
Model Outdoor UnitGC-DCI 72
Installation Method of PipeFlared
CharacteristicsUnitsCoolingHeating
Capacity
Power input
EER (Cooling) or COP(Heating)
(1)
(1)
(1)
Energy efficiency classBC
Power supplyV/Ph/Hz220-240V/Single/50Hz
Rated currentA9.8 10.3
Starting currentA15
Circuit breaker ratingA20
Fan type & quantityCrossflow x 1
Fan speedsH/M/LRPM1300/1150/10001350/1200/1050
Air flow
(2)
H/M/Lm3/hr950/800/6501000/850/700
External static pressureMin-MaxPa0
Sound power level
Sound pressure level
DimensionsWxHxDmm1060x295x210
Weightkg15
Package dimensionsWxHxDmm1115x350x260
Packaged weightkg18
Units per palletunits16
Stacking heightunits8 levels
Refrigerant controlEEV
Compressor type,modelTwo Rotary,Mitsubishi TNB220F
Fan type & quantityPropeller(direct) x 1
Fan speedsH/LRPM850
Air flow H/Lm3/hr3600
Sound power levelH/LdB(A)66
Sound pressure level
(4)
H/LdB(A)56
DimensionsWxHxDmm950x835x412
Weightkg65.5
Package dimensionsWxHxDmm1080x910x477
Packaged weightkg73
Units per palletUnits2
OUTDOOR
Stacking heightunits2 levels
Refrigerant typeR410A
Refrigerant chargless distancekg/m2.4kg/30m
Additional charge per 1 meterg/mNo Need
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
SM WNGDCI 2-E.4 GB
2-3
PRODUCT DATA SHEET
CONTENTS
2.4 WNG 72 / DCI 72Z
Model Indoor UnitWNG 72 DCI
Model Outdoor UnitDCI 72 Z R410A
DimensionsWxHxDmm1060x295x210
Net Weight kg15
Package dimensionsWxHxDmm1125x360x280
Packaged weightkg18
Units per palletunits16
Stacking heightunits8 levels
Refrigerant controlEEV
Compressor type,modelTwo Rotary,Sanyo(Sheny) C-7RVN153H0W
Fan type & quantityPropeller(direct) x 1
Fan speedsH RPM850
Air flow H m3/hr3600
Sound power levelH dB(A)66
Sound pressure level
(3)
H dB(A)56
DimensionsWxHxDmm950x835x412
Net Weightkg64.5
Package dimensionsWxHxDmm1080x910x477
Packaged weightkg72
Units per palletUnits4
OUTDOOR
Stacking heightunits2 levels
Refrigerant typeR410A
Standard chargekg(7.5m)2.3kg
Max.height differencem.15
Operation control type Remote control
Heating elements(Option)kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
DimensionsWxHxDmm1200x340x236
Weightkg18.5
Package dimensionsWxHxDmm1305x430x325
Packaged weightkg24
Units per palletunits12 units per pallet
Stacking heightunits6 levels
Refrigerant controlEEV
Compressor type, modelTwin Rotary DC Inverter Mitsubishi TNB220F
Fan type & quantityPropeller(direct) x 1
Fan speedsH/LRPM850
Air flow H/Lm3/hr3600
Sound power level
Sound pressure level
(3)
(4)
H/LdB(A)66
H/LdB(A)56
DimensionsWxHxDmm950x412x835
Weightkg66
Package dimensionsWxHxDmm1080x477x910
Packaged weightkg73.5
Units per palletUnits2 units per pallet
OUTDOOR
Stacking heightunits3 levels
Refrigerant typeR410A
Refrigerant chargless distancekg/m2.75/30
Additional charge per 1 meterg/mNo need
Operation control type Remote control
Heating elementskW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
SM WNGDCI 2-E.4 GB
Max. height differencem.Max. 15
2-5
3. RATING CONDITIONS
CONTENTS
Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units).
Cooling:
Indoor: 27oC DB 19oC WB
Outdoor: 35 oC DB
Heating:
Indoor: 20oC DB
Outdoor: 7oC DB 6oC WB
3.1 Operating Limits
3.1.1 R410A
RATING CONDITIONS
IndoorOutdoor
Cooling
Heating
Upper limit
32oC DB 23oC WB 46oC DB
Lower limit21oC DB 15oC WB-10oC DB
Upper limit27
Lower limit10
Volta ge
o
C DB 24oC DB 18oC WB
o
C DB-15oC DB -16oC WB
198 – 264 V
SM WNGDCI 2-E.4 GB
3-1
4. OUTLINE DIMENSIONS
CONTENTS
4.1Indoor Unit: WNG 50 / 60 / 72 DCI
OUTLINE DIMENSIONS
4.2
Outdoor Unit: DCI 50
SM WNGDCI 2-E.4 GB
4-1
OUTLINE DIMENSIONS
CONTENTS
4.3 Outdoor Unit: DCI 60
4.4 Indoor Unit: WNG 80
4-2
SM WNGDCI 2-E.4 GB
4.5 Outdoor Unit: DCI 72 / 72 Z / 80
CONTENTS
OUTLINE DIMENSIONS
SM WNGDCI 2-E.4 GB
4-3
PERFORMANCE DATA & PRESSURE CURVES
CONTENTS
5. PERFORMANCE DATA
5.1WNG 50 / DCI 50
5.1.1 Cooling Capacity (kW) - Run Mode
230[V] : Indoor Fan at High Speed.
OD COIL
ENTERING AIR DB
TEMPERATURE [0C]
DATA
ID COIL ENTERING AIR DB/WB TEMPERATURE [0C]
22/1524/1727/1929/2132/23
-10 - 20
(protection range)
TC80 - 110 % of nominal
SC80 - 105 % of nominal
PI25 - 50 % of nominal
TC4.935.225.515.806.09
25
SC4.104.164.224.284.34
PI1.101.131.151.181.20
TC4.674.965.255.545.83
30
SC3.944.004.064.124.18
PI1.261.28
TC4.424.71
35
SC3.783.843.903.964.02
PI1.411.44
TC4.174.46
40
SC3.623.683.743.803.86
PI1.561.591.611.641.66
TC3.864.154.444.735.02
46
SC3.433.493.553.613.67
PI1.751.771.801.821.85
LEGEND
TC – Total Cooling Capacity, kW
SC – Sensible Capacity, kW
PI – Power Input, kW
WB – Wet Bulb Temp., (oC)
DB – Dry Bulb Temp., (oC)
ID – Indoor
OD – Outdoor
1.31
5.00
1.46
4.75
1.331.36
5.295.58
1.481.51
5.045.53
5.1.2 Capacity Correction Factors
SM WNGDCI 2-E.4 GB
Cool ing Ca pacity Ratio Vs. Outdoor Temp era ture
1.20
1.10
1.00
0.90
0.80
0.70
Capaci ty Ration
0.60
0.50
202530354045
Outdoor DB Temperature [ºC]
5-1
PERFORMANCE DATA & PRESSURE CURVES
CONTENTS
5.1.3 Heating Capacity (kW) - Run Mode)
230[V] : Indoor Fan at High Speed.
ID COIL ENTERING AIR DB TEMPERATURE [0C]
OD COIL ENTERING
AIR DB/WB
TEMPERATURE [0C]
DATA152025
-15/-16
-10/-12
-7/-8
-1/-2
2/1
7/6
10/9
15/12
15-24
(Protection Range)
TC2.732.341.94
PI1.161.241.33
TC3.603.212.82
PI1.311.401.48
TC4.263.873.47
PI1.431.511.59
TC4.594.193.80
PI1.481.571.65
TC4.814.414.02
PI1.52
TC6.39
PI1.58
TC6.72
PI1.611.691.77
TC7.066.666.27
PI1.641.721.80
TC85 - 105 % of nominal
PI80 - 120 % of nominal
LEGEND
TC – Total Heating Capacity, kW
PI – Power Input, kW
WB – Wet Bulb Temp., (oC)
DB – Dry Bulb Temp., (oC)
ID – Indoor
OD – Outdoor
1.60
6.00
1.66
6.33
1.69
5.61
1.74
5.94
5.1.4 Capacity Correction Factors
5-2
1.20
1.10
1.00
0.90
0.80
0.70
0.60
Capaci ty Rati on
0.50
0.40
Hea ti ng Ca pacity Ra tio Vs. Outdoor Te mpera ture
-15-10-5051015
Outdoor WB Temperature [ºC]
SM WNGDCI 2-E.4 GB
PERFORMANCE DATA & PRESSURE CURVES
CONTENTS
5.2 WNG 60 / DCI 60
5.2.1 Cooling Capacity (kW) - Run Mode
230[V] : Indoor Fan at High Speed.
OD COIL
ENTERING AIR DB
TEMPERATURE [0C]
-10 - 20
(protection range)
25
30
35
40
(Protection Range)
46
(Protection Range)
ID COIL ENTERING AIR DB/WB TEMPERATURE [0C]
DATA
22/1524/1727/1929/2132/23
TC80 - 110 % of nominal
SC80 - 105 % of nominal
PI25 - 50 % of nominal
TC5.916.266.616.957.30
SC4.644.714.784.854.92