14.EXPLODED VIEWS AND SPARE PARTS LISTS .................................................14-1
15. APPENDIX A .........................................................................................................15-1
SM ASP 1-E.2 GB
i
1. INTRODUCTION
CONTENT
1.1 General
The new Alpha split wall mounted basic on comapct indoor and outdoor unit, it range
comprise the ST (cooling only) and RC (heat pump) models, as follows:
•Cooling Only:
ASP 9 410A (Flat,DF) ST / CSP 9 R410A ST;
ASP 12 R410A (Flat, DF) ST / CSP 12 R410A ST;
ASP 9 R22 (Flat,DF) ST / CSP 9 R22 ST;
ASP 12 R22 (Flat, DF) ST / CSP 12 R22 ST.
•Heat Pump:
ASP 9 R410A (Flat,DF) RC / CSP 9 R410A RC;
ASP 12 R410A (Flat, DF) RC / CSP 12 R410A RC;
ASP 9 R22 (Flat,DF) RC / CSP 9 R22 RC
ASP 12 R22 (Flat, DF) RC / CSP 12 R22 RC.
INTRODUCTION
The indoor Alpha SP units are available as LED display types only, featuring esthetic
design, compact dimensions, and low noise operation.
Display type models availability:
•LED Type: ASP 9 R410A (Flat, DF), ASP 12 R410A (Flat, DF).
1.2 Main Features
The Alpha SP series benefits from the most advanced technological innovations,
namely:
• R410A/R22 models.
• Microprocessor control.
• Infrared remote control with liquid crystal display.
• Supports Indoor Air Quality features, such as –.
• Bended indoor coil with treated aluminum fins and coating for improved efficiency.
• Easy access to the interconnecting tubing and wiring connections, so that removing
the front grill or casing is not necessary.
• Refrigerant pipes can be connected to the indoor unit from 5 different optional
directions.
SM ASP 1-E.2 GB
• Automatic treated air sweep.
• Low indoor and outdoor noise levels.
• Easy installation and service.
• New package design for indoor unit, it should be based on open sleeve and open
sides
• Installation manual to be printed on one page with back and front printing
• One RC simply manual printing on two side as the standard
1-1
INTRODUCTION
CONTENT
1.3 Indoor Unit
The indoor unit is wall mounted, and can be easily fitted to many types of residential
and commercials applications.
It includes:
• Casing with air inlet and outlet grills.
• A large-diameter tangential fan.
• Bended coil with treated aluminum fins.
• Motorized flaps
• Multi-speed motor with internal protection
• Advanced electronic control box assembly
• Interconnecting wiring terminal block
• Mounting plate
1.4 Filtration
The Alpha SP series presents only one type of air filters:
• Easily accessible, and re-usable pre-filters (mesh)
1.5 Control
The microprocessor indoor controller, and an infrared remote control, supplied as
standard, provide complete operating function and programming. For further details
please refer to the Operation Manual, Appendix A.
1.6 Outdoor Unit
The Alpha SP outdoor units can be installed as floor or wall mounted units by using a
wall supporting bracket. The metal sheets are protected by anti- corrosion paint work
allowing long life resistance. All outdoor units are pre-charged. For further information
please refer to the Product Data Sheet, Chapter 2.
It includes :
• Compressor mounted in a soundproofed compartment :
DimensionsWxHxDmm680*180*250
Net Weightkg6
Package dimensionsWxHxDmm740x310x248
Packaged weightkg8.5
Units per palletunits36
Stacking heightunits9 levels
Refrigerant controlCapillary tube
Compressor type,modelRotary,TOSHIBA PH170X1C-4DZDE3
Fan type & quantityPropeller(direct) x 1
Fan speedsHRPM900
Air flow Hm3/hr1265
Sound power levelHdB(A)6263
Sound pressure level
(3)
HdB(A)5253
DimensionsWxHxDmm610x520x240
Net Weightkg2626.5
Package dimensionsWxHxDmm725*550*355
Packaged weightkg2929.5
Units per palletUnits12
DimensionsWxHxDmm840x250x180
Net Weightkg7
Package dimensionsWxHxDmm900x310x248
Packaged weightkg9.5
Units per palletunits36
Stacking heightunits9 levels
Refrigerant controlCapillary tube
Compressor type,modelRotary,Sanyo,C-RV212H51BA
Fan type & quantityPropeller(direct) x 1
Fan speedsHRPM900
Air flow Hm3/hr1200
Sound power levelHdB(A)6365
Sound pressure level
(3)
HdB(A)5254
DimensionsWxHxDmm610x520x240
Net Weightkg29.530
Package dimensionsWxHxDmm725x550x355
Packaged weightkg31.532
Units per palletUnits12
DimensionsWxHxDmm680x250x180
Net Weightkg6
Package dimensionsWxHxDmm740x310x248
Packaged weightkg8.5
Units per palletunits36
Stacking height
Refrigerant control
Compressor type,modelRotary,Sanyo(Hua Run),C-1RV107
Fan type & quantityPropeller(direct) x 1
Fan speedsHRPM900
Air flow Hm3/hr1200
Sound power levelHdB(A)6262
Sound pressure level
DimensionsWxHxDmm610x520x240
Net Weightkg23.524
Package dimensionsWxHxDmm725x550x355
Packaged weightkg2626.5
Units per palletUnits12
DimensionsWxHxDmm840x250x180
Net Weightkg7
Package dimensionsWxHxDmm900x310x248
Packaged weightkg9.5
Units per palletunits36
Stacking heightunits9 levels
Refrigerant controlCapillary tube
Compressor type,modelRotary,Sanyo(Hua Run),C-RV133H1D
Fan type & quantityPropeller(direct) x 1
Fan speedsHRPM900
Air flow Hm3/hr1200
Sound power levelHdB(A)6364
Sound pressure level
(3)
HdB(A)5355
DimensionsWxHxDmm610x520x240
Net Weightkg2930
Package dimensionsWxHxDmm725x550x355
Packaged weightkg3132
Units per palletUnits12
DimensionsWxHxDmm680x250x180
Net Weightkg6
Package dimensionsWxHxDmm740x310x248
Packaged weightkg8.5
Units per palletunits36
Stacking heightunits9 levels
Refrigerant controlCapillary tube
Compressor type,modelRotary,Sanyo,C-1RV107
Fan type & quantityPropeller(direct) x 1
Fan speedsHRPM900
Air flow Hm3/hr1200
Sound power levelHdB(A)62
Sound pressure level
(3)
HdB(A)52
DimensionsWxHxDmm610x520x240
Net Weightkg26.5
Package dimensionsWxHxDmm725x550x355
Packaged weightkg28.5
Units per palletUnits12
DimensionsWxHxDmm840x250x180
Net Weightkg7
Package dimensionsWxHxDmm900x310x248
Packaged weightkg9.5
Units per palletunits36
Stacking heightunits9 levels
Refrigerant controlCapillary tube
Compressor type,modelRotary,Sanyo,C-RV133H1D
Fan type & quantityPropeller(direct) x 1
Fan speedsHRPM735
Air flow Hm3/hr1450
Sound power levelHdB(A)65
Sound pressure level
(3)
HdB(A)54
DimensionsWxHxDmm760x545x245
Net Weightkg32.5
Package dimensionsWxHxDmm870x600x320
Packaged weightkg35
Units per palletUnits12
Fan type & quantityCrossflow x 1
Fan speedsH/M/LRPM1320/-/1100
Air flow (1)H/M/Lm3/hr450/-/360
External static pressureMin Pa0
Sound power level (2)H/M/LdB(A)53/-/49
Sound pressure level(3)H/M/LdB(A)41/-/35
Moisture removall/hr0.99
Condenstate drain tube I.Dmm16
INDOOR
DimensionsWxHxDmm680x250x180
Net Weightkg6
Package dimensionsWxHxDmm740x310x248
Packaged weightkg8.5
Units per palletunits32
Stacking heightunits8 levels
Refrigerant controlCapillary tube
Compressor type,modelRotary,Toshiba(GMCC),PA103X1C-4FZDE1
Fan type & quantityPropeller(direct) x 1
Fan speedsHRPM900
Air flow Hm3/hr1200
Sound power levelHdB(A)62
Sound pressure level(3)HdB(A)52
DimensionsWxHxDmm610x520x240
Net Weightkg26.5
Package dimensionsWxHxDmm720x550x360
Packaged weightkg28.5
Units per palletUnits12
Operation control type Remote control
Heating elements (Option)kW
Others
(1)Airflow in ducted units;at nominal external static pressure.
(2)Sound power in ducted units is measured at air discharge.
(3)Sound pressure level measured at 1-meter distance from unit.
(4)Rating conditions in accordance to ISO 5151 and ISO 13253 (for ducted units).
Fan type & quantityCrossflow x 1
Fan speedsH/M/LRPM1250/-/880
Air flow (1)H/M/Lm3/hr620/-/390
External static pressureMin Pa0
Sound power level (2)H/M/LdB(A)53/-/47
Sound pressure level(3)H/M/LdB(A)40/-/33
Moisture removall/hr1.22
Condenstate drain tube I.Dmm16
INDOOR
DimensionsWxHxDmm840x250x180
Net Weightkg8
Package dimensionsWxHxDmm900x310x248
Packaged weightkg10.5
Units per palletunits32
Stacking heightunits8 levels
Refrigerant controlCapillary tube
Compressor type,modelRotary,Panasonic,5PS132EAC22
Fan type & quantityPropeller(direct) x 1
Fan speedsHRPM735
Air flow Hm3/hr1450
Sound power levelHdB(A)65
Sound pressure level(3)HdB(A)54
DimensionsWxHxDmm760x545x245
Net Weightkg32.5
Package dimensionsWxHxDmm870x600x320
Packaged weightkg35
Units per palletUnits12
Operation control type Remote control
Heating elements (Option)kW
Others
(1)Airflow in ducted units;at nominal external static pressure.
(2)Sound power in ducted units is measured at air discharge.
(3)Sound pressure level measured at 1-meter distance from unit.
(4)Rating conditions in accordance to ISO 5151 and ISO 13253 (for ducted units).