230V 1 Phase­Power Output
Load
2-kW 9-Amp 3-kW 13-Amp
Weather Protection
The heater must be installed within a dry weather proof enclosure.
CAUTION! If the heater is not used during winter months it must be drained to prevent frost damage.
Electrical Connection
The heater must be installed in accordance with the country / regional requirements & regulations. In any event the work must be carried out by a qualied electrician, who will provide a certicate of conformity upon completion of the work.
The heater has been supplied pre-wired with a power lead & plug for your safety.
It is essential that the power supply to the heater is protected by a 30mA RCD (Residual Current Device). If in doubt consult a qualied Electrician.
Power Requirements
Flow Requirements
The ow rate of water into the heater must not exceed 17,000 litres per hour (3,740 UK gallons/hour) A higher ow rate will require the installation
of a bypass to prevent damage to the heater elements. The heater will not operate with a ow rate below 1,000 litres / hour (220 UK gallons/hour)
Page 6
5
ENGLISH
Water Quality
The water quality must be within the following limits: PH 6.8 - 8.0, TA (Total alkalinity) 80—140ppm (parts per million) Chloride Content MAX: 150 mg/litre Free Chlorine: 2.0 mg/litre Total Bromine: Max 4.5 mg/litre TDS (Total Dissolved Solids) / Calcium hardness 200— 1,000ppm Nano Stainless Steel heaters with yellow enclosure (Incoloy 825 Heating element) are NOT suitable for use on saline (salt) water pools. Nano heaters with white enclosure (Titanium Heating element) are suitable for use with salt water pools with a salt concentration up to 8000ppm (8g/litre).
Water chemistry is complicated if in doubt seek expert advise.
Operating Instructions
Upon completion of the installation, run the water-circulating pump to purge the system & heater of air (i.e. Remove any trapped air in the system & heater). TIP: You can encourage air out of the heater ow tube by gently elevating the exit port of the heater when the pump is running. The heater will only switch ‘On’ (red light indicator illuminated) when the following criteria are met ie:
l
Water circulating pump is ‘On’ delivering in excess of 1,000 litres /
hour (220 UK gallons/hour) l
Temperature set point dial is set to a higher value than that of the water
Q: How long will it take to heat my pool?
A: Assuming no heat losses, and a heater sized in the ratio 1.5-kW per 1,000
UK gallons of water (4,545-litres): it will take 2 days of continu-ous running to raise the temperature of a pool from tap temperature to swimming temperature. Heat loss will slow the heating process, particu-larly during periods of cold weather, hence the higher the water tempera-ture is to be maintained above average ambient air temperature, the slower the heating process will become.
The only inuencing factors are the level of insulation and the location of the pool with regard to wind shelter.