Elecro Engineering B-100 Installation & Operating Manual

www.elecro.co.uk
1
B-100 Pool Heater
Installation & Operating Manual
1
www.elecro.co.uk
ENGLISH
Thank you for purchasing the Elecro B-100 direct electric swimming pool heater manufactured in England to the highest standards.
To ensure your new heater will give years of trouble free service please
carefully read the following instructions. Incorrect installation will aect your warranty. Do not discard this manual, please retain for future
reference.
Safety!
The appliance is not to be used by children or persons with reduced physical , sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. Children should be supervised to ensure they do not play with the appliance.
Always switch o the power to the Heater before carrying out any maintenance.
www.elecro.co.uk
2
Positioning
Your heater should be horizontally sited on a level oor or a suitable shelf allowing sucient space for pipe connections and wiring. It must be sited downstream (after) the pump & lter but upstream (before) any chemical dosing plant.
ENGLISH
Correct
In-Correct
www.elecro.co.uk
3
www.elecro.co.uk
ENGLISH
Flow Requiremnts
The heater should be connected to a ltration system with a minimum ow volume of 12,000-litres per hour (2,640 UK gallons per hour). The maximum ow volume the B-100 heater will operate with is 40,000-litres per hour (8,800 UK gallons per hour). Recommended Flow is 30,000-litres per hour (6,600 UK gallons per hour). If the ow volume is greater a by-pass must be installed to prevent damage to the heating elements.
N.B the ow direction is xed and must not be reversed.
Weather Protection
The heater must be installed within a dry weatherproof enclosure.
Caution
If the heater is not used during winter months it must be drained to prevent frost damage.
Pipe Work
The heater has 63-mm male ABS inlet and outlet spigots for solvent weld connection, reduction adapter unions are also supplied to allow connection to 2” pipe work.