Elecom ECLEAR refree HCM-P01 Series Instruction Manual

ECLEAR refree
Instruction Manual
For use in Hong Kong and the Philippines only.
Other customers should refer to the local manuals in the country of purchase.
www.elecom.co.jp/global/download-list/manual/
Thank you for purchasing this product.
This manual describes the operation and precautions for safely handling this device.
Read this manual before using the device. After reading the manual, keep it in a safe place for future reference.
HCM-P01 series
Safety Precautions (Be sure to always follow these precautions)
In order to prevent personal injury or damage to property involving you or any other persons, be sure to observe the precautions outlined below.
The following symbols show the degree of injury or damage which may result
through incorrect use or failure to observe the precautions in the text.
Danger
Warning
Caution
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of bodily harm or damage to property.
This symbol indicates a “Prohibited” action which must not be performed.
This symbol indicates a “Mandatory” action which must be performed.
Danger
Do not use this device in combination with the following medical devices.
Internally implanted electronic devices such as pacemakers Electrical medical equipment used for life support such as artificial heart and lung apparatus Wearable medical electronic equipment such as electrocardiographs
Otherwise, the device may break down or cause injuries.
Warning
Do not use the device near the heart, head, face, mouth, genitals or areas affected by illness or covered with tattoos.
Accident, injuries or illness may occur.
Do not use this product with therapeutic devices.
Otherwise, you may feel nauseous.
2 3 4 5 7
Warning
Do not allow children to use this device or allow to play or stand on the Main Unit or gel pad.
There is a risk of accident or injury.
Do not apply the gel pad onto metal objects such as watches or necklaces.
There is a risk of accident or injury.
Do not use the device if the surface of the gel pad is damaged or uneven.
Accidents, problems or malfunction may occur.
Turn the power off before connecting or disconnecting the Main Unit and gel pad, or when sticking down, changing, or peeling off the gel pad.
This may result in electric shock or malfunction.
Any person suffering from the following should consult a doctor prior to using the device.
1) People currently receiving medical treatment from a doctor, or who are otherwise experiencing symptoms of an illness
2) People with malignant tumours
3) People with cardiac or cranial nerve abnormalities
4) Pregnant women or those who have just given birth
5) People with a body temperature of 38°C or higher (fever)  Example 1: acute onset of symptoms (fatigue, chill, blood pressure
fluctuations)
Example 2: state of debilitation
6) People with infectious diseases
7) People with skin abnormalities or problems
8) People with acute (painful) disorders such as spinal fractures, sprains and muscle tears
9) People suffering from exhaustion
10) People using medication
11) People with abnormal blood pressure
12) People with disabilities
13) People who are unable to express their own wishes
14) People with impairments, advanced peripheral circulatory disorders,
or illnesses such as diabetes
15) People with a low body temperature
16) People with circulatory disorders
17) People with no effect following a significant period of use
18) People whose skin reacts badly to the gel pad 
Accident or illness may occur.
Warning
Do not disassemble, repair, or modify the device.
No disassembling
This may result in fire or electric shock.
This product is intended to be used by one person at a time.
The device cannot be shared by multiple users.
Accident or electric shock may occur.
Caution
Do not use or store the device in any of the following locations.
In direct sunlight In areas of high temperature such as in proximity to heating devices In areas of high humidity such as bathrooms In wet or damp places In dusty environments In places with high levels of vibration
There is a risk of fire, electric shock or malfunction.
Do not use the device during sleep.
There is a risk of accident or injury.
Do not use the device before or when in control of cars, motorcycles and bicycles.
An accident or a malfunction may occur.
Do not leave the gel pad affixed to the skin for a long period of time.
It may cause skin inflammation.
Do not use the gel pad when it is wet.
This may result in electric shock.
Do not use the product on one area for more than 15 minutes.
Accident or illness may occur.
Do not overlay two gel pads during use.
Accident or illness may occur.
Ensure that the Main Unit and the gel pad are properly connected prior to use.
Caution
Confirm that each operation button works properly before use.
When using the device for the first time, or when the device has been idle for a long time, check the instruction manual and confirm whether it was operating normally previously.
If you feel strong irritation, experience eczema, redness or itchiness of the skin due to using this device, stop use immediately and consult a doctor.
Accident or illness may occur.
Avoid touching the USB connector port with your hands, fingers or other parts of the body.
This may result in electric shock, poor contact or a malfunction.
Do not insert metal into USB connector port.
This may result in heating or fires.
Do not forcibly pull the cable, bend it or place any heavy objects on it.
Otherwise, it may cause wires to be damaged or broken, or even cause a fire or electric shock.
Do not use the USB function if the dedicated USB cable is damaged or if the USB connector port is loose.
This may result in a fire or electric shock.
Do not use travel adaptors or other transformers for charging.
This may result in heating or fires.
Do not charge the device using an in-vehicle cigarette lighter.
This may result in a fire, heating or an electric shock.
Do not touch the USB cable or gel pad with wet hands.
No wet hands
This may result in an electric shock, malfunction or accident.
Do not use the provided USB cable for purposes other than charging the Main Unit.
The dedicated USB cable cannot be used for communication purposes or for charging other equipment.
Check whether the USB cable is properly inserted before charging.
A fire or electric shock may occur if the USB cable is not properly inserted.
Caution
Charge the device every three months.
The battery cannot be charged when it is fully discharged.
When a malfunction occurs, stop using the device immediately and cut the power supply. Contact the retailer.
Do not leave or store the device within the reach of young children.
An accident may occur. In the unlikely event that a child swallows the Main Unit, consult a doctor immediately.
Do not pour water into the Main Unit or make it wet.
This may result in heating, breaks or fires.
When disposing of this product, please do so in accordance with the regulations of your local government.
6
About this product
Purpose
This product is designed to provide relaxation and rejuvenation through stimulation of the muscles.
For household use.
ECLEAR refree
When a low-frequency current passes through electrodes and contacts the human body, the muscles contract and the nerves are stimulated to produce a feeling of relaxation.
Standard usage time
Standard use time is 15 minutes on any body part. Exceeding 15 minutes may cause you to feel unwell.
This product has a built-in timer that automatically turns the power off after around 15 minutes.
Effective time for usage
We recommend that you use the device after a bath.
Caution:
Wipe all sweat or moisture from the skin prior to use.
Confirm package contents
Check all items prior to use.
We make every effort to ensure the packaging is correct, If any parts are missing or damaged, contact the seller immediately.
HCM-P011G2 series
Main Unit×1
Dedicated USB cable, storage sheet, pouch (small), Instruction Manual (this Manual)
HCM-P011G3 series
Main Unit×1
Dedicated USB cable, storage sheet (for Wide Pad only) pouch (large), Instruction Manual (this Manual)
HCM-P012G1 series
Main Unit×2
Dedicated USB cable, storage sheet, pouch (small), Instruction Manual (this Manual)
2Point Pad×1 (consumables)
Wide Pad×1 (consumables)
1Point Pad×2 (consumables)
8 9 10 11
Optional items
For information concerning the optional items, please contact your dealer.
The following optional items are available.
Sales name: Gel pad P01
1 Point Pad (2 pieces inside)
Model:
HCM-P01G1PN
Wide Pad (1 piece inside)
Model: HCM-P01G3BU
HCM-P01G3PN
2 Point Pad (1 piece inside)
Model: HCM-P01G2BU
HCM-P01G2PN
Name of each part Preparation [2Point Pad]
Main Unit
[] (strong) button
Main Unit
USB connector port (for charge)
Power button (mode switching button)
Connecting terminal (Main Unit side)
Gel pad [2Point Pad]
Connecting terminal (gel pad side)
Gel pad
Protective film
Dedicated USB cable
USB A connector USB a microB connector
LED light
[] (Weak) button
Make sure the battery is fully charged before use (after purchase or when it has not been used for a long period of time).
Charge
1
Insert the USB micro B connector of the dedicated USB cable into the USB
port of the Main Unit.
Insert the USB A connector of the dedicated USB cable into the following
USB port to power the device.
When it is properly connected, the device beeps and the LED light flashes.
LED light The LED light ashes red when the degree of charge is less than 80%, ashes green when it is 80% or more, and continuously lights green when fully charged.
Dedicated USB cable
When connected to a PC
USB2.0, USB3.0 or USB3.1 of a IEC60950-compliant computer
USB A connector
Caution:
Use of travel adaptors or other transformers for charging may cause
excessive heating or a fire.
Do not operate the device when it is charging.
After the Main Unit is charged many times, its usage time may decrease. If the usage time is excessively short, the battery has reached the end of its lifecycle. It cannot be replaced.
When charging is complete, you will hear a beep
Charge time: approximately 3.5 hours
micro B Connector
Dedicated USB cable
USB connector plug
Install the gel pad onto the Main Unit
2
Operate the 1 Point Pad in the same way as you operate the Wide Pad.
Take the gel pad from the package during first use.
(Do not remove the protective film from the gel pad.)
Confirm that the Main Unit is disconnected from the power
(LED light is off).
The gel pad is not properly connected to the Main Unit until a click
is heard.
Caution:
Use the gel pad provided by the company.
When replacing the gel pad
Take the Main Unit from the gel pad.
Take the gel pad from the package.
(Do not remove the protective film from the gel pad.)
Confirm that the Main Unit is disconnected from the power
(LED light is off).
The gel pad is not properly connected to the Main Unit until a click
is heard.
12 13
How to install the gel pad [2Point Pad]
Remove the protective film by grasping the protruding part
1
Remove the storage sheet the second time you use the device. For the Wide Pad, please take hold of both tabs to peel it off.
Affix the gel pad where required
2
Affix the gel pad closely onto the skin.
The Main Unit automatically disconnects if the gel pad leaves the skin.
Caution:
Do not place the gel pad onto metal objects such as necklaces or navel jewelry.
How to use
Do not touch the adhesive surface of the gel pad. When the gel pad is no longer sticky, refer to “Care of the gel pad” (
Do not fold the pad.
P20).
How to use
Examples of applying gel pads
After use [2Point Pad]
Care of [2Point Pad]
Turn on the power
1
To turn on the device, press and hold the Power button for approximately 2 seconds until the device beeps
The LED light becomes green.
[] (strong) button
[] (Weak) button
Power button
Switch mode
2
Press the Power button to change mode during use.
When the device is connected, it starts in "Auto" mode.
When the Power button is pressed, the device will beep and change modes in the following sequence. When the device returns to “Auto” mode, it will beep.
Mode Movement
"Deep" "Standard" "Rhythmical" "Solid”
Auto
continuously cycles
Deep
Standard Current
Rhythmical Current
Solid Current
Current
Storage
Keep this product in an environment that meets the following conditions.
Storage temperature: - 10°C - 60°C
Storage humidity: 20 - 85%RH
Notes regarding care and storage
• Do not use volatile oil or diluent for cleaning.
• Do not store the device in any of the following locations.
- In direct sunlight
- Places with high temperatures or high humidity, and
places near sources of moisture or with a lot of dust
- Places with high levels of vibration
- Places where chemicals are stored or corrosive
gases are produced
• Keep the device out of the reach of children.
• When not idle for a long period of time, store the device in a fully charged
condition at normal temperature (10 to 30° C).
• Charge the device every three months. If left completely idle, recharging may
be impossible.
Check
Repair your device after it has been in use for a long time!
Sounds or vibrates abnormally
Does your
during charging or use
device have
The Main Unit heats up
this type of
excessively
problem?
The Main Unit becomes deformed
or gives off a burnt smell
21
Diluent
To avoid an accident, unplug
Stop
the device or pull off the
use
dedicated USB cable. The seller should check this.
Volatile
oil
Alcohol
Adjust the strength
3
10 levels of strength are available.
When the device is connected for the first time or when the mode is
changed, the intensity level is 1.
• When you press the [] (strong) button, you will hear a beep and the
intensity rises by 1 level.
• When you press the [] (weak) button, you will hear two beeps and the
intensity will decrease by 1 level.
• If you press the [] (strong) button when the device is at level 10 or the [−] (weak) button when it is at level 1, the device will beep three times and the intensity will not change.
Turn off the power
4
After 15 minutes of use, the device will beep and turn off automatically.
To tur n off the power, press and hold either the Power button, the [+]
(Strong) button, or the [-] (Weak) button for approximately 2 seconds.
The device cuts the power when the gel pad is detached from the skin
or the Main Unit becomes separated from the gel pad.
Time
[] (Weak) button
Time
Time
Time
Disposal
Notes regarding recovery of lithium-ion batteries
Lithium-ion batteries are an important recyclable resource, so we request your cooperation in recycling. When disposing of this product, do so in accordance with local regulations.
• When disposing of this product, do not disassemble the battery.
Nail polish
remover
• Do not dispose of the product as general household waste. Discarded lithium-ion
batteries may short circuit in garbage trucks and cause excessive heating or a fire.
How to remove lithium-ion batteries
Never disassemble this product except when disposing of it.
The following procedures apply only to discarded products, not those requiring repairs. Do not disassemble the product as it may
Warning
cause the device to malfunction or an accident.
When the device run out of the batter y power.
Remove the battery using a screwdriver in the following steps.
Insert a straight screwdriver into the groove
just beneath the Power button of the Main Unit
Remove the screws used to fasten the circuit
board
Cut the black negative connector wire on the
battery behind the circuit board with a wire cutter
Remove the battery
After removing the battery, affix tape to the terminals
to avoid a short circuit between the (+) and (-) terminals of the battery.
Storage
Take the gel pad off your skin.
Grasp the protruding part of the gel pad when doing so. Do not touch its adhesive surface.
Without removing the Main Unit from the gel pad, affix the pad to the
storage sheet.
When two pieces are included, affix them on both sides of the storage sheet.
Storage sheet
Store it in the attached storage pouch.
Protruding part
[] (strong) button
1 Point Pad
Arm Palm Knee
Arch Neck Shoulder
Upper arm Back and waist Achilles tendon
2 Point Pad
Elbow Knee Shank
Shoulder Upper arm Back and waist
Buttocks Thigh (back) Calf
Wide Pad
Thigh Shoulder
Back Waist
Buttocks Calf
Power button
Caution:
Do not leave the device in areas of high temperature or humidity or in direct sunlight.
15 16 17 18 20
Troubleshooting
Malfunction
The battery fails to power the device
The device powers off quickly The device powers off during use
The device cannot be charged
The gel pad does not stick to the skin
The adhesive surface of the gel pad has peeled
There is no feeling of stimulation
Groove
or the stimulation is weak
Battery
The skin becomes reddened/irritated
The device is insufficiently charged or the battery is flat
The battery is charging
The gel pad does not stick to the skin
The device is insufficiently charged or the battery is flat
The Main Unit and the gel pad are poorly connected
The gel pad does not stick to the skin properly
The battery is flat after it has been stored for a long time
Does not remove the transparent protective film from the adhesive surface of the gel pad
The adhesive surface of the gel pad is dirty
Use the pad immediately after cleaning it
The adhesive surface of the gel pad is damaged
There is a significant amount of sweat or moisture on the adhesive surface of the gel pad
The gel pad is not in close contact with the skin
The gel pad is overlapping
The adhesive surface of the gel pad is dirty
The gel pad is not properly connected
The strength is too weak
Charging is insufficient or the battery is flat
The adhesive surface of the gel pad is dirty or damaged
Usage time is too long
The gel pad is not in close contact with the skin
The adhesive surface of the gel pad is dirty or dry
The adhesive surface of the gel pad is damaged
Cause Solution
Unplug and then charge the device. P11
Remove the dedicated USB cable after the battery is completely charged. P11
Unplug the device and place the gel gad close to skin. P13
Unplug and then charge the device. P11
Unplug the device and connect the Main Unit and gel pad again. P12P13
Unplug the device and place the gel gad close to skin. P13
The device doesn’t work. To prevent full discharge, charge the device every three months. P20
Remove the transparent protective film from the adhesive surface of the gel pad. P13
Spray a small amount of water to clean the pad with your fingers for a few seconds. P20
Make sure the adhesive surface of the pad is dry. P20
The gel pad is a consumable item. Stop using the gel pad if its adhesive surface is damaged and purchase a new one. P9
The gel pad is a consumable item. Stop using the gel pad if its adhesive surface is damaged and purchase a new one. P9
Ensure close contact with the skin. P13
Avoid overlapping. P13
Spray a small amount of water to clean the pad with your fingers for a few seconds. P20
Connect the gel pad properly until it clicks. P12
Adjust the strength. P15
Charge the device. P11
The gel pad is a consumable item. Stop using the gel pad if its adhesive surface is damaged and purchase a new one. P9
Use in one area for 15 minutes or less, then peel the gel pad away from the skin after use. P15
Ensure close contact with the skin. P13
Spray a small amount of water to clean the pad with your fingers for a few seconds. P20
The gel pad is a consumable item. Stop using the gel pad if its adhesive surface is damaged and purchase a new one. P9
Product specifications
Supply voltage
Built-in battery
Number of charge cycles
Charge time approximately 3.5 hours * 3
Operating time approximately 150 minutes (when fully charged) * 4
Maximum output current 10 mA or less
Rated output voltage
Fundamental frequency
Output pulse width
Power consumption approximately 0.2 W
Timer approximately 15 minutes
Main Unit dimensions approximately φ44 mm× D11 mm
Cable length 20 cm
Main Unit weight approximately 13 g
Operating temperature and humidity ranges Storage temperature and humidity ranges
1Comply with JIS C 8711 2Overcharge, over-discharge, over-voltage protection functions are provided 3Standard when a flat battery is fully charged 4It varies depending on the type of operation and its surroundings.
DC5.0V
Lithium-ion batteries (40 mAh 1 2)
approximately 500 times * 1
approximately 32V
approximately 2 – 550 Hz
approximately 200 μS
0°C - 40°C, 20 - 85% RH
-10 - 60, 20 - 85% RH
ELECOM CO., LTD.
www.elecom.co.jp/global/
ELECOM Korea Co., Ltd. 5F Suam Bldg. 1358-17, Seocho2-dong, Seocho-gu, Seoul 137-862, Korea TEL : +82 (0) 2 - 1588 - 9514 FAX : +82 (0) 2 - 3472 - 5533 www.elecom.co.kr
新宜麗客(上海)商貿有限公司 上海市徐
区肇嘉浜路1065甲号1603H室
電話:+86(0)40-0867-3568
www.elecom.cn
Unauthorised copying and/or reproducing of all or part of this manual is prohibited.
The specications and appearance of this product may be changed without prior notice for product improvement purposes.
When exporting this product, check the export regulations for the country of origin.
Company names, product names, and other names in this manual are either trademarks or registered trademarks.
A customer who purchases outside Japan should contact the local
LTD. (Japan)”, no customer support is available for enquiries about purchases or usage in/from any countries other than Japan. Also, no
foreign language other than Japanese is available. Replacements will be made under stipulation of the Elecom warranty, but are not
available from outside of Japan.
ECLEAR refree gel pad
Instruction Manual for use in Hong Kong and the Philippines 1st edition, April 3, 2018
©2018 ELECOM Co., Ltd. All Rights Reserved.
22 23 24 25
1914
ELECOM Sales Hong Kong Ltd. 2/F, Block A, 2-8 Watson Road, Causeway Bay, Hong Kong TEL : +852 2806 - 3600 FAX : +852 2806 - 3300 email : info@elecom.asia
re Pte. Ltd
ELECOM Singapo 33 UBI AVENUE 3 # 03-56. VERTEX SINGAPORE (408868) TEL : +65 6347 - 7747 FAX : +65 6753 - 1791
retailer in the country of purchase for enquiries. In “ELECOM CO.,
MSC-HCM-P01_new_HK-PH_eng_ver.111
26
Remove the gel pad from the Main Unit to maintain it.
Care of the gel pad
The gel pad requires maintenance when one of the following circumstances arises.
• The gel pad does not stick to the skin
• Stimulation is weak during use
• The skin becomes irritated during use
• The gel pad is dirty
• The gel pad cannot be glued onto the storage sheet If you continue to feel irritation or if stimulation remains weak even after cleaning, replace the gel pad.
Spray a small amount of water to clean the pad with your fingers for a few
seconds.
Do not use too much water. This may decrease adhesion or cause the adhesive
surface to be damaged.
Grasp the protruding part to make the pad naturally dry.
With insufficient drying, the adhesive strength may become
weak.
Do not wipe the adhesive surface with a tissue or cloth. Avoid exposure to direct sunlight.
Caring for the Main Unit
• Wipe the Main Unit with a dry, soft cloth when it is dirty.
Caution:
Do not let water enter the Main Unit or USB connector port.
Loading...