T
SectionPage
1 About this instrument ..............................2
2 Getting started .........................................3
3 Taking a reading ......................................6
4 Measurement area ...................................6
11 Related equipment .................................10
hank you for your purchase of this Elcometer
214L Infrared Digital Thermometer. Welcome
to Elcometer.
Elcometer are world leaders in the design,
manufacture and supply of inspection equipment
for coatings and concrete. Our products cover all
aspects of coating inspection, from development,
through application to post application inspection.
This Elcometer 214L Infrared Digital
Thermometer is a world beating product. With the
purchase of this product you now have access to
the worldwide service and support network of
Elcometer. For more information visit our website
at www.elcometer.com
1
1 ABOUT THIS INSTRUMENT
The Elcometer 214L Infrared Digital
Thermometer is an easy-to-use instrument which
measures the surface temperature of objects. A
laser pointer in the instrument helps the user to
aim the thermometer at the object and pinpoint
the exact area of measurement.
The Elcometer 214L measures the infrared
energy emitted by a surface to calculate
temperature. Because this is a ‘non-contact’
method of measurement, the instrument is ideal
for electrical and mechanical maintenance,
HVAC checks, automotive testing and other
applications; anywhere that temperature is a
factor.
The instrument is small and lightweight and may
be carried easily in a pocket.
1.1 Instrument features
•Precision glass optics for accurate noncontact measurement
•Temperature range from -32°C up to 530°C
(-20°F to 788°F)
•Switchable between °C and °F
•Laser alignment
•Fast scanning of cold and hot spots
•Exact measurement of objects as small as
13 mm (0.5”) at any distance less than
140 mm (5.5”)
•Optical resolution 20:1
•Angled shape allows simultaneous view of
target object and display
•Backlit display
•Extremely lightweight
2
1.2 What the box contains
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
•Elcometer 214L Infrared Digital
Thermometer
•Battery
•Operating instructions
The Elcometer 214L Infrared Digital
Thermometer is packed in a cardboard and foam
package. Please ensure that this packaging is
disposed of in an environmentally sensitive
manner. Consult your local Environmental
Authority for further guidance.
To maximise the benefits of your new
Elcometer 214L, please take some time to
read these Operating Instructions. Do not
hesitate to contact Elcometer or your
Elcometer supplier if you have any questions.
2 GETTING STARTED
Warning! This instrument is fitted
with a Class 2 Laser.
Do not point the laser directly at
the eye or indirectly off reflective
surfaces as this may cause
serious damage to the eye.
2.1 Fitting the battery
Press and slide down the battery compartment
cover at the rear of the instrument. Insert a single
9 V PP3 alkaline battery; take care to ensure
correct battery polarity. Replace the battery
compartment cover.
3
2.2 The controls
Selects °C
Toggles
laser on/off
UP
Toggles
between
MAX/MIN
MODE
Selects °F
Toggles
backlight
on/off
DOWN
Press to
take a
reading
TRIGGER
HOLD
MAX
MAX
0
0
Your Elcometer 214L is operated using 4 buttons.
2.3 Switching on/off
The instrument switches on when the TRIGGER
button is pressed and switches off automatically
7 seconds after the TRIGGER button is released.
2.4 Switching the laser on/off
1. Press and hold the TRIGGER button.
2. Press the UP button to toggle the laser
on/off.
2.5 Switching the backlight on/off
While the instrument is switched on, press the
DOWN button to toggle the backlight on/off.
4
2.6 Symbols on the display
HOLD
MAX
MAX
0
0
Backlight, low
battery and laser
warnings
Max/Min reading
Temperature and
units
Indicates ‘held’
temperature
(7 seconds max.)
Emissivity
2.7 Selecting units (°C/°F)
To select °C:
1. While the instrument is switched off, press
and hold the UP button.
2. Press the TRIGGER button.
The next time the instrument is switched on, the
display will show temperatures in °C.
To select °F:
1. While the instrument is switched off, press
and hold the DOWN button.
2. Press the TRIGGER button.
The next time the instrument is switched on, the
display will show temperatures in °F.
2.8 Selecting maximum or minimum
Press the MODE button to toggle between
displaying MAX and MIN on the display.
5
3 TAKING A READING
132037
50
140
300
700
1000
spot size (mm)
distance (mm)
1. Aim the lens of the instrument at the object
and press the TRIGGER button.
2. If you are using the laser, adjust your aim
until the red spot is on the target.
The temperature will be shown on the
display.
3. Release the TRIGGER button when you
have finished taking a reading.
The display will show HOLD, indicating that
the temperature shown is the last
temperature recorded.
4. The display will also show the maximum or
minimum temperature recorded while the
TRIGGER button was pressed. To toggle
between maximum and minimum, press the
MODE button.
Seven seconds after the last button press the
instrument will switch off automatically and the
reading will be lost.
4 MEASUREMENT AREA
Your Elcometer 214L measures a circular spot.
The diameter of this spot varies with distance
from the lens.
Distance from lensSpot size (diameter)
< 140 mm13 mm
> 140 mm < 1000 mmsee diagram below
> 1000 mmdistance divided by 20
The target area must be at least as large as the
spot size.
6
5 EMISSIVITY
TemperatureInfrared energy
1
Emissivity
--------------------------
×=
The intensity of infrared radiation which is emitted
by a body depends not only upon the
temperature of the body, but also upon the ability
of the surface of the body to emit infrared energy.
This ability of the surface of the body to emit
infrared energy is characterised by a factor
known as the ‘emissivity’ of the material.
Your Elcometer 214L Infrared Digital
Thermometer has a pre-set fixed emissivity value
of 0.95; this value is very common for most
organic materials and painted or oxidised
surfaces.
The fixed emissivity value of 0.95 is shown in the
bottom right hand corner of the display.
6 HINTS AND TIPS
•Shiny or metallic surfaces may result in
inaccurate readings. To prevent this, cover
the measuring surface with either matt black
paint or with a suitable tape. Remember to
leave extra time for the surface covering to
reach the temperature of the body being
measured before taking a reading.
•Infrared thermometers cannot measure the
temperature of objects through transparent
materials such as glass or plastic.
•Always keep the lens clear of steam, dust,
smoke or other particles which would
otherwise cause inaccurate measurement.
7
7 TROUBLESHOOTING
Code/faultProblemAction
HHHAbove
Maximum
measuring
limit
LLLBelow
Minimum
measuring
limit
Blank
display
Battery may
be exhausted
Battery may
Laser does
not work
be exhausted
Laser is
switched off
8 STORAGE
Choose target
within
measuring
specifications
Choose target
within
measuring
specifications
Check/replace
battery
Check/replace
battery
Switch on laser
(see page 4)
This gauge incorporates a Liquid
Crystal Display (LCD). If the display is
heated above 60°C (140°F) it may be
damaged. This can happen if the gauge is left in
a car parked in strong sunlight.
Remove the batteries from the gauge and store
them separately if the gauge is to remain unused
for a long period of time. This will prevent damage
to the gauge in the event of malfunction of the
batteries.
8
9 TECHNICAL SPECIFICATION
Performance
Measurement range:-32°C to 420°C
(-20°F to 788°F)
Accuracy
Repeatability 0°C to 420°C: ±0.5% or ±0.7°C
a
0°C to 420°C: ±1% or ±1°C
-32°C to 0°C: ±1°C ±0.07°C/°C
-32°C to 0°C: ±0.7°C ±0.05°C/°C
Resolution (optical):20:1
13 mm ≤ 140 mm
(distance:spot)
Resolution (display):0.2°C (0.5°F)
Response time (95%):300 ms
Emissivity:0.95 (fixed)
Laser:<1 mW class 2
9 mm offset
Spectral range:8 µm to 14 µm
Environmental
Ambient temperature:0°C to 50°C
(-32°F to 122°F)
Storage temperature:-20°C to 60°C
(without battery)(-4°F to 140°F)
Relative humidity:10% to 95%
(at <30°C)
Physical
Weight:150 g (5.3 oz)
Dimensions:190 x 38 x 45 mm
Battery:9 V, PP3/6LR61
Battery life:40c hours
a. Strong RF fields may adversely affect
measurement accuracy.
(7.5" x 1.5" x 1.8")
b
9
10 MAINTENANCE
The Elcometer 214L Infrared Digital
Thermometer is designed to give many years
reliable service under normal operating and
storage conditions.
Regular calibration checks over the life of the
Elcometer 214L Infrared Digital Thermometer are
a requirement of quality management procedures
e.g. ISO 9000 and other standards. For checks
and certification contact Elcometer or your local
Elcometer supplier.
The instrument does not contain any userserviceable components. In the unlikely event of
a fault, the instrument should be returned to your
local Elcometer supplier or direct to Elcometer.
Details of Elcometer offices around the world are
given on the outside cover of these operating
instructions. Alternatively visit the Elcometer
website, www.elcometer.com
11 RELATED EQUIPMENT
In addition to the Elcometer 214L, Elcometer
produces a wide range of other test equipment.
Users of the Elcometer 214L may also benefit
from the following Elcometer products:
•Elcometer Pocket Digital Thermometer
•Elcometer Infrared Thermometers
•Elcometer Bi-metallic Thermometers
For further information contact Elcometer, your
local supplier or visit www.elcometer.com
b. Alkaline batteries must be disposed of carefully to
avoid environmental contamination. Please consult
your local environmental authority for information
on disposal in your region.
Do not dispose of any batteries in fire.
c. 20 hours with laser and backlight on 50%
10
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.