SD card real time Data Recorder
10 Light Source select , Auto range 0 to 100,000 LUX
LED LIGHT METER
Model : ELX-1148SD
Your purchase of this
LED LIGHT METER with
SD CARD DATA LOGGER
marks a step forward for you
into the field of
precision measurement.
Although this meter a
complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.
OPERATION MANUAL
by ELBRO AG - Giorgio Bovenzi 2018
TABLE OF CONTENTS
1. FEATURES..............................................................................
..................................................................
1
2. SPECIFICATIONS........................................................................................
..................................................
2
3. FRONT PANEL DESCRIPTION...................................................................................
.................................................
6
4. MEASURING PROCEDURE.....................................................................................
.................................................
7
4-1 Function selection/Measurement..................
..................................................................
7
4-2 Light Meter Measurement....................................................................................
..................................................
7
4-3 Light Source Selection....................................................................................
..................................................
4-4 Type K/J thermometer Measurement....................................................................................
9
4-5 Data Hold..................................................................................................
.........................................................
10
4-6 Data Record ( Max./ Min. reading ).............................................................................
.........................................................
10
4-7 LCD Backlight ON/OFF...........................................................................................
...........................................
11
5. DATALOGGER............................................................................................
......................................................
11
5-1 Preparation before execute datalogger function....................
..................................................................
11
5-2 Auto Datalogger ( Set sampling time ≧ 1 second )................
..................................................................
12
5-3 Manual Datalogger ( Set sampling time = 0 second )................
..................................................................
13
5-4 Check time information.............................................................
..................................................................
13
5-5 SD Card Data structure.......................................
..................................................................
14
6. Saving data from the SD card to the computer.......................
..................................................................
15
7. ADVANCED SETTING.............................................
..................................................................
16
7-1 Set clock time ( Year/Month/Date, Hour/Minute/ Second ).......
..................................................................
17
7-2 Set sampling time ...................................................
..................................................................
18
7-3 Auto power OFF management ....................
..................................................................
18
7-4 Set beep Sound ON/OFF...........................
..................................................................
18
7-5 Decimal point of SD card setting.........................
..................................................................
19
7-6 SD memory card format...............................
..................................................................
19
7-7 Select the temperature unit to ℃ or ℉ .................
..................................................................
7-8 Select the thermometer type to Type K or Type J.................................................................
20
8. POWER SUPPLY from DC ADAPTER...................
..................................................................
21
9. BATTERY REPLACEMENT...........................................................................................
....................................
21
10. SYSTEM RESET............................................................................................................
.......................................
22
11. RS232 PC serial interface.....................................................................................
..............................................................
22
12. Optional Type K Temp. probe.....................................................................................
..............................................................
24
13. PATENT.................................................................................................................
......................................
1. FEATURES
* 3 ranges, 2,000/20,000/100,000 LUX.
* LUX & Foot Candle unit selection with default.
* Auto range for light measurement.
* Spectrum of photo sensor meets C.I.E..
* Light measurement with zero adjustment by push button.
* Separate probe, easy for operation of different
measurement environment.
* Measure White, Red, Yellow, Green, Blue, and Purple LED
and Standard Lighting in Lux or Foot-Candle units.
* Type K, Type J thermocouple thermometer.
* Real time SD memory card Datalogger, it Built-in Clock
and Calendar, real time data recorder , sampling time set
from 1 second to 3600 seconds.
* Manual datalogger is available ( set the sampling
time to 0 ), during execute the manual datalogger
function, it can set the different position ( location ) No.
( position 1 to position 99 ).
* Innovation and easy operation, computer is not
need to setup extra software, after execute
datalogger, just take away the SD card from the
meter and plug in the SD card into the computer,
it can down load the all the measured value with
the time information ( year/month/date/
hour/minute/second ) to the Excel directly, then
user can make the further data or graphic
analysis by themselves.
* SD card capacity : 1 GB to 16 GB.
* LCD with green light backlight, easy reading.
* Can default auto power off or manual power off.
* Data hold, record max. and min. reading.
* Microcomputer circuit, high accuracy.
* Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface.
01
2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).
Measurement/ Light : LUX, Feet candle ( Ft-cd )
Unit Type K/J thermometer : ℃ or ℉.
Light Sensor The exclusive photo diode & color correction filter,
Structure spectrum designed to meet C. I. E.
Light Source select L 0~ L9 Light Source selection.
Zero Adj. By push button.
* Light
Datalogger Auto 1 second to 3600 seconds
Sampling Time
@ Sampling time can set to 1 second,
Setting range
but memory data may loss.
Manual Push the data logger button
once will save data one time.
@ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Memory Card SD memory card. 1 G to 16 G.
Advanced
* Set clock time ( Year/Month/Date,
setting
Hour/Minute/ Second )
* Decimal point of SD card setting
* Auto power OFF management
* Set beep Sound ON/OFF
* Set thermometer type to Type K or Type J
* Set temperature unit to ℃ or ℉
* Set sampling time
* SD memory card Format
Temperature Automatic temp. compensation for the
Compensation type K/J thermometer.
02
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time Approx. 1 second.
of Display
Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
Operating 0 to 50 ℃.
Temperature
Operating Less than 85% R.H.
Humidity
Power Supply * Alkaline or heavy duty DC 1.5 V battery
( UM3, AA ) x 6 PCs, or equivalent.
* DC 9V adapter input. ( AC/DC power
adapter is optional ).
Power Current Normal operation ( w/o SD card save
data and LCD Backlight is OFF) :
Approx. DC 6.5 mA.
When SD card save the data but and
LCD Backlight is OFF) :
Approx. DC 30 mA.
* AC/DC power adapter is optional.
consumption will increase approx.
16 mA.
Weight 346 g/0.76 LB.
Dimension 182 x 73 x 47.5 mm
(7.1 x 2.9 x 1.9 inch)
Standard * Instruction manual.............................. 1 PC
Accessories * Light sensor with protective
Included cover............................................ 1 PC
03
Optional SD Card ( 1 GB )
Accessories SD Card ( 2 GB )
Type K thermocouple probe.
AC to DC 9V adapter.
USB cable, USB-01.
RS232 cable, UPCB-02.
Data Acquisition software,SW-U801-WIN.
Hard carrying case, CA-06.
2-2 Electrical Specifications (23±5 ℃)
Light meter
Measurement Range
Display
2,000 LUX 0 - 1,999 LUX
LUX 20,000 LUX 1,800 - 19,990 LUX
@ auto range 100,000 LUX 18,000 - 99,900 LUX
200 Ft-cd 0 - 186.0 Ft-cd
Feet-candle 2,000 Ft-cd 167.0 - 1,860.0 Ft-cd
@ auto range 10,000 Ft-cd 1,670.0 - 9,290.7 Ft-cd
Range Resolution Accuracy
2,000 LUX 1 LUX
20,000 LUX 10 LUX ±(4 %+2 dgt)
100,000 LUX 100 LUX
200 Ft-cd 0.1 Ft-cd
2,000 Ft-cd 1 Ft-cd
±(4 % +2 Ft-cd)
10,000 Ft-cd 10 Ft-cd
±(4 %+20 Ft-cd)
Note : Accuracy tested by a standard parallel light
tungsten lamp of 2856 K degree temperature.
04
Type K/J thermometer
Sensor Resolution Range Accuracy
Type
Type K 0.1 ℃ -50.0 to 1300.0 ℃ ± ( 0.4 % + 0.5 ℃ )
-50.1 to -100.0 ℃ ± ( 0.4 % + 1 ℃ )
0.1 ℉ -58.0 to 2372.0 ℉ ± ( 0.4 % + 1 ℉ )
-58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 ℉ )
Type J 0.1 ℃ -50.0 to 1200.0 ℃ ± ( 0.4 % + 0.5 ℃ )
-50.1 to -100.0 ℃ ± ( 0.4 % + 1 ℃ )
0.1 ℉ -58.0 to 2192.0 ℉ ± ( 0.4 % + 1 ℉ )
-58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 ℉ )
@ Above specification tests under the environment RF Field Strength
less than 3 V/M & frequency less than 30 MHz only.
05
3. FRONT PANEL DESCRIPTION
3-1 Display 3-13 Reset Button
3-2 Power Button ( Backlight Button ) 3-14 DC 9V Power Adapter Input Socket
3-3 Hold Button 3-15 Battery Compartment/Cover
3-4 REC Button 3-16 Battery Cover Screws
3-5 UNIT Button ( ▲ Button ) 3-17 Stand
3-6 FUNCTION Button ( ▼ Button )
3-18 Tripod Fix Nut
3-7 SET Button ( Clock Button ) 3-19 Probe Plug
3-8 LOG Button ( ENTER Button ) 3-20 Sensor Handle
3-9 Probe input socket 3-21 Light Sensor
3-10 Type K/J thermometer socket 3-22 Cover of Light Sensor
3-11 SD card socket
3-12 RS-232 Output Terminal