GENERAL
Congratulations on the purchase of your CO-STOP: The ideal protection
against carbon monoxide (CO) poisoning suitable for apartments, private
residences, chalets, hotels, stores, office buildings, and so on. This product is a
highly stable carbon monoxide detector designed for early signalling of
carbon monoxide and disconnection of the source producing the carbon
monoxide. The CO-STOP is equipped with an advanced semicond uctor sensor
and MCU processor. The CO-STOP represents stable functioning, sustainability
and easy installation.
Carbon monoxide is an odourless gas which can also not be seen or tasted. It
is generated at incomplete combustion within organic driven appliances
which use for example oil, gas or wood for combustion. Carbon monoxide
sticks to red blood cells 200 times better than oxygen does, quickly resulting
into negative consequences. Below we illustrate the possible consequences of
breathing in carbon monoxide, depending on the amount taken in and
duration of exposure.
This manual contains all necessary information to easily install the CO -STOP. We
kindly urge you to read this manual carefully before installa tion. Keep this
manual safe and pass it on to any possible new owner of your CO-STOP.
MAKE SURE YOUR CO-STOP IS INSTALLED CORRECTLY BY A
COMPETENT PERSON AND CHECK FREQUENTLY BY USING THE
TEST BUTTON!
ENVIRONMENTAL PROTECTION
Discarded electric devices should never be disposed of
together with regular household refuse. Always recycle
the product if possible.
Turn to your local environmental services or to the selling point for more
information on recycling. Do not throw away empty batteries, but turn them in
as being chemical waste.
WARNINGS
The CO-STOP cannot be considered as an alternative for installation and
maintenance of smoke detectors. The CO-STOP does not detect smoke or fire.
Besides carbon monoxide, the CO-STOP does not detect any poisonous gas.
The CO-STOP is designed for indoor use and in normal circumstances. It is not
designed to monitor the norm in industrial buildings. The CO -STOP is not suited
for installation in dangerous environments as defined in the national
requirements for electric equipment. Individuals with medical issues and
affections, should consider using notification devices which p roduce acoustic
and visual signals at a carbon monoxide concentration of less than 30 PPM.
The CO-STOP is designed to detect carbon monoxide coming from all possible
devices and machines which are defective or not working properly. Installing
the CO-STOP should never be considered as an alternative for a proper
working installation and a proper usage and maintenance of
devices/machines burning fuel or suitable ventilation and draining system(s).
CHARACTERISTICS
Highly reliable CO sensor
Automatic reset after alarm
Automatic malfunction indicator
Acoustic and visual alarm signal
Disconnection carbon monoxide source
MCU processor
SMT-technology
PRODUCT INFORMATION
Image 1.1: CO-STOP
TECHNICAL SPECIFICATIONS
Operating voltage: 110V-230V AC
Rated power: ≤3W (220V AC power supply)
Warm-up time: 3-5 minutes
Alarm level: >50PPM* during 60-90min.
>100PPM* during 10-40min.
>300PPM* during <3min.
Alarm indicator: Red LED flash
Malfunction indicator: Constant yellow LED and long buzz
Alarm sound: ≥ 85db (within 1 meter)
Operating temperature: -10°C to 50°C
Environmental humidity: ≤ 95% RH (no condensation)
Installation: Wall mounted
Alarm: Acoustic and visual alarm signal and
disconnection of the CO source
Dimensions: 118,5*82*43 mm
Execution criteria: GB15322.2-2003
Produced according to the European standard 50291-1:2010/A1:2012
* Parts Per Million (parts of CO molecules per million molecules of air)
INSTALLATION & OPERATION
1. Install the CO-STOP on a wall with a minimum distance of 30 cm from the
ceiling, with a maximum of 300 cm from the CO source and on a minimum
height of 150 cm. from the floor (see image 1.2 below).
Image 1.2: Installing CO-STOP
2. Firmly install the wall mount by fixing the screws (optionally in combination
with the plugs) into the wall (see image 1.3).
Image 1.3: Fixing wall mount
3. Install the CO-STOP on the wall mount.
4. All wiring should meet the local regulations. Wires should have the desired
dimensions and colours to avoid malfunction. Improper installation can lead to
a malfunction in the alarm in case of a gas leak.
5. Disconnect the boiler from the mains by unplugging the power cord.
6. Insert the plug of the boiler in the switch plug of the CO-STOP.
7. Then insert the switch plug of the CO-STOP in the socket, after which the
detector will go into the self-test status. The power indicator will light up and
the CO detector will flash red for a second accompanied by a Di -sound. The
circuit will now warm up. The CO indicator will start flashing green. After
approx. 3-5 minutes the circuit will be warmed up. The CO indicator will turn off
and the detector now works.