No part of this documentati on and the rela ted software and firmware may be reproduced, rewritten, stored on a retr ieval system,
transmitted or translated into any other language or computer language without the express written consent of ELAU AG.
All possible measures were taken to ensure the that this product
documentation is complete and correct. However, since hardware
and software are continuously improved, ELAU makes no representations or warrant ies wi th resp ect to t he conte nt s of thi s product
documentation.
Trademarks
PacDrive is a registered trademark of ELAU AG.
All other trademarks mentioned are the exclusive property of their
manufacturers.
Korrekturausdruck
ELAU AGELAU Inc.
Dillberg 12165 E. Commerce Drive
D-97828 MarktheidenfeldSchaumburg, IL 60173 - USA
7.9Form for Error Report ........................................................................... 77
PDM_OperaManMC-4_us0101IVZ.FM
page 4PacDrive MC-4ELAU AG
Page 5
1 On this manual
1.1 Introduction
Before using ELAU components for the first time, you should
familiarize yourself with this operating manual.
In particular, observe the safety notes described in chapter 2.
Only persons who meet the criteria for "Selection and Qualification
of Staff" (see chapter 2.4) are allowed to work on ELAU
components.
One copy of this manual has to be available for st af f worki ng on the
components at all times.
This manual helps you use the component safely and expertly and
as directed.
1.1 Introduction
Observe this manual. This will help to avoid risks, reduc e repair
costs and down times and incr ease the l ifeti me and r eliabi lity of t he
products.
You also need to observe the valid rules for the prevention of
accidents and for environmenta l protection in the country and place
where the device is used.
PDM_VerwendStd_us.FM
ELAU AGPacDrivepage 5
Page 6
1 On this manual
1.2 Symbols, Signs and Forms of Depiction
The following symbols and signs are used in this document:
DepictionMeaning
–
9
Italics
Serif font
First level enumeration sign.
Second level enumeration sign.
Action symbol: The text following this symbol
includes an instruction for action. Execute the
instruction actions in the given order, from top to
bottom.
Result symbol: The text following this symbol
contains the result of an action.
If the describing text contains special terms (e.g.
parameters) then they are written in italics.
If the manual contains prog ram cod e, i t is marked by
Serif font.
Information symbol: This symbol marks notes and
useful tips for using the product.
Warning sign
relevant places. They are marked with this symbol.
: Safety notes can be found in the
After this symbol, information about contents of the
chapter follows as guideline assistance.
Table 1-1: Symbols, signs and forms of depiction
page 6 PacDriveELAU AG
PDM_VerwendStd_us.FM
Page 7
Korrekturausdruck
2.1 Basics
2 General Safety Notes
This chapter contains general requirements for working safely.
Every person using ELAU components or working on ELAU
components has to read and observe these general safety not es.
If activities involve a residual risk, you will find a clear note in the
respective places. The note describes the ri sk that may occur and
preventive measures to avoid that risk.
2.1 Basics
The ELAU components are built according to the state of
technology and generally accepted safet y rules. Never theless, their
use may cause a risk to life and limb or material damage if:
you do not use the components as directed
work on the components is not done by experts or inst ructed
staff
you inexpertly alter or modify a component
you fail to test the protective measures in place af te r inst allat ion,
commissioning or servicing
you do not observe the safety notes and regulations.
Only operate the components in perfect techni cal condition as
directed, in regard to safety and risks and observe this manual .
The flawless and safe operation of the components requires
appropriate transport, storage, mounting and installation as well as
careful maintenance.
In case of any circumstances that impair the safety and cause
changes in the operating behavior, immediately put the
component(s) to a stop and inform the service staff in charge.
In addition to this manual, observe
the prohibiting warning an d mandatory signs on the component,
the connected components and in the switching cabinet
the relevant laws and regulations
the operating manuals of the other components
the universally valid local and national rules for safety and the
prevention of accidents.
PDM_SicherhMax_us_neu.fm
ELAU AGPacDrivepage 7
Page 8
2 General Safety Notes
2.2 Depiction of Safety Notes
Risk categories
The safety notes in this manual are grouped into different risk
categories. The table below shows which risk and possible
consequences the symbol (pictograph) and the signal words
indicate.
PictographSignal wordDefinition
Indicates an immediately dangerous
DANGER!
WARNING!
situation that will result in death or very
serious injuries if the safety rules are
not observed.
Indicates a possible dangerous
situation that can result in serious
injuries or major material damage if the
safety rules are not observed.
Korrekturausdruck
CAUTION!
Table 2-1: Risk categories
Indicates a possible dangerous
situation that might result in material
damage if the safety rules are not
observed.
page 8 PacDriveELAU AG
PDM_SicherhMax_us_neu.fm
Page 9
2.3 Use as Directed
The ELAU components are designed for installation in a machine/
plant or for combination with other components to form a machine/
plant. The components may onl y be used under the ins ta llation and
operating conditions descri bed in this documen tation. You must use
the accessories and ancillary parts (components, cables, etc.)
mentioned in the documentation. You must not use any foreign
objects or components that are not explicitly approved by ELAU.
"Use as directed" also means that you
observe the Operating Manuals and other documentations (see
appendix),
observe the instructions for inspection and maintenance.
2.3 Use as Directed
Korrekturausdruck
Use other
than directed
The operating conditions at the installation location must be
checked on the basis of the given technical data (performance
information and ambient conditions) and observed.
The device must not be put into operation until it is gua ranteed th at
the useable machine or the plant in which the motor is inst alled
meets in its entirety EC directive 98/37/EC (machine directive).
In addition, observe the followi ng norms, di recti ves and r egulations:
DIN EN 60204 Safety of machines:
Electrical equipment of machines.
DIN EN 292 part 1 and part 2 Safety of machines:
Basics, general design guidelines.
DIN EN 50178 Equipment of high-voltage plant s with electronic
operating means.
EMC directive 89/336/EEC
PDM_SicherhMax_us_neu.fm
ELAU AGPacDrivepage 9
Page 10
2 General Safety Notes
2.4 Selection and Qualification of Staff
This manual is aimed exclusively at technical ly qual ified staff with
detailed knowledge in the field of automation technology.
Only qualified staff can recognize the significance of safety notes
and implement them accordingly.
This manual is aimed in particular at desi gn an d application
engineers in the fields of mechanical and electrical engineering, at
programmers, service and commissioning engineers.
Working on
electrical
equipment
Work on electrical equipment must only be done by qualifi ed
electricians or by instructed staff supervised by an electrician
according to the electrotechnical rules.
An electrician is a person who due to his vocational training, knowhow and experience as well as knowledge of the valid regulations,
is able to:
evaluate the work he is supposed to do
identify potential risks
implement suitable safety measur es.
2.5 Residual Risks
We minimized the health risk for people by means of appropriate
construction and safety technology. Nevertheless, there is a
residual risk, since the components work with electrical current and
voltage.
Korrekturausdruck
page 10 PacDriveELAU AG
PDM_SicherhMax_us_neu.fm
Page 11
Korrekturausdruck
2.5 Residual Risks
2.5.1 Installation and Handling
WARNING!
Risk of injury while handling the unit!
Risk of injury due to squeezing, cutting or hitting!
Observe the universally valid construction and safety rules for
handling and installation.
Use suitable insta llation and transport facilities and use them
professionally. If necessary, use special tools.
Take precautions against squeezing.
If necessary, use suitable protective clothing (e.g. safety
glasses, safety shoes, protective gloves).
Do not stay under pending loads.
Remove any leaking liquids from the floor immediately to avoid
skidding.
PDM_SicherhMax_us_neu.fm
ELAU AGPacDrivepage 11
Page 12
2 General Safety Notes
2.5.2 Touching Electrical Parts
Touching parts carrying a voltage of 50 Volts or higher can be
dangerous. When electric appliances are operated, certain parts of
these appliances inevitabl y carry a dangerous voltage.
DANGER!
High voltage!
Life hazard!
Observe the valid construction and safety regulations for
working on high-voltage units.
After installation, check the fixed connection of the earth
conductor on all electric appliances according to the connection
plan.
Operation, even for short-term measuring and test purposes, is
only permitted with an earth conductor firmly connected to all
electric components.
Disconnect the unit from mains or power supply and lock it ou t
before accessing electrical parts with voltages exceeding 50
Vol t s. Af te r switching off, wait at least 5 minutes before touching
any components.
Do not touch electrical connections of the component s while t he
unit is on.
Before switching the unit on, cover all voltage carrying parts to
prevent accidental contact.
Provide a protection against ind ir e ct touching (EN 50178 / 1998
section 5.3.2).
Korrekturausdruck
DANGER!
High leak current!
Life hazard!
The leak current is greater than 3.5 mA. Therefore the units
must have a firm connection to the power grid (a ccor ding to DIN
EN 50178 / 1998 - equipment of high-voltage systems).
page 12 PacDriveELAU AG
PDM_SicherhMax_us_neu.fm
Page 13
Korrekturausdruck
2.5.3 "Safely Separated Low Vo ltages"
PELV
Signal voltage and control voltage of the PacDrive units are <33 V.
P
rotective-Extra-
L
ow-Voltage
In this range, the specification as PELV system according to IEC
364-4-41 includes a protective measure against directly and
indirectly touching dangerous voltages by means of a "safe
separation" from the primary to the secondary side in the plant/
machine. ELAU urgently recommends to execute the plant/
machine w ith safe separa t ion.
DANGER!
High voltage due to wrong connection!
Life hazard or risk of serious injury!
Only units, electric components or cables with a sufficient safe
separation of the connected power supplies according to EN
50178 / 1998 (equipment of high-voltage systems with electron ic
operating means) may be connected to the signal voltage
connections of these components.
Make sure that the existing safe separ ation is retained
throughout the entire current circuit.
2.5 Residual Risks
FELV
Functional-
xtra-Low-
E
V
oltage
When using ELAU components in systems that do not include a
safe separation as a means of protection against directly or
indirectly touching dangerous voltages, all connections and
contacts (e.g. MAx-4, Sub-D connec tor, serial inerface) that do not
comply with protection class IP2X must be permanently covered.
The cover or device connection must be arranged such, that it can
only be removed with the help of a tool. The protective measure
must be observed on all connected devices.
PDM_SicherhMax_us_neu.fm
ELAU AGPacDrivepage 13
Page 14
2 General Safety Notes
2.5.4 Potentially Dangerous Movements
There can be different causes for potentially dangerous
movements:
mistakes in wiring or cable connection
software errors
faulty components
errors in measuring value and signal encoders
operating mistakes
The protection of people must be insured by superior means or
monitoring on the plant side. You must not rely on the internal
monitoring in the drive components alone. Monitoring or measures
must be provided according to a risk and er ror analysi s by the plant
builder according to the specifi c conditions of the plant. The valid
safety rules for the plant have to be included in this process.
Korrekturausdruck
DANGER!
Potentially dangerous movements!
Life hazard, serious injury or material damage!
No persons are allowed within the motion range of the machine.
This must be ensured with devices like protective fences, grids,
covers or photoelectric barriers.
The fences and covers must be sufficiently strong to withstand
the maximum possible motion energy.
The emergency stop switch must be located very close to the
operator. Check the operation of the emergency stop before
starting up the plant.
Secure against unintentional start by enabling the mains
contactor of the drives via an emergency off circuit or by means
of the function 'safe stop'.
Before accessing the danger zone, bring the drives to a safe
stop.
To work on the plant, the power must be turned off and locked
out.
Avoid operating high-frequency remote-control and radio
devices in the vicinity of the plant's electronics and connecting
wires. If the use of those devices i s inevitabl e, check system and
plant for possible malfunctions before the first operation. In
some cases, a special EMT check may be necessary.
page 14 PacDriveELAU AG
PDM_SicherhMax_us_neu.fm
Page 15
Korrekturausdruck
3.1 Drive Concepts of Packaging Machines
3 System Overview
3.1 Drive Concepts of Packaging Machines
Modern machine concepts in the packaging industry are
characterized by the need for high dynamism, flexibi lity, modularity
and efficiency. Packaging machines were traditionally equipped
with a mechanical vertical shaft, which drove the secondary
motions in the machine, usually with mechanical components with
complicated motion functions. Designing such a machine, flexible
for different product s is a highly complex task . Even minor changes
in the packaging process, p articularly in case of a product change,
require major modifications and standstill time.
Packaging machines with electronic vertical shafts permit full
flexibility. Electronic servo drive systems replace cam and coupling
gears and a virtual electronic vertical shaft ensures that the motion
axes are synchronous. Any pulse and angle synchronous
movements are determined by a central control.
Unplanned machine states, such as stop or emergency off
situations or initialization movements can be realized
synchronously. Dynamic changes of the goods to be packed or the
packaging material in the plant, (like slippage of the products to be
packed or expansion of the packaging material) can be registered
by sensors while the machine is running and eliminated by
modifying the corresponding drive movements. This development
substantially changes and highly simplif ies the classical mechanical
machine concept. The structure of the packaging machine can be
broken down into modules that are easy to apply and can be
standardized.
PDM_SysUebers_us.FM
ELAU AGPacDrive MC-4page 15
Page 16
3 System Overview
Korrekturausdruck
Fig. 3-1: Sketch of a packaging machine
page 16 PacDrive MC-4ELAU AG
PDM_SysUebers_us.FM
Page 17
Korrekturausdruck
3.2 St ructure of the PacDrive™ Automation
3.2 Structure of the PacDrive™ Automation Syst em
The PacDrive™ automation system offers a technically and
economically optimal solution for electronic packaging machines.
PacDrive™ consists of an ef ficient PC-based control, the PacDrive
Controller and the digit al MC-4 ser vo dri ve which inc lude the mains
connection unit, the end-st age power and t he serv o regulator of the
individual axes (Fig. 3-2).
The PacDrive Controller is the intelligent head of the system, and is
based on an industrial PC. The PacDrive Controller synchronizes
and coordinates the motion functions of the packaging machine.
Using an IEC 1131-3 soft PLC, it ventures into applications
previously reserved for standard PLCs. The individual PLC or
positioning tasks can be broken down into sever al parallel tasks,
which are implemented with the EPAS-4 programming environment
according to the IEC 1131-3 standard. Up to 40 servo axes can be
connected to a PacDrive Controller and supplied with positioning
data.
The circular digital SERCOS real-time bus realizes the safe data
exchange with the servo drive MC-4. Due to the use of optical fiber
technology, the data bus is insensitive to electromagnetic
disturbances and cyclically supplies the decentralized servo drive
MC-4 with new set values at a data rate of 4MBaud. All internal
states of the axes can be checked via the real-time bus an d
processed in the PacDrive Controller.
In addition to digital and analog inputs and outputs, the PacDrive
Controller has two serial interfaces and one Ether net interface. A
variety of process visualizati on and control systems can be
connected to the PacDrive™ system via the integrated OPC
interface. Further peripheral component s can be connected via field
bus interface modules. The PacDrive Controller can act as a field
bus master or slave.
The international field bus standards CANopen, PROFIBUS-DP
and DeviceNet are supported. The built-in inter faces enable remote
diagnosis via telephone modem or Internet. Via TCP/IP, PC’s can
communicate with the PacDrive Controller and diagnose the state
of the control directly.
PDM_SysUebers_us.FM
ELAU AGPacDrive MC-4page 17
Page 18
3 System Overview
3.3 Concept
Korrekturausdruck
Fig. 3-2: System overview of the PacDrive™ automation concept
Alternatively, the PacDrive Controller can be connected to a
conventional PLC via a field bus.
page 18 PacDrive MC-4ELAU AG
PDM_SysUebers_us.FM
Page 19
Korrekturausdruck
3.4 Components
3.4 Components
Automation Toolkit EPAS-4
EPAS-4 has extensive and proven functions and tools. A key
advantage of EPAS-4 is, that all components are integrated and
intuitive.
For you as a user this means:
Quick familiarization, easy handling, all tools integrated.
LibrariesELAU maintains extensive libraries geared to the packaging
industry, helping you obtain cost effective and speedy answers to
any concern. They will also help you to improve the quality of your
user programs.
Highlights of the EPAS-4 Automation Toolkit
Runs under Windows (recommended WinXP)
Programming language IEC 61131-3
SCOPE tool (oscilloscope functions)
Diagnostic tool
very good debugging features
serial or TCP/IP connection to the PacDrive Controller.
PacDrive Controller Family
The PacDrive Controller, a microprocessor-based contr ol hardware
with VxWorks real-time operati ng system, realizes the PLC and
motion functions.
A PacDrive Controller synchronizes, coordinates and generat es the
positioning functions for a maximum of:
in a food and packaging machine.
For HMI tasks, various standard HMIs are used. Whether low-cost
clear text or IPC - it’s no problem for the flexible PacDrive
Controller.
The PacDrive Controller P600 is equipped with a complete PC.
Due to this PC based technologie, the P600 can also be used for
HMI applications.
PDM_SysUebers_us.FM
ELAU AGPacDrive MC-4page 19
Page 20
3 System Overview
Servo drive PacDrive MC-4
Leading-edge
technology
The digital servo drive MC-4 is characterised by its compact and
autonomous structure, suit able for wall mounting as well as its
leading-edge technology. The innovative MC-4 has the mains
supply unit, end stage and software regulator for one axis
integrated in a compact casing. Since it communicates with the
PacDrive Controller only via f ibre optic al cable, i t is also suit abl e for
a decentralized structure. It requires no user program. It comes
with single- and multi-turn processing features as standard and
configures itse lf with the hel p of the electro nic name plate in t he SM
motor.
The highlights of the MC-4 MotorController
World-wide voltage range
Integrated mains supply unit
Max. power 34.5 / 69 kVA
Automatic motor recognition
Minimum size
Safety input Inverter Enable
250 % overload
Integrated SERCOS interface
few types
Korrekturausdruck
Highly
dynamic servo
motors
SM-Motor
Machines with fast cycle rates require highly dynamic AC servo
motors. The SM motor series offers you as a user an optimum
motor concept for your food and packagi ng machines. The dynamic
brushless servo motors ar e furnished with high-resol ution encoders
(single-turn or multi-turn) and electronic name plate. Smooth
surface and compact size meets the requirements of the target
market.
The highlights of the SM motors
Low mass moment of inertia
4-fold overload
Reliable high-voltage technology
Leading-edge magnetic technology
High-resolution single- or multi-turn encoder
Electronic name plate
Plug in junction box
IP 65 protection
page 20 PacDrive MC-4ELAU AG
PDM_SysUebers_us.FM
Page 21
Tran spor tation, Storage, Unpacking
4 Transportation, Storage, Unpacking
4.1 Transportation
Avoid shocks.
Immediately check units for transport damage and inform your
transport company, if necessary.
4.2 Storage
Store units in a clean, dry place.
Korrekturausdruck
Storage conditions:
air temperature between - 25 °C and + 70 °C.
temperature fluctuations max. 30 K per hour.
PDM_OpMaMC-4_04_us.FM
ELAU AGPacDrive MC-4page 21
Page 22
Transportation, Storage, Unpacking
4.3 Unpacking
Check whether the delivery is complete.
Check all units for transport damage.
Type plate
The type plate contains all necessary information:
logistic type plate
technical type plate
Korrekturausdruck
Fig. 4-1: Type plate on PacDrive MC-4
Article name
Article number
Serial number
MC-4/11/10/400
13130247
587089.0010 Y07SW: 00.12.31
#1234567
HW: D0H503
Production date
Fig. 4-2: logistic type plate of a PacDrive MC-4
Article name
Fig. 4-3: technical type plate of a PacDrive MC-4
SL
Hardware version
Software version
BLD: V3.30
Bootloader version
Made in Germany
PDM_MC4_Typenschild_logis_us.FH8
PDM_MC4_Typenschild_techn_us.FH8
PDM_OpMaMC-4_04_us.FM
page 22 PacDrive MC-4ELAU AG
Page 23
5 Maintenance
Recognizing and clearing an error quickly hel p s to keep t he relat ed
production loss down to a minimum.
The diagnosis messages of the PacDrive™ system, which can be
checked using EPAS-4, make it possible to look for errors deliberately and effectively.
In case of an error, defective components can be exchanged with
no problem. This ensures that the problem can be solved quickly
and operation can be resumed soon. This work must be done by
qualified maintenance staff only.
When returning a defective unit to the ELAU customer service,
please complete the attached err o r report form.
Maintenance
Korrekturausdruck
5.1 Spare Parts, Components
Stock keeping of spare parts:
Keeping a stock of the essential components is a key prerequisite
for the permanent functionality of the equipment.
ATTENTION!
Device com pat ib ili ty !
System does not operate accurate after exchanging components.
Only units with identical hardwa re configuration and identical
software version may be exchanged.
When ordering spare parts, please give the following data:
product name: e. g. MC-4/11/10/400
article number:e. g. 13130247
hardware version:e. g. HW: 504001
software version:e. g. SW: 00.05.00
NOTE
You can find this information on the type plate of the equipment
(see Fig. 4-2) and in the configuration of the PacDrive™ systems.
PDM_OpMaMC-4_05_us.FM
ELAU AGPacDrive MC-4page 23
Page 24
Maintenance
5.2 Repairs
By all means complete the attached error report form when returning
defective components.
You can also make a photocopy of the error report form and use it as
a fax message.
ATTENTION!
Electro static discharge!
Components may be damaged!
Electronic parts may only be returned in the original or a compa-
rable packaging. In any case the components must be wrapped
in an ESD packaging/foil. Otherwise you will lose your warranty
rights.
In addition to the notes below, please observe the inf ormation of the
machine producer when exchanging the PacDrive MC-4.
DANGER!
High Voltage!
Life Hazard!
High voltage possible wit h servo motors in generator operati on!
Before working on electrical units, disconnect from mains suppl y
and secure against switch-on.
Make sure that the drives are standing still .
Do not disconnect connector plugs while they are carrying voltage.
Before working on the unit, discharge the D C -circuit and use a
voltmeter to check that there is no voltage.
Maintenance
CAUTION!
Electro static discharge!
Components may be dama ged!
Only touch the boards on the edges. Do not touch any connections
or components.
Existing static charges can be discharged by touching a grounded
metallic surface, e.g. a grounded equipment casin g.
Prevent the development of electrostat ic charge by using suitable
clothing, carpets or fu rniture and by moving t he boards as little as
possible.
Exchange PacDrive MC-4
lift the main switch
secure against switch-on
DANGER!
Dangerous elect ri cal voltages also after the separa ti on from the network!
Life hazard!
Wait at least two minutes after the separation from the network,
until the inserted condensers are unloaded.
Check whether the v oltages sank after the two minutes to a harmless value.
Performance plug connectors of the cables only in status without
PDM_OpMaMC-4_05_us.FM
tension of the system separate or join!
ELAU AGPacDrive MC-4page 25
Page 26
Maintenance
CAUTION!
Hot surfaces on the PacDrive MC-4 and the brake modules (BM-4)!
Burn danger!
Wait for the MotorC ontroller or the brake modules to cool down
by istself or use the protective gloves.
Separate the access lines of the PacDrive MC-4.
Screws at upper housing and lower surface loosened.
Remove PacDrive MC-4.
Insert new PacDrive MC-4 and tighten the screws.
Attach the new PacDrive MC-4 according to the machine con-
nection diagram.
System in operation set again.
Korrekturausdruck
Exchange motor
lift the main switch
secure against switch-on
DANGER!
High voltage!
Life hazard!
Performance plug connectors of the cables only in st atus without
tension ot the system separate or join!
CAUTION!
Mechanical force!
Damage of the encoder system is possible!
When removing and applying clutches on the motor shaft no
impact may be executed on the mot or shaft, since otherwise the
encoder will be damaged. Use suitable tools e. g. pull ers.
page 26 PacDrive MC-4ELAU AG
PDM_OpMaMC-4_05_us.FM
Page 27
Korrekturausdruck
Maintenance
WARNING!
Inadvertent on movements!
Danger of accident!
With servo axles with indirect dist ance measurement system
over the motor encoder the measure reference is lost with
exchange of the engine!
The measure reference to the machine coordinate system is to
be reconstituted therefore after the exchange again!
While exchange of a motor the specification of the machine
manufacturer is to be considered.
During indirect entry of the position actual values over the motor-
own measuring system the measure reference must again be
reconstituted.
Exchange cable
lift the main s w itc h
secure against switch-on
DANGER!
High voltage!
Life hazard!
Seperate or join the plug connectors of th e cables only in status
without power on the system!
Performance plug connectors only with dry and clean putting
pages join!
If no finished manufactured cabl es are used by ELAU, allocat ion
of new cables for agreement with the connection di agram of the
machine manufacturer to check!
During the exchange of cables the specification of the machine
manufacturer is to be considered.
5.5 Cleani ng
With suitable installation the devices are to a large extend maintenance-free.
Dust and foreign bodies, which are near-carri ed particularly by the
cooling air flow, can be removed, as the devices are removed after
the unstressed switching and with dry compressed air (max. 1 bar)
are blown out.
PDM_OpMaMC-4_05_us.FM
ELAU AGPacDrive MC-4page 27
Page 28
Maintenance
5.6 EMC Rules
To control and regulate motors, the mains voltage is stored in the
DC-circuit of the servo drives by means of rect ification. This stored
energy is fed to the motor by deliberately switching on and off six
semiconductor switches. The steep rise and fall of the voltage puts
high demands on the insulation strength of the motor winding.
Another essential aspect to be considered is the Electro Magnetic
Compatibility (EMC) with other syst em co mpo nents. The flank
steepness of the clocked voltage gener ates harmonic oscill ations of
great intensity, up into the high-frequency range.
Therefore observe the following EMC rules:
Choose the earthing option with the lowest possible ohm rate
(e.g. unpainted mounting boar d of the switching cabinet) for
installation.
Contact the largest possible surface (skin effect). If necessary,
remove existing paint to achi eve large-surface contact.
From the Central Earthing Point (CEP), lay earthing wires to the
respective connections in a star structure. Earthing circuits are
not admissible and can cause unnecessary distortions.
Use shielded cables only.
Only large-surface shield transitions are admissible.
Shields must not be contacted via pin contacts of connector
plugs.
By all means observe the switching proposals.
Cut motor cables to minimum length.
Do not lay cable circuits inside the switching cabinet.
Korrekturausdruck
CAUTION!
Electromagnetic fields!
Disturbances or failure of the syste m poss ibl e!
With the installation following rules must be considered, in order to
exclude consequences of excessive disturbance effects as far as
possible.
page 28 PacDrive MC-4ELAU AG
PDM_OpMaMC-4_05_us.FM
Page 29
Korrekturausdruck
Maintenance
In connection with electronic controls, no inductive loads what-
soever must be switched without suitable interference elimination.
For DC operation, suitable interference elimination can be
achieved by arranging recovery diodes. For AC operation, commercially available erasing elements matching the connector
type can be used.
Only the interference elimination element mounted immediately
at the point of inductivity serves this purpose. In any other case,
the switching pulse may even emi t increased inter ference via the
interference elimination elements. It is much easier to avoid
sources of interference in the first place, than to eliminate the
effects of existing interference.
In no case must the contacts switching unshielded inductive
loads be arranged in the same room as the PacDrive MC-4; the
same goes for cables carrying unshielded, switched inducti vity
and cables running parallel to them. The control must be separated from such „disorders“ by a Faraday cage (own section i n
the switching cabinet).
CAUTION!
Electromagnetic fields!
Disturbances or failure of the system possible!
Depend on the combination servo drive / motor and the cable
length are to be used possibly system filters or motor filters.
Consider for this the projecting manual for the PacDrive™
system.
PDM_OpMaMC-4_05_us.FM
ELAU AGPacDrive MC-4page 29
Page 30
Maintenance
5.7 Commissioning
We recommend to take up first with ELAU commissioni ng
personnel.
This is not only occur for guarantee reasons, but also
the equipment check,
which determines optimal configuration,
the service personnel is instructed at the same time.
Commissioning procedure:
CAUTION!
The PacDrive units (MC-4, MAx-4, etc.) may be damaged by
inexpert installati on work!
Possible material damage!
Every person working on the plant / machine / switching cabinet in
which PacDrive components are installed must make sure that no
objects (e.g. chips, screws, etc.) fall into the ventilation slots of the
equipment (in particular, watch the top side!).
Finish all installation work such as drilling, screwing etc. before
you start mounting the unit s.
If installation work is necessary after the PacDrive units have
been mounted, by all means cover the units with due care
(IP20).
Korrekturausdruck
Unpacking
and
checking
Remove packaging.
Make sure the units are not damaged. Only undamaged units
should be put into operation.
Check if the consignment is complete.
Check if the optional slots are occupied correctly.
Check the data with the help of the type plate.
See also chapter „T ransportation, Storage, Unpacking“.
Installation Observe the requirements for the place in which the equipment
may be used.
Observe the requirements for protection and EMC rules.
Mount devices.
See also chapter „Maintenance“.
DANGER!
High leak current!
Life hazard!
The leak current is greater than 3.5 mA. Therefore the units
must have a firm connection to the power grid (a ccor ding to DIN
EN 50178 - equipment of high-voltage systems).
PDM_OpMaMC-4_05_us.FM
page 30 PacDrive MC-4ELAU AG
Page 31
Maintenance
Korrekturausdruck
Electrical
installation
Connecting
the control
voltage
Checking the
(24V)
safety
functions
Connecting
the mains
voltage
Connect the units, starting with the ground conductor.
Make sure the clamps are tight and the required cable cross
sections are correct.
Make sure the shield is executed correctly, rule out short -circuits
and interruptions.
See also chapter „Technical Data“and „Maint enance“
Check mains and control voltage.
Connect external 24 V control voltage.
9 The units initialize themselves and the LEDs should show the
following state:
– MAx-4: pow: ON, err: ON, buserr: ON, wd: OFF
– MC-4: pow: ON, err: flashing, buserr: ON
See also chapter „Technical Data“
Check thermo contact of the motor or PTC (see operating manu-
als for the connected components).
Check the functions of the brake (if any).
Check EMERGENCY OFF chain and EMERGENCY OFF switch.
Activate EMERGENCY OFF switch.
Connect mains voltage.
Check if the state indicator works correctly.
Deactivate EMERGENCY OFF switch.
Moving the
axis
Configura-
tion and pro-
gram
transmission.
When you move the axis for the first time, use a reliable small
user program in order to check:
– the correct turning direction of the axis
– the correct setting of the limit switches
– the brake path in both directions.
NOTE
When the 24V control voltage is connected, the servo amplifier MC-4
automatically detects the motor an d corresponding motor data.
Transmit the project to the PacDrive Controller with the Automa-
tion Toolkit EPAS-4.
PDM_OpMaMC-4_05_us.FM
ELAU AGPacDrive MC-4page 31
Page 32
Maintenance
DANGER!
Potentially dangerous movements!
Life hazard, risk of serious injury or material damage!
Make sure that there are no persons in the danger zone.
Remove from the motion range all tools, loose parts and other
auxiliaries that do not form part o f the axis/m achine/plant. (Make
sure the plant is ready for operation)
ELAU recommends not to couple the working machine until the
function test has been completed successfully!
Testing the
functionality
Check units and cabling again.
If it has not been done already, connect the mains voltage
Run function check by means of a check list for axis/machine/
plant functions.
Further com-
missioning
of the plant
Continue to commission the plant according to the operating
manual of the machine producer.
5.8 Configuration / Progr amming
The adjustment of the PacDrive™ system to their function takes
place with the automation toolkit EPAS-4.
In EPAS-4 the system is configured and programmed after IEC
61131-3.
NOTE
For further details on diagnosis, please consult the online help of
the Automation Toolkit EPAS-4.
Korrekturausdruck
CAUTION!
Complex functionality of the PacDrive™ system and the machine!
Damage possible!
Program modifications may be executed only by trained person-
nel with detailed knowledge of the syst em. Modificat ions may be
made therefore only by your machine supplier or by ELAU
coworkers. The ELAU AG is not responsibl e for damage by arbitrary program modifications.
page 32 PacDrive MC-4ELAU AG
PDM_OpMaMC-4_05_us.FM
Page 33
Korrekturausdruck
5.8.1 LEDs
5
6
4
3
2
1
0
5
6
4
3
2
1
0
reset
pow
err
7
8
9
S1
7
8
9
S2
buserr
Maintenance
Reset button
voltage display
error display
adress preselectionl
for real-time bus
S1 tens digit
S2 units digit
real-time bus
error display
pow
pow
err
PDM_Diagnose_MC-4_LED_us9912.fh8
Fig. 5-1: Diagnosis LEDs of the PacDrive MC-4
pow (control voltage display)
The LED „pow“ signals the condition of the control voltage.
OFFcontrol voltage (24 V) missing or too low.
ONnormal operation; control voltage in normal range
err (error indicator)
The Error-LED (err) is used for the error display. The following index
shows possible display states with the associated error report.
OFFnor mal operation
Flashing slowly (1 Hz)general error
Flashing fast (2 Hz)
SERCOS error
ONserious system error
bus err (SERCOS bus error display)
buserr
OFFnor mal operation
ONbus error (fiber-optic connecti on problem, e. g. trans-
mitting power too low or too high, cable break, ...)
PDM_OpMaMC-4_05_us.FM
ELAU AGPacDrive MC-4page 33
Page 34
Maintenance
S1
S2
S3
S1 / S2 SERCOS address switches
Use the rotary type switches S1 and S2 to set the SERCOS
address (0-99) of the servo amplifier MC-4. The tens digit is set
with switch S1. The singles digit is set with switch S2.
S3 fiber-optic intensity
The sender intensity of the fiber-optic light source is set on the
PacDrive MC-4 with the DIL switches S3 on the front side. The sende r
intensity depends on the length of the cable up to the next slave.
cable length [meter]intensity
0.1 - 1 1
1.1 - 202
20.1 - 403
40.1 - 504
Table 5-1: Fiber-optic intensity with dedicated cable length
.
Korrekturausdruck
Intensity: 1
Fig. 5-2: Positioning switch on the front panel of the PacDrive MC-4
Intensity: 2Intensity: 3Intensity: 4
reset
Button to reset the servo ampl ifier MC-4 . Only t he servo amplif ier is
reset
rebooted if you activate the „reset“ button. Other Pa cDrive Controllers MAx-4, C200 etc. that may be connected have thei r own „reset“
buttons.
5.8.2 Example of a diagnosis message
The diagnosis message 121 „Bleeder temperature too high“ is
shown.
Meaning of the diagnosis message:
Class 2 error
Diagnosis code 121
The meaning of the diagnosis code is further expl ained in the online
help of the Automation Toolkits EPAS-4.
PDM_LWLintens_MC-4_us.fh8
121 Bleeder temperature too high
The bleeder is overloaded.
CauseThe drive is dimensioned incorrectly.
SolutionCheck drive dimensioning.
CauseHardware error: Bleeder or control is defective.
SolutionContact our customer service.
page 34 PacDrive MC-4ELAU AG
PDM_OpMaMC-4_05_us.FM
Page 35
Korrekturausdruck
Maintenance
5.9 Order Num bers
5.9.1 PacDrive MC-4
Type keyMC-4 / 11 / 10 / 400
HW-Identifier
11
Rated current
e.g. 03 = 3 A
Rated voltage
230 = 230 V
400 = 400 V (3 external ducts)
Order numberProduct nameExplanation
13 13 02 44MC-4 / 11 / 01 / 400MC-4 1.5 A 400 V
13 13 02 45MC-4 / 11 / 03 / 400MC-4 3 A 400 V
13 13 02 46MC-4 / 11 / 05 / 230MC-4 5 A 230 V
13 13 02 47MC-4 / 11 / 10 / 400MC-4 10 A 400 V
13 13 02 54MC-4 / 11 / 22 / 400MC-4 22 A 400 V
13 13 02 56MC-4 / 11 / 50 / 400MC-4 50 A 400 V
Table 5-2: Order numbers and variants for MC-4
PDM_OpMaMC-4_05_us.FM
ELAU AGPacDrive MC-4page 35
Page 36
Maintenance
5.9.2 Cable
Motor cables
Order numberProduct nameExplanations
15 15 41 01E-MO-067 UL cable 1,5 mm
15 15 41 21E-MO-092 UL cable 1,5 mm
15 15 41 12E-MO-082 UL cable 2,5 mm
15 15 41 17E-MO-087 UL cable 2,5 mm
15 15 41 20E-MO-091 UL cable 4 mm
15 15 41 02E-MO-068 CE cable 1,5 mm
15 15 41 07E-MO-073 CE cable 1,5 mm
15 15 41 03E-MO-069 CE cable 2,5 mm
15 15 41 11E-MO-081SB 205 with plug
15 15 41 13E-MO-083 CE cable 2,5 mm
15 15 41 14E-MO-084 CE cable 4 mm
15 15 41 15-XXXE-MO-085 SM 1.5on MC-4 X4
15 15 41 16-XXXE-MO-086 SM 1.5SR-058 on
15 15 41 19E-MO-090 SB-205 with
15 15 41 27 - XXX E - MO - 111 Kabel 2.5 mm
15 15 41 28 - XXX E - MO - 112 Kabel 2.5 mm
15 15 41 29 - XXX E - MO - 113 Kabel 2.5 mm
2
SM-070/100
on MC-4 X4
2
SM-140
on MC-4 X4
2
SM-140/30/210/..
with fan
on MC-4 / 22 A X4
2
SM-140/30/290;
SM-140/30/370
on MC-4 / 22 A X4
2
SM-140/30/370/...
with fan
on MC-4 / 22 A X4
on MC-4 / 50 A X4
2
SM-070/100
Korrekturausdruck
on MC-4 X4
2
SM-140
on MC-4 X4
2
SM-140/30/210/...
with fan
on MC-4 / 22 A X4
2
2,5 mm
on MC-4 X4
2
SM-140/30/290;
SM-140/30/370
on MC-4 / 22 A X4
2
(SM-140/30/370/...
with fan)
on MC-4 / 22 A X4
on MC-4 / 50 A X4
CE cable
MC-4 X4 UL cable
connection box
2
10 mm
on MC-4 / 50 A X4
2
SH055, 070, 100
and SH140/30/120,
/200 plug small,
short
2
SH055, 070, 100
and SH140/30/120,
/200 plug small,
long
The PacDrive MC-4 supports motors with firmware up to
V00.20.XX with a rotary speed up to 6000 min
On firmware versions V00.22.XX, the rated speed is supported up
to 12000 min
In case of ambient temperatures >45 °C, f or addit ional excha nge of
cooling air provide external fan in the switching cabinet.
NOTE
The PacDrive MC-4 is not suitable for fault current protection with a
common FI safety switch with a trigger level of 30 mA. The leakage
current of the unit can trigger the FI safety switch. Solutions fo this
problem:
Use an FI safety switch (RCD, type B) with a trigger level of 500 mA.
NOTE
The PacDrive MC-4 / 1,5 A is adequate only when using
versions as from V00.22.XX,
Is a motor used with a differing power class, the error message
„138 invalid motor“ will appear.
-1
.
in connection with the SH Motor 055.
-1
.
firmware
PDM_OpMaMC-4_06_us.FM
ELAU AGPacDrive MC-4page 39
Page 40
Technical Data
6.1.1 In General
PacDrive MC-4 / 1.5A
ParameterValue
Product
configuration
Product nameMC-4 / 11 / 01 / 400 V
Order numb er13 13 02 44
Power supply- rated connection voltage
- mains frequency
- control voltage/current
DC-circuit- DC-circuit voltage
- capacity
- U
Bleeder
- U
Bleeder
- excess voltage
- bleeder resistance
- bleeder - permanent power
- bleeder - peak power
Motor
connection
Stray power- electronics supply
I/OInputs
- rated power 8 kHz
- peak current 1 s
- rated power
- bleeder (internal)
- power part
- inputs voltage / current
- ie-input
- input filter
Outputs
- relay outputsDC 20 ... 30 V / 2 A
ON
OFF
3 AC 380 V (-10%) to 480 V (+10%)
- min. 3 AC 380 V (-10%)
- max. 3 AC 480 V (+10%)
48 ... 62 Hz
DC 24 V (-15% / +25%) / 1 A
DC 530 V to 680 V
165 µF
DC 820 V
DC 800 V
DC 860 V
120 Ohm
50 W
5 kW
1.5 Aeff
3.75 Aeff
1.1 kVA
approx. 12 W
0 ... 50 W (depending on the application)
approx. 15 W / A
DC 20 ... 30 V / 5 mA
DC 20 ... 30 V / 30 mA
[5 ms
Korrekturausdruck
EnvironmentProduct size
Box size
Product weight
Boxed weight
Ventilationnatural convection
Ambient conditions
Protection class
- casing
- installation location
- ambient temperature during
operation
- for storage and transport
-insulation
- excess voltage category
- excess voltage proofness
- degree of radio distortion
rel. humidity
ApprovalApprovalsCE, UL, cUL
Table 6-1: Technical data of the PacDrive MC-4 / 01
see chapter Dimensions
width: 100 mm
height: 400 mm
depth: 320 mm
3.1 kg
4.0 kg
IP20
IP54, if the safety wiring is used with
Inverter Enable
+5 ... +45 °C (+55 °C with reduced power)
-2% per K at INC and ISC)
-25 ... +70 °C
degree of pollution 2 ..., dewing prohibited
K III, T2 (DIN VDE 0110)
class 1 (DIN VDE 0160)
class A EN 55011 / EN 61800 - 3
5% - 85% climatic category 3K3 EN 60 721
PDM_OpMaMC-4_06_us.FM
page 40PacDrive MC-4ELAU AG
Page 41
Product
configuration
Technical Data
PacDrive MC-4 / 3 A
ParameterValue
Product nameMC-4 / 11 / 03 / 400 V
Order number13 13 02 45
Korrekturausdruck
Power supply- rated connection voltage
- mains frequency
- control voltage/current
DC-circuit- DC-circuit voltage
- capacity
Bleeder
Bleeder
ON
OFF
- U
- U
- excess voltage
- bleeder resistance
- bleeder - permanent power
- bleeder - peak power
Motor
connection
Stray power- electronics supply
I/OInputs
- rated power 8 kHz
- peak current 1 s
- rated power
- bleeder (internal)
- power part
- inputs voltage / current
- ie-input
- input filter
Outputs
- relay outputsDC 20 ... 30 V / 2 A
3 AC 380 V (-10%) to 480 V (+10%)
- min. 3 AC 380 V (-10%)
- max. 3 AC 480 V (+10%)
48 ... 62 Hz
DC 24 V (-15% / +25%) / 1 A
DC 530 V to 680 V
165 µF
DC 820 V
DC 800 V
DC 860 V
120 Ohm
50 W
5 kW
3 Aeff
7.5 Aeff
2.1 kVA
ca. 12 W
0 ... 50 W (depending on the application)
ca. 15 W / A
DC 20 ... 30 V / 5 mA
DC 20 ... 30 V / 30 mA
[5 ms
EnvironmentProduct size
Box size
Product weight
Boxed weight
Ventilationnatural convection
Ambient conditions
Protection class
- casing
- installation location
- ambient temperature during
operation
- for storage and transport
-insulation
- excess voltage category
- excess voltage proofness
- degree of radio distortion
rel. humidity
ApprovalApprovalsCE, UL, cUL
Table 6-2: Technical data of the PacDrive MC-4 / 03
PDM_OpMaMC-4_06_us.FM
see chapter Dimensions
width: 100 mm
height: 400 mm
depth: 320 mm
3.1 kg
4.0 kg
IP20
IP54, if the safety wiring is used with Inverter
Enable
+5 ... +45 °C (+55 °C with reduced power)
-2% per K at INC and ISC)
-25 ... +70 °C
degree of pollution 2 ..., dewing prohibited
K III, T2 (DIN VDE 0110)
class 1 (DIN VDE 0160)
class A EN 55011 / EN 61800 - 3
5% - 85% climatic category 3K3 EN 60 721
ELAU AGPacDrive MC-4page 41
Page 42
Technical Data
PacDrive MC-4 / 5 A
CAUTION!
Unit has different rated connection voltage! Wrong connection voltage
may destroy the MotorController! During wiring and installation, make
sure that the connection voltage matches the MotorController
ParameterValue
Product
configuration
Power supply- rated connection voltage
DC-circuit- DC-circuit voltage
Motor
connection
Stray power- electronics supply
I/OInputs
EnvironmentProduct size
Product nameMC-4 / 11 / 05 / 230 V
Order numb er13 13 02 46
- mains frequency
- control voltage/current
- capacity
- U
Bleeder
- U
Bleeder
- excess voltage
- bleeder resistance
- bleeder - permanent power
- bleeder - peak power
- rated power 8 kHz
- peak current 1 s
- rated power
- bleeder (internal)
- power part
- inputs voltage / current
- ie-input
- input filter
Outputs
- relay outputsDC 20 ... 30 V / 2 A
Box size
Product weight
Boxed weight
Ventilationnatural convection
Ambient conditions
Protection class
- casing
- installation location
- ambient temperature during
operation
- for storage and transport
-insulation
ON
OFF
.
3 AC / 1 AC 220 V (-10%) to 240 V (+10%)
48 ... 62 Hz
DC 24 V (-15% / +25%) / 1 A
DC 260 V to 370 V
660 µF
DC 410 V
DC 400 V
DC 430 V
33 Ohm
50 W
5 kW
5 Aeff
12.5 Aeff
1.9 kVA
ca. 12 W
0 ... 50 W (depending on the application)
ca. 15 W / A
DC 20 ... 30 V / 5 mA
DC 20 ... 30 V / 30 mA
[5 ms
see chapter Dimensions
width: 100 mm
height: 400 mm
depth: 320 mm
3.1 kg
4.0 kg
IP20
IP54, if the safety wiring is used with Inverter
Enable
+5 ... +45 °C (+55 °C with reduced power)
-2% per K at INC and ISC)
-25 ... +70 °C
degree of pollution 2 ..., dewing prohibited
Korrekturausdruck
- excess voltage category
- excess voltage proofness
- degree of radio distortion
rel. humidity
ApprovalApprovalsCE, UL, cUL
Table 6-3: Technical data of the PacDrive MC-4 / 05
page 42PacDrive MC-4ELAU AG
K III, T2 (DIN VDE 0110)
class 1 (DIN VDE 0160)
class A EN 55011 / EN 61800 - 3
5% - 85% climatic category 3K3 EN 60 721
PDM_OpMaMC-4_06_us.FM
Page 43
Product
configuration
Technical Data
PacDrive MC-4 / 10 A
ParameterValue
Product nameMC-4 / 11 / 10 / 400 V
Order number13 13 02 47
Korrekturausdruck
Power supply- rated connection voltage
- mains frequency
- control voltage/current
DC-circuit- DC-circuit voltage
- capacity
- U
- U
- excess voltage
- bleeder resistance
- bleeder - permanent power
- bleeder - peak power
Motor
connection
Stray power- electronics supply
I/OInputs
- rated power 8 kHz
- peak current 1 s
- rated power
- bleeder (internal)
- power part
- inputs voltage / current
- ie-input
- input filter
Outputs
- relay outputsDC 20 ... 30 V / 2 A
Bleeder
Bleeder
ON
OFF
3 AC 380 V (-10%) to 480 V (+10%)
48 ... 62 Hz
DC 24 V (-15% / +25%) / 1 A
DC 530 V to 680 V
330 µF
DC 820 V
DC 800 V
DC 860 V
60 Ohm
100 W
10 kW
10 Aeff
25 Aeff
6.9 kVA
ca. 12 W
0 ... 100 W (depending on the application)
ca. 15 W / A
Table 6-6: Technical data of the PacDrive MC-4 / 50
PDM_OpMaMC-4_06_us.FM
see chapter Dimensions
width: 350 mm
height: 450 mm
depth: 310 mm
16.5 kg
19.0 kg
IP20
IP54, if the safety wiring is used with Inverter
Enable
+5 ... +45 °C (+55 °C with reduced power)
-2% per K at INC and ISC)
-25 ... +70 °C
degree of pollution 2 ..., dewing prohibited
K III, T2 (DIN VDE 0110)
class 1 (DIN VDE 0160)
class A EN 55011 / EN 61800 - 3 with
external mains filter
5% - 85% climatic category 3K3 EN 60 721
ELAU AGPacDrive MC-4page 45
Page 46
Technical Data
CAUTION!
Firmware version V00.11.XX or higher is required to operate the
PacDrive MC-4 / 50 A! Some functions (including safety-relevant
functions)
are not supported in firmware versions older than
V00.11.XX.
Only use the PacDrive MC-4 / 50A with firmware in original
condition.
If a firmware change is inevitable, only use versions higher than
V00.11.XX.
NOTE
The „ambient temperature during operation“ up to 45 °C is only
valid if the control voltage is at least DC 24 V, so that the fans can
work with the required power.
Korrekturausdruck
NOTE
To observe EMT requirements, it is necessary to use an external
mains filter (order number FI07878).
page 46PacDrive MC-4ELAU AG
PDM_OpMaMC-4_06_us.FM
Page 47
6.1.2 Interface
Technical Data
U
A
Korrekturausdruck
control voltage X1
mains connection X2
DC-circuit X3
motor connection X4
MC-4
PacDrive
24V/o
24V/i
X1
ac-power
X2
dc-bus
X3
ac-motor
X4
max.
torque
0,5Nm
C US
LISTED
(INDUSTRIAL
CONTROL
EQUIPMENT)
!
buserr
Made in Germany
72KL
Instructions see cover side!
reset
pow
err
S1
S2
X5
X6
S3
diag
X7
X5 LWL IN *)
SERCOS
X6 LWL OUT *)
X7 diagnosis
X8 encoder
feedback
X8
shield connection
PDM_Anschlussübersicht_MC-4_us9912.FH8
Fig. 6-1: Overview of connections of the PacDrive MC-4
PDM_OpMaMC-4_06_us.FM
ELAU AGPacDrive MC-4page 47
Page 48
Technical Data
6.1.3 Electrical Connections
X1 - control voltage (MC-4 1.5 A to 10 A)
1 9
8 16
Pin
Designation
MeaningRange
Max. cross
section
124 Vsupply voltage-15% / +25%1.5 mm
20 Vsupply voltage1.5 mm
3ieiinverter enable1.5 mm
4enenable
DC 24V (acc.
1.5 mm
IEC61131-2 Typ I)
5ϑ (5)PTC motor temp.1.5 mm
6ϑ (6)PTC motor temp.1.5 mm
7bi+power supply holding
DC +24V1.5 mm
brake
8bi-power supply holding
DC 0V1.5 mm
brake
924 Vbridged with Pin 1 1.5 mm
100 Vbridged with Pin 2 1.5 mm
11ieoinverter enable
1.5 mm
output
12ieoinverter enable
1.5 mm
output
13rdyready contact (opens
DC 20...30V / 2A1.5 mm
in case of error)
14rdyready contactDC 20...30V / 2A1.5 mm
15bo+ (8)connection holding
DC +24V1.5 mm
brake
16bo- (7)connection holding
0V1.5 mm
brake
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Korrekturausdruck
Table 6-7: Electrical connections of the MC-4 (1.5 ... 10 A) / X1
NOTE
The permissible permanent current of the plug-in terminal „X1
control voltage“ (MC-4 1.5 A to 10 A) is 8 A.
The maximum number of MCs connected parallel via the plg-in
terminal X 1 must be no greater than six.
X2 - mains connection (MC-4 1.5 A to 10 A)
PE
L1
L2
Pin
1PEearth conductor
2L1phase L13 AC 380 - 480 V2.5 mm
L3
3L2phase L23 AC 380 - 480 V2.5 mm
4L3phase L33 AC 380 - 480 V2.5 mm
Table 6-8: Electrical connections of the MC-4 (1.5 ... 10 A) / X2
Designation
MeaningRange
connection
Max.
cross
section
2.5 mm
2
2
2
2
PDM_OpMaMC-4_06_us.FM
page 48PacDrive MC-4ELAU AG
Page 49
Korrekturausdruck
Technical Data
NOTE
The permissible permanent current of the plug-in terminal „X2
mains connection“ (MC-4 1.5 A to 10 A) is 24 A.
NOTE
The range for the MC-4 / 5 A is 220 - 240 V with 3-phase or 1phase feed. With 1-phase feed, connect L to L1 and N to L2. Leave
L3 free.
CAUTION!
No safe contact!
Cables and clamps may be damaged!
For cables with a cross section of 2.5 mm
without plastic collar and a length of at least 12 mm or end
sleeves with plastic collar and a metal sleeve that is at least 12
mm long.
2
, use end sleeves
X3 - DC-circuit (MC-4 1.5 A to 10 A)
db+
db+
db-
db-
Pin
1db +DC-circuit voltage +DC 0 - 860 V2.5 mm
2db +DC-circuit voltage +DC 0 - 860 V2.5 mm
3db -DC-circuit voltage -DC 0 - 860 V2.5 mm
4db -DC-circuit voltage -DC 0 - 860 V2.5 mm
Table 6-9: Electrical connections of the MC-4 (1.5 ... 10 A) / X3
Desig-
nation
MeaningRange
Max.
cross
section
2
2
2
2
NOTE
The permissible permanent current of the plug-in terminal „X3
Dc-circuit“ (MC-4 1.5 A to 10 A) is 24 A.
CAUTION!
No safe contact!
Cables and clamps may be damaged!
For cables with a cross section of 2.5 mm
2
, use end sleeves
without plastic collar and a length of at least 12 mm or end
sleeves with plastic collar and a metal sleeve that is at least 12
PDM_OpMaMC-4_06_us.FM
mm long.
ELAU AGPacDrive MC-4page 49
Page 50
Technical Data
X4 - motor connection (MC-4 1.5 A to 10 A)
PE
W
Pin
1PEearth conductor
U
2Uphase U3 AC 0 - 480 V2.5 mm
V
3Vphase V3 AC 0 - 480 V2.5 mm
4Wphase W3 AC 0 - 480 V2.5 mm
Table 6-10: Electrical connections of the MC-4 (1.5 ... 10 A) / X4
Designation
MeaningRange
connection
NOTE
The permissible permanent current of the plug-in terminal „X4 motor
connection (MC-4 1.5 A to 10 A) is 24 A.
CAUTION!
No safe contact!
Cables and clamps may be damaged!
For cables with a cross section of 2.5 mm2, use end sleeves
without plastic collar and a length of at least 12 mm or end sleeves
with plastic collar and a metal sleeve that is at leas t 12 mm long.
Max. cross
section
2.5 mm
2
2
2
2
Korrekturausdruck
24V
24V
0V
0V
en
rdy+
rdyiei
ieo+
ieo-
J
J
bi+
bo+
bi-
X1
bo-
X1 - control voltage (MC-4 22 A, 50 A)
PinDesignationMeaningRange
124 Vsupply voltage-15% / +25%1.5 mm
224 Vbridged with pin 1 1.5 mm
30 Vsupply voltage1.5 mm
40 Vbridged with Pin 3 1.5 mm
5enenableDC 24V (acc.
IEC61131-2 Typ I)
6rdy+ready contactDC 20...30V / 2A1.5 mm
7rdy-ready contact
(opens in case of error)
8ieiinverter enable1.5 mm
9ieo+inverter enable
output
10ieo-inverter enable
output
11(5)PTC motor temp.1.5 mm
12(6)PTC motor temp.1.5 mm
13bi+power supply holding
brake
14bo+ (8)connection holding
brake
15bi-power supply holding
brake
16bo- (7)connection holding
brake
Table 6-11: Electrical connections of the MC-4 (22 A, 50 A) / X1
DC 20...30V / 2A1.5 mm
DC +24V1.5 mm
DC +24V1.5 mm
DC 0V1.5 mm
0V1.5 mm
Max. cross
section
1.5 mm
1.5 mm
1.5 mm
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
PDM_OpMaMC-4_06_us.FM
page 50PacDrive MC-4ELAU AG
Page 51
Technical Data
X2 - mains connection (MC-4 22 A)
Korrekturausdruck
PE
Pin
1PEearth conductor
L1
2L1phase L13 AC 380 - 480V4 mm
L2
3L2phase L23 AC 380 - 480V4 mm
4L3phase L33 AC 380 - 480V4 mm
L3
Desig-
nation
MeaningRange
connection
Table 6-12: Electrical connections of the MC-4 (22 A) / X2
X3 - DC-circuit (MC-4 22 A)
db+
db+
Pin
1db +DC-circuit voltage +DC 0 - 860 V4 mm
2db +DC-circuit voltage +DC 0 - 860 V4 mm
db-
3db -DC-circuit voltage -DC 0 - 860 V4 mm
4db -DC-circuit voltage - DC 0 - 860 V4 mm
db-
Table 6-13: Electrical connections of the MC-4 (22 A) / X3
Desig-
nation
MeaningRange
X4 - motor connection (MC-4 22 A)
PE
U
Pin
1PEearth conductor
2U (1)phase U3 AC 0 - 480V4 mm
V
3V (2)phase V3 AC 0 - 480V4 mm
4W (3)phase W3 AC 0 - 480V4 mm
W
Table 6-14: Electrical connections of the MC-4 (22 A) / X4
Desig-
nation
MeaningRange
connection
Max. cross
section
2
4 mm
2
2
2
Max. cros s
section
2
2
2
2
Max. cross
section
2
4 mm
2
2
2
X2 - mains connection (MC-4 50 A)
PEL1L2
Pin
L3
Desig-
nation
MeaningRange
1PEearth conductor
connection
2L1phase L13 AC 380 - 480V16 mm
3L2phase L23 AC 380 - 480V16 mm
4L3phase L33 AC 380 - 480V16 mm
Table 6-15: Electrical connections of the MC-4 (50 A) / X2
Max. cross
section
2
16 mm
2
2
2
X3 - DC-circuit (MC-4 50 A)
db+
db+
db-
db-
Pin
Designation
MeaningRange
1db +DC-circuit voltage +DC 0 - 860 V16 mm
2db +DC-circuit voltage +DC 0 - 860 V16 mm
3db -DC-circuit voltage -DC 0 - 860 V16 mm
PDM_OpMaMC-4_06_us.FM
4db -DC-circuit voltage - DC 0 - 860 V16 mm
Table 6-16: Electrical connections of the MC-4 (50 A) / X3
ELAU AGPacDrive MC-4page 51
Max. cross
section
2
2
2
2
Page 52
Technical Data
X4 - motor connection (MC-4 50 A)
PE
W
V
Pin
U
Designation
MeaningRange
1PEearth conductor
Max. cross
section
2
16 mm
connection
2W (3)phase W3 AC 0 - 480V16 mm
3V (2)phase V3 AC 0 - 480V16 mm
4U (1)phase U3 AC 0 - 480V16 mm
2
2
2
Table 6-17: Electrical connections of the MC-4 (50 A) / X4
X7 - diagnosis
Pin
Designation
MeaningRange
1PRO_SEL0.25 mm
2RxDReceive Data0.25 mm
3TxDTransmit Data0.25 mm
4GNDSignal Ground0.25 mm
5RS232_SEL0.25 mm
6VCC0.25 mm
Max. cross
section
2
2
2
2
2
2
Korrekturausdruck
Table 6-18: Electrical connections of the MC-4 / X7
X8 - motor encoder (SinCos)
Pin
Designation
MeaningRange
1REFSINsinus reference
signal
2SINsinus trace0.2 5 mm
3REFCOScosine refe rence
signal
4COScosine trace0.25 mm
5+12Vsupply voltage0.25 mm
6RS485parameter channel -0.25 mm
7RS485parameter channel +0.25 mm
8SC_SELencoder connected
(bridge to GND)
9GNDsupply voltage0.25 mm
Table 6-19: Electrical connections of the MC-4 / X8
Max. cross
section
0.25 mm
0.25 mm
0.25 mm
2
2
2
2
2
2
2
2
2
page 52PacDrive MC-4ELAU AG
PDM_OpMaMC-4_06_us.FM
Page 53
CAUTION!
Disconnection of SinCos encoder plug while unit is powered on!
SinCos encoder may be damaged!
Disconnect and connect the SinCos encoder plug only in
voltage-free state (di sconnect PacDrive MC-4 from 24 V power
supply!).
6.1.4 Dimension s
PacDrive MC-4 / 1.5 A and 3 A
Technical Data
Korrekturausdruck
!
ACHTUNG! ATTENTION!
HOCHSPANNUNG!
Vor Arbeiten am Gerät, Netzanschluß trennen. Entladezeit > 2min.
ERHÖHTER ABLEITSTROM!
Betrieb nur mit angeschlossenem Schutzleiter.
HOHE TEMPERATUR!
Oberfläche des Gerätes im Betriebszustand nicht berühren.
INSTALLATION!
Bei Inbetriebnahme, Installationshinweise in der Bedienungsanleitung beachten.
HIGH VOLTAGE! Disconnect from mains supply, before working on this equipment, Electric discharge> 2min.
Operation only with connected safety ground.
HIGH LEAKAGE CURRENT!
HIGH TEMPERATURE!
Do not touch this surface under operation conditions.
INSTALLATION!
Read installation instruction before installing.
HAUTE TENSION!
Coupez l´alimentation avant de manipuler l´appareil. Temps de décharge > 2min.
COURANT DE FUITE ELEVEE! Fonctionnement uniquement avec conducteur de protection raccordé.
TEMPERATURE ELEVEE!
ne touchez pas la surface de l´appareil en marche.
INSTALLATION!
Respectez le manuel d´instruction lors de la mise en marche.
ALTA TENSIONE!
Disconetttere l`alimentazione prima di lavorare all`apparecchio. Tempo di scarica > 2min.
ALTA DISPERSIONE DI CORRENTE! Operare solo con il conduttore di scarico a terra collegato.
ALTA TEMPERATURA!
Non toccare la superficie dell`apparecchio in funcione.
INSTALLATIONE!
Prima della messa in funzione dell`apparecchio consultare il manuale di istruzione
ALTO VOLTAJE!
Desconecten de la red antes de trabajar con este equipo, descarga electrica > 2min.
ALTA TENSION!
Operen solo con una conexion a tierra segura.
ALTA TEMPERATURA!
No toquen esta superficie durante la operacion.
INSTALACION!
Lean las instrucciones de montaje antes de instalar.
230 (9.06)
260 max. dimensions
65 (2.56)
7.0
25.5
296 (11.7)
240 (9.45)
44.5 (1.75)
7.0 (0.28)
34.5 (1.36)34.5
Ø6.5
(0.26)
(1.00)
310 (12.2)
MC4_1.5 A_Ansicht_englisch.FH8
PacDrive
24V/o
24V/i
X1
ac-power
X2
dc-bus
X3
ac-motor
X4
MC-4
Made in Germany
60 (2.36)
69 (2.72)
U
A
C US
LISTED
(INDUSTRIAL
CONTROL
EQUIPMENT)
72KL
!
Instructions see cover side!
reset
pow
err
S1
S2
buserr
X5
X6
S3
diag
X7
feedback
X8
Fig. 6-2: Dimensions of the PacDrive MC-4 / 1.5 A and 3 A
PDM_OpMaMC-4_06_us.FM
ELAU AGPacDrive MC-4page 53
Page 54
Technical Data
PacDrive MC-4 / 5 A (230 V)
!
ACHTUNG! ATTENTION!
HOCHSPANNUNG!
Vor Arbeiten am Gerät, Netzanschluß trennen. Entladezeit > 2min.
ERHÖHTER ABLEITSTROM!
Betrieb nur mit angeschlossenem Schutzleiter.
HOHE TEMPERATUR!
Oberfläche des Gerätes im Betriebszustand nicht berühren.
INSTALLATION!
Bei Inbetriebnahme, Installationshinweise in der Bedienungsanleitung beachten.
HIGH VOLTAGE! Disconnect from mains supply, before working on this equipment, Electric discharge> 2min.
Operation only with connected safety ground.
HIGH LEAKAGE CURRENT!
HIGH TEMPERATURE!
Do not touch this surface under operation conditions.
INSTALLATION!
Read installation instruction before installing.
HAUTE TENSION!
Coupez l´alimentation avant de manipuler l´appareil. Temps de décharge > 2min.
COURANT DE FUITE ELEVEE! Fonctionnement uniquement avec conducteur de protection raccordé.
TEMPERATURE ELEVEE!
ne touchez pas la surface de l´appareil en marche.
INSTALLATION!
Respectez le manuel d´instruction lors de la mise en marche.
ALTA TENSIONE!
Disconetttere l`alimentazione prima di lavorare all`apparecchio. Tempo di scarica > 2min.
ALTA DISPERSIONE DI CORRENTE!
Operare solo con il conduttore di scarico a terra collegato.
ALTA TEMPERATURA!
Non toccare la superficie dell`apparecchio in funcione.
INSTALLATIONE!
Prima della messa in funzione dell`apparecchio consultare il manuale di istruzione
ALTO VOLTAJE!
Desconecten de la red antes de trabajar con este equipo, descarga electrica > 2min.
ALTA TENSION!
Operen solo con una conexion a tierra segura.
ALTA TEMPERATURA!
No toquen esta superficie durante la operacion.
INSTALACION!
Lean las instrucciones de montaje antes de instalar.
230 (9.06)
260 (10.2) max. dimensions
65 (2.56)
7.0
25.5
(1.00)
296 (11.7)
240 (9.45)
44.5 (1.75)
7.0 (0.28)
34.5 (1.36)34.5
Ø6.5
(0.26)
PacDrive
24V/i
24V/o
X1
230 VOLT
310 (12.2)
ac-power
X2
dc-bus
X3
ac-motor
X4
MC4_5A_Ansicht_englisch.FH8
MC-4
Made in Germany
60 (2.36)
69 (2.72)
U
A
C US
LISTED
(INDUSTRIAL
CONTROL
EQUIPMENT)
72KL
!
Instructions see cover side!
reset
pow
err
S1
S2
buserr
X5
X6
S3
diag
X7
feedback
X8
Korrekturausdruck
Fig. 6-3: Dimensions of the PacDrive MC-4 / 5 A
page 54PacDrive MC-4ELAU AG
PDM_OpMaMC-4_06_us.FM
Page 55
Korrekturausdruck
PacDrive MC-4 / 10 A
!
ACHTUNG! ATTENTION!
HOCHSPANNUNG!
Vor Arbeiten am Gerät, Netzanschluß trennen. Entladezeit > 2min.
ERHÖHTER ABLEITSTROM!
Betrieb nur mit angeschlossenem Schutzleiter.
HOHE TEMPERATUR!
Oberfläche des Gerätes im Betriebszustand nicht berühren.
INSTALLATION!
Bei Inbetriebnahme, Installationshinweise in der Bedienungsanleitung beachten.
HIGH VOLTAGE! Disconnect from mains supply, before working on this equipment, Electric discharge> 2min.
HIGH LEAKAGE CURRENT!
Operation only with connected safety ground.
HIGH TEMPERATURE!
Do not touch this surface under operation conditions.
INSTALLATION!
Read installation instruction before installing.
HAUTE TENSION!
Coupez l´alimentation avant de manipuler l´appareil. Temps de décharge > 2min.
COURANT DE FUITE ELEVEE!
Fonctionnement uniquement avec conducteur de protection raccordé.
TEMPERATURE ELEVEE!
ne touchez pas la surface de l´appareil en marche.
INSTALLATION!
Respectez le manuel d´instruction lors de la mise en marche.
ALTA TENSIONE!
Disconetttere l`alimentazione prima di lavorare all`apparecchio. Tempo di scarica > 2min.
ALTA DISPERSIONE DI CORRENTE!
Operare solo con il conduttore di scarico a terra collegato.
ALTA TEMPERATURA!
Non toccare la superficie dell`apparecchio in funcione.
INSTALLATIONE!
Prima della messa in funzione dell`apparecchio consultare il manuale di istruzione
ALTO VOLTAJE!
Desconecten de la red antes de trabajar con este equipo, descarga electrica > 2min.
ALTA TENSION!
Operen solo con una conexion a tierra segura.
ALTA TEMPERATURA!
No toquen esta superficie durante la operacion.
INSTALACION!
Lean las instrucciones de montaje antes de instalar.
Technical Data
7.0(0.28)
25.5
(1.00)
296 (11.7)
240 (9.45)
310 (12.2)
Ø6.5
(0.26)
34.5 (1.36)
MC-4
PacDrive
24V/o
24V/i
X1
ac-power
X2
dc-bus
X3
34.5 (1.36)
U
A
C US
LISTED
(INDUSTRIAL
CONTROL
EQUIPMENT)
72KL
!
Instructions see cover side!
reset
pow
err
S1
S2
buserr
X5
X6
S3
diag
X7
230 (9.06)
70 (2.76)
260 (10.2) max. dimensions
Fig. 6-4: Dimensions of the PacDrive MC-4 / 10 A
7.0(0.28)
44.5(1.75)
ac-motor
X4
Made in Germany
60 (2.36)
69 (2.72)
MC4_10A_Ansicht_englisch.FH8
X8
feedback
PDM_OpMaMC-4_06_us.FM
ELAU AGPacDrive MC-4page 55
Page 56
Technical Data
PacDrive MC-4 / 22 A
2770 (2.76)
27 (1.06)
Ø6.5
(0.26)
7.0(0.28)
(1.00)
25.5
US
CONTROL
LISTED
(INDUSTRIAL
C
MC-4
72KL
EQUIPMENT)
!
PEL1L2
PacDrive
err
S2
S1
pow
reset
buserr
Hinweise siehe Seitenwand!
Instructions see cover side!
24V
24V0V0V
en
rdy+
rdy-
L3
db+
ac-power
X2
310 (12.2)
240 (9.45)
296 (11.7)
X7
PEUV
feedback
X8
WARNING: High voltage!
ACHTUNG: Hochspannung!
W
ac-motor
X4
Made in Germany
124 (4.88)
MC4_22A_Ansicht_englisch.FH8
X5
iei
ieo+
db+
diag
X6
S3
24V i/o
X1
bi+
bo+
bi-
bo-
J
J
ieo-
db-
db-
dc-bus
X3
44.5(1.75)
7.0(0.28)
Korrekturausdruck
133 (5.24)
Fig. 6-5: Dimensions of the MC-4 / 22 A
230 (9.06)
260 (10.2) max. depth incl. connectors!
page 56PacDrive MC-4ELAU AG
PDM_OpMaMC-4_06_us.FM
Page 57
Korrekturausdruck
PacDrive MC-4 / 50 A
23 (0.91)
72KL
CONTROL
LISTED
EQUIPMENT)
(INDUSTRIAL
C US
Instructions see cover side!
Hinweise siehe Seitenwand!
ACHTUNG: Hochspannung!
WARNING: High voltage!
!
Technical Data
err
S2
S1
pow
reset
buserr
24V
24V0V0Venrdy+
310 (12.2)
240 (9.45)
X5
rdy-
iei
ieo+
47 (1.85)
feedback
diag
X6
S3
24V i/o
X1
ieo-JJ
bi+
bo+
bi-
X8
X7
Made in Germany
bo-
U
MC4_50A_Masszeichnung_us.fh8
V
W
PE
X4 ac-motorX3 dc-busX2 ac-power
db-
db-
stud bolt M6
312 (12.28)
db+
db+
6,5
51 (2.01)70 (2.76)70707051
255 (10.04)
7
220 (8.66)
MC-4
PacDrive
296 (11.7)
310 (12.2)
270 (10.63)17 (0.67)23
Vor Arbeiten am Gerät, Netzanschluß trennen. Entladezeit > 2min.
Betrieb nur mit angeschlossenem Schutzleiter.
Oberfläche des Gerätes im Betriebszustand nicht berühren.
Bei Inbetriebnahme, Installationshinweise in der Bedienungsanleitung beachten.
Operation only with connected safety ground.
Do not touch this surface under operation conditions.
Read installation instruction before installing.
Coupez l´alimentation avant de manipuler l´appareil. Temps de décharge > 2min.
Fonctionnement uniquement avec conducteur de protection raccordé.
ACHTUNG! ATTENTION!
ne touchez pas la surface de l´appareil en marche.
!
HOCHSPANNUNG!
ERHÖHTER ABLEITSTROM!
HOHE TEMPERATUR!
INSTALLATION!
HIGH VOLTAGE! Disconnect from mains supply, before working on this equipment, Electric discharge> 2min.
HIGH LEAKAGE CURRENT!
HIGH TEMPERATURE!
INSTALLATION!
HAUTE TENSION!
COURANT DE FUITE ELEVEE!
TEMPERATURE ELEVEE!
L3
L2
L1
PE
Disconetttere l`alimentazione prima di lavorare all`apparecchio. Tempo di scarica > 2min.
Operare solo con il conduttore di scarico a terra collegato.
Non toccare la superficie dell`apparecchio in funcione.
Prima della messa in funzione dell`apparecchio consultare il manuale di istruzione
Desconecten de la red antes de trabajar con este equipo, descarga electrica > 2min.
Operen solo con una conexion a tierra segura.
No toquen esta superficie durante la operacion.
ALTA TEMPERATURA!
INSTALLATIONE!
ALTO VOLTAJE!
ALTA TENSION!
ALTA TEMPERATURA!
Lean las instrucciones de montaje antes de instalar.
INSTALACION!
Respectez le manuel d´instruction lors de la mise en marche.
INSTALLATION!
ALTA TENSIONE!
ALTA DISPERSIONE DI CORRENTE!
6,5
7 (0.28)
Fig. 6-6: Dimensions of the MC-4 / 50 A
PDM_OpMaMC-4_06_us.FM
ELAU AGPacDrive MC-4page 57
Page 58
Technical Data
6.2 PacDrive BM-4
6.2.1 In General
ParameterValue
Product
configuration
Power supplySupply voltageDC 24 V (-15 / +25 %), 0.5 A
Bleeder limits- U
Power
details
I/OOutputs
EnvironmentProduct size
ApprovalApprovalsCE, UL, cUL
Product nameBM-4 bleeder module
Order numb er13 27 00 13
Bleeder
- U
Bleeder
Resistance18 Ohm
Permanent power800 W
Peak power45 kW
- relay outputsDC 20 ... 30 V / 2 A
Box size
Product weight2.5 kg
Admissible ambient temperature
- during operation
- for storage and transport
ON
OFF
DC 790 ... 820 V in 10V steps
20 V below U
see chapter Dimensions
width: 100 mm
height: 400 mm
depth: 320 mm
0 ... +55 °C
-20 °C ... +80 °C
Bleeder
ON
Korrekturausdruck
Table 6-20: Technical data of the PacDrive BM-4 bleeder module
6.2.2 Display and operating units
reset
reset
pow
err
Button to reset the PacDrive BM-4. Only the bleeder module is
rebooted when you press the „reset“ button. Other PacDrive
components have their own „reset“ buttons.
pow
The „pow“ LED indicates the state of the control voltage.
OFFcontrol voltage (24 V) missing or too low.
ONnormal operation; control voltage in normal range
err (error indicator)
The error LED (err) indicates errors. The table below listspossible
states of the error LED with corresponding error descriptions.
page 58PacDrive MC-4ELAU AG
PDM_OpMaMC-4_06_us.FM
Page 59
Technical Data
OFFnormal operation
Korrekturausdruck
Flashing slow ly
(on:500ms / off: 2000ms)
Flashing fast
(an:500ms / aus:500ms)
ONbleeder error
bla (bleeder active)
bla
When the PacDrive BM-4 is in a active condition, the displ a y
shines „bla“.
6.2.3 Interface
control voltage X1
bleeder I²t at the limit
-DC-circuit voltage too high
- supply voltage too low
- temperature too hig h (no re set ne cess ary; th e dev ice is
ready-to-operate again after cooling down)
CUS
CUS
LISTED
LISTED
(INDUSTRIAL
(INDUSTRIAL
CONTROL
CONTROL
EQUIPMENT)
EQUIPMENT)
reset
pow
err
bla
24V
0V
n.c.
n.c.
BM-4
X1
24V/0
72KL
24V
0V
rdy
rdy
Vor Arbeiten am Gerät, Netzanschluß trennen. Entladezeit > 2min.
Disconnect from mains supply, before working on this equipment, Electric discharge > 2min.
Coupez l´alimentation avant de manipuler l´appareil. Temps de décharge > 2min.
Disconetttere l`alimentazione prima di lavorare all`apparecchio. Tempo di scarica > 2min.
Desconecten de la red antes de trabajar con este equipo, descarga electrica > 2min.
X3
DC circuit X3
db+
db+
db-
db-
Uin: 820V DC
BM4/00/00
Made in Germany
dc-bus
Uin: 24V DC/ 0,7A
HW 0000000
00000000
000000.0100
HOCHSPANNUNG!
HIGH VOLTAGE!
HAUTE TENSION!
ALTA TENSIONE!
ALTO VOLTAJE!
!
Non toccare la superficie dell`apparecchio in funcione.
Do not touch this surface under operation conditions.
No toquen esta superficie durante la operacion.
Ne touchez pas la surface de l´appareil en marche.
Oberfläche des Gerätes im Betriebszustand nicht berühren.
TUR!
TURE!
ALTA TEMPERATURA!
ALTA TEMPERATURA!
TEMPERATURE ELEVEE!
HIGH TEMPERA
HOHE TEMPERA
PE connection
PDM_Anschlussübersicht_BM-4_us0001.FH8
Fig. 6-7: Overview of connections of the BM-4 bleeder module
PDM_OpMaMC-4_06_us.FM
ELAU AGPacDrive MC-4page 59
Page 60
Technical Data
+
+
6.2.4 Electrical Connections
X1 - power supply / watchdog
Pin
Designation
MeaningRange
1DC +24Vsupply voltage-15% / +25%1.5 mm
5
1
6
2
7
3
8
4
2DC 0Vsupply voltage1.5 mm
3reserved1.5 mm
4reserved1.5 mm
5DC +24Vsupply voltage-15% / +25%1.5 mm
6DC 0Vsupply voltage1.5 mm
7rdyready1.5 mm
8rdyready1.5 mm
Max.
cross
section
2
2
2
2
2
2
2
2
Korrekturausdruck
Table 6-21: Electrical connections of the BM-4 / X1
X2 - DC-circuit
db
db
db-
db-
Pin
1db +D C-circuit voltage +DC 530 - 860 V2.5 mm
2db +D C-circuit voltage +DC 530 - 860 V2.5 mm
Designation
MeaningRange
3db -DC-circuit voltage -DC 530 - 860 V2.5 mm
4db -DC-circuit voltage -DC 530 - 860 V2.5 mm
Max.
cross
section
2
2
2
2
Table 6-22: Electrical connections of the BM-4 / X2
CAUTION!
No safe contact!
Cable and clamp may be damaged!
For cables with a cross section of 2.5 mm
2
, use end sleeves
without plastic collar and a length of at least 12 mm or end
sleeves with plastic collar and a metal sleeve that is at least 12
mm long.
page 60PacDrive MC-4ELAU AG
PDM_OpMaMC-4_06_us.FM
Page 61
6.2.5 Dimension s
Technical Data
Korrekturausdruck
view from side
209 (8.23)
7 (0.28)
23 (0.91)
296 (11.65)
270 (10.63)
17 (0.67)
7.0(0.28)
310 (12.20)
front view
34 (1.34)
Ø6.5
(0.26)
pow
err
bla
reset
24V
0V
n.c.
n.c.
X1
24V/0
X3
dc-bus
db+
db+
db-
db-
Uin: 820V DC
Uin: 24V DC/ 0,7A
BM4/00/00
00000000
Made in Germany
PDM_BM4_Ansicht_us0001.FH8
34
CUS
CUS
LISTED
LISTED
(INDUSTRIAL
(INDUSTRIALCONTROL
CONTROL
EQUIPMENT)
EQUIPMENT)
BM-4
72KL
24V
0V
rdy
rdy
Vor Arbeiten am Gerät, Netzanschluß trennen. Entladezeit > 2min.
Disconnect from mains supply, before working on this equipment, Electric discharge > 2min.
Coupez l´alimentation avant de manipuler l´appareil. Temps de décharge > 2min.
Disconetttere l`alimentazione prima di lavorare all`apparecchio. Tempo di scarica > 2min.
Desconecten de la red antes de trabajar con este equipo, descarga electrica > 2min.
HOCHSPANNUNG!
HIGH VOLTAGE!
HAUTE TENSION!
ALTA TENSIONE!
ALTO VOLTAJE!
!
No toquen esta superficie durante la operacion.
Non toccare la superficie dell`apparecchio in funcione.
Ne touchez pas la surface de l´appareil en marche.
Do not touch this surface under operation conditions.
Oberfläche des Gerätes im Betriebszustand nicht berühren.
HW 0000000
000000.0100
HIGH TEMPERATURE!
HOHE TEMPERATUR!
ALTA TEMPERATURA!
ALTA TEMPERATURA!
TEMPERATURE ELEVEE!
68 (2.67)
Fig. 6-8: Dimensions of the BM-4 bleeder module
PDM_OpMaMC-4_06_us.FM
ELAU AGPacDrive MC-4page 61
Page 62
Technical Data
6.3 PacDrive Mains Filter
6.3.1 In General
Following are the mains filters for all service types of the PacDrive
system. The characteristics the mains fil ters stand for are:
high symmetrical and asymmetrical damping
rated voltage 3 AC 480 V
compact design
touch-proof clamps
in accordance with UL 1283
ParameterValue
mechanical designaluminium housing
Korrekturausdruck
rated voltage3 AC 480 V
operating frequency50 / 60 Hz
leakage current ( bei 50 Hz)< 35 mA (3 phases) 100 mA (max.)
temperature range-25 ... +50 °C
connectionL1 / L2 / L3:
Table 6-23: Technical data of the mains filter in general
Mains filter 3X08 K-K
ParameterValue
product namemains filter FFU 3X08 K-K
order numberFI07876
rated power8 A
power loss4 W
connection cross-section4 mm
2
weight0.6 kg
Table 6-24: Technical data of the mains filter FFU 3X08 K-K
page 62PacDrive MC-4ELAU AG
PDM_OpMaMC-4_06_us.FM
Page 63
Korrekturausdruck
Technical Data
Mains filter FFU 3X30 K-K
ParameterValue
product namemains filter FFU 3X30 K-K
order numberFI07877
rated power30 A
power loss12 W
connection cross- se cti on10 mm
weight1.3 kg
Table 6-25: Technical data of the mains filter FFU 3X30 K -K
Mains filter FFU 3X55 K-K
ParameterValue
product namemains filter FFU 3X55 K-K
order numberFI07878
rated power55 A
power loss18 W
connection cross- se cti on16 mm
weight1.9 kg
2
2
Table 6-26: Technical data of the mains filter FFU 3X55 K -K
NOTE
If you need mains filters with higher rated currents, please contact
our application department.
6.3.2 Electrica l Connections
Line / NetzLoad / Last
L1
L2
L3
L1
PE
C1
C2
C3
R2
L2
R1
PD_Netzfilter_FFU3Xprinzip.FH8
L1.1
L2.1
L3.1
PE'
Fig. 6-9: Principle circuit diagram of the mains filter FFU 3X.. K-K
PDM_OpMaMC-4_06_us.FM
ELAU AGPacDrive MC-4page 63
Page 64
Technical Data
6.3.3 Electrical Connections
FI 07876 / 8A
L
F
H
C
E
U
FI07876
Load/Last
G
L1.1 L2.1 L3.1
C
FFU 3X08 K-K
Line Filter 3AC 480V 8A
8A @ 50°C
3 x AC 480V 50/60 Hz
DANGER !
!
High Voltage.
Danger of electrical shock.
GEFAHR !
!
Hohe Spannung.
Lebensgefahr.
Ground (PE) must always be
connected.
Do not touch electrical
connections when switched on.
Stets mit Erd-/Schutzleiter
fest verbinden.
Im Betrieb Anschlussklemmen
nicht berühren.
Line/Netz
L1 L2 L3
A
Fig. 6-10: Dimensional drawing of the mains filters
product name
(order no.)A[mm]B[mm]C[mm]D[mm]E[mm]F[mm]G[mm]
FFU 3X08 K-K
(FI07876)
FFU 3X30 K-K
(FI07877)
FFU 3X55 K-K
(FI07878)
Table 6-27: Dimensions of the mains filters
1904070201801605,4M5185
2705085302552405,4M5265
2508590602352205,4M6258
B
D
PD_Netzfilter_FFU3XAbmess.FH8
HL
[mm]
Korrekturausdruck
page 64PacDrive MC-4ELAU AG
PDM_OpMaMC-4_06_us.FM
Page 65
Technical Data
6.4 PacDrive Mains Choke
6.4.1 Application of mains choke
The use of PacDrive systems requires protection measures in the
network supply of the PacDrive servo drives. For each mains
contactor group, the insertion of a separate choke is necessary.
Korrekturausdruck
L1
L2
L3
Q1
~
~
~
FI
NKD XX / X.XXNKD XX / X.XXNKD XX / X.XX
K1.1
L1
L2
L3
db+
db-
MC-4MC-4
K1.2K1.3
L1
L2
L3
db+
db-
...
1 to n
L1
L2
L3
db+
db-
MC-4MC-4
...
1 to n
L1
L2
L3
db+
db-
L1
L2
L3
db+
db-
MC-4MC-4
AnschlussNetzdrossel_us.fh8
...
1 to n
L1
L2
L3
db+
db-
Fig. 6-11: Schematic diagram for the use of the mains chokes
For a failure-free operation, you have to have the correct dimensioning
of the mains choke. The dimensioning is based upon the effective
power of the respective mains contactor group.
There are three different const ruction sizes available:
Der Hersteller erklärt, dass das gelieferte
Produkt in Übereinstimmung mit den
angewendeten harmonisierten Normen /
Spezifikationen hergestellt worden ist.
Fig. 7-1: PacDrive MC-4 Hard- and Software compatibility
V00.16.xx
V00.20.xx
...
V00.16.xx
V00.20.xx
...
V00.16.xx
V00.20.xx
...
PDM_OpMaMC-4Aen_us.FM
ELAU AGPacDrive MC-4page 73
Page 74
Appendix
7.7 Modificatio ns
01 / 1999
Operating Manual newly written
07 / 1999
Terms such as MAx-4, MC-4 and P acDrive™ M adjusted
Sales regions updated
12 / 1999
Struc ture of the document modified
Description of the 22 A MC-4 improved
Korrekturausdruck
01 / 2001
MC-4 / 50 / 400 new
Mains filter HLD 110-500/55 new
Various errors cleared and improvements made
08 / 2004
Included new mains filter series
Over-worked the structure of the document
Various errors cleared and improvements made
Adjusted product names and terms
05 / 2005
Included new chapter „Mains Choke“
12/ 2005
MC-4 / 1.5 A
NOTE
The latest documentation and modification service on this product
are available on the ELAU Homepage (http://www.elau.de).