Elation ZCL BAR Z300 IP Users Manual

|
|
ZCL BAR Z300 IP™
user manual
ZCL BAR Z300 IP
user manual
©2016 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
www.elationlighting.com
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
DOCUMENT VERSION
Please check www.elationlighting.com for the latest revision/update of this manual.
DMX
Channel Modes
Notes
Date
11/22/16
Document
Version
1
Software
Version
1U 101
5 / 6 / 7 / 9 / 12 / 21 / 28 Initial release.
1U 101
2 ZCL BAR Z300 IP™ User Manual
CONTENTS
General Information
4
Warranty
7
Safety Instructions and Guidelines
8
Overview
10
Installation
11
System Menu
14
DMX Channel Functions And Values
17
Cleaning and Maintenance
22
Technical Specifications
23
Optional Accessories
25
www.elationlighting.com
3 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable IP65 rated lighting fixtures on the market today! This fixture has been
designed to perform reliably for years when the guidelines in this booklet are
followed. Please read and understand the instructions in this manual carefully
and thoroughly before attempting to operate this unit. These instructions contain
important information regarding safety during use and maintenance.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as "IP" (Ingress Protection) followed by two numbers (i.e. IP65) where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture and the second digit (Water Protection) indicates the extent of protection against water entering the fixture. An IP65 rated lighting fixture is one, which has been designed and tested to protect against the ingress of dust (6) and high-pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS!
Please note although this fixture is IP rated, the fixture is NOT suitable for marine and/or coastal environment installations. Installing this fixture in a marine and/or coastal environment may cause corrosion and/or excessive wear to the interior and/or exterior components of the fixture. Damages and/or performance issues resulting from installation in a marine and/or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and/or repairs.
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A
NON-CONDUCTIVE DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL
SUPPLIERS) TO PREVENT WATER INGRESS/CONDENSATION AND/OR CORROSION.
OPTIONAL CORROSION- RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture. Please consult your Elation Professional sales representative for details.
4 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are
missing, please contact our customer support team for further instructions. Please
do not return this unit to your dealer without first contacting customer support at
the number listed below. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
(1) powerCON TRUE1 Cable
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
5 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card to validate your
purchase. All returned service items whether under warranty or not, must be
freight pre-paid and accompany a return authorization (R.A.) number. The R.A.
number must be clearly written on the outside of the return package. A brief
description of the problem as well as the R.A. number must also be written down
on a piece of paper and included in the shipping container. If the unit is under
warranty, you must provide a copy of your proof of purchase invoice. Items
returned without a R.A. number clearly marked on the outside of the package
will be refused and returned at customer’s expense. You may obtain a R.A.
number by contacting customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
6 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional® product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professional® factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional® concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional® factory unless prior written authorization was issued to purchaser by Elation Professional®; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual. D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional® will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional®. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect. E. Elation Professional® reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional® in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
7 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
This fixture is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow all instructions and guidelines
in this manual. The manufacturer of this device is not responsible for injury and/or
damages resulting from the misuse of this fixture due to the disregard of the
information printed in this manual. Only qualified and/or certified personnel should
perform installation of this fixture and only the original rigging parts (omega brackets)
included with this fixture should be used for installation. Any modifications to the
fixture and/or the mounting hardware included will void the original manufactures
warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED
WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL
SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL
SHORT CIRCUIT.
8 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and
allow approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped and/or
damaged. If the power cord is damaged, replace it immediately with a new one
of similar power rating.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and
never blocked. Allow approx. 6” (15cm) between fixture and other devices or a
wall for proper cooling.
When installing fixture in a suspended environment, always use mounting
hardware that is no less than M10 x 25 mm, and always install fixture with an
appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug
end, never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
Consistent operational breaks will ensure the fixture will function properly for
many years to come.
Use the original packaging and materials to transport the fixture in for service.
9 ZCL BAR Z300 IP™ User Manual
OVERVIEW
www.elationlighting.com
SAFETY CABLE RIGGING POINTS
10 ZCL BAR Z300 IP™ User Manual
INSTALLATION
Keep fixture at least 5.0 ft (1.5m) away from any
A qualified electrician should be used for all
www.elationlighting.com
FLAMMABLE MATERIAL WARNING
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
electrical connections and/or installations.
CAUTIONS
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A
DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT
WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 5° to 113°F. (-15° to 45°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
11 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
CLAMP INSTALLATION
The fixture provides an integrated adjustable yoke with rotating floor stands. When
mounting this fixture to truss, (2) Omega Brackets (optional not included) are
required. Be sure to secure appropriately rated clamps to the Omega Brackets. Be
sure to attach an appropriate Safety Cable (not included) to the fixture using the
safety cable rigging points integrated in the fixture.
RIGGING
Overhead rigging requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic safety
inspection of all installation material and the fixture. If you lack these qualifications,
do not attempt the installation yourself. Improper installation can result in bodily
injury. Fixture is fully operational in the specific mounting positions illustrated below.
SAFETY CABLE
ALWAYS USE A SAFETY CABLE
WHENEVER INSTALLING THIS FIXTURE
IN A SUSPENDED ENVIRONMENT TO
ENSURE THE FIXTURE WILL NOT DROP
IF THE CLAMPS FAILS.
12 ZCL BAR Z300 IP™ User Manual
POWER LINKING
Max number of ZCL BAR Z300 IP™ units power linked together:
2 units @120V | 5 units @240V
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO ZCL BAR Z300 IP™!
POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
ALWAYS CHECK MAX AMP OUT RATING PRINTED ON THE REAR CONNECTION PANEL!
www.elationlighting.com
13 ZCL BAR Z300 IP™ User Manual
ZOOM
ELATION
ZCL Bar
www.elationlighting.com
SYSTEM MENU
The fixture includes an easy to navigate system menu control panel display where all
necessary setting adjustments are made. (See image below) During normal
operation, pressing the MODE button once will access the main menu. Once in the
main menu you can navigate through the different functions and access sub-menus
with the UP and DOWN buttons. Once you reach a field that requires adjusting, press
the ENTER button to activate that field and use the UP and DOWN buttons to adjust
the field. Pressing the ENTER button once more will confirm your setting. You may exit
the main menu at any time without making any adjustments by pressing the
MODE/ESC button.
LCD CONTROL PANEL LOCKOUT FEATURE
When the Key Lock menu (Function | LCD. Set | Key Lock) is set to ON (default setting), the LCD control panel display will turn OFF and become LOCKED after non-use. To UNLOCK, press the MODE button.
When the Key Lock menu is set to ON1 mode, follow these steps to UNLOCK the LCD display:
1. When locked, the display will show: LOCKED*****
2. Press UP, then the display will change to: LOCKED**** (one * disappears)
3. Press DOWN, then the display will change to: LOCKED*** (two * disappear)
4. Press UP, then the display will change to: LOCKED** (three * disappear)
5. Press DOWN, then the display will change to: LOCKED* (4 * disappear)
6. Press ENTER, then the display will change to LOCKED and then become unlocked.
INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:
Update Wait...
14 ZCL BAR Z300 IP™ User Manual
Reset...
V1.01
Z300 IP
ELATION© ZCL BAR Z300 IP™ | S Y S T E M M E N U
Features are subject to change without any prior written notice.
OPTIONS / VALUES
BOLD)
Set ADDR
Set ADDR
001 ~ 508
DMX Address Setting
UserMode
CH:05, 06, 07, 09, 12, 21, 28
Set DMX Channel / User Mode
DimCurve
Standard, Stage, TV, Architectur, Theatre
Set Dimmer Curve Mode
No DMX
Hold / Blackout / Program
Function If NO DMX Detected
ZOOM
000 - 255
Zoom Control for Auto Run Programs
AUTO RUN
FQN:00-99
Set Number of Times Internal Program Repeats
CL:R, G, B, RG, GB, RB, RGB, BLAC
Internal Program #1 Select COLOR and Adjust FLASH
F: 00-99
02.DREAM
SP:01-99 | F:00-99
Internal Prog#2 Adjust SPEED and FLASH
03.METOR
SP:01-99 | F:00-99
Internal Prog#3 Adjust SPEED and FLASH
04.FADE
SP:01-99 | F:00-99
Internal Prog#4 Adjust SPEED and FLASH
05.CHANG
SP:01-99 | F:00-99
Internal Prog#5 Adjust SPEED and FLASH
06.FLOW1
SP:01-99 | F:00-99
Internal Prog#6 Adjust SPEED and FLASH
07.FLOW2
SP:01-99 | F:00-99
Internal Prog#7 Adjust SPEED and FLASH
08.FLOW3
SP:01-99 | F:00-99
Internal Prog#8 Adjust SPEED and FLASH
09.FLOW4
SP:01-99 | F:00-99
Internal Prog#9 Adjust SPEED and FLASH
10.FLOW5
SP:01-99 | F:00-99
Internal Prog#10 Adjust SPEED and FLASH
11.FLOW6
SP:01-99 | F:00-99
Internal Prog#11 Adjust SPEED and FLASH
12.FLOW7
SP:01-99 | F:00-99
Internal Prog#12 Adjust SPEED and FLASH
Flip
OFF, ON
Set starting LED, see FLIP Section for more info.
Macros
00-63
Select Color Macro Value
Backligh
02~60m 05m
LCD Backlight Shut Off Time
Key Lock
ON / ON1, OFF
Control Front Panel Buttons Key Lock
DisFlash
ON / OFF
Display flashes when NO DMX
DFSET
ON / OFF
Restore Factory Settings
TEMP
Fahren / Celsius
(5=@5B1DEB5'G9D385DG55>OO
TimerPIN
PIN= 066
Enter PIN to Access Clear Last/Clear Total Menus
Current
XXXX (Hours)
Fixture Run Time From Power ON
TotalTim
XXXX (Hours)
Fixture Total Run Time
Last Clea
XXXX (Hours)
Clear Fixture Last Run Time
TempInfo
xxx°F
XXX F° / C°
Displays Temperature in Fixture Head
ModelInf
ELATION
Display Model Name
ErrorInf
Error Record 1 ~ Error Record 10
Display 10 Recent Error Messages
Software
1U V101
2U V101
Software Versions
Reset. M
ZOOM
Reset of Zoom Motor
Calibrate
Password
Password= 050
Calibration of LEDS (RGBW) and Zoom Motor
SLAVE
SLAVE
Slave Mode
ZOOM
000 - 255
Set Manual Zoom DMX Value
Dimmer
000 - 255
Set Manual Master Dimmer DMX Value
RED
000 - 255
Set Manual RED DMX Value
GREEN
000 - 255
Set Manual GREEN DMX Value
BLUE
000 - 255
Set Manual BLUE DMX Value
WHITE
000 - 255
Set Manual WHITE DMX Value
Strobe
000 - 255
Set Manual STROBE DMX Value
www.elationlighting.com
MAIN MENU SUB MENU
01.STATC
Function
LCD.Set
(Default Settings in
DESCRIPTION
Info
Test
Manual
TimeInfo
Manual
15 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
Function - DimCurve
Select desired DIMMER MODE (Standard, Stage, TV, Architectural, Theatre).
Flip
Select the desired starting LED and chase direction from one of the following modes below via UP/DOWN buttons and then press ENTER to confirm. (Default = OFF)
FLIP = OFF FLIP = ON
16 ZCL BAR Z300 IP™ User Manual
ELATION© ZCL BAR Z300 IP™
DMX Channel Values / Functions Version (28 DMX Channels)
Supports Software Versions: 1.01
www.elationlighting.com
DMX CHANNEL FUNCTIONS AND VALUES
*Rotation (Clockwise or Counterclockwise) and direction of effects depends on orientation of the fixture head and Pan/Tilt settings.
Features are subject to change without any prior written notice.
MODE / CHANNEL
CH:05 CH:06 CH:07 CH:09 CH:12 CH:21 CH:28
1 1 1 1 1 0-255
2 2 2 2 2 0-255
3 3 3 3 3 0-255
4 4 4 4 4 0-255
1 1 0-255
2 2 0-255
3 3 0-255
4 4 0-255
5 5 0-255
6 6 0-255
7 7 0-255
8 8 0-255
9 9 0-255
10 10 0-255
11 11 0-255
12 12 0-255
VALUE FUNCTION
RED [ALL LEDs]
0 to 100%
GREEN [ALL LEDs]
0 to 100%
BLUE [ALL LEDs]
0 to 100%
WHITE [ALL LEDs]
0 to 100%
RED [LED #1]
0 to 100%
GREEN [LED #1]
0 to 100%
BLUE [LED #1]
0 to 100%
WHITE [LED #1]
0 to 100%
RED [LED #2]
0 to 100%
GREEN [LED #2]
0 to 100%
BLUE [LED #2]
0 to 100%
WHITE [LED #2]
0 to 100%
RED [LED #3]
0 to 100%
GREEN [LED #3]
0 to 100%
BLUE [LED #3]
0 to 100%
WHITE [LED #3]
0 to 100%
17 ZCL BAR Z300 IP™ User Manual
Supports Software Versions: 1.01
CH:05
CH:06
CH:07
CH:09
CH:12
CH:21
CH:28
www.elationlighting.com
*Rotation (Clockwise or Counterclockwise) and direction of effects depends on orientation of the fixture head and Pan/Tilt settings.
Features are subject to change without any prior written notice.
MODE / CHANNEL
13 13 0-255
14 14 0-255
15 15 0-255
16 16 0-255
17 17 0-255
18 18 0-255
19 19 0-255
20 20 0-255
5 5 21
6 6 22
7 7 23
VALUE FUNCTION
RED [LED #4]
0 to 100%
GREEN [LED #4]
0 to 100%
BLUE [LED #4]
0 to 100%
WHITE [LED #4]
0 to 100%
RED [LED #5]
0 to 100%
GREEN [LED #5]
0 to 100%
BLUE [LED #5]
0 to 100%
WHITE [LED #5]
0 to 100%
0-31 LED OFF
32-63 LED ON
64-95 Strobe Effect SLOW to FAST
96-127 LED ON
128-159 Pulse Effect in Sequences
160-223 Random Strobe Effect SLOW to FAST
224-255 LED ON
0-255
0-255
SHUTTER / STROBE
DIMMER INTENSITY
Dimmer 0 to 100%
DIMMER INTENSITY FINE
Dimmer FINE Adjustment
18 ZCL BAR Z300 IP™ User Manual
Supports Software Versions: 1.01
CH:05
CH:06
CH:07
CH:09
CH:12
CH:21
CH:28
www.elationlighting.com
*Rotation (Clockwise or Counterclockwise) and direction of effects depends on orientation of the fixture head and Pan/Tilt settings.
Features are subject to change without any prior written notice.
MODE / CHANNEL
8 24
VALUE FUNCTION
0 OFF
1-4 COLOR PRESET 01
5-8 COLOR PRESET 02
9-12 COLOR PRESET 03
13-16 COLOR PRESET 04
17-20 COLOR PRESET 05
21-24 COLOR PRESET 06
25-28 COLOR PRESET 07
29-32 COLOR PRESET 08
33-36 COLOR PRESET 09
37-40 COLOR PRESET 10
41-44 COLOR PRESET 11
45-48 COLOR PRESET 12
49-52 COLOR PRESET 13
53-56 COLOR PRESET 14
57-60 COLOR PRESET 15
61-64 COLOR PRESET 16
65-68 COLOR PRESET 17
69-72 COLOR PRESET 18
73-76 COLOR PRESET 19
77-80 COLOR PRESET 20
81-84 COLOR PRESET 21
85-88 COLOR PRESET 22
89-92 COLOR PRESET 23
93-96 COLOR PRESET 24
97-100 COLOR PRESET 25
101-104 COLOR PRESET 26
105-108 COLOR PRESET 27
109-112 COLOR PRESET 28
113-116 COLOR PRESET 29
117-120 COLOR PRESET 30
121-124 COLOR PRESET 31
125-128 COLOR PRESET 32
COLOR PRESETS
19 ZCL BAR Z300 IP™ User Manual
Supports Software Versions: 1.01
CH:05
CH:06
CH:07
CH:09
CH:12
CH:21
CH:28
www.elationlighting.com
*Rotation (Clockwise or Counterclockwise) and direction of effects depends on orientation of the fixture head and Pan/Tilt settings.
Features are subject to change without any prior written notice.
MODE / CHANNEL
8 24
VALUE FUNCTION
129-132 COLOR PRESET 33
133-136 COLOR PRESET 34
137-140 COLOR PRESET 35
141-144 COLOR PRESET 36
145-148 COLOR PRESET 37
149-152 COLOR PRESET 38
153-156 COLOR PRESET 39
157-160 COLOR PRESET 40
161-164 COLOR PRESET 41
165-168 COLOR PRESET 42
169-172 COLOR PRESET 43
173-176 COLOR PRESET 44
177-180 COLOR PRESET 45
181-184 COLOR PRESET 46
185-188 COLOR PRESET 47
189-192 COLOR PRESET 48
193-196 COLOR PRESET 49
197-200 COLOR PRESET 50
201-204 COLOR PRESET 51
205-208 COLOR PRESET 52
209-212 COLOR PRESET 53
213-216 COLOR PRESET 54
217-220 COLOR PRESET 55
221-224 COLOR PRESET 56
225-228 COLOR PRESET 57
229-232 COLOR PRESET 58
233-236 COLOR PRESET 59
237-240 COLOR PRESET 60
241-244 COLOR PRESET 61
245-248 COLOR PRESET 62
249-252 COLOR PRESET 63
253-255 COLOR PRESET 64
COLOR PRESETS [continued]
20 ZCL BAR Z300 IP™ User Manual
Supports Software Versions: 1.01
CH:05
CH:06
CH:07
CH:09
CH:12
CH:21
CH:28
www.elationlighting.com
*Rotation (Clockwise or Counterclockwise) and direction of effects depends on orientation of the fixture head and Pan/Tilt settings.
Features are subject to change without any prior written notice.
MODE / CHANNEL
25
10 26 0-255
8 11 21 27
9 12 28
VALUE FUNCTION
0 NO FUNCTION
1-20 PROGRAM MACRO 01
21-40 PROGRAM MACRO 02
41-60 PROGRAM MACRO 03
61-80 PROGRAM MACRO 04
81-100 PROGRAM MACRO 05
101-120 PROGRAM MACRO 06
121-140 PROGRAM MACRO 07
141-160 PROGRAM MACRO 08
161-180 PROGRAM MACRO 09
181-200 PROGRAM MACRO 10
201-230 PROGRAM MACRO 11
231-240 PROGRAM MACRO 12
241-250 PROGRAM MACRO 13
251-255 PROGRAM MACRO 14
0-255
0-20 STANDARD
21-40 STAGE
41-60 TV
61-80 ARCHITECTURAL
81-100 THEATRE
101-255 Default to Unit Setting
PROGRAM MACROS
PROGRAM MACRO SPEED
SLOW to FAST Speed
ZOOM
Zoom 0% (4 Degrees) to 100% (44 Degrees)
DIMMING CURVE MODES
21 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
C LEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.
Never use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three months,
to make sure the circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws may
fall out during normal operation resulting in damage or injury as larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
22 ZCL BAR Z300 IP™ User Manual
www.elationlighting.com
TECHNICAL SPECIFICATIONS
SOURCE
(5) 60W 4-in-1 RGBW LEDs 100,000 Hour Average LED Life*
*May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
COLOR
RGBW
EFFECTS
RGBW Color Mixing Full Pixel Control and Pixel Order Flip 4° - 44° Motorized Zoom 64 Color Presets and 12 Unique Program Macros Electronic Strobe and Selectable Dimming Curves
CONTROL / CONNECTIONS
7 DMX Channel Modes (28 Total Channels) 4 Touch Button Control Panel and LCD Menu Display RDM (Remote Device Management) IP rated 5pin DMX and powerCON TRUE1 In/Out
SIZE / WEIGHT
Length: 26.4” (670mm) Width: 6.2” (157.8mm) Horizontal Height: 11.7” (297.6mm) Weight: 43.0 lbs. (19.5 kg)
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz 390W Max Power Consumption 5F to 113°F (-15°C to 45°C)
APPROVALS / RATINGS
CE | RoHs | IP65
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
23 ZCL BAR Z300 IP™ User Manual
PHOTOMETRIC DATA
1 m
3.3 ft
2 m
6.6 ft
3 m
9.8 ft
4 m
13.1 ft
5 m
16.4 ft
4° Beam
lux
fc
lux
fc
lux
fc
lux
fc
lux
fc
11,193
1,040
8,130
755
5,224
485
3,186
296
2,322
216
GREEN
LEDs
BLUE LEDs
4,031
374
2,471
230
1,666
155
1,179
110
928
86
WHITE LEDs
24,311
2,258
20,111
1,868
11,640
1,081
8,523
792
6,602
613
FULL ON
63,777
5,925
36,436
3,385
24,372
2,264
16,725
1,554
12,872
1,196
1 m
3.3 ft
2 m
6.6 ft
3 m
9.8 ft
4 m
13.1 ft
5 m
16.4 ft
70° Field
lux
fc
lux
fc
lux
fc
lux
fc
lux
fc
1,573
146
574
53
245
23
148
14
94
9
GREEN
LEDs
BLUE LEDs
530
49
186
17
81 8 47 4 31
3
4,581
426
1,625
151
723
67
422
39
253
24
FULL ON
9,273
861
3,100
288
1,370
127
812
75
512
48
MIN ZOOM - 4° Beam Diameter
www.elationlighting.com
Diameter
9° Field
Diameter
RED LEDs
44° Beam
Diameter
Diameter
RED LEDs
0.06 0.2
0.15 0.5
22,736 2,112
0.81 2.7
1.4 4.6
0.15 0.5
0.33 1.1
10,621 987
1.64 5.4
2.8 9.2
0.24 0.8
0.5 1.6
6,418 596
MAX ZOOM - 44° Beam Diameter
2.47 8.1
4.2 13.8
0.33 1.1
0.68 2.2
5,928 551
3.29 10.8
5.6 18.4
0.41 1.3
0.85 2.8
4,087 380
4.12 13.5
7 23.0
WHITE LEDs
2,835 263
969 90
448 42
246 23
173 16
24 ZCL BAR Z300 IP™ User Manual
DIMENSIONAL DRAWINGS
www.elationlighting.com
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
OPTIONAL ACCESSORIES
ORDER CODE ITEM
NARROW CLAMP PRO 2” Wrap Around Clamp
8050000053 Omega Bracket (107mm)
SCABLE60 24” (610mm) 60 lbs. (27 kg) Rated Safety Cable
NEU088 3 ft. (1m) PowerCON TRUE1 Power Link Cable
Additional Cable Lengths Available
25 ZCL BAR Z300 IP™ User Manual
Loading...