Elation WW Profile User Manual

Page 1
|
|
WW PROFILE™
user manual
WW PROFILE
user manual
Page 2
www.elationlighting.com
©2016 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
DOCUMENT VERSION
Please check www.elationlighting.com for the latest revision/update of this manual.
Date
5/2015 1
2/18/16 2
Document
Version
Software
Version
1.0.1
1.0.2
DMX
Channel Modes
1/ 4 ETL version.
1/ 4
Notes
Added LED Calibration, Refresh Rate and
Gamma menus.
2 WW PROFILE™ User Manual
Page 3
CONTENTS
General Information
4
Warranty
6
Safety Instructions
7
General Guidelines
8
Fixture Overview
9
Lens and Gobo Holder Installation
10
Fixture Installation
11
Fixture Menu
14
DMX Channel Functions And Values
23
Cleaning and Maintenance
24
Technical Specifications
25
Optional Accessories
27
www.elationlighting.com
3 WW PROFILE™ User Manual
Page 4
www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable lighting fixtures on the market today! This fixture has been designed to
perform reliably for years when the guidelines in this booklet are followed. Please
read and understand the instructions in this manual carefully and thoroughly
before attempting to operate this unit. These instructions contain important
information regarding safety during use and maintenance.
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to
operate the unit have arrived intact. In the event damage has been found or
parts are missing, please contact our customer support team for further
instructions. Please do not return this unit to your dealer without first contacting
customer support at the number listed below. Please do not discard the shipping
carton in the trash. Please recycle whenever possible.
4 WW PROFILE™ User Manual
Page 5
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
www.elationlighting.com
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid
and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the
problem as well as the R.A. number must also be written down on a piece of
paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a
R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting
customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
5 WW PROFILE™ User Manual
Page 6
www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to
be free of manufacturing defects in material and workmanship for a period of two years (730 days),
and Elation Professional® product rechargeable batteries to be free of manufacturing defects in
material and workmanship for a period of six months (180 days), from the original date of purchase.
This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only
if the product is purchased within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at
the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts replacement) are within
the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated
point within the United States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any accessories are
shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or
damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the
product is modified in any manner which Elation Professional® concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the
Elation Professional® factory unless prior written authorization was issued to purchaser by Elation
Professional®; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of Elation Professional® under
this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at
the sole discretion of Elation Professional®. All products covered by this warranty were manufactured
after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional® reserves the right to make changes in design and/or performance
improvements upon its products without any obligation to include these changes in any products
theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional® in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above.
And no warranties, whether expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole
remedy shall be such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
6 WW PROFILE™ User Manual
Page 7
is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow the guidelines in this
manual. The manufacturer of this device will not accept responsibility for
lting from the misuse of this fixture due to the disregard of the
. It’s essential this device be
perform all electrical
SAFETY INSTRUCTIONS
www.elationlighting.com
This fixture
damages resu
information printed in this manual.
This device falls under PROTECTION CLASS 1
grounded properly. Only qualified personnel should
connections.
INDOORS USE ONLY!
DO NOT EXPOSE FIXTURE RAIN AND MOISTURE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
For proper operation, follow the Installation guidelines described in this manual. Only qualified
and certified personnel should perform installation of this fixture and only the original rigging parts
(brackets) included with this fixture should be used for installation. Any modifications will void the
original manufactures warranty and increase the risk of damage and/or personal injury.
Never look directly into the light source of this fixture to prevent risk of injury to your retina, which
may induce blindness. Those suffering from EPILEPSY should avoid looking directly into the light
source of this unit at all times.
The fan and air inlets must remain clean and never blocked. Allow approx. 6” (15cm) between
this fixture and other devices or a wall for proper cooling.
Always disconnect from main power source before performing any type of service and/or
cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by
tugging the wire portion of the cord.
Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If
the power cord is damaged, replace it immediately with a new one of similar power rating.
7 WW PROFILE™ User Manual
Page 8
www.elationlighting.com
GENERAL GUIDELINES
NEVER OPEN THIS FIXTURE WHILE IN USE!
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
This fixture is a professional lighting effect designed for INDOOR / DRY LOCATIONS
ONLY on stage, in nightclubs, theatres, etc.
Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while
operating, to prevent any fire hazard.
The fixture must be installed in a location with adequate ventilation, at least 1.5
feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked.
DO NOT attempt installation and/or operation without knowledge how to do so.
DO NOT permit operation by persons who are not qualified to operate this type
of fixture. Most damages are the result of operations by nonprofessionals.
Consistent operational breaks may ensure the fixture will function properly for
many years to come.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
Always install the fixture with an appropriate safety cable. When installing the
fixture in a suspended environment, always use mounting hardware that is no less
than M10 x 25 mm, also be sure the hardware is insert in the pre-arranged screw
holes in the bracket of the fixture.
Use the original packaging and materials to transport the fixture in for service.
DO NOT TOUCH the housing bare-hand during its operation. Turn OFF the power
and allow approximately 15 minutes for the fixture to cool down before replacing
or serving.
8 WW PROFILE™ User Manual
Page 9
FIXTURE OVERVIEW
www.elationlighting.com
1. Lens (not included)
2. FOCUS
3. UP Button
4. DOWN Button
5. MODE/ESC Button
6. ENTER Button
7. LCD Menu Control Display
8. FUSE
9. 3pin DMX IN
10. 3pin DMX OUT
11. 5pin DMX OUT
12. 5pin DMX IN
13. powerCON IN
14. powerCON OUT
15. Mounting Yoke
16. BLADE SHUTTERS
17. ROTATION
18. Gobo Slot* *Gobo and Holder not included
9 WW PROFILE™ User Manual
Page 10
www.elationlighting.com
LENS AND GOBO HOLDER INSTALLATION
Gobo Holder (not included) Supports “B” Size Metal and HT Transparency Gobos (not included)
10 WW PROFILE™ User Manual
Page 11
Keep fixture at least 5.0 ft. (1.5m) away from any
should be used for all
FIXTURE INSTALLATION
www.elationlighting.com
FLAMMABLE MATERIAL WARNING
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualified electrician electrical connections and/or installations.
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 14° to 113°F. (-10° to 45°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
11 WW PROFILE™ User Manual
Page 12
MOUNTING POINTS
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic
safety inspection of all installation material and the device. If you lack these
qualifications, do not attempt the installation yourself. Improper installation can
result in bodily injury.
Fixture is fully operational in the specific mounting positions as illustrated below.
www.elationlighting.com
SAFETY CABLE
ALWAYS USE A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED
ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS.
12 WW PROFILE™ User Manual
Page 13
CLAMP MOUNTING
This fixture includes an adjustable mounting yoke and safety cable rigging point
attached to the fixture (see the illustration below). When mounting this fixture to truss
be sure to secure an appropriately rated clamp (not included) to the yoke using an
M10 screw fitted through the center hole of the clamp. Be sure to attach the
included Safety Cable to the fixture using the safety cable rigging point.
www.elationlighting.com
SECURING
Regardless of the rigging option you choose for your fixture always be sure to secure
your fixture with a safety cable. The fixture provides a built-in rigging point for a
safety cable on the hanging bracket as illustrated above. Be sure to only use the
designated rigging point for the safety cable and never secure a safety cable to a
carrying handle.
13 WW PROFILE™ User Manual
Page 14
www.elationlighting.com
FIXTURE MENU
ON-BOARD SYSTEM MENU
The fixture has an easy to navigate system menu. The next section will detail the
functions of each command in the system menu.
LCD MENU CONTROL PANEL
The control panel (see image below) located on the fixture allows you to access the
main menu and make all necessary adjustments to the fixture. During normal
operation, pressing MODE/ESC button once will access the fixture’s main menu.
Once in the main menu you can navigate through the different functions and
access the sub-menus with the UP and DOWN buttons. Once you reach a field that
requires adjusting, press the ENTER button to activate that field and use the UP and
DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm
your setting. You may exit the main menu at any time without making any
adjustments by pressing the MODE/ESC button.
14 WW PROFILE™ User Manual
Page 15
ELATION© WW PROFILE™
S Y S T E M M E N U
Supports Software Versions: 1.0.1
Features are subject to change without any prior written notice.
MAIN MENU
SUB MENU
OPTIONS / VALUES
DESCRIPTION
Address
001~509
DMX Address Setting
SetSlave
Slave1, Slave2, Slave3
Slave Setting
Cur Time
XXXX(Hours)
Power On Running Time
Last Hrs
XXXX(Hours)
Fixture Last Times Clear
Clr Last
ON/OFF
Clear Fixture Last Time
XXX C° / F °
Soft Ver
=1.0.1 (or greater)
Software Version
NoDMXSta
CloShut/Hold/Auto
Auto Run If No DMX
Key Lock
ON/OFF
Key Lock
ResetDef
ON/OFF
Passcode 011
Restore factory settings
ProPart2 = Prog 1~10 (Program 2)
ProgTest = T01SCxxx
Testing Program
EdStep 01 = S01SCxxx
EdStep 64 = S64SCxxx
RecCntrl
XX~XX
Automatic Scenes Recorder
www.elationlighting.com
(Default Settings in BOLD)
FuncMode
Info
Persnal
ManCntrl
Mode Set
Dimming
ValuDisp =All Ch, Auto, Red, ReF, Gree, GreF... DMX Value Display
AutoProg Master / Alone Auto Program
TotalHrs XXXX(Hours) Fixture Running Time
TimeInfo
TimePass Password=XXX Timer Password 038
TempInfo HeadTemp
Stat Set
Disp Set
Temp C/F Cels/Fahren (4<?4A0CDA4'F8C274CF44=QQ
ManCntrl
UserMode 1CH, 4CH DMX Channel Modes
Dimming Standar, Stage, TV, Archite, Theatre Dimming Modes
Addr DMX ON/OFF Address Via DMX
Off Time 02~60m OFF Display Shut Off Time
Warm = Warm=xxx : DIMo = DIMo=xxx
Temperature in Fixture
Adjust Functions Manually
EditProg
Sel Prog
EditProg
EditScen
ProPart1 = Prog 1~10 (Program 1)
ProPart3 = Prog 1~10 (Program 3)
Prog 1 : Prog 10
Scene 001 ~ Scene 250
Cool = Cool=xxx ~ InByOut = Time=xx.xs
Select Programs To Be Run
Program In Loop
Save and Exit
Save and Automatically Return Manual Scenes Edit
15 WW PROFILE™ User Manual
Page 16
ELATION© WW PROFILE™
S Y S T E M M E N U
Supports Software Versions: 1.0.2
Features are subject to change without any prior written notice.
MAIN MENU
SUB MENU
OPTIONS / VALUES
DESCRIPTION
Address
001~509
DMX Address Setting
SetSlave
Slave1, Slave2, Slave3
Slave Setting
Cur Time
XXXX(Hours)
Power On Running Time
Last Hrs
XXXX(Hours)
Fixture Last Times Clear
Clr Last
ON/OFF
Clear Fixture Last Time
XXX C° / F °
Soft Ver
=1.0.2 (or greater)
Software Version
NoDMXSta
CloShut/Hold/Auto
Auto Run If No DMX
Key Lock
ON/OFF
Key Lock
Refresh
Fq = 900 - 1500, 25000 (1200)
Refresh Frequency Rate Setting
ResetDef
ON/OFF
Passcode 011
Restore factory settings
White [255-0]
Calibrate LED
ProPart2 = Prog 1~10 (Program 2)
ProgTest = T01SCxxx
Testing Program
EdStep 01 =
EdStep 64 = S64SCxxx
www.elationlighting.com
(Default Settings in BOLD)
FuncMode
Info
Persnal
ManCntrl
ValuDisp =All Ch, Auto, Red, ReF, Gree, GreF... DMX Value Display
AutoProg Master / Alone Auto Program
TotalHrs XXXX(Hours) Fixture Running Time
TimeInfo
TimePass Password=XXX Timer Password 038
TempInfo HeadTemp
Stat Set
Disp Set
Temp C/F Cels/Fahren (4<?4A0CDA4'F8C274CF44=QQ
Gamma Gama = 2.0, 2.2, 2.4, 2.8 Gamma Setting
ManCntrl
Calibrat
Addr DMX ON/OFF Address Via DMX
Off Time 02~60m OFF Display Shut Off Time
Warm = Warm=xxx : DIMo = DIMo=xxx
Password Passcode 050 Calibration Password 050
Temperature in Fixture
Adjust Functions Manually
Mode Set
Dimming
EditProg
UserMode 1CH, 4CH DMX Channel Modes
Dimming Standar, Stage, TV, Archite, Theatre Dimming Modes
ProPart1 = Prog 1~10 (Program 1)
Sel Prog
ProPart3 = Prog 1~10 (Program 3)
Prog 1
EditProg
EditScen
RecCntrl XX~XX Automatic Scenes Recorder
: Prog 10
Scene 001 ~ Scene 250
S01SCxxx
Cool = Cool=xxx ~ InByOut = Time=xx.xs
Select Programs To Be Run
Program In Loop
Save and Exit
Save and Automatically Return Manual Scenes Edit
16 WW PROFILE™ User Manual
Page 17
www.elationlighting.com
FuncMode - Address
Define desired DMX address via the Control Panel.
FuncMode - ValuDisp
Display DMX 512 value of each channel.
FuncMode - SetSlave
Define fixture slave mode (Slave1, Slave2, Slave3).
FuncMode - AutoProg
Define fixture mode (Master or Alone) for running Auto Programs. Select desired
internal programs under “Select Program”, set the number of steps under “Edit
Program”, and edit individual scenes under “Edit Scenes”.
Info - TimeInfo - Cur Time
Displays fixture run time from last power ON.
The counter is reset after each time the fixture is powered OFF.
Info - TimeInfo - TotalHrs
Displays fixture total run time.
Info - TimeInfo - Last Hrs
Displays fixture run time for a given period of time (i.e. rental period).
This counter can be reset.
Info - TimeInfo - TimePass
Displays timer passcode. (038)
Info - TimeInfo - Clr Last
Clear fixture last run time.
Time can only be cleared after the timer password is entered.
Info - TempInfo - HeadTemp
Displays temperature of the fixture.
Info - Soft Ver
Displays software version of the fixture.
17 WW PROFILE™ User Manual
Page 18
www.elationlighting.com
Persnal - Stat Set - Addr DMX
When ON, define the desired DMX address via an external controller.
1. Connect the fixture to the external controller and power ON.
2. Set the DMX value of Channel 1 on the controller to (7).
3. Set the DMX value of Channel 2 on the controller to (7) or (8).
When set to (7), the DMX address can be set between (1) and (255).
When set to (8), the DMX address can be set between (256) and (511).
4. Using Channel 3 on the controller set the desired DMX address of the fixture.
Example 1: If the desired DMX address is 57, set Channel 1 to a value of (7), set Channel 2 to
a value of (7), and then set Channel 3 to a value of (57).
Example 2: If the desired DMX address is 420, set Channel 1 to a value of (7), set Channel 2 to
a value of (8), and then set Channel 3 to a value of (164). (256+164=420)
5. After setting Channel 3 to the desired DMX address value, wait for approximately
20 seconds for the fixture to complete the address reset function.
Define desired DMX address via an external controller.
Persnal - Stat Set - NoDMXSta
Define how fixture operates if NO DMX signal is detected.
Persnal - Disp Set – Off Time
Define how many minutes before the LCD Menu display will automatically shut OFF.
Persnal - Disp Set – Key Lock
When ON, Control Panel buttons lock automatically after exiting main menu for 15
seconds. To unlock, keep MODE/ESC button pressed for 3 seconds.
Persnal – Temp C/F
Define how fixture displays internal temperature (Celsius or Fahrenheit).
Persnal – ResetDef
When ON, all factory settings are restored.
ManCntrl – ManCntrl
Adjust functions manually.
18 WW PROFILE™ User Manual
Page 19
www.elationlighting.com
Mode Set – UserMode
Select DMX channel modes.
Dimming – DimModes
Select dimming modes (Standar, Stage, TV, Archite, Theatre).
EditProg – Sel Prog
Select one of the (10) user defined internal Auto Programs.
EditProg – EditProg
Edit any of the (10) user defined internal Auto Programs.
EditProg – EditScen
Edit any of the (250) scenes of the internal Auto Programs.
EditProg – RecCntrl
The fixture features an integrated DMX-recorder by which you can transmit the
programmed scenes from your DMX-controller to the moving head. Adjust the
desired scene numbers via the encoder (from – to). When you call up the scenes at
your controller, they will automatically be transmitted to the moving head.
19 WW PROFILE™ User Manual
Page 20
www.elationlighting.com
EditProg – RecCntrl – Working With Built In Programs
A Master unit can send up to 3 different data groups to the Slave units, i.e. a Master
unit can start 3 different Slave units, which run 3 different programs. The Master unit
sends the 3 program parts in a continuous loop.
The Slave unit receives data from the Master unit according to the group which the Slave
unit was assigned to. If e.g. a Slave unit is set to “Slave1” in the menu “SetSlave”, the Master
unit sends “ProPart 1” to the Slave unit. If set to “Slave2”, the Slave unit receives “ProPart 2”.
EditProg – RecCntrl – Working With Built-In Program [continued]
To start an Auto Program proceed as follows:
1. Slave Setting
K*5<53D“FuncMode”.
K(B5CCENTER to confirm.
K*5<53D“SetSlave”.
K(B5CC ENTER to confirm.
K*elect “Slave1”, “Slave2” or “Slave3”.
K(B5CCENTER to confirm.
K(B5CCMODE/ESC in order to return to the main menu.
2. Automatic Program Run
K*5<53D“FuncMode”.
K(B5CCENTER to confirm.
K*5<53D“AutoProg”.
K(B5CCENTER to confirm.
K*elect “Master” or “Alone”.
K(B5CCENTER to confirm.
K(B5CCMODE/ESC in order to return to the main menu.
20 WW PROFILE™ User Manual
Page 21
www.elationlighting.com
EditProg – RecCntrl – Working With Built-In Program [continued]
3. Program Selection for Automatic Program Run
K*5<53D“EditProg”.
K(B5CCENTER to confirm.
K*5<53D“Sel Progm ”.
K(B5CCENTER to confirm.
K*elect “ProPart 1”, “ProPart 2” or “ProPart 3”, and select which
Slave program is to be sent. Selection “Part 1” means, the Slave unit runs the
same program as the master units.
K(B5CC ENTER to confirm.
K(B5CCMODE/ESC in order to return to the main menu.
4. Program Selection for Edit Program
K*5<53DOEditProg”. K(B5CCENTER to confirm. K*5<53D“EditProg”. K(B5CCENTER to confirm.
K*elect the desired program to edit specific scenes into a specific program. K(B5CCENTER to confirm. K(B5CCMODE/ESC in order to return to the main menu.
5. Automatic Scene Recording
K*5<53D“EditProg”.
K(B5CCENTER to confirm.
K*5<53D“EditScen”.
K*5<53Ddesired scene numbers. A maximum of 250 scenes can be programmed.
K(B5CCENTER to confirm.
K(B5CCMODE/ESC in order to return to the main menu.
21 WW PROFILE™ User Manual
Page 22
www.elationlighting.com
EditProg – RecCntrl – Working With Built-In Program [continued]
Example:
Program 2 includes scenes: 10, 11, 12, & 13
Program 4 includes scenes: 8, 9, & 10
Program 6 includes scenes: 12, 13, 14, & 15
Auto Pro Part 1 is Program 2
Auto Pro Part 2 is Program 3
Auto Pro Part 3 is Program 6
The 3 Slave groups run the Auto Program in certain time segments, as shown in the following
picture:
22 WW PROFILE™ User Manual
Page 23
ELATION© WW PROFILE™
MODE /
CHANNEL
www.elationlighting.com
DMX CHANNEL FUNCTIONS AND VALUES
DMX Channel Values / Functions (4 DMX Channels)
Specifications are subject to change without any prior written notice.
VALUE FUNCTION
1CH 4CH
DIMMER
DIMMER FINE
STROBE
DIMMING CURVES
1 1
2
3
4
0-255 Intensity 0 to 100%
0-255 FINE Intensity 0 to 100%
0-31 LED OFF
32-63 LED ON
64-95 Strobe Effect SLOW to FAST
96-127 LED ON
128-159 Pulse Effect In Sequences
160-191 LED ON
192-223 Random Strobe Effect SLOW to FAST
224-255 LED ON
0-20 STANDARD
21-40 STAGE
41-60 TV
61-80 ARCHITECTURAL
81-100 THEATRE
101-255 Default to Unit Dimming Curve Setting
23 WW PROFILE™ User Manual
Page 24
www.elationlighting.com
CLEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.
Never use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three
months, to make sure the circuit contacts are in good condition and prevent
overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws
may fall out during normal operation resulting in damage or injury as larger parts
could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
24 WW PROFILE™ User Manual
Page 25
www.elationlighting.com
TECHNICAL SPECIFICATIONS
SOURCE 130W Warm White 3,000K LED Engine 50,000 Hour Average LED Life*
*May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
EFFECTS Electronic Strobe and Dimming Variable Dimming Curve Modes
GOBOS Supports “B” Size Metal, HT Transparency Gobos* *Gobos and Holder not included.
CONTROL / CONNECTIONS
2 DMX Channel Modes (1 / 4) Adjustable Refresh Rate (900-1500, 25,000 Hz) Adjustable Gamma Brightness (2.0, 2.2, 2.4, 2.8) 4 Button Control Panel / LED Menu Display 3/5pin DMX In/Out / powerCON In/Out
SIZE / WEIGHT
Length: 24.3” (618mm) Width: 12.2” (310mm) Vertical Height: 15.7” (398mm) Weight: 21.0 lbs. (9.5 kg)
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz 160W Max Power Consumption 14° to 113°F (-10° to 45°C)
APPROVALS / RATINGS
CE | cETLus | IP20
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
25 WW PROFILE™ User Manual
Page 26
PHOTOMETRIC DATA
www.elationlighting.com
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
26 WW PROFILE™ User Manual
Page 27
DIMENSIONAL DRAWINGS
www.elationlighting.com
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
OPTIONAL ACCESSORIES
ORDER CODE ITEM
TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp
PHD019 Profile High Definition Lens 19°
PHD126 Profile High Definition Lens 26°
PHD236 Profile High Definition Lens 36°
PHD350 Profile High Definition Lens 50°
PLC3 3' (1m) powerCON PRO Link Cable
AC3PDMX5PRO 5 ft. (1.5m) 3pin PRO DMX Cable
AC5PDMX5PRO 5 ft. (1.5m) 5pin PRO DMX Cable
Additional Cable Lengths Available
27 WW PROFILE™ User Manual
Page 28
Loading...