diagrams, images, and instructions herein are subject to change without notice. ELATION
PROFESSIONAL logo and identifying product names and numbers herein are trademarks
of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters
of copyrightable materials and information now allowed by statutory or judicial law or
hereinafter granted. Product names used in this document may be trademarks or
registered trademarks of their respective companies and are hereby acknowledged. All
non-ELATION brands and product names are trademarks or registered trademarks of their
respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages, injuries to any persons,
and direct or indirect economic loss associated with the use or reliance of any information
contained within this document, and/or as a result of the improper, unsafe, insufficient and
negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
Elation Professional Mexico| AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements,
an updated version of this document may be available
online. Please scan the QR Code with your mobile device or
visit www.elationlighting.com for the latest revision/update of
this manual, before installation and/or programming.
2
CONTENTS
General Information
4
Limited Warranty (USA Only)
5
Safety Guidelines
6
Maintenance Guidelines
8
Fixture Overview
9
Installation Guidelines
10
System Menu
14
Manual Dimming and Zoom Control
18
DMX Channel Functions And Values
19
Specifications
23
Optional Accessories
25
3
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before
attempting to operate this device. These instructions contain important safety and use
information.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating
condition. Carefully check the shipping carton for damage that may have occurred during
shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all
accessories necessary to install and operate the device have arrived intact. In the event
damage has been found or parts are missing, please contact our customer support team
for further instructions. Please do not return this device to your dealer without first
contacting customer support. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
Barn Door
Gel Frame
powerCON TRUE1 Cable
Fixture Safety Cable + Barn Door Safety Cable
CUSTOMER SUPPORT
Contact ELATION Service for any product related service and support needs.
Also visit forums.elationlighting.com with questions, comments or suggestions.
ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
323-582-3322 | Fax 323-832-9142 | support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
+31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu
REPLACEMENT PARTS please visit parts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR
MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO
THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND
GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE
NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
4
LIMITED WARRANTY (USA ONLY)
A. Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of
manufacturing defects in material and workmanship for a period of two years (730 days), and Elation
Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship
for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge
lamps and all product accessories. This warranty shall be valid only if the product is purchased within the
United States of America, including possessions and territories. It is the owner’s responsibility to establish the
date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send
the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested
repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will
pay return shipping charges only to a designated point within the United States. If any product is sent, it must
be shipped in its original package and packaging material. No accessories should be shipped with the product.
If any accessories are shipped with the product, Elation Professional shall have no liability what so ever for loss
and/or or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the product
serial number and/or labels are altered or removed; if the product is modified in any manner which Elation
Professional concludes, after inspection, affects the reliability of the product; if the product has been repaired or
serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to
purchaser by Elation Professional; if the product is damaged because not properly maintained as set forth in
the product instructions, guidelines and/or user manual. D. This is not a service contract, and this warranty
does not include any maintenance, cleaning or periodic check-up. During the periods as specified above,
Elation Professional will replace defective parts at its expense, and will absorb all expenses for warranty service
and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional
under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the
sole discretion of Elation Professional. All products covered by this warranty were manufactured after January
1, 1990, and bare identifying marks to that effect. E. Elation Professional reserves the right to make changes in
design and/or performance improvements upon its products without any obligation to include these changes in
any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with
respect to any accessory supplied with the products described above. Except to the extent prohibited by
applicable law, all implied warranties made by Elation Professional in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no
warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this
product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or
replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for
any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this
product. G. This warranty is the only written warranty applicable to Elation Professional products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre-paid and accompany a return
authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A
brief description of the problem as well as the R.A. number must also be written down on a piece of paper
and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of
purchase invoice. Items returned without a R.A. number clearly marked on the outside of the package will be
refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support.
5
SAFETY GUIDELINES
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID
YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM
MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF
SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID
THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY
WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
INDOOR / DRY LOCATIONS USE ONLY!
DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!
This fixture is a sophisticated piece of electronic equipment. To guarantee a smooth
operation, it is important to follow all instructions and guidelines in this manual. Elation
Professional is not responsible for injury and/or damages resulting from the misuse of this
fixture due to the disregard of the information printed in this manual. Only qualified and/or
certified personnel should perform installation of this fixture and only the original rigging
parts (omega brackets) included with this fixture should be used for installation. Any
modifications to the fixture and/or the included mounting hardware will void the original
manufactures warranty and increase the risk of damage and/or personal injury.
6
SAFETY GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow
approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the
power cord connectors are damaged and do not insert into the fixture securely with ease.
NEVER force a power cord connector into the fixture. If the power cord or any of its
connectors are damaged, replace it immediately with a new one of similar power rating.
DO NOT block any air ventilation slots.
All fan and air inlets must remain clean and never blocked.
Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
When installing fixture in a suspended environment, always use mounting hardware that is no
less than M10 x 25 mm, and always install fixture with an appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of service
and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the
plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the interior of
the fixture. This is a normal process and is caused by excess paint in the interior of the
casing burning off from the heat associated with the lamp and will decrease gradually over
time.
Consistent operational breaks will ensure fixture will function properly for many years.
ONLY use the original packaging and materials to transport the fixture in for service.
7
MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output, and
an extended life. The frequency of cleaning depends on the environment in which the
fixture operates: damp, smoky or particularly dirty environments can cause greater
accumulation of dirt on the fixture’s optics. Clean the external lens surface at least every 20
days with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service issues
to an authorized Elation service technician. Should you need any spare parts, please order
genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three months, to make
sure the circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out
during normal operation resulting in damage or injury as larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and rigging
points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to
enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture
to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or sediments.
NEVER remove the ground prong from the power cable.
A qualified electrician should be used for all electrical connections and/or installations.
USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE
POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX
POWER OUTPUT ON THIS FIXTURE. CHECK SILK SCREEN FOR MAX AMPS.
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical
and construction codes and regulations.
Before rigging/mounting a single fixture or multiple interconnected fixtures for custom
matrix designs to any metal truss/structure or placing the fixture(s) on any surface, a
professional equipment installer MUST be consulted to determine if the metal
truss/structure or surface is properly certified to safely hold the combined weight of the
fixture(s), clamps, cables, and accessories.
Fixture ambient operating temperature range is 14° to 113°F.(-10° to 45°C)
Do not use the fixture under or above this temperature.
Fixture(s) should be installed in areas outside walking paths, seating areas, or away from
areas were unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment,
such as an appropriately rated safety cable that meets all local, national, and country
codes and regulations. Allow approximately 15 minutes for the fixture to cool down before
serving.
10
GEL FRAME AND BARN DOOR INSTALLATION
The fixture has 2 slots on the front to hold the GEL FRAME and BARN DOOR. The first
smaller slot is for the GEL FRAME and the second larger slot is for the BARN DOOR.
The fixture also has a top lock that secures these accessories to the fixture.
Secure the included mini SAFETY CABLE to the BARN DOOR and the top lock.
1. Lift up lock on top of fixture and insert GEL FRAME into the first slot closest to fixture.
2. Insert BARN DOOR into the second slot.
3. Lower the lock on top of the fixture to secure both the GEL FRAME and BARN DOOR.
4. Secure the included mini SAFETY CABLE to the BARN DOOR and top lock.
11
CLAMP INSTALLATION
SAFETY CABLE
RIGGING POINT
This fixture includes an adjustable dual mounting yoke and safety cable rigging point
attached to the fixture (see the illustration below). When mounting this fixture to truss, be
sure to secure an appropriately rated clamp (not included) to the yoke using an M10 screw
and attach a SAFETY CABLE to the safety cable rigging point.
12
RIGGING
SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE
WHENEVER INSTALLING THIS FIXTURE IN
A SUSPENDED ENVIRONMENT TO
ENSURE THE FIXTURE WILL NOT DROP IF
THE CLAMP FAILS.
Overhead rigging requires extensive experience, including amongst others calculating
working load limits, installation material being used, and periodic safety inspection of all
installation material and the fixture. If you lack these qualifications, do not attempt the
installation yourself. Improper installation can result in bodily injury. Fixture is fully
operational in the specific mounting positions illustrated below.
13
SYSTEM MENU
The fixture includes an easy to navigate system menu. The control panel (see image below)
located on the side of the fixture provides access to the main system menu and is where all
necessary system adjustments are made to the fixture. During normal operation, pressing
MODE button once will access the fixture’s main menu. Once in the main menu you can
navigate through the different functions and access the sub-menus with the UP and
DOWN buttons. Once you reach a field that requires adjusting, press the ENTER button to
activate that field and use the UP and DOWN buttons to adjust the field. Pressing the
ENTER button once more will confirm your setting. You may exit the main menu at any
time without making any adjustments by pressing the MODE button.
NOTE: To access the LCD Menu Control Display when locked, press and hold the MODE
button for 3 seconds. The LCD Menu Control Display will shut OFF automatically about 1
minute from the last button press.
14
SYSTEM MENU - Supports Software Versions: ≥ 1.02
Features subject to change without notice.
MAIN MENU
SUB MENU
OPTIONS / VALUES (Default Settings in BOLD)
DESCRIPTION
Address
Address
001 ~ XXX
Set DMX Address Setting
UserMode
User Mode
2CH, 3CH,4CH, 6CH
Set DMX Channel / User Mode
Function
Status
Lost Dmx
Hold / Black
Function If NO DMX Detected
LCD. Set
Display
ON / OFF
OLED Display Screen Saver Mode
*When ON goes off after 30 seconds.
ONLY WHEN DMX IS CONNECTED.
STAGE 2 DIMMING CURVE MODE ADDED WITH SOFTWARE UPDATE VERSION ≥1.07
17
MANUAL DIMMING AND ZOOM CONTROL
MAIN MENU
SUB MENU
OPTIONS / VALUES (Default Settings in BOLD)
DESCRIPTION
Test
Reset.M
Zoom
Reset Zoom Motor
ManCtrl
Dimmer, Zoom, Strobe
Manual Control Functions
Calibrat
PassWord
Password=050
Calibrate Zoom Motor
(PSWD Required to Access)
Zoom
000-255
FEATURE IS DISABLED WHEN DMX INPUT CABLE IS CONNECTED TO FIXTURE!
TO USE DIMMING AND ZOOM KNOBS, DISCONNECT DMX CABLE IF CONNECTED.
Follow steps below to enable manual DIMMING and ZOOM control knobs.
1. Access fixture system menu navigating to Test menu then access ManCtrl sub menu.
NOTE: To access the LCD Menu Control Display when locked/OFF, press and hold the
MODE button for 3 seconds.
2. Select Stobe menu, set to value of 255 (LED ON), then exit fixture system menu.
3. Push DIMMING knob to unlock, rotate to desired level, push knob again to lock.
Repeat this process each time a dimmer adjustment is desired.
4. Push ZOOM knob to unlock, rotate to desired level, push knob in again to lock.
Repeat this process each time a dimmer adjustment is desired.
LCD DISPLAY
DMX CABLE CONNECTED NO DMX CABLE CONNECTED
18
DMX CHANNEL FUNCTIONS AND VALUES
ELATION KL FRESNEL 8
DMX Channel Values / Functions (6 DMX Channels)
Supports Software Versions: ≥ 1.02
Features subject to change without notice.
MODE / CHANNEL
VALUE
FUNCTION
2CH
3CH
4CH
6CH
1 1 1
1
DIMMER INTENSITY
000-255
Dimmer 0 to 100%
2
DIMMER INTENSITY FINE
000-255
Dimmer FINE Adjustment
2 2
3
SHUTTER, STROBE
000-031
LED OFF
032-063
LED ON
064-095
Strobe Effect SLOW to FAST
096-127
LED ON
128-159
Pulse Effect In Sequences
160-191
LED ON
192-223
Random Strobe Effect SLOW to FAST
224-255
LED ON
2 3 3
4
ZOOM
000-255
Zoom Adjustment from Min to Max
5
ZOOM FINE
000-255
Zoom FINE Adjustment
4
6
DIMMER MODES
000-020
Standard
021-040
Stage
041-060
TV
061-080
Architectural
081-100
Theatre
101-255
Default to Setting on Fixture
19
DMX CHANNEL UPDATE WITH SOFTWARE UPDATE VERSION≥1.07
See highlighted items below which have been updated with this software update.
MODE / CHANNEL
VALUE
FUNCTION
2CH
3CH
2-3CH
4CH
2-4CH
6CH
1 1 1 1 1
1
DIMMER INTENSITY
000-255
Dimmer 0 to 100%
2 2
2
DIMMER INTENSITY FINE
000-255
Dimmer FINE Adjustment
2 2
3
SHUTTER, STROBE
000-031
LED OFF
032-063
LED ON
064-095
Strobe Effect SLOW to FAST
096-127
LED ON
128-159
Pulse Effect In Sequences
160-191
LED ON
192-223
Random Strobe Effect SLOW to FAST
224-255
LED ON
2 3 3 3 3
4
ZOOM
000-255
Zoom Adjustment from Min to Max
5
ZOOM FINE
000-255
Zoom FINE Adjustment
4 4
6
DIMMER MODES
000-020
Standard
021-040
Stage
041-060
TV
061-080
Architectural
081-100
Theatre
101-120
Stage 2
121-255
Default to Setting on Fixture
20
DMX CHANNEL UPDATE WITH SOFTWARE UPDATE VERSION≥1.08
ELATION KL FRESNEL 8
DMX Channel Values / Functions (7 DMX Channels)
Supports Software Versions: ≥ 1.08
Features subject to change without notice.
MODE / CHANNEL
VALUE
FUNCTION
Dimmer
Dimmer
16bit
3CH
Standard
Extended
1 1 1 1 1
DIMMER INTENSITY
000-255
Dimmer 0 to 100%
2 2 2
DIMMER INTENSITY FINE
000-255
Dimmer FINE Adjustment
2 3 3
SHUTTER | STROBE
000-031
LED OFF
032-063
LED ON
064-095
Strobe Effect SLOW to FAST
096-127
LED ON
128-159
Pulse Effect In SLOW to FAST
160-191
LED ON
192-223
Random Strobe Effect SLOW to FAST
224-255
LED ON
2 3 3 4 4
MOTORIZED ZOOM
000-255
ZOOM Adjustment from SMALL to BIG
5 5
MOTORIZED ZOOM FINE
000-255
ZOOM FINE Adjustment
6 6
DIMMER MODES | DIMMER DELAY TIMES
000-020
Standard
021-040
Stage
041-060
TV
061-080
Architectural
081-100
Theatre
101-120
Stage 2
121
Dimmer Delay Time 0.0 seconds
122
Dimmer Delay Time 0.1 seconds
123
Dimmer Delay Time 0.2 seconds
124
Dimmer Delay Time 0.3 seconds
125
Dimmer Delay Time 0.4 seconds
126
Dimmer Delay Time 0.5 seconds
127
Dimmer Delay Time 0.6 seconds
128
Dimmer Delay Time 0.7 seconds
129
Dimmer Delay Time 0.8 seconds
130
Dimmer Delay Time 0.9 seconds
131
Dimmer Delay Time 1.0 seconds
132
Dimmer Delay Time 1.5 seconds
133
Dimmer Delay Time 2.0 seconds
134
Dimmer Delay Time 3.0 seconds
135
Dimmer Delay Time 4.0 seconds
136
Dimmer Delay Time 5.0 seconds
137
Dimmer Delay Time 6.0 seconds
138
Dimmer Delay Time 7.0 seconds
139
Dimmer Delay Time 8.0 seconds
140
Dimmer Delay Time 9.0 seconds
141
Dimmer Delay Time 10.0 seconds
142-255
Default
21
MODE / CHANNEL
VALUE
FUNCTION
Dimmer
Dimmer
16bit
3CH
Standard
Extended
7
LED REFRESH RATE | DIMMER CURVES** Hold selected DMX
value for 5 seconds to engage.
000-100
IDLE
101-105
900 Hz
106-110
1000 Hz
111-115
1100 Hz
116-120
1200 Hz
121-125
1300 Hz
126-130
1400 Hz
131-135
1500 Hz
136-140
2500 Hz
141-145
4000 Hz
146-150
5000 Hz
151-155
10,000 Hz
156-160
15,000 Hz
161-165
20,000 Hz
166-170
25,000 Hz
171-200
IDLE
201-210
DIMMER CURVE LINEAR (DEFAULT)
211-220
DIMMER CURVE SQUARE
221-230
DIMMER CURVE INVERSE SQUARE
231-240
DIMMER CURVE S-CURVE
241-255
IDLE
22
SPECIFICATIONS
SOURCE
350W 3,000K Warm White LED Engine
50,000 Hour Average LED Life*
*May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
EFFECTS
Manual and DMX Controlled Dimmer and Zoom
High Speed Electronic Shutter and Strobe
16-Bit Variable Dimming Curve Modes
COLOR
Warm
White (3,000K)
CONTROL / CONNECTIONS
Ma
nual and DMX Controlled Dimmer and Shutter
Dimmer and Zoom Rotary Dials
(5) DMX Channel Modes (2 / 3 / 3 / 6 / 7)
4 Button Control Panel LCD Menu Display
RDM (Remote Device Management)
Adjustable LED Refresh Rate
3/5pin DMX and powerCON TRUE1 In/Out
AC 100-240V - 50/60Hz
430W Max Power Consumption
14°F to 113°F (-10°C to 45°C)
APPROVALS / RATINGS
Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
23
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This device uses and
can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this device does cause harmful interference to radio or television reception, which can be
determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of
the following methods:
•!Reorient or relocate the device.
•!Increase the separation between the device and the receiver.
•!Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
•!Consult the dealer or an experienced radio/TV technician for help.
DIMENSIONAL DRAWINGS
Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
24
OPTIONAL ACCESSORIES
ORDER CODE
ITEM
QUICK RIG CLAMP
Low Profile Quick Release Clamp
AC3PDMX5PRO
5 ft. (1.5m) 3pin PRO DMX Cable
AC5PDMX5PRO
5 ft. (1.5m) 5pin PRO DMX Cable
NEU088
3 ft. (1m) powerCON TRUE1 Power Link Cable
Additional Cable Lengths Available
25
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.