Elation KL FRENSEL 4, KL FRESNEL 6 User Manual

Page 1
|
|
KL FRESNEL 4
KL FRENSEL 4
user manual
user manual
Page 2
©2017 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated
version of this document may be available online.
Please check Elation Service for the latest revision/update of this manual,
before beginning installation and/or programming.
Date
11/30/17 1 1.02 1 / 2 / 3 / 4 Initial release.
Document
Version
Software
Version
DMX
Channel Modes
Notes
www.elationlighting.com 2
Page 3
CONTENTS
General Information
4
Warranty
6
Safety Instructions and Guidelines
7
Overview
9
Installation
10
System Menu
14
DMX Channel Functions And Values
17
Cleaning and Maintenance
18
Technical Specifications
19
Optional Accessories
21
3 www.elationlighting.com
Page 4
GENERAL INFORMATION
INTRODUCTION
This fixture has been designed to perform reliably for years when the guidelines in this
manual are followed. Please read and understand the instructions in this manual
carefully and thoroughly before attempting to operate this unit. These instructions
contain important information regarding safety during use and maintenance.
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect operating
condition. Carefully check the shipping carton for damage that may have occurred
during shipping. If the carton appears to be damaged, carefully inspect your unit for
damage and be sure all accessories necessary to operate the unit have arrived intact. In
the event damage has been found or parts are missing, please contact our customer
support team for further instructions. Please do not return this unit to your dealer
without first contacting customer support at the number listed below. Please do not
discard the shipping carton in the trash. Please recycle whenever possible.
BOX CONTENTS
Barn Door
Gel Frame
powerCON TRUE1 Cable
Fixture Safety Cable
Barn Door Safety Cable
www.elationlighting.com 4
Page 5
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and to
answer any question should you encounter problems during your set up or initial
operation. You may also visit us on the web at www.elationlighting.com for any
comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre-paid and
accompany a return authorization (R.A.) number. The R.A. number must be clearly
written on the outside of the return package. A brief description of the problem as well
as the R.A. number must also be written down on a piece of paper and included in the
shipping container. If the unit is under warranty, you must provide a copy of your proof
of purchase invoice. Items returned without a R.A. number clearly marked on the
outside of the package will be refused and returned at customer’s expense. You may
obtain a R.A. number by contacting customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are not
subject to any warranty claims and/or repairs.
5 www.elationlighting.com
Page 6
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be
free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation
Professional® product rechargeable batteries to be free of manufacturing defects in material and
workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes
discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased
within the United States of America, including possessions and territories. It is the owner’s responsibility to
establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping charges
must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this
warranty, Elation Professional® will pay return shipping charges only to a designated point within the United
States. If any product is sent, it must be shipped in its original package and packaging material. No
accessories should be shipped with the product. If any accessories are shipped with the product, Elation
Professional® shall have no liability what so ever for loss and/or or damage to any such accessories, nor for
the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is
modified in any manner which Elation Professional® concludes, after inspection, affects the reliability of the
product; if the product has been repaired or serviced by anyone other than the Elation Professional® factory
unless prior written authorization was issued to purchaser by Elation Professional®; if the product is damaged
because not properly maintained as set forth in the product instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic
check-up. During the periods as specified above, Elation Professional® will replace defective parts at its
expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or
workmanship. The sole responsibility of Elation Professional® under this warranty shall be limited to the
repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional®.
All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to
that effect.
E. Elation Professional® reserves the right to make changes in design and/or performance improvements
upon its products without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with
the products described above. Except to the extent prohibited by applicable law, all implied warranties made
by Elation Professional® in connection with this product, including warranties of merchantability or fitness,
are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or
implied, including warranties of merchantability or fitness, shall apply to this product after said periods have
expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly
provided above; and under no circumstances shall Elation Professional® be liable for any loss and/or damage,
direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes
all prior warranties and written descriptions of warranty terms and conditions heretofore published.
www.elationlighting.com 6
Page 7
SAFETY INSTRUCTIONS AND GUIDELINES
This fixture is an extremely sophisticated piece of electronic equipment. To guarantee a
smooth operation, it is important to follow all instructions and guidelines in this manual. The
manufacturer of this device is not responsible for injury and/or damages resulting from the
misuse of this fixture due to the disregard of the information printed in this manual. Only
qualified and/or certified personnel should perform installation of this fixture and only the
original rigging parts (omega brackets) included with this fixture should be used for
installation. Any modifications to the fixture and/or the mounting hardware included will
void the original manufactures warranty and increase the risk of damage and/or personal
injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
INDOOR / DRY LOCATIONS USE ONLY!
DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!
LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
7 www.elationlighting.com
Page 8
SAFETY INSTRUCTIONS AND GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow
approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped and/or damaged.
If power cord is damaged, replace it immediately with a new one of similar power rating.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and
never blocked. Allow approx. 6” (15cm) between fixture and other devices or a wall for
proper cooling.
When installing fixture in a suspended environment, always use mounting hardware that
is no less than M10 x 25 mm, and always install fixture with an appropriately rated
safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug end, never
pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
Consistent operational breaks will ensure fixture will function properly for many years.
ONLY use the original packaging and materials to transport fixture in for service.
The average LED Life (hours) may vary depending on several factors including but not
limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling),
Control and Dimming.
www.elationlighting.com 8
Page 9
OVERVIEW
13. Manual Zoom Control Knob
1. powerCON TRUE1 Out
2. powerCON TRUE1 In
3. 5pin DMX In
4. 5pin DMX Out
5. USB Software Update Port
6. OLED Control Menu Display
7. MODE Button
INSTALLATION
8. UP Button
9. DOWN Button
10. ENTER Button
11. Manual Dimming Control Knob
12. Fuse
9 www.elationlighting.com
Page 10
INSTALLATION
t (1.5m) away from any
flammable materials, decorations, pyrotechnics, etc.
A qualified electrician should be used for all electrical connections and/or installations.
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 fee
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical
and construction codes and regulations.
Before rigging/mounting the fixture to any metal truss/structure or placing the fixture on any
surface, a professional equipment installer MUST be consulted to determine if the metal
truss/structure or surface is properly certified to safely hold the combined weight of the
fixture, clamps, cables, and accessories.
ELECTRICAL CONNECTIONS
Fixture ambient operating temperature range is 14° to 113°F. (-10° to 45°C)
Do not use the fixture under or above this temperature.
Fixture should be installed in areas outside walking paths, seating areas, or away from
areas were unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture when rigging, removing or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment,
such as an appropriately rated safety cable that can hold 10 times the weight of the fixture.
Allow approximately 15 minutes for the fixture to cool down before serving.
POWER LINKING
Max number of fixtures power linked together: 13 units @120V | 23 units @240V
USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO KL FRESNEL 4 AS
THE POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
www.elationlighting.com 10
Page 11
GEL FRAME AND BARN DOOR INSTALLATION
The fixture has 2 slots on the front to hold the GEL FRAME and BARN DOOR. The first slot
is for the GEL FRAME and the second slot is for the BARN DOOR. The fixture also has a
top lock that secures these accessories to the fixture.
Secure the included mini SAFETY CABLE to the BARN DOOR and the top lock.
1. Lift up lock on top of fixture and insert GEL FRAME into the first slot closest to fixture.
2. Insert BARN DOOR into the second slot.
3. Lower the lock on top of the fixture to secure both the GEL FRAME and BARN DOOR.
4. Secure the included mini SAFETY CABLE to the BARN DOOR and top lock.
11 www.elationlighting.com
Page 12
CLAMP INSTALLATION
When mounting the fixture to truss, be sure to secure an appropriately rated professional
grade rigging clamp to the fixture using an M10 screw fitted through one of the 3 holes of
the yoke bracket. The fixture provides a built-in rigging point for a SAFETY CABLE. Be
sure to only use the designated rigging point for the safety cable and never secure a safety
cable to a carrying handle.
SAFETY CABLE
RIGGING POINT
www.elationlighting.com 12
Page 13
RIGGING
Overhead rigging requires extensive experience, including amongst others calculating
working load limits, installation material being used, and periodic safety inspection of all
installation material and the fixture. If you lack these qualifications, do not attempt the
installation yourself. Improper installation can result in bodily injury. Fixture is fully
operational in the specific mounting positions illustrated below.
SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE
WHENEVER INSTALLING THIS FIXTURE
IN A SUSPENDED ENVIRONMENT TO
ENSURE THE FIXTURE WILL NOT DROP
IF THE CLAMP FAILS.
13 www.elationlighting.com
Page 14
SYSTEM MENU
Update
The fixture includes an easy to navigate system menu. The control panel (see image below)
located on the side of the fixture provides access to the main system menu and is where all
necessary system adjustments are made to the fixture. During normal operation, pressing
MODE button once will access the fixture’s main menu. Once in the main menu you can
navigate through the different functions and access the sub-menus with the UP and DOWN
buttons. Once you reach a field that requires adjusting, press the ENTER button to activate
that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER
button once more will confirm your setting. You may exit the main menu at any time without
making any adjustments by pressing the MODE button.
NOTE: To access the LCD Menu Control Display when locked, press and hold the MODE
button for 3 seconds. The LCD Menu Control Display will shut OFF automatically about 1
minute from the last button press.
INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:
www.elationlighting.com 14
Wait...
KLF4
Page 15
ELATION© KL FRESNEL 4™
S Y S T E M M E N U
Features are subject to change without any prior written notice.
Supports Software Versions: 1.02
MAIN MENU
SUB MENU
OPTIONS / VALUES (Default Settings in BOLD)
DESCRIPTION
Address
Address
001 ~ XXX
Set DMX Address Setting
UserMode
Lost Dmx
Hold / Black
Function If NO DMX Detected
OLED Display Screen Saver Mode
ONLY WHEN DMX IS CONNECTED.
Key Lock
ON / OFF
Control Front Panel Buttons Key Lock
Flash
ON / OFF
Display flashes when NO DMX
Invert
OFF / ON
Flip LCD Display 180º
Temp. C/F
F / C
+7?B7D3FGD7*I;F5:7FI77@VV
Dim Curve
Standard, Stage, TV, Architec, Theatre
Set Dimmer Curve Mode
Disp. Set
ADDR, Disp.CH, Salve
Set Information to Display on LCD
Fan. Set
Led Fan
Auto, High, Low
Set LED Fan Speed
Gamma
2.0, 2.2, 2.4, 2.8
Set Gamma Brightness
10Hz, 15Hz, 20Hz, 25Hz
Software Update Port - Contact Service
DFSE
OFF, ON
Restore Factory Settings
Current
000 (Hours)
Fixture Run Time From Power ON
Total
000 (Hours)
Fixture Total Run Time
Last
000 (Hours)
Clear Fixture Last Run Time
Password
PIN= 050
Enter PIN to Access Clear Last. Menu
Clear
ON / OFF
Reset Fixture Last Run Time
TempInfo
Led Temp
000 F (C)
Temperature of LED
Err. Info
Error Record 1 ~ Error Record 10
Display 10 Recent Error Messages
ModelInf
KLF4
Display Model Name
Software Version (Greater than or Equal to)
User Mode 1CH, 2CH, 3CH, 4CH Set DMX Channel / User Mode
Function
Info
Status
LCD. Set
Frequen
USB_Update
TimeInfo
Display
900Hz, 1000Hz, 1100Hz, 1200Hz, 1300Hz, 1400Hz, 1500Hz, 2500Hz, 4000Hz, 5000Hz,
OFF, ON
ON / OFF
*When ON goes off after 30 seconds.
Set LED Refreash Frequency
Software Software V1.02
Test
ManCtrl Dimmer, Strobe Test Functions
15 www.elationlighting.com
Page 16
DIMMER CURVE MODES - Dim Curve
Select desired DIMMER MODE (Standard, Stage, TV, Architectural, Theatre).
www.elationlighting.com 16
Page 17
DMX CHANNEL FUNCTIONS AND VALUES
ELATION KL FRESNEL 4™
DMX Channel Values / Functions (4 DMX Channels)
Supports Software Versions: 1.02
Features are subject to change without any prior written notice.
MODE / CHANNEL
1CH
2CH
3CH
4CH
DIMMER INTENSITY
000-255
Dimmer 0 to 100%
DIMMER INTENSITY FINE
000-255
Dimmer FINE Adjustment
SHUTTER, STROBE
000-031
LED OFF
032-063
LED ON
064-095
Strobe Effect SLOW to FAST
096-127
LED ON
128-159
Pulse Effect In Sequences
160-191
LED ON
192-223
Random Strobe Effect SLOW to FAST
224-255
LED ON
DIMMER MODES
000-020
Standard
201-040
Stage
041-060
TV
061-080
Architectural
081-100
Theatre
101-255
Default to Setting on Fixture
VALUE FUNCTION
1 1 1 1
2
2 2 3
3 4
17 www.elationlighting.com
Page 18
C LEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output, and
an extended life. The frequency of cleaning depends on the environment in which the
fixture operates: damp, smoky or particularly dirty environments can cause greater
accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation. NEVER use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service issues to
an authorized Elation service technician. Should you need any spare parts, please order
genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three months, to make
sure the circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners and accessories are securely tightened at all times. Lose
screws may fall out during normal operation resulting in damage or injury as parts could fall.
Check for any deformations on the housing, lenses, rigging hardware and rigging points
(ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter
into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to
fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or sediments.
Never remove the ground prong from the power cable.
www.elationlighting.com 18
Page 19
TECHNICAL SPECIFICATIONS
SOURCE
50W 3,000K Warm White LED Engine 50,000 Hour Average LED Life*
*May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
EFFECTS
Manual Dimmer and Zoom Control High Speed Electronic Shutter and Strobe 16-Bit Variable Dimming Curve Modes
COLOR
Cool White (3,000K)
CONTROL / CONNECTIONS
(4) DMX Channel Modes (1 / 2 / 3 / 4) 4 Button Touch Control Panel Manual Dimmer and Zoom Control Knobs Adjustable Refresh Rate Adjustable Gamma Brightness 180° Reversible LCD Menu Display DMX and RDM (Remote Device Management) Protocol Support 5pin DMX In/Out powerCON TRUE1 Power In/Out
SIZE / WEIGHT
Length: 13.6” (345mm) Width: 7.9” (201mm) Vertical Height: 11.4” (289mm) Weight: 9.0 lbs. (4.08 kg)
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz 50W Max Power Consumption 14°F to 113°F (-10°C to 45°C)
APPROVALS / RATINGS
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
19 www.elationlighting.com
Page 20
DIMENSIONAL DRAWINGS
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
www.elationlighting.com 20
Page 21
OPTIONAL ACCESSORIES
ORDER CODE ITEM
QUICK RIG CLAMP Low Profile Quick Release Clamp
AC5PDMX5PRO 5 ft. (1.5m) 5pin PRO DMX Cable
NEU088 3 ft. (1m) powerCON TRUE1 Power Link Cable
Additional Cable Lengths Available
21 www.elationlighting.com
Page 22