ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages, injuries to any
persons, and direct or indirect economic loss associated with the use or reliance of
any information contained within this document, and/or as a result of the improper,
unsafe, insufficient and negligent assembly, installation, rigging, and operation of
this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
Please check www.elationlighting.com for the latest revision/update of this manual.
DMX
Channel Modes
Notes
Updated max power
consumption and max number of
units for power linking specs.
Date
08/12/16
Document
Version
1.1
Software
Version
IU ≥1.03
2U ≥1.03
CH:04 RGBW / CH:04 HSI
CH:05 HSI+ / CH:06 RGBW
CH:07 sRGBWI / CH:07 RGBW
CH:08 RGBW / CH:09 RGBW
CH:10 16Bit / CH:10 HSI
2 FUZE PAR Z120 IP™ User Manual
Page 3
CONTENTS
General Information
4
Warranty
7
Safety Instructions and Guidelines
8
Overview
10
Installation
11
System Menu
15
DMX Channel Functions And Values
19
Cleaning and Maintenance
23
Technical Specifications
24
Optional Accessories
27
www.elationlighting.com
3 FUZE PAR Z120 IP™ User Manual
Page 4
www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable IP65 rated lighting fixtures on the market today! This fixture has been
designed to perform reliably for years when the guidelines in this booklet are
followed. Please read and understand the instructions in this manual carefully
and thoroughly before attempting to operate this unit. These instructions contain
important information regarding safety during use and maintenance.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor
environments and has been designed with an enclosure that effectively protects
the ingress (entry) of external foreign objects such as dust and water. The
International Protection (IP) rating system is commonly expressed as "IP" (Ingress
Protection) followed by two numbers (i.e. IP65) where the numbers define the
degree of protection. The first digit (Foreign Bodies Protection) indicates the
extent of protection against particles entering the fixture and the second digit
(Water Protection) indicates the extent of protection against water entering the
fixture. An IP65 rated lighting fixture is one, which has been designed and tested
to protect against the ingress of dust (6) and high-pressure water jets from any
direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS!
Please note although this fixture is IP rated, the fixture is NOTsuitable for marine
and/or coastal environment installations. Installing this fixture in a marine and/or
coastal environment may cause corrosion and/or excessive wear to the interior
and/or exterior components of the fixture. Damages and/or performance
issues resulting from installation in a marine and/or coastal environment will void
the manufactures warranty and will NOTbe subject to any warranty claims
and/or repairs.
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A
NON-CONDUCTIVE DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL
SUPPLIERS) TO PREVENT WATER INGRESS/CONDENSATION AND/OR CORROSION.
OPTIONAL CORROSION- RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture.
Please consult your Elation Professional sales representative for details.
4 FUZE PAR Z120 IP™ User Manual
Page 5
www.elationlighting.com
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are
missing, please contact our customer support team for further instructions. Please
do not return this unit to your dealer without first contacting customer support at
the number listed below. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
(1) Gel Frame
(1) Gel Frame/Barn Door Holder
(1) Barn Door
(1) powerCON TRUE1 Cable
CUSTOMER SUPPORT
Elation Professional®provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
5 FUZE PAR Z120 IP™ User Manual
Page 6
www.elationlighting.com
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid
and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the
problem as well as the R.A. number must also be written down on a piece of
paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a
R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting
customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
6 FUZE PAR Z120 IP™ User Manual
Page 7
www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to
be free of manufacturing defects in material and workmanship for a period of two years (730 days),
and Elation Professional® product rechargeable batteries to be free of manufacturing defects in
material and workmanship for a period of six months (180 days), from the original date of purchase.
This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only
if the product is purchased within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at
the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts replacement) are within
the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated
point within the United States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any accessories are
shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or
damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the
product is modified in any manner which Elation Professional® concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the
Elation Professional® factory unless prior written authorization was issued to purchaser by Elation
Professional®; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of Elation Professional® under
this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at
the sole discretion of Elation Professional®. All products covered by this warranty were manufactured
after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional® reserves the right to make changes in design and/or performance
improvements upon its products without any obligation to include these changes in any products
theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional® in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above.
And no warranties, whether expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole
remedy shall be such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
7 FUZE PAR Z120 IP™ User Manual
Page 8
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
This fixture is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow all instructions and guidelines
in this manual. The manufacturer of this device is not responsible for injury and/or
damages resulting from the misuse of this fixture due to the disregard of the
information printed in this manual. Only qualified and/or certified personnel should
perform installation of this fixture and only the original rigging parts (omega brackets)
included with this fixture should be used for installation. Any modifications to the
fixture and/or the mounting hardware included will void the original manufactures
warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED
WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL
SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL
SHORT CIRCUIT.
8 FUZE PAR Z120 IP™ User Manual
Page 9
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and
allow approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped and/or
damaged. If the power cord is damaged, replace it immediately with a new one
of similar power rating.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and
never blocked. Allow approx. 6” (15cm) between fixture and other devices or a
wall for proper cooling.
When installing fixture in a suspended environment, always use mounting
hardware that is no less than M10 x 25 mm, and always install fixture with an
appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug
end, never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
Consistent operational breaks will ensure the fixture will function properly for
many years to come.
Use the original packaging and materials to transport the fixture in for service.
9 FUZE PAR Z120 IP™ User Manual
Page 10
OVERVIEW
www.elationlighting.com
SAFETY CABLE RIGGING POINT
10 FUZE PAR Z120 IP™ User Manual
Page 11
INSTALLATION
Keep fixture at least 5.0 ft (1.5m) away from any
A qualified electrician should be used for all
www.elationlighting.com
FLAMMABLE MATERIAL WARNING
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
electrical connections and/or installations.
CAUTIONS
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A
DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT
WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 5° to 113°F. (-15° to 45°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
11 FUZE PAR Z120 IP™ User Manual
Page 12
www.elationlighting.com
CLAMP INSTALLATION
The fixture provides a integrated mounting dual bracket / yoke. When mounting this
fixture to truss be sure to secure an appropriately rated clamp to the mounting
bracket / yoke using a M10 screw fitted through the center hole. Be sure to attach
an appropriate Safety Cable (not included) to the fixture using the safety cable
rigging point integrated into the back of the fixture.
12 FUZE PAR Z120 IP™ User Manual
Page 13
www.elationlighting.com
RIGGING
Overhead rigging requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic safety
inspection of all installation material and the fixture. If you lack these qualifications,
do not attempt the installation yourself. Improper installation can result in bodily
injury. Fixture is fully operational in the specific mounting positions illustrated below.
SAFETY CABLE
ALWAYS USE A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED
ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS.
13 FUZE PAR Z120 IP™ User Manual
Page 14
POWER LINKING
Max number of FUZE WASH Z120 IP™ units power linked together:
6 units @120V | 12 units @240V
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO FUZE PAR Z120 IP™!
POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
ALWAYS CHECK MAX AMP OUT RATING PRINTED ON THE REAR CONNECTION PANEL!
www.elationlighting.com
14 FUZE PAR Z120 IP™ User Manual
Page 15
ZOOM
ELATION
Fuze Par
www.elationlighting.com
SYSTEM MENU
The fixture comes with an easy to navigate system menu. The control panel (see
image below) located on the front the fixture provides access to the main system
menu and is where all necessary system adjustments are made to the fixture. During
normal operation, pressing MODE button once will access the fixture’s main menu.
Once in the main menu you can navigate through the different functions and
access the sub-menus with the UP and DOWN buttons. Once you reach a field that
requires adjusting, press the ENTER button to activate that field and use the UP and
DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm
your setting. You may exit the main menu at any time without making any
adjustments by pressing the MODE/ESC button.
INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:
DMX Channel Values / Functions Version (13 DMX Channels)
Features are subject to change without any prior written notice.
www.elationlighting.com
Supports Software Versions: ≥ 1.03
MODE / CHANNEL
CH:04
RGBW
CH:04
5 5 6 6 7
6 7 7 8
4 4 6 7 7 8 8 9 6 8 9
10
7 9 10
8 10 11
9 11 12
5 9 10 12 13
HSI
CH:05
HSI
CH:06
RGBW
CH:07
sRGBWI
CH:07
RGBW
CH:08
RGBW
CH:09
RGBW
CH:10
16Bit
CH:10
HSI
CH:12
sRGBI
CH:13
RGBW
VALUE FUNCTION
0-255 Dimmer 0 to 100%
0-255 Dimmer FINE Adjustment
0-255
0-255 ZOOM FINE Adjustment
1-20 COLOR MACRO 01
21-40 COLOR MACRO 02
41-60 COLOR MACRO 03
61-80 COLOR MACRO 04
81-100 COLOR MACRO 05
101-120 COLOR MACRO 06
121-140 COLOR MACRO 07
141-160 COLOR MACRO 08
161-180 COLOR MACRO 09
181-200 COLOR MACRO 10
201-230 COLOR MACRO 11
231-240 COLOR MACRO 12
241-250 COLOR MACRO 13
251-255 GRADIENT COLOR MACRO
0-125
126-130 STOP
131-255
0-255 0-100%
0-20 STANDARD
21-40 STAGE
41-60 TV
61-80 ARCHITECTURAL
81-100 THEATRE
101-255 Default to Unit Setting
DIMMER INTENSITY
DIMMER INTENSITY FINE
ZOOM
ZOOM 0% (5 Degrees)
to 100% (50 Degrees)
ZOOM FINE
PROGRAM MACROS
0 NO FUNCTION
PROGRAM MACRO SPEED
Counter-Clockwise
Movement FAST to SLOW
Clockwise Movement
SLOW to FAST
PROGRAM MACRO FADE
DIMMING CURVE MODES
22 FUZE PAR Z120 IP™ User Manual
Page 23
www.elationlighting.com
CLEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.
Never use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three months,
to make sure the circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws may
fall out during normal operation resulting in damage or injury as larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
23 FUZE PAR Z120 IP™ User Manual
Page 24
www.elationlighting.com
TECHNICAL SPECIFICATIONS
SOURCE
120W RGBW COB LEDs
100,000 Hour Average Lamp Life*
*May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
COLOR
RGBW
EFFECTS
RGBW Color Mixing
7° - 55° Beam Zoom Range
Electronic Strobe, Dimming and Variable Dimming Curves
64 Color Presets and 14 Unique Color Macros
CONTROL / CONNECTIONS
12 DMX Channel Modes (13 Total Channels)
4 Touch Button Control Panel and LCD Menu Display
RDM (Remote Device Management)
IP rated 5pin DMX and powerCON TRUE1 In/Out