1. General Information……………………………………………………………………… 3 a. Introduction………………………………………………………………………. 3 b. Unpacking………………………………………………………..…………..… 3 c. Customer Support…………………………………………….………………… 3 d. Warranty Registration……………………………………………………..…… 4
2. Safety Instructions………………………………………………………........…………. 5
3. Features……………………………………………………………………………………7
4. General Guidelines………………………………………………………………………. 8
5. Fixture Overview…………………………………………………………………………. 9
6. Mounting and Installation………………………………………………………….……. 12
7. Understanding DMX……………………………………………………………………... 15 a. DMX Cables……..………………………………………………………………. 15 b. DMX Terminator…………………………………………………………………. 16 c. 3-Pin to 5-Pin Conversion………………………………………………………. 17 d. Fixture DMX Addressing.………………………..……………………………… 17
8. Display Indicators….……………………………………………………..……………… 19
9. Display Menu….……………………………………………………..…………………… 20
10. DMX Addressing…………………………………………………….…………………… 27 a. Remote DMX Addressing (RDMX)……………………………………………. 27
11. DMX Traits…………………………………………………………………………………29
12. Working with Built-In programs…………………………………………………………. 31
13. Lens Replacement………………………………………………………………….……. 34
14. Cleaning and Maintenance………………………………………………………………35
15. Warranty…………………………………………………………………………………... 36
16. Photometric Data………………………………………………………………………… 38
17. Dimensional Drawings………………………………………………….……………….. 39
18. Circuit Schematic………...………………………………………………………………. 40
19. Technical Specifications…………………………………………...………….………… 41
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 3 www.ElationLighting.com
1. GENERAL INFORMATION
INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The ELAR PAR 72 UV™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
UNPACKING: Thank you for purchasing the ELAR PAR 72 UV™ by Elation Professional®. Every ELAR PAR 72 UV™ has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for damage and be sure all accessories necessary to operate the fixture have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Inside the box you should find: the fixture, a DMX XLR cable, a safety cable, and this manual. Please do not return this unit to your dealer without first contacting customer support at the number listed below.
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issue please contact Elation Professional
®.
Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacific Standard Time. Voice: (323) 582-3322 Fax: (323) 832-9142 E-mail: support@elationlighting.com Forum: www.ElationLighting.com/forum
Warning! To prevent the risk of fire and reduce the risk electrical shock, do not attempt to operate this fixture with the lens cover removed.
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 4 www.ElationLighting.com
yourself. Doing so will void your manufactures warranty.
Please do not discard the shipping carton in the trash. Please recycle whenever possible.
WARRANTY REGISTRATION: The ELAR PAR 72 UV™ carries a two-year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without a R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support at (323) 582-3322.
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 5 www.ElationLighting.com
2. SAFETY INSTRUCTIONS
To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Elation Professional will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
1. Always be sure that the fan and the air inlets remain clean and are never blocked. Allow about 6” (15cm) between this fixture and other devices or a wall to allow for proper cooling. See page 12.
2. Never touch the fixture during normal operation.
3. Never look directly into the light source. You risk injury to your retina, which may induce blindness.
4. For safe operation, follow the I nstallation guide described in chapter six of this manual. Operating the ELAR PAR 72 UV™ without suited safety aids such as safety cables or clamps can increase the risk of damage and/or personal injury.
5. Qualified and certified personnel should only perform installation.
6. When mounting this fixture, use only the original rigging points included with this fixture. Any structural modification will void the original manufactures warranty and may increase the risk of damage and/or personal injury.
7. Do not attempt to operate this fixture if the power cord has become damaged or frayed.
8. Never open this fixture while in use.
9. This device falls under protection-class I. Therefore it is essential that the device be grounded properly.
10. Qualified personnel should perform all electrical connections.
11. Be sure the available voltage matches the voltage requirements of the unit. Be sure the power cord is never crimped or damaged. If the power cord is damaged, replace it immediately with a new one of similar power rating.
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 6 www.ElationLighting.com
12. Always disconnect from main power before performing any type of service or any cleaning procedure.
13. Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord.
14. Please safe keeping the waterproof socket packed in the attached bag. Cover the power cable and signal cable by the socket when the cable leave unused.
15. Please be aware that damages caused by modifications to the device are
not subject to warranty.
Important Notice: Damages resulting from the disregard of safety and general user
instructions found in this user manual are not subject to any warranty claims.
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 7 www.ElationLighting.com
3. FEATURES
• IP65 Rated Fixture
• Low power consumption
• Minimal heat emission
• Maintenance free operation
Equipped with 36 2-Watt UV led
Silent Operation, convection cooled, no fans
• 100,000 hours rated
LED life
• 20˚ Beam Angle/60˚ Field Angle (45˚ Lens)
• USITT DMX-512 Complaint
Preprogrammed colored macros
Strobe-effect with a maximum flash rate of 18fps
DMX-controlled operation or stand-alone operation with Master/Slave-function
Sound-controlled via built-in microphone
DMX Modes: 2 DMX channels
DMX-control via standard DMX-controller
Upgradable firmware via Elation “E-Loader” Data Pack
Electronic Switching Power Supply 100v~240v
Flicker-free operation for television and film
Compact design: fits in 12” box truss
• 0%~100% Dimming
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 8 www.ElationLighting.com
4. GENERAL GUIDELINES
This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, and other types of architectural installations. Do not attempt operation or installation without a proper knowledge on how to do so.
Consistent operational breaks will ensure that the fixture will function properly for many years to come.
Do not shake the fixture around. Avoid brute force when installing or operating the fixture.
While choosing an installation location, please be sure that the fixture will not be exposed to extreme heat, moisture, or dust. The minimum distance between the fixture and a wall or flat surface should be at least 0.5 meter (about 1.5ft). See page 12.
Always install the fixture with an appropriately rated safety cable. When installing the fixture in a suspended environment always be sure to use mounting hardware no less than M10 x 25 mm, also be sure the hardware is only inserted in the yoke’s mounting holes.
Do not attempt to operate this fixture until you have familiarized yourself with all of its functions.
Do not permit operation by persons not qualified for operating this type of architectural fixture. Most damages are the result of improper operation.
Please use the original packaging to transport the fixture in for service.
For your own safety, please read this user manual carefully before installing the device.
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 9 www.ElationLighting.com
5. FIXTURE OVERVIEW
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 10 www.ElationLighting.com
1. LED Lens Assembly – The lens assembly may be user replaced in the event repair is needed or a different beam angle is required.
2. LED Display – 4-segment menu display. Used to display the DMX address as well as all other menu functions.
3. Power Output Lead – This lead is used to jump power to another ELAR PAR 72 UV™. Please do not daisy chain power for more than 16 fixtures. To maintain the integrity of the IP rating, only use proper Elation IP rated power cables.
4. DMX Out Lead – This lead is used to send an incoming DMX signal to the next fixture in the DMX chain. To maintain the integrity of the IP rating, only use proper Elation IP rated DMX cables.
5. MENU Button – This button is used to access the fixtures menu functions.
6. Up Button – The up button is used to toggle forward through the menu functions and
settings.
7. Down Button – The down button is used to toggle backwards through the menu functions and settings.
8. Enter Button – The enter button is used to enter in to a certain menu function or to lock a menu setting in to memory.
9. Yoke Assembly – This yoke is designed to perform two functions; 1) When split it can be used as a floor stand bracket. 2) Used to secure a mounting clamp for truss mounting.
10. Main Power Input Lead – This lead is the main power input lead. When the unit is the first in a chain or the only fixture to be used, be sure to use the power starter
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 11 www.ElationLighting.com
cable that converts a standard Edison 3-prong to the IP rated twist lock connector. When jumping from fixture to fixture be sure to only use Elation IP rated power connectors to maintain the IP rating.
11. DMX In Lead – This lead is the main DMX input lead. When the unit is the first in a chain or the only fixture to be used with a DMX controller, be sure to use the DMX starter cable that converts a standard 3-pin XLR DMX connector to the IP rated twist lock connector that is used on the fixture. When jumping from fixture to fixture be sure to only use Elation IP rated DMX cables to maintain the IP rating.
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 12 www.ElationLighting.com
6. MOUNTING AND INSTALLATION
Cautions:
For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were unauthorized personnel might reach the fixture.
Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
To avoid injury, never stand directly below the device when mounting, removing, or servicing the fixture.
Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217 for proper installation in Europe To ensure proper installation, only qualified staff should attempt installation.
Mounting points
Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
CAUTION!
Be sure a qualified electrician performs all electrical
connections.
Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet.
ELAR PAR 72 UV
©Elation Professional, Los Angeles Ca. 13 www.ElationLighting.com
Mounting
The ELAR PAR 72 UV™ is fully operational in any mounting position, hanging upside-down, side mounted, or set on a flat level surface, etc. Be sure this fixture is kept at least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. See the image below.
Clamp Mounting The ELAR PAR 72 UV™ provides a unique mounting bracket assembly that allows the unit to stand on a flat surface or to be hung on truss via a clamp in any safe position (see the illustration above). Regardless of the mounting option you choose please be sure to refer to the safety guidelines in this manual to avoid damage to the unit and/or personal injury.