ELAR EXQUADPAR HP
ELAR EXQUADPAR HP Introduction
Unpacking: Thank you for purchasing the ELAR EXQUADPAR HP by
Elation Architectural®. Every ELAR EXQUADPAR HP has been thoroughly tested and has been shipped in perfect operating condition.
Carefully check the shipping carton for damage that may have occurred
during shipping. If the carton appears to be damaged, carefully inspect
your xture for any damage and be sure all accessories necessary to
operate the unit has arrived intact. In the case damage has been found
or parts are missing, please contact our customer support number for
further instructions. Do not return this unit to your dealer without rst
contacting customer support.
Introduction: The ELAR EXQUADPAR HP is part of Elation Archi-
tectural® continuing pursuit for creating high quality affordable intelli-
gent fixtures. The ELAR EXQUADPAR HP is a powerful DMX intelligent
RGBW LED par. This par is light weight and compact which makes it a
great piece for mobile DJ’s and clubs. The unit has 4 operating modes;
Auto Run mode, Program mode, RGB mode, and DMX Controlled. This
unit can be used as a stand alone unit or in a master-slave congura-
tion.
Customer Support: ©Elation® provides a customer support line, to
provide set up help and to answer any question should you encounter
problems during your set up or initial operation. You may also visit us
on the web at www.elationlighting.com for any comments or sugges-
tions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m.
Pacic Standard Time.
Voice: (323) 582-3322
Fax: (323) 832-9142
E-mail: support@elationlighting.com
8/12
User Instructions
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact
©Elation customer support.
PLEASE recycle the shipping carton when ever possible.
Elation Architectural - www.elationlighting.com - ELAR EXQUADPAR HP - Page 2
ELAR EXQUADPAR HP General Instructions
ELAR EXQUADPAR HP Safety Precautions
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations
of this unit. These instructions contain important safety information
regarding the use and maintenance of this unit. Please keep this manual
with the unit, for future reference.
ELAR EXQUADPAR HP Features
• Multi-Colors
• Quad LEDs - 4 LEDs Per Lens
• Built in Microphone
• DMX-512 protocol
• 8 DMX Modes: 1 Channel Mode, 2 Channel Mode, 3 Channel
Mode, 4 Channel Mode, 5 Channel Mode, 6 Channel Mode, 7
Channel Mode, & 8 Channel Mode
• Dimming 0-100% in 2 Channel Mode, 3 Channel Mode, 5 Channel
Mode, 6 Channel Mode, 7 Channel Mode, 8 Channel Mode.
• Daisy Chain Units Together in DMX Mode
• Daisy Chain Units Together via Power Cord
ELAR EXQUADPAR HP Warranty Registration
The ELAR EXQUADPAR HP carries a two year limited warranty.
Please fill out the enclosed warranty card to validate your purchase.
All returned service items whether under warranty or not, must be
freight pre-paid and accompany a return authorization (R.A.) number.
The R.A. number must be clearly written on the outside of the return
package. A brief description of the problem as well as the R.A. number
must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of
your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number.
All packages returned to the service department not displaying a R.A.
number on the outside of the package will be returned to the shipper.
• Be sure that the local power outlet match that of the required volt-
age for your unit.
• Do not attempt to operate this unit if the power cord has been
frayed or broken. Do not attempt to remove or break off the ground
prong from the electrical cord. This prong is used to reduce the risk
of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user
serviceable parts inside.
• Never open this unit, it is factory sealed for a reason.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper
ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by
t he manufacturer. See page 15 for cleaning details.
• Heat -The appliance should be situated away from heat sources
such as radiators, heat registers, stoves, or other appliances (inclu d ing amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the appliance.
C. The appliance does not appear to operate normally or exhibits a
marked change in performance.
Elation Architectural - www.elationlighting.com - ELAR EXQUADPAR HP - Page 4Elation Architectural - www.elationlighting.com - ELAR EXQUADPAR HP - Page 3
ELAR EXQUADPAR HP Set Up
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
and PIN 3 (DMX +) of the last fixture.
ELAR EXQUADPAR HP Set Up
Power Supply: The Elation ELAR EXQUADPAR HP contains a automatic voltage switch, which will auto sense the voltage when it is
plugged into the power source. With this switch there is no need to
worry about the correct power voltage, this unit can be plugged in
anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures
and controllers. A DMX controller sends DMX data instructions from
the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA
“OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of
different manufactures to be linked together and operate from a single
controller, as long as all xtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order
in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. When a fixture is assigned a DMX address
of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The ELAR EXQUADPAR HP can be controlled via DMX-512 protocol.
The ELAR EXQUADPAR HP has 8 DMX Modes. The DMX address is
set using the ELAR WR controller. Your unit and your DMX controller
require a approved DMX-512 110 Ohm Data cable for data input and
data output. We highly recommend the ELAR 3C-1M or ELAR 3C-5M
DMX Cables. These cables can be used in dry, damp, or wet areas in
indoor or outdoor enviroments. The rubber neoprene outer jacket is
weather and ozone resistant making the cables suitable for outdoor
use. This cable may be purchased at almost all professional sound and
lighting stores. Remember that DMX cable must be daisy chained and
cannot be split.
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin DMX-
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX
xtures may be implemented in a 3-pin DMX line. When inserting standard 5-pin data cables in to a 3-pin line a cable adaptor must be used,
these adaptors are readily available at most electric stores. The chart
below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
Elation Architectural - www.elationlighting.com - ELAR EXQUADPAR HP - Page 5