Elation Colour Pendant Users Manual

Page 1
|
|
COLOUR PENDANT™
user manual
COLOUR PENDANT
user manual
Page 2
6 RGBWI+ / 7 fXHSI / 8 fXHSI+ / 10RGBWI+
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
www.elationlighting.com
©2015 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
323-582-3322 | 323-832-9142 fax | TRIw.elationlighting.com | info@elationlighting.com
+31 45 546 85 66 | +31 45 546 85 96 fax | TRIw.elationlighting.eu | info@elationlighting.eu
DOCUMENT VERSION
Please check www.elationlighting.com for the latest revision/update of this manual.
Date
8/18/15 1
Document
Version
Software
Version
1.00
1 MACS / 3 HSI / 4 HSI+ / 4 RGBW
5 RGBWI / 5 sRGBW / 6 sRGBWI
DMX
Channel Modes
Notes
Initial release.
2 COLOUR PENDANT™ User Manual Ver. 1
Page 3
General Information
4
Warranty
6
Safety Instructions
7
General Guidelines
8
Fixture Overview
9
Fixture Installation
10
Fixture Menu
12
DMX Channel Functions And Values
15
Cleaning and Maintenance
17
Technical Specifications
18
Optional Accessories
20
CONTENTS
www.elationlighting.com
3 COLOUR PENDANT™ User Manual Ver. 1
Page 4
www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable lighting fixtures on the market today! The fixture has been designed to
perform reliably for years when the guidelines in this booklet are followed. Please
read and understand the instructions in this manual carefully and thoroughly
before attempting to operate this unit. These instructions contain important
information regarding safety during use and maintenance.
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to
operate the unit have arrived intact. In the event damage has been found or
parts are missing, please contact our customer support team for further
instructions. Please do not return this unit to your dealer without first contacting
customer support at the number listed below. Please do not discard the shipping
carton in the trash. Please recycle whenever possible.
BOX CONTENTS
(1) powerCON Cable
Manual & Warranty Card
4 COLOUR PENDANT™ User Manual Ver. 1
Page 5
www.elationlighting.com
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx All returned service items whether
under warranty or not, must be freight pre-paid and accompany a return
authorization (R.A.) number. The R.A. number must be clearly written on the
outside of the return package. A brief description of the problem as well as the
R.A. number must also be written down on a piece of paper and included in the
shipping container. If the unit is under warranty, you must provide a copy of your
proof of purchase invoice. Items returned without a R.A. number clearly marked
on the outside of the package will be refused and returned at customer’s
expense. You may obtain a R.A. number by contacting customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any
repairs yourself; doing so will void your manufactures warranty. Damages
resulting from modifications to this fixture and/or the disregard of safety and
general user instructions found in this user manual void the manufactures
warranty and are not subject to any warranty claims and/or repairs.
5 COLOUR PENDANT™ User Manual Ver. 1
Page 6
www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to
be free of manufacturing defects in material and workmanship for a period of two years (730 days),
and Elation Professional® product rechargeable batteries to be free of manufacturing defects in
material and workmanship for a period of six months (180 days), from the original date of purchase.
This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only
if the product is purchased within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at
the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts replacement) are within
the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated
point within the United States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any accessories are
shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or
damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the
product is modified in any manner which Elation Professional® concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the
Elation Professional® factory unless prior written authorization was issued to purchaser by Elation
Professional®; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of Elation Professional® under
this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at
the sole discretion of Elation Professional®. All products covered by this warranty were manufactured
after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional® reserves the right to make changes in design and/or performance
improvements upon its products without any obligation to include these changes in any products
theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional® in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above.
And no warranties, whether expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole
remedy shall be such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
6 COLOUR PENDANT™ User Manual Ver. 1
Page 7
n extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow the guidelines in this
manual. The manufacturer of this device will not accept responsibility for
fixture due to the disregard of the
. It’s essential this device be
perform all electrical
SAFETY INSTRUCTIONS
www.elationlighting.com
This fixture is a
damages resulting from the misuse of this
information printed in this manual.
This device falls under PROTECTION CLASS 1
grounded properly. Only qualified personnel should
connections.
INDOORS USE ONLY!
DO NOT EXPOSE FIXTURE RAIN AND MOISTURE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
For proper operation, follow the Installation guidelines described in this manual. Only qualified
and certified personnel should perform installation of this fixture and only the original rigging parts
(brackets) included with this fixture should be used for installation. Any modifications will void the
original manufactures warranty and increase the risk of damage and/or personal injury.
Never look directly into the light source of this fixture to prevent risk of injury to your retina, which
may induce blindness. Those suffering from EPILEPSY should avoid looking directly into the light
source of this unit at all times.
The fan and air inlets must remain clean and never blocked. Allow approx. 6” (15cm) between
this fixture and other devices or a wall for proper cooling.
Always disconnect from main power source before performing any type of service and/or
cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by
tugging the wire portion of the cord.
Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If
the power cord is damaged, replace it immediately with a new one of similar power rating.
7 COLOUR PENDANT™ User Manual Ver. 1
Page 8
www.elationlighting.com
GENERAL GUIDELINES
NEVER OPEN THIS FIXTURE WHILE IN USE!
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
This fixture is a professional lighting effect designed for INDOOR / DRY LOCATIONS
ONLY on stage, in nightclubs, theatres, etc.
Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while
operating, to prevent any fire hazard.
The fixture must be installed in a location with adequate ventilation, at least 1.5
feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked.
DO NOT attempt installation and/or operation without knowledge how to do so.
DO NOT permit operation by persons who are not qualified to operate this type
of fixture. Most damages are the result of operations by nonprofessionals.
Consistent operational breaks may ensure the fixture will function properly for
many years to come.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
Always install the fixture with an appropriate safety cable. When installing the
fixture in a suspended environment, always use mounting hardware that is no less
than M10 x 25 mm, also be sure the hardware is insert in the pre-arranged screw
holes in the bracket of the fixture.
Use the original packaging and materials to transport the fixture in for service.
DO NOT TOUCH the housing bare-hand during its operation. Turn OFF the power
and allow approximately 15 minutes for the fixture to cool down before replacing
or serving.
8 COLOUR PENDANT™ User Manual Ver. 1
Page 9
FIXTURE OVERVIEW
www.elationlighting.com
1. powerCON IN
2. 5pin DMX IN/OUT
3. E-FLY Wireless DMX Antenna
4. E-FLY Signal Indicator
5. MODE, UP, DOWN, ENTER Buttons
6. Safety Cable Attachment Point
7. LCD MENU Control Display
9 COLOUR PENDANT™ User Manual Ver. 1
Page 10
(1.5m) away from any
A qualified electrician should be used for all
FIXTURE INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft. flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
electrical connections and/or installations.
CAUTIONS
www.elationlighting.com
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 5°F to 113°F (-15°C to 45°C).
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
CLAMP MOUNTING
The fixture provides an integrated yoke/rigging bracket. When mounting this fixture
to truss be sure to secure an appropriately rated clamps to the yoke/rigging bracket
using a M10 screw fitted through the center hole.
10 COLOUR PENDANT™ User Manual Ver. 1
Page 11
www.elationlighting.com
MOUNTING POINTS
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic
safety inspection of all installation material and the device. If you lack these
qualifications, do not attempt the installation yourself. Improper installation can
result in bodily injury.
Fixture is fully operational in the specific mounting positions as illustrated below.
SAFETY CABLE
Always use a Safety Cable whenever installing this fixture in a suspended
environment to ensure the fixture will not drop if the clamp fails.
11 COLOUR PENDANT™ User Manual Ver. 1
Page 12
Update
RGBW
www.elationlighting.com
FIXTURE MENU
ON-BOARD SYSTEM MENU
The fixture comes with an easy to navigate system menu. The next section will detail
the functions of each command in the system menu.
LCD MENU CONTROL PANEL
The control panel (see image below) located on the top of the fixture allows you to
access the main menu and make all necessary adjustments to the fixture. During
normal operation, pressing MODE button once will access the fixture’s main menu.
Once in the main menu you can navigate through the different functions and
access the sub-menus with the UP, and DOWN buttons. Once you reach a field that
requires adjusting, press the ENTER button to activate that field and use the UP and
DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm
your setting. You may exit the main menu at any time without making any
adjustments by pressing the MODE button.
NOTE: the LCD Menu Control Display will shut OFF and lockout after 30 seconds of no
use. Press and hold the MODE button for 10 seconds to unlock the LCD display.
INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:
Fixture Software Version (Greater than or equal to)
12 COLOUR PENDANT™ User Manual Ver. 1
Wait...
V1.03
Page 13
ELATION© COLOUR PENDANT™
S Y S T E M M E N U
Specifications are subject to change without any prior written notice.
MENU
OPTIONS / VALUES
DESCRIPTION
CHANNEL
CH:1 MACS / 3 HSI / 4 HSI+ / 4 RGBW
5 RGBWI / 5 sRGBW / 6 sRGBWI
6 RGBWI+ / 7 fXHSI / 8 fXHSI+ / 10RGBWI+
www.elationlighting.com
Set desired DMX Channel Mode.
DMX MODE
ADDR:xxx
SLAVE
M O D E
Look
Store :xx
Frequenc
xxxxHz
Wireless
CH:xx
Reset?
Manual
ADDR:001 - 512 Set DMX Address.
Set unit to Slave Mode.
Store:01-23
1200Hz, 2400Hz, 4800Hz, 9600Hz Set Frequency to eliminate camera flicker and glare.
CH:01-15
No, Yes
R:000-255 G:000-255 B:000-255 W:000-255 S:000-255
Select Internal Program Macro. See INTERNAL MACRO MENU for more details.
Set E-FLY Wireless DMX Channel.
MUST BE SET TO SAME CHANNEL OF TRANSMITTER TO RECEIVE WIRELESS SIGNAL.
Reset fixture back to default settings: DMX MODE: 001 CHANNEL: 4 RGBW NO DMX: Hold Look Store: 01 Frequenc: 1200Hz
Set RGBW and Strobe Values manually.
DimCurve
NO DMX
13 COLOUR PENDANT™ User Manual Ver. 1
Standard, Stage, TV, Architec, Theatre Set desired Dimming Curve.
Hold, Blackout, Look Define how fixture reacts when NO DMX signal present.
Page 14
www.elationlighting.com
DIMMING CURVES
The DimCurve menu allows you to select one of the following preset dimming curves:
Standard, Stage, TV, Architectural, Theatre, or Default.
(See diagram below for more details)
Dimmer
14 COLOUR PENDANT™ User Manual Ver. 1
Page 15
ELATION© COLOUR PENDANT™
DMX Channel Values / Functions Version 1 (10 DMX Channels)
www.elationlighting.com
DMX CHANNEL FUNCTIONS AND VALUES
Specifications are subject to change without any prior written notice.
MODE / CHANNEL VALUE FUNCTION
1CH
MACS 3 HSI 4 HSI+ 4 RGBW 5 RGBWI
1
1 1 7
2 2 8
3 3 9
5
sRGBW 6 sRGBWi 6 RGBWI+ 7 fXHSI 8 fXHSI+
10
RGBWi+
COLOR MACROS
0 OFF
1-7 FULL Color Scroll (FAST Speed)
8-15 FULL Color Scroll (MEDIUM Speed)
16-25 FULL Color Scroll (SLOW Speed)
26-29 WARM Color Scroll (FAST Speed)
30-49 WARM Color Scroll (MEDIUM Speed)
40-50 WARM Color Scroll (SLOW Speed)
51-57 COOL Color Scroll (FAST Speed)
58-65 COOL Color Scroll (MEDIUM Speed)
66-73 COOL Color Scroll (SLOW Speed)
74-84 RED
85-91 PINK
92-99 ORANGE
100-109 LIGHT ORANGE
110-118 YELLOW
119-124 LIGHT YELLOW
125-132 GREEN
133-142 LIGHT GREEN
143-150 CYAN
151-158 LIGHT CYAN
159-165 BLUE
166-175 LIGHT BLUE
176-183 WARM WHITE
184-191 COOL WHITE
192-255 NO Function
COLOR SPEED
0 Static
1-255 Color Scroll SLOW to FAST
COLOR RANGE
0 FULL Spectrum
1-255
0-255
Variable Limit of Spectrum Color Scrolling
COLOR STEPS
Variable Control of Smoothness of Color Scrolling
15 COLOUR PENDANT™ User Manual Ver. 1
Page 16
ELATION© COLOUR PENDANT™
DMX Channel Values / Functions Version 1 (10 DMX Channels)
www.elationlighting.com
Specifications are subject to change without any prior written notice.
MODE / CHANNEL VALUE FUNCTION
1CH
MACS 3 HSI 4 HSI+ 4 RGBW 5 RGBWI
1 1 4 4 6
1 1 5 5
2 2 6 6
3 3 7 7
1 1 2 2 1 1
2 2 3 3 2 2
3 3 4 4 3 3
4 4 5 5 4 4
5 6 5 5
4 6 8 10
5
sRGBW 6 sRGBWi 6 RGBWI+ 7 fXHSI 8 fXHSI+
10
RGBWi+
FLASH / STROBE
0-31 OFF
32-95 Variable Strobe SLOW to FAST
96-127 Fade ON, Fade OFF SLOW to FAST
128-159 Fade ON, Snap OFF SLOW to FAST
160-191 Snap ON, Fade OFF SLOW to FAST
192-223 Random Strobe SLOW to FAST
224-255 ON
HUE
0-255 0-100%
SATURATION
0-255 0-100%
INTENSITY
0-255 0-100%
RED
0-255 0-100%
GREEN
0-255 0-100%
BLUE
0-255 0-100%
WHITE
0-255 0-100%
MASTER DIMMER
0-255 Intensity 0 to 100%
0-20 STANDARD
21-40 STAGE
41-60 TV
61-80 ARCHITECTURAL
81-100 THEATRE
101-255 Default to Unit Setting
DIMMING CURVE MODES
16 COLOUR PENDANT™ User Manual Ver. 1
Page 17
www.elationlighting.com
CLEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.
Never use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three
months, to make sure the circuit contacts are in good condition and prevent
overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws
may fall out during normal operation resulting in damage or injury as larger parts
could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
17 COLOUR PENDANT™ User Manual Ver. 1
Page 18
www.elationlighting.com
TECHNICAL SPECIFICATIONS
SOURCE (36) 3W RGBW LEDs 100,000 Hour Average Life
PHOTOMETRIC DATA 3,650 LUX 339 FC @3.3’ (1m) (41°Full ON) 1,020 LUX 95 FC @6.6’ (2m) (41°Full ON) 458 LUX 43 FC @9.8’ (3m) (41°Full ON) 255 LUX 24 FC @13.1’ (4m) (41°Full ON) 164 LUX 15 FC @16.4’ (5m) (41°Full ON)
EFFECTS Strobe and Color Macros Dimming : 0% - 100% Selectable Dimming Curves
CONTROL / CONNECTIONS
11 DMX Channel Modes (1 / 3 / 4x2 / 5x2 / 6x2 / 7 / 8 / 10) Frequencies (1200Hz, 2400Hz, 4800Hz, 9600Hz) 4 Button Control Panel and LCD Menu Display 5pin DMX In/Out RDM (Remote Device Management) powerCON Power In
SIZE / WEIGHT
Length: 14.7” (374 mm) Width: 9.9” (252.5 mm) Horizontal Height: 12.0” (308.8 mm) Weight: 14.0 lbs. (6.4 kg)
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz 110W Max Power Consumption
-14°F to 113°F (-10°C to 45°C)
APPROVALS / RATINGS
CE | | IP20
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
18 COLOUR PENDANT™ User Manual Ver. 1
Page 19
PHOTOMETRIC DATA
www.elationlighting.com
DIMENSIONAL DRAWINGS
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
19 COLOUR PENDANT™ User Manual Ver. 1
Page 20
www.elationlighting.com
OPTIONAL ACCESSORIES
ORDER CODE ITEM
TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp
EFL001 E-FLY Wireless DMX Transceiver
AC5PDMX5PRO 5 ft. (1.5m) 5pin PRO DMX Cable
Additional Cable Lengths Available
20 COLOUR PENDANT™ User Manual Ver. 1
Page 21
N OTES
www.elationlighting.com
21 COLOUR PENDANT™ User Manual Ver. 1
Page 22