ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages, injuries to any
persons, and direct or indirect economic loss associated with the use or reliance of
any information contained within this document, and/or as a result of the improper,
unsafe, insufficient and negligent assembly, installation, rigging, and operation of
this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
Please check www.elationlighting.com for the latest revision/update of this manual.
Date
10/19/17 1 1.02 16/18/78 Initial release.
Document
Version
Software
Version ≥
DMX
Channel
Modes
Notes
CHORUS LINE 16™ User Manual
www.elationlighting.com
3
General Information
4
Warranty
6
Safety Instructions and Guidelines
7
Overview
9
Installation
10
Fixture Menu
13
DMX Channel Functions And Values
16
Pixel Control
22
Cleaning and Maintenance
23
Technical Specifications
24
Optional Accessories
25
CONTENTS
CHORUS LINE 16™ User Manual
www.elationlighting.com
4
GENERAL INFORMATION
INTRODUCTION
This fixture has been designed to perform reliably for years when the guidelines in
this booklet are followed. Please read and understand the instructions in this
manual carefully and thoroughly before attempting to operate this unit. These
instructions contain important information regarding safety during use and
maintenance.
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are
missing, please contact our customer support team for further instructions. Please
do not return this unit to your dealer without first contacting customer support at
the number listed below. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
(2) Omega Brackets
(1) Safety Cable
(1) Power Cable
CHORUS LINE 16™ User Manual
www.elationlighting.com
5
CUSTOMER SUPPORT
Elation Professional®provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight
pre-paid and accompany a return authorization (R.A.) number. The R.A. number
must be clearly written on the outside of the return package. A brief description
of the problem as well as the R.A. number must also be written down on a piece
of paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a
R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting
customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
CHORUS LINE 16™ User Manual
www.elationlighting.com
6
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to
be free of manufacturing defects in material and workmanship for a period of two years (730 days),
and Elation Professional® product rechargeable batteries to be free of manufacturing defects in
material and workmanship for a period of six months (180 days), from the original date of purchase.
This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only
if the product is purchased within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at
the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts replacement) are within
the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated
point within the United States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any accessories are
shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or
damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the
product is modified in any manner which Elation Professional® concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the
Elation Professional® factory unless prior written authorization was issued to purchaser by Elation
Professional®; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of Elation Professional® under
this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at
the sole discretion of Elation Professional®. All products covered by this warranty were manufactured
after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional® reserves the right to make changes in design and/or performance
improvements upon its products without any obligation to include these changes in any products
theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional® in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above.
And no warranties, whether expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole
remedy shall be such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
CHORUS LINE 16™ User Manual
www.elationlighting.com
7
SAFETY INSTRUCTIONS AND GUIDELINES
This fixture is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow all instructions and guidelines
in this manual. The manufacturer of this device is not responsible for injury and/or
damages resulting from the misuse of this fixture due to the disregard of the
information printed in this manual. Only qualified and/or certified personnel should
perform installation of this fixture and only the original rigging parts (omega brackets)
included with this fixture should be used for installation. Any modifications to the
fixture and/or the mounting hardware included will void the original manufactures
warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
INDOOR / DRY LOCATIONS USE ONLY!
DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
CHORUS LINE 16™ User Manual
www.elationlighting.com
8
SAFETY INSTRUCTIONS AND GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and
allow approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped and/or
damaged. If the power cord is damaged, replace it immediately with a new one
of similar power rating.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and
never blocked. Allow approx. 6” (15cm) between fixture and other devices or a
wall for proper cooling.
When installing fixture in a suspended environment, always use mounting
hardware that is no less than M10 x 25 mm, and always install fixture with an
appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug
end, never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
Consistent operational breaks will ensure the fixture will function properly for
many years to come.
Use the original packaging and materials to transport the fixture in for service.
CHORUS LINE 16™ User Manual
www.elationlighting.com
9
OVERVIEW
1. LCD Menu Display, MENU, UP, DOWN, ENTER Buttons
2. Tilt Lock
3. Fuse
4. powerCON IN/OUT
5. 5pin DMX IN/OUT
6. RJ45 Ethernet IN/OUT
CHORUS LINE 16™ User Manual
www.elationlighting.com
10
t (1.5m) away from any
A qualified electrician should be used for all
INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 fee
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
electrical connections and/or installations.
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 5° to 113°F. (-15° to 45°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
POWER LINKING
Max number of CHORUS LINE 16 units power linked together:
1 unit @120V | 2 units @240V
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO CHORUS LINE 16!
POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
ALWAYS CHECK MAX AMP OUT RATING PRINTED ON THE REAR CONNECTION PANEL!
CHORUS LINE 16™ User Manual
www.elationlighting.com
11
ART-NET CONNECTION
When connecting fixture to a network switch to control multiple devices, a Gigabit
Ethernet Switch that supports IGMP (Internet Group Management Protocol) is required.
Using a Gigabit Ethernet Switch that does not support IGMP can cause erratic
Features are subject to change without any prior written notice.
MAIN MENU
SUB MENU
OPTIONS / VALUES
DESCRIPTION
Address
Address
001 ~ XXX
Fixture DMX Address Setting
UserMode
Standard, Basic, Extend
Set DMX Channel Mode
Lost Dmx
Close/Hold / Auto.Pro
Function If NO DMX Detected
Tilt Invert
ON / OFF
Tilt Reverse Movement
Feedback
ON/OFF
Movement Feedback
Move. Spd
Speed 1 ~ 4
Movement Mode Select
Stand By
OFF, 01M~99M, 15M
Stand By Mode
Fan. Set
Led Fan
Auto, High, LoW
Fan Speed Set
PassWord
XXX
Service PIN 050
DeviceIP
XXX.XXX.XXX.XXX.
Enter Fixture's IP Address
Universe
-255
Enter Universe Number
Protocol
ArtNet, KlingNet
Set Network Protocol
Net
/ OFF
Activate NET OUT Port.
Backligh
02~60m 05m
LCD Backlight Shut Off Time
FlipDisp
ON / OFF
Flip/Reverse LCD Display 180º
Control Front Panel Buttons Key
Lock
Flash
ON / OFF
Display flashes when NO DMX
-;CF;H7JKH;,M?J9>;JM;;D Z
Z
Dim Curve
Standard, Stage, TV, Architec, Theatre
Set Dimmer Curve Mode
ADDR
XXX
DMX Address Displayed
Value of each Channel
Displayed
Auto.Pro
Alone, Master
Set Auto Program Mode
Gamma
, 2.2, 2.4, 2.8
Set Gamma Brightness
DFSE
ON /
Restore Factory Settings
Current
XXXX (Hours)
Fixture Run Time From Power ON
Total
XXXX (Hours)
Fixture Total Run Time
Last
XXXX (Hours)
Fixture Last Run Time
Enter PIN to Access Clear Last.
Menu
Clear
ON / OFF
Reset Fixture Last Run Time
Temp. Info
LED Temp.
XXX F° / C°
Temperature in Fixture Head
Error Info
Error Record 1 ~ Error Record 10
Display 10 Recent Error Messages
Model. Info
Chorus 16
Display Model Name
1U01:
≥V1.02
2U01:
≥V1.02
3U01:
≥V1.02
4U01:
≥V1.02
5U01:
≥V1.02
Reset. M
Tilt, Zoom
Reset of Tilt and Zoom Motors
Test. Chan
Tilt ...
Test Functions
ManCtrl
Tilt=XXX
Manual Control
Calibrate
Password
Password= 050
Calibration of Motors and LEDs
Status
(Default Settings in BOLD)
Function
Net ID
ON
LCD. Set
Temp. C/F F/C
Disp. Set
Frequen
Time. Info
Key Lock ON / OFF
Disp.CH
Slave
2.0
900/1000/1100/1200/1300/1400/1500/2500
4000/5000/10K/15K/20K/25K
PassWord PIN= 050
NOTE: PassWord must be entered in order to set fixture IP Address and Universe
000
Slave 1, Slave 2, Slave 3
OFF
Set Slave Mode Preset
Set Refresh Rate Frequency
Info
Software
Version
Software Version
Test
CHORUS LINE 16™ User Manual
www.elationlighting.com
15
DIMMING CURVES
The DimCurve menu allows you to select one of the following preset dimming curves:
Standard, Stage, TV, Architec, or Theatre. (See diagram below for more details)
CHORUS LINE 16™ User Manual
www.elationlighting.com
16
Supports Software Versions: ≥ 1.02
MODE / CHANNEL
TILT MOVEMENT [8 BIT]
TILT MOVEMENT [16 BIT]
WHITE [ALL LEDs]
RED [PIXEL #1]
GREEN [PIXEL #1]
GREEN [PIXEL #2]
BLUE [PIXEL #2]
WHITE [PIXEL #2]
WHITE [PIXEL #3]
RED [PIXEL #4]
GREEN [PIXEL #4]
DMX CHANNEL FUNCTIONS AND VALUES
Features are subject to change without any prior written notice.
*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.
BASIC
CH: 16
1 1 1 0-255
2 2 0-255
2 3 0-255
3 4 0-255
4 5 0-255
5 6 0-255
3 0-255
4 0-255
5 0-255
6 0-255
7 0-255
STANDARD
CH: 18
EXTEND
CH: 78
VALUE FUNCTION
TILT Movement
Fine Control of TILT Movement
RED [ALL LEDs]
0 to 100%
GREEN [ALL LEDs]
0 to 100%
BLUE [ALL LEDs]
0 to 100%
0 to 100%
0 to 100%
0 to 100%
BLUE [PIXEL #1]
0 to 100%
WHITE [PIXEL #1]
0 to 100%
RED [PIXEL #2]
0 to 100%
8 0-255
9 0-255
10 0-255
11 0-255
12 0-255
13 0-255
14 0-255
15 0-255
16 0-255
17 0-255
18 0-255
0 to 100%
0 to 100%
0 to 100%
RED [PIXEL #3]
0 to 100%
GREEN [PIXEL #3]
0 to 100%
BLUE [PIXEL #3]
0 to 100%
0 to 100%
0 to 100%
0 to 100%
BLUE [PIXEL #4]
0 to 100%
WHITE [PIXEL #4]
0 to 100%
CHORUS LINE 16™ User Manual
www.elationlighting.com
17
Supports Software Versions: ≥ 1.02
0 to 100%
0 to 100%
0 to 100%
WHITE [PIXEL #5]
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
BLUE [PIXEL #7]
0 to 100%
WHITE [PIXEL #7]
0 to 100%
RED [PIXEL #8]
0 to 100%
GREEN [PIXEL #9]
0 to 100%
WHITE [PIXEL #10]
Features are subject to change without any prior written notice.
*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.
MODE / CHANNEL
BASIC
CH: 16
19 0-255
STANDARD
CH: 18
EXTEND
CH: 78
VALUE FUNCTION
RED [PIXEL #5]
20 0-255
21 0-255
22 0-255
23 0-255
24 0-255
25 0-255
26 0-255
27 0-255
28 0-255
29 0-255
30 0-255
31 0-255
32 0-255
33 0-255
34 0-255
35 0-255
GREEN [PIXEL #5]
BLUE [PIXEL #5]
RED [PIXEL #6]
GREEN [PIXEL #6]
BLUE [PIXEL #6]
WHITE [PIXEL #6]
RED [PIXEL #7]
GREEN [PIXEL #7]
GREEN [PIXEL #8]
0 to 100%
BLUE [PIXEL #8]
0 to 100%
WHITE [PIXEL #8]
0 to 100%
RED [PIXEL #9]
0 to 100%
36 0-255
37 0-255
38 0-255
39 0-255
40 0-255
41 0-255
42 0-255
0 to 100%
BLUE [PIXEL #9]
WHITE[ PIXEL #9]
0 to 100%
RED [PIXEL #10]
0 to 100%
GREEN [PIXEL #10]
0 to 100%
BLUE [PIXEL #10]
0 to 100%
0 to 100%
CHORUS LINE 16™ User Manual
www.elationlighting.com
18
Supports Software Versions: ≥ 1.02
BASIC
STANDARD
EXTEND
0 to 100%
0 to 100%
0 to 100%
WHITE [PIXEL #11]
0 to 100%
0 to 100%
0 to 100%
0 to 100%
WHITE [PIXEL #12]
0 to 100%
RED [PIXEL #13]
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
Features are subject to change without any prior written notice.
*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.
MODE / CHANNEL
CH: 16
43 0-255
CH: 18
CH: 78
VALUE FUNCTION
RED [PIXEL #11]
44 0-255
45 0-255
46 0-255
47 0-255
48 0-255
49 0-255
50 0-255
51 0-255
52 0-255
53 0-255
54 0-255
55 0-255
56 0-255
GREEN [PIXEL #11]
BLUE [PIXEL #11]
RED [PIXEL #12]
GREEN [PIXEL #12]
BLUE [PIXEL #12]
GREEN [PIXEL #13]
BLUE [PIXEL #13]
WHITE [PIXEL #13]
RED [PIXEL #14]
GREEN [PIXEL #14]
57 0-255
58 0-255
59 0-255
60 0-255
61 0-255
62 0-255
63 0-255
64 0-255
65 0-255
66 0-255
BLUE [PIXEL #14]
WHITE [PIXEL #14]
RED [PIXEL #15]
GREEN [PIXEL #15]
BLUE [PIXEL #15]
WHITE [PIXEL #15]
RED [PIXEL #16]
GREEN [PIXEL #16]
BLUE [PIXEL #16]
WHITE [PIXEL #16]
CHORUS LINE 16™ User Manual
www.elationlighting.com
19
Supports Software Versions: ≥ 1.02
8-255
2,700K -7,000K
0
OFF
5-8
COLOR PRESET 02
13-16
COLOR PRESET 04
21-24
COLOR PRESET 06
29-32
COLOR PRESET 08
37-40
COLOR PRESET 10
45-48
COLOR PRESET 12
53-56
COLOR PRESET 14
61-64
COLOR PRESET 16
69-72
COLOR PRESET 18
77-80
COLOR PRESET 20
85-88
COLOR PRESET 22
93-96
COLOR PRESET 24
101-104
COLOR PRESET 26
109-112
COLOR PRESET 28
117-120
COLOR PRESET 30
125-128
COLOR PRESET 32
Features are subject to change without any prior written notice.
*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.
MODE / CHANNEL
BASIC
CH: 16
7 67
STANDARD
CH: 18
EXTEND
CH: 78
VALUE FUNCTION
COLOR TEMP
COLOR PRESETS
1-4 COLOR PRESET 01
9-12 COLOR PRESET 03
17-20 COLOR PRESET 05
25-28 COLOR PRESET 07
33-36 COLOR PRESET 09
41-44 COLOR PRESET 11
49-52 COLOR PRESET 13
6 8 68
57-60 COLOR PRESET 15
65-68 COLOR PRESET 17
73-76 COLOR PRESET 19
81-84 COLOR PRESET 21
89-92 COLOR PRESET 23
97-100 COLOR PRESET 25
105-108 COLOR PRESET 27
113-116 COLOR PRESET 29
121-124 COLOR PRESET 31
CHORUS LINE 16™ User Manual
www.elationlighting.com
20
Supports Software Versions: ≥ 1.02
129-132
COLOR PRESET 33
137-140
COLOR PRESET 35
145-148
COLOR PRESET 37
153-156
COLOR PRESET 39
161-164
COLOR PRESET 41
169-172
COLOR PRESET 43
177-180
COLOR PRESET 45
185-188
COLOR PRESET 47
193-196
COLOR PRESET 49
201-204
COLOR PRESET 51
209-212
COLOR PRESET 53
217-220
COLOR PRESET 55
225-228
COLOR PRESET 57
233-236
COLOR PRESET 59
241-244
COLOR PRESET 61
249-252
COLOR PRESET 63
SHUTTER / STROBE
32-63
LED ON
96-127
LED ON
160-191
LED ON
224-255
LED ON
Features are subject to change without any prior written notice.
*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.
MODE / CHANNEL
BASIC
CH: 16
STANDARD
CH: 18
EXTEND
CH: 78
VALUE FUNCTION
COLOR PRESETS [continued]
133-136 COLOR PRESET 34
141-144 COLOR PRESET 36
149-152 COLOR PRESET 38
157-160 COLOR PRESET 40
165-168 COLOR PRESET 42
173-176 COLOR PRESET 44
6 8 68
7 9 69
181-184 COLOR PRESET 46
189-192 COLOR PRESET 48
197-200 COLOR PRESET 50
205-208 COLOR PRESET 52
213-216 COLOR PRESET 54
221-224 COLOR PRESET 56
229-232 COLOR PRESET 58
237-240 COLOR PRESET 60
245-248 COLOR PRESET 62
253-255 COLOR PRESET 64
0-31 LED OFF
64-95 Strobe Effect SLOW to FAST
128-159 Pulse Effect in Sequences
192-223 Random Strobe Effect SLOW to FAST
CHORUS LINE 16™ User Manual
www.elationlighting.com
21
Supports Software Versions: ≥ 1.02
Features are subject to change without any prior written notice.
BASIC
CH: 16
STANDARD
CH: 18
EXTEND
CH: 78
Dimmer 0 to 100%
DIMMER INTENSITY FINE
Dimmer FINE Adjustment
Zoom 0% (7 Degrees) to 100% (42 Degrees)
PROGRAM MACROS
Color Must Be Selected To Engage
Macros.
0
LEDs ON
1-14
LEDs OFF
15-30
PROGRAM MACRO 01
31-46
PROGRAM MACRO 02
47-62
PROGRAM MACRO 03
63-78
PROGRAM MACRO 04
79-94
PROGRAM MACRO 05
95-110
PROGRAM MACRO 06
111-126
PROGRAM MACRO 07
127-142
PROGRAM MACRO 08
143-158
PROGRAM MACRO 09
159-174
PROGRAM MACRO 10
175-190
PROGRAM MACRO 11
191-206
PROGRAM MACRO 12
207-222
PROGRAM MACRO 13
223-238
PROGRAM MACRO 14
239-255
PROGRAM MACRO 15
PROGRAM MACRO SPEED
SLOW to FAST Speed
1-255
LESS to MORE FADE
0-20
STANDARD
41-60
TV
81-100
THEATRE
101-255
Default to Unit Setting
0-225
MAX to MIN SPEED
226-235
Blackout By Movement
236-255
NO FUNCTION
0-79
Normal
80-84
ALL Motor Reset
85-99
NO FUNCTION
220-239
Internal Program 7 (scene49~56)
*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.
MODE / CHANNEL
VALUE FUNCTION
8 10 70 0-255
9 11 71 0-255
10 12 72 0-255
11 13 73
12 14 74 0-255
13 15 75
0 OFF
DIMMER INTENSITY
ZOOM
NOTE:
PROGRAM MACRO FADE
14 16 76
15 17 77
16 18 78
21-40 STAGE
61-80 ARCHITECTURAL
100-119 Internal Program 1 (scene1~8)
120-139 Internal Program 2 (scene9~16)
140-159 Internal Program 3 (scene17~24)
160-179 Internal Program 4 (scene25~32)
180-199 Internal Program 5 (scene33~40)
200-219 Internal Program 6 (scene41~48)
240-255 NO FUNCTION
DIMMING CURVE MODES
TILT MOVEMENT SPEED
LAMP ON/OFF, RESET, INTERNAL PROGRAMS
CHORUS LINE 16™ User Manual
www.elationlighting.com
22
PIXEL CONTROL
The fixture features pixel control in Extended DMX channel mode. See diagram
below, which illustrates the specific pixel mapping order.
CHORUS LINE 16™ User Manual
www.elationlighting.com
23
CLEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.
Never use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three months,
to make sure the circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws may
fall out during normal operation resulting in damage or injury as larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
CHORUS LINE 16™ User Manual
www.elationlighting.com
24
TECHNICAL SPECIFICATIONS
SOURCE
(16) 40W 4-in-1 RGBW LEDs
50,000 Hour Average LED Life*
*May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
EFFECTS
Motorized 4° to 40° Zoom and 220° Tilt
RGBW Color Mixing and Full Pixel Control
Linear Color Temperature (2,700K - 7,000K)
64 Color Presets and 14 Unique Color Macros
Electronic Strobe and Selectable Dimming Curve Modes
COLOR
RGBW
CONTROL / CONNECTIONS
3 DMX Channel Modes (78 total channels)
DMX, RDM, Kling-Net, and Art-Net Protocol Support
Adjustable Refresh Rate (900-25,000 Hz)
Adjustable Gamma Brightness (2.0, 2.2, 2.4, 2.8)
4 Button Touch Control Panel
180° Reversible LCD Menu Display
8 / 16-Bit Resolution Zoom and Tilt Movement
5pin DMX In/Out
RJ45 EtherCON In/Out
powerCON Power In/Out