Elation ARTISTE PICASSO User Manual

ARTISTE PICASSO
user manual
ARTISTE PICASSO™
user manual
©2018 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated
version of this document may be available online.
Please check www.elationlighting.com for the latest revision/update of this
manual, before beginning installation and/or programming.
Date
05/03/18 1 1.1.0 36 / 62 Initial release.
05/08/18 1.2 1.1.2 NO CHANGE Added Refresh Rate values to DMX control.
05/09/18 1.4 N/C NO CHANGE Added USB software update instructions.
Document
Version
Software
Version
DMX
Channel Modes
Notes
05/15/18 1.6 N/C NO CHANGE Updated max power consumption to 1000W.
www.elationlighting.com 2
CONTENTS
General Information
4
Limited Warranty
6
Safety Instructions and Guidelines
7
Overview
9
Colors and Gobos
10
Custom Gobos
11
Installation
12
System Menu
16
E-FLY Wireless DMX Set Up
25
E-FLY Wireless Installation Location Guidelines
26
DMX Channel Functions And Values
27
Error Codes
37
Cleaning and Maintenance
39
Technical Specifications
40
Optional Accessories
41
3
www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
This fixture has been designed to perform reliably for years when the guidelines in this
booklet are followed. Please read and understand the instructions in this manual carefully
and thoroughly before attempting to operate this unit. These instructions contain
important information regarding safety during use and maintenance.
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect operating
condition. Carefully check the shipping carton for damage that may have occurred during
shipping. If the carton appears to be damaged, carefully inspect your unit for damage
and be sure all accessories necessary to operate the unit have arrived intact. In the event
damage has been found or parts are missing, please contact our customer support team
for further instructions. Please do not return this unit to your dealer without first
contacting customer support at the number listed below. Please do not discard the
shipping carton in the trash. Please recycle whenever possible.
BOX CONTENTS
2 Omega Brackets
1 powerCON TRUE1 Cable
1 Safety Cable
www.elationlighting.com 4
CUSTOMER SUPPORT
Elation Professional provides a customer support line, to provide set up help and to
answer any question should you encounter problems during your set up or initial
operation. You may also visit us on the web at www.elationlighting.com for any
comments or suggestions. For service related issue please contact Elation Professional.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx to validate your purchase. All returned
service items whether under warranty or not, must be freight pre-paid and accompany a
return authorization (R.A.) number. The R.A. number must be clearly written on the
outside of the return package. A brief description of the problem as well as the R.A.
number must also be written down on a piece of paper and included in the shipping
container. If the unit is under warranty, you must provide a copy of your proof of purchase
invoice. Items returned without a R.A. number clearly marked on the outside of the
package will be refused and returned at customer’s expense. You may obtain a R.A.
number by contacting customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are not
subject to any warranty claims and/or repairs.
5
www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free
of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional® product rechargeable batteries to be free of manufacturing defects in material and workmanship
for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge
lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the
date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this
warranty, Elation Professional® will pay return shipping charges only to a designated point within the United
States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional®
shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return
thereof. C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is
modified in any manner which Elation Professional® concludes, after inspection, affects the reliability of the
product; if the product has been repaired or serviced by anyone other than the Elation Professional® factory unless prior written authorization was issued to purchaser by Elation Professional®; if the product is damaged
because not properly maintained as set forth in the product instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional® will replace defective parts at its
expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or
workmanship. The sole responsibility of Elation Professional® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional®.
All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to
that effect. E. Elation Professional® reserves the right to make changes in design and/or performance improvements
upon its products without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made
by Elation Professional® in connection with this product, including warranties of merchantability or fitness, are
limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired.
The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided
above; and under no circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes all
prior warranties and written descriptions of warranty terms and conditions heretofore published.
www.elationlighting.com 6
SAFETY INSTRUCTIONS AND GUIDELINES
INTENSITY WAVELENGTH OF ULTRAVIOLET UV
AVOID PROLONGED PERIODS OF EXPOSURE TO UV
OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE
ORDERS, OR
PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET UV LIGHT EMITTED FROM THE UV COLOR FITLER.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
This fixture is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. The manufacturer of this device is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts (omega brackets) included with this fixture should be used for installation. Any modifications to the fixture and/or the mounting hardware included will void the original manufactures warranty and increase the risk of damage and/or personal injury.
DO NOT PLUG FIXTURE INTO A DIMMER PACK! NEVER OPEN THIS FIXTURE WHILE IN USE! UNPLUG POWER BEFORE SERVICING FIXTURE! NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
INDOOR / DRY LOCATIONS USE ONLY! DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS!
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET UV RADIATION! FIXTURE EMITS HIGH LIGHT FROM THE UV COLOR FILTER. WEAR PROPER EYE AND SKIN PROTECTION. COLOR FILTER. AVOID WEARING WHITE COLOR CLOTHING AND/OR USING UV PAINTS ON SKIN. AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES LESS THAN 11 feet (3.3m). DO NOT OPERATE FIXTURE WITH DAMAGED/MISSING EXTERNAL COVERS. DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND/OR VIEW UV LIGHT DIRECTLY WITH
LIGHT/RADIATION OUTPUT. INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DIS­INDIVIDUALS USING
7
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow
approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped, damaged and/or if
any of the power cord connectors are damaged and do not insert into the fixture securely
with ease. NEVER force a power cord connector into the fixture. If the power cord or any of
its connectors are damaged, replace it immediately with a new one of similar power rating.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and never
blocked. Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
When installing fixture in a suspended environment, always use mounting hardware that is
no less than M10 x 25 mm, and always install fixture with an appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of service
and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the
plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the interior
of the fixture. This is a normal process and is caused by excess paint in the interior of the
casing burning off from the heat associated with the lamp and will decrease gradually over time.
Consistent operational breaks will ensure the fixture will function properly for many years to come.
ONLY use the original packaging and materials to transport fixture in for service.
www.elationlighting.com 8
O VERVIEW
1. LED Lens Array
2. Wireless Indicator
3. LCD Control Menu Display
4. MODE/ESC Button
5. LEFT Button
6. DOWN Button
7. ENTER Button
8. RIGHT Button
9. UP Button
10. PAN Lock
11. Handel (s)
12. TILT Lock
13. RJ45 etherCON IN
14. RJ45 etherCON OUT
15. 5pin DMX IN
16. 5pin DMX OUT
17. Fuse
18. powerCON TRUE1 IN
9
19. Service Port
www.elationlighting.com
COLORS AND GOBOS
www.elationlighting.com 10
CUSTOM GOBOS
* * * IMPORTANT NOTICE REGARDING CUSTOM GOBOS * * *
Due to the high temperature optical system, special material as listed above is
required for custom gobos. Due to varying manufacturing processes and tolerances,
it is highly recommended to provide a gobo sample and holder from the fixture to the
custom gobo vendor for accurate sizing. Extended testing of custom gobo designs is
highly recommended prior to use. Contact ELATION SERVICE for further information.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
11
www.elationlighting.com
INSTALLATION
Keep fixture at least 5.0 feet (1.5m) away from any
A qualified electrician should be used for all
FLAMMABLE MATERIAL WARNING
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
electrical connections and/or installations.
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and
construction codes and regulations.
Before rigging/mounting the fixture to any metal truss/structure or placing the fixture on any
surface, a professional equipment installer MUST be consulted to determine if the metal
truss/structure or surface is properly certified to safely hold the combined weight of the
fixture, clamps, cables, and accessories.
Fixture ambient operating temperature range is 14° to 113°F. (-10° to 45°C)
Do not use the fixture under or above this temperature.
Fixture should be installed in areas outside walking paths, seating areas, or away from areas
were unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture when rigging, removing or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment,
such as an appropriately rated safety cable.
Allow approximately 15 minutes for the fixture to cool down before serving.
www.elationlighting.com 12
OMEGA BRACKETS INSTALLATION
Insert the Omega Brackets into the matching holes on the bottom of the fixture. Secure the
Omega Brackets to the fixture by turning each quick-lock fastener ¼ turn clockwise; making
sure the fastener is completely locked.
SAFETY CABLE
RIGGING POINT
CLAMP INSTALLATION
When mounting fixture to truss, be sure to secure an appropriately rated professional grade
rigging clamp to the included Omega Brackets using an M10 screw fitted through the
center hole of the Omega Brackets. The fixture provides a built-in rigging point for a
SAFETY CABLE. Be sure to only use the designated rigging point for the safety cable and
never secure a safety cable to a carrying handle.
13
www.elationlighting.com
Loading...
+ 29 hidden pages