Elation Arena Zoom Q7IP Users Manual

|
|
ARENA ZOOM Q7IP™
user manual
ARENA ZOOM Q7IP
user manual
©2017 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated
version of this document may be available online.
Please check www.elationlighting.com for the latest revision/update of
this manual, before beginning installation and/or programming.
Date
10/18/17 1
Document
Version
Software
Version
App: 1.1
6 / 7 / 8 / 9 / 11 / 12 Initial release.
Boot: 1.0
DMX
Channel Modes
Notes
www.elationlighting.com 2
CONTENTS
General Information
4
Warranty
7
Safety Instructions and Guidelines
8
Overview
10
Installation
11
System Menu
14
DMX Channel Functions And Values
17
Cleaning and Maintenance
19
Technical Specifications
20
Optional Accessories
21
3
www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable IP65 rated lighting fixtures on the market today! This fixture has been
designed to perform reliably for years when the guidelines in this booklet are
followed. Please read and understand the instructions in this manual carefully
and thoroughly before attempting to operate this unit. These instructions contain
important information regarding safety during use and maintenance.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as "IP" (Ingress Protection) followed by two numbers (i.e. IP65) where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture and the second digit (Water Protection) indicates the extent of protection against water entering the fixture. An IP65 rated lighting fixture is one, which has been designed and tested to protect against the ingress of dust (6) and high-pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS!
Please note although this fixture is IP rated, the fixture is NOT suitable for marine and/or coastal environment installations. Installing this fixture in a marine and/or coastal environment may cause corrosion and/or excessive wear to the interior and/or exterior components of the fixture. Damages and/or performance issues resulting from installation in a marine and/or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and/or repairs.
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A
NON-CONDUCTIVE DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL
SUPPLIERS) TO PREVENT WATER INGRESS/CONDENSATION AND/OR CORROSION.
OPTIONAL CORROSION- RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture. Please consult your Elation Professional sales representative for details.
www.elationlighting.com 4
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are
missing, please contact our customer support team for further instructions. Please
do not return this unit to your dealer without first contacting customer support at
the number listed below. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
powerCON TRUE1 Cable
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
5
www.elationlighting.com
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid
and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the
problem as well as the R.A. number must also be written down on a piece of
paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a
R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting
customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
www.elationlighting.com 6
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional® product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professional® factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional® concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional® factory unless prior written authorization was issued to purchaser by Elation Professional®; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual. D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional® will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional®. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect. E. Elation Professional® reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional® in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
7
www.elationlighting.com
SAFETY INSTRUCTIONS AND GUIDELINES
This fixture is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow all instructions and guidelines
in this manual. The manufacturer of this device is not responsible for injury and/or
damages resulting from the misuse of this fixture due to the disregard of the
information printed in this manual. Only qualified and/or certified personnel should
perform installation of this fixture and only the original rigging parts (omega brackets)
included with this fixture should be used for installation. Any modifications to the
fixture and/or the mounting hardware included will void the original manufactures
warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED!
DO NOT CONNECT GOBO ROTATOR CABLE TO FIXTURE
WHEN FIXTURE IS POWERED ON!
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK - MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED
WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL
SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL
SHORT CIRCUIT.
www.elationlighting.com 8
SAFETY INSTRUCTIONS AND GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and
allow approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped and/or
damaged. If the power cord is damaged, replace it immediately with a new one
of similar power rating.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and
never blocked. Allow approx. 6” (15cm) between fixture and other devices or a
wall for proper cooling.
When installing fixture in a suspended environment, always use mounting
hardware that is no less than M10 x 25 mm, and always install fixture with an
appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug
end, never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
Consistent operational breaks will ensure the fixture will function properly for
many years to come.
Use the original packaging and materials to transport the fixture in for service.
The average LED Life (hours) may vary depending on several factors including
but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns
(On-Off Cycling), Control and Dimming.
9
www.elationlighting.com
OVERVIEW
1. OLED Menu Control Display
2. Menu/Up/Down/Enter Buttons
3. IP Rated 5pin DMX IN
4. IP Rated 5pin DMX OUT
5. powerCON TRUE1 IN
6. powerCON TRUE 1 OUT
www.elationlighting.com 10
INSTALLATION
t (1.5m) away from any
A qualified electrician should be used for all
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 fee flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
electrical connections and/or installations.
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 14° to 113°F. (-10° to 45°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
11
www.elationlighting.com
POWER LINKING
Max number of ARENA ZOOM Q7IP™ units power linked together:
6units @120V | 12 units @240V
NOTE: CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER
CONSUMPTION OF OTHER FIXTURES MAY EXCEED THE MAX OUTPUT ON THIS FIXTURE.
CLAMP MOUNTING
This fixture includes an adjustable mounting yoke and safety cable rigging point
attached to the fixture (see the illustration below). When mounting this fixture to truss,
be sure to secure an appropriately rated clamp (not included) to the yoke using an
M10 screw, and attach a SAFETY CABLE to the fixture safety cable rigging point.
SAFETY CABLE
RIGGING POINT
www.elationlighting.com 12
RIGGING
Overhead rigging requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic safety
inspection of all installation material and the fixture. If you lack these qualifications,
do not attempt the installation yourself. Improper installation can result in bodily
injury. Fixture is fully operational in the specific mounting positions illustrated below.
ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED
ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS.
13
SAFETY CABLE
www.elationlighting.com
SYSTEM MENU
The fixture includes an easy to navigate system menu. The OLED control panel
display (see image below) located on the back of the fixture, provides access to the
main system menu and is where all necessary system adjustments are made to the
fixture. During normal operation, pressing MENU button once will access the fixture’s
main menu. Once in the main menu you can navigate through the different
functions and access the sub-menus with the UP and DOWN buttons. Once you
reach a field that requires adjusting, press the ENTER button to activate that field
and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button
once more will confirm your setting. You may exit the main menu at any time
without making any adjustments by pressing the MENU button.
www.elationlighting.com 14
ELATION© ARENA ZOOM Q7IP - S Y S T E M M E N U
Supports Software Versions: App: ≥1.1 | Boot: ≥1.0
Features subject to change without any prior written notice.
MAIN MENU
DMX Setting
DMX Last State
Set Transition Time Between Scenes
Set Length of Time Scenes Are Displayed
Back Light Auto
Reset Function
SUB MENU OPTIONS / VALUES (Default Settings in BOLD) DESCRIPTION
DMX Address 001 - 512 Set DMX Address Setting
Channel Mode 6CH, 7CH, 8CH, 9CH, 11CH, 12CH Select DMX Channel Mode
Black Out, Hold, Master/Slave
Red - 0-255
Light Mode White Balance
Green - 0-255 Blue - 0-255
Define How Fixture Reacts When NO DMX Signal Is Present
Adjust White Balance of Each LED
Fixture Setting
Internal Program
Auto Test
Manual Mode
Gamma Correction
Constant Color Enable / Disable
Dimmer Curve
PWM Frequency
Fan Mode Auto Mode, Silent Mode Set Fan Mode
Total Scenes 1-50 (4)
Edit Scene Colors
Fade Time 0-255 secs (4)
Hold Time 0-255 secs (8)
Zoom 0-255 (0) Set Zoom 0 = Narrow | 255 = Wide
Dimmer 0-255
Strobe 0-255
Red 0-255
Green 0-255
White 0-255
Zoom 0-255
Invert Display No, Yes Flip OLED Control Display 180°
Disable, 2.0, 2.2, 2.4, 2.8 Set Gamma Brightness
Standard, Stage, TV, Architectural, Theatre Set Dimming Curve Mode
600hz, 1200hz, 2400hz, 3600hz, 4800hz, 6000hz, 10200hz, 15000hz, 20400hz, 25200hz, 28800hz
Red - 0-255
1- (x)
Green - 0-255 Blue - 0-255 White - 0-255
Testing......
Set LED Refresh Frequency Rate
Set Total Number of Scenes To Use Scenes 1-4 Set by Default: Scene 1 - Red =255 Scene 2 - Green = 255 Scene 3 - Blue = 255 Scene 4 - White = 255
Edit RGBW Values for Scenes. Edit Function ONLY Available for Scene Numbers Accessed in Total Scenes Menu
Run Auto Test of Fixture
Manual Control of Fixture
Display Setting
Fixture Information
Factory Restore
Off Unit Temperature / C° (3;>3@/BC@3'E7B163BE33<LL
Display Warning Disable, Enable Display Fixture Warning Messages
LED Temperature XXX / C° Temperature in Fixture
Fixture Life Time (0) Hours Total Hours of Fixture Usage
Led Usage Time (0) Hours Total Hours of LED Usage
Firmware Version App: 1.1 Boot: ≥ 1.0 Software Versions
Zoom Motor No, Yes Reset Zoom Motor
No, Yes Reset Fixture Settings to Default
15
Disable, Enable Set OLED Display Backlight Function
www.elationlighting.com
Dimmer Curve Modes
Select dimming modes (Standard, Stage, TV, Architectural, Theatre).
www.elationlighting.com 16
DMX CHANNEL FUNCTIONS AND VALUES
Supports Software Versions: App: ≥1.1 | Boot: ≥1.0
6CH
7CH
8CH
9CH
11CH
12CH
RED
0 - 255
Red (0-Black, 255-100% Red)
GREEN
0 - 255
Green (0-Black, 255-100% Green)
BLUE
0 - 255
Blue (0-Black, 255-100% Blue)
WHITE
0 - 255
White (0-Black, 255-100% White)
COLOR TEMPERATURE
0 - 255
Continuous WHITE Color Temp Control 10,000K - 3,200K
COLOR MACROS
010 - 014
LEE 790 - Moroccan pink
020 -024
LEE 332 - Special rose pink
030 - 034
LEE 345 - Fuchsia pink
040 - 044
LEE 181 - Congo Blue
050 - 054
LEE 120 - Deep Blue
060 - 064
LEE 132 - Medium Blue
070 - 074
LEE 161 - Slate Blue
080 - 084
LEE 202 - Half CT Blue
090 - 094
LEE 353 - Lighter Blue
100 - 104
LEE 116 - Medium Blue Green
110 - 114
LEE 139 - Primary Green
120 - 124
LEE 122 - Fern Green
130 - 134
LEE 088 - Lime Green
140 - 144
LEE 104 - Deep Amber
145 - 149
LEE 179 - Chrome Orange
160 - 164
LEE 778 - Millennium Gold
180 - 201
White 4000K
235 - 239
Random Color Macros FAST Speed
DMX MODE / CHANNEL
1 1 1 1 1 1
2 2 2 2 2 2
3 3 3 3 3 3
4 4 4 4 4 4
N/A N/A N/A N/A 5 5
VALUE FUNCTION
000 - 009 Open. RGBW Color Mixing Enabled
015 - 019 LEE 157 - Pink
025 - 029 LEE 328 - Follies pink
035 - 039 LEE 194 - Surprise pink
045 - 049 LEE 071 - Tokyo Blue
055 - 059 LEE 079 - Just Blue
065 -069 LEE 200 - Double CT Blue
N/A N/A N/A 5 N/A 6
075 - 079 LEE 201 - Full CT Blue
085 - 089 LEE 117 - Steel Blue
095 - 099 LEE 118 - Light Blue
105 - 109 LEE 124 - Dark Green
115 - 119 LEE 089 - Moss Green
125 - 129 LEE 738 - JAS Green
135 - 139 LEE 100 - Spring Yellow
150 - 154 LEE 105 - Orange 155 - 159 LEE 021 - Gold Amber
165 - 169 LEE 135 - Deep Golden Amber 170 - 174 LEE 164 - Flame Red 175 - 179 White 3200K
202 - 207 White 6000K 208 - 229 White 8000K 230 - 234 White 10 000K
17
240 - 244 Random Color Macros Medium Speed 245 - 249 Random Color Macros SLOW Speed 250 - 255 OPEN
www.elationlighting.com
Supports Software Versions: App: ≥1.1 | Boot: ≥1.0
Specifications subject to change without any prior written notice.
DMX MODE / CHANNEL
6CH
7CH
8CH
9CH
11CH
12CH
0-31
LEDs OFF
64-95
Strobe Effect SLOW to FAST
128-159
Pulse Effect SLOW to FAST
192-223
Random Strobe SLOW to FAST
0-255
Intensity 0 to 100%
ZOOM
0-255
NARROW to WIDE
21-40
STAGE
41-60
TV
101-255
DEFAULT to UNIT CURVE SETTING
ZOOM RESET
085 - 255
NO FUNCTION
VALUE FUNCTION
32-63 LEDs ON
SHUTTER / STROBE
N/A N/A N/A 6 6 7
N/A 5 5 7 7 8
N/A N/A 6 N/A 8 9
5 6 7 8 9 10
N/A N/A N/A N/A 10 11
6 7 8 9 11 12
96-127 LEDs ON
160-191 LEDs ON
224-255 LED ON
0-255 Dimmer Intensity FINE Adjustment
0-20 STANDARD
61-80 ARCHITECTURAL
81-100 THRATRE
000 - 079 Normal 080 - 084 Reset
DIMMER INTENSITY
DIMMER INTENSITY FINE
DIMMER CURVES
www.elationlighting.com 18
CLEANING AND MAINTENANCE
CAUTION
Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.
Never use alcohol, solvents, or ammonia based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three months,
to make sure the circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose screws may
fall out during normal operation resulting in damage or injury as larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
19
www.elationlighting.com
TECHNICAL SPECIFICATIONS
SOURCE
7x 30W Osram™ Cool White LED 30,000 Hour Average LED Life*
*May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
EFFECTS
7° - 40° Motorized Zoom 38 Color Macros and Variable Speed Macro Effects Variable 3,200-10,000K Color Temperatures Selectable Dimming Curve Effects
COLOR
RGBW
CONTROL / CONNECTIONS
3 DMX Channel Modes (3 / 6 / 8) (5) Multiple DMX Channel Modes (12 total channels) Adjustable Refresh Rate (600-28,800 (Hz) Adjustable Gamma Brightness (2.0, 2.2, 2.4, 2.8) 4 Button 180° Reversible OLED Menu Control Display DMX and RDM Protocol Support IP Rated 5pin DMX In/Out powerCON TRUE1Power In/Out
SIZE / WEIGHT
Length: 12.4” (316mm) Width: 9.6” (245mm) Vertical Height: 7.8” (197mm) Weight: 19.0 lbs. (8.6kg)
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz 250W Max Power Consumption 14°F to 113°F (-10°C to 45°C)
APPROVALS / RATINGS
CE | IP65
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
www.elationlighting.com 20
DIMENSIONAL DRAWINGS
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
OPTIONAL ACCESSORIES
ORDER CODE ITEM
QUICK RIG CLAMP Low Profile Quick Release Clamp
NEU088 3 ft. (1m) powerCON TRUE1 Power Link Cable
Additional Cable Lengths Available
21