This connection MUST be made in order for the Z630 to mute the music
whenever a Page and Door Chime is initiated.
NOTE: If using a PZ6 Precision Panel, this connection is made automatically
thru the PZ6 PC board.)
630
600 to 630 CONNECTIONS
IR INPUTS
ELAN
C45P
White/Brown
ELAN
C45P
Blue
600
CONTROL
OUTPUTS
DOOR SPEAKER ASSEMBLY CONNECTIONS
Blue
Wh/Blue
Orange
Wh/Orange
Green
Wh/Grn
Brown
Wh/Brown
(M+)
(M-)
(DB-)
(L+)
(L-)
(DB+)
(DS+)
(DS-)
4 twisted-pair
shielded cable
w/ drain wire
(min. 24 AWG)
(max. length 400')
DRAIN
WIRE
Cut
DRAIN
WIRE
M+
M -
DB+
DB-
DS+
DS-
L+
L-
Door
Station
N.O.
COM
to Electronic
Door Latch
ELAN
C45P
Z600
Door Speaker
Input 1 or 2
RELAY CONNECTIONS
i.e. RelayControlled Device
DC
Power
Supply
i.e. Dry Contact
Controlled Device
Blue
Wh/Blue
Orange
Wh/Orange
Green
Wh/Green
Brown
Wh/Brown
ELAN
C45P
Z600
RELAY
Output
Relay 1 COM.
Relay 1 N.O.
Relay 3 N.O.
Relay 2 N.O.
Relay 3 COM.
Relay 2 COM.
Relay 4 COM.
Relay 4 N.O.
BLUE
WHITE/BLUE
ORANGE
WHITE/ORANGE
GREEN
WHITE/GREEN
BROWN
WHITE/BROWN
1
2
3
4
5
6
7
8
PIN # COLOR CODE
FRONT
CABLE
Standard ELAN RJ-45 Pin-Out
TAB
to VC-
+
-
Z027
White/Blue
White/Orange
White/Green
Brown
ELAN
C45P
to VC+
White/Orange
White/Brown
Green
Brown
ELAN
C45P
Z600
CONTROL
Output Jack
to VCto VC+
Z600
CONTROL
Output Jack
Using the Z600's Internal Power Supply
(Max 5 Volume Controls w/ Override)
Using the Z027 External Power Supply
(for use with 6 to 30 Volume Controls w/ Override)
tie
together
CONNECTING ELAN VOLUME
CONTROLS WITH OVERRIDE
Complete Z Series Installation Manuals for each Z Series component are available for download from the ELAN Web Site, www.elanhomesystems.com
P/N 9900006 April 2003
RJ11
Z600 TELCO IN
Telephone Service IN
RJ11
Z600 PHONE OUT
to Telephone Punchdown
block for the connection
of house extensions
Always use Telephone Line Surge Protection
between the incoming telephone service and
the Z600 Communications Controller.
TELEPHONE SERVICE CONNECTIONS
Connections when NOT using a PZ6 Precision Panel (see reverse side for Z600 connections to the PZ6)
IMPORTANT NOTES:
1. If you are NOT using a PZ6 Precision Panel make sure to connect the
Page & Door Chime Control wires between the Z600 and the Z630
PreAmp Controller (see Z600 to Z630 Connections diagram). If using a
PZ6, this connection is made automatically.
2.
3. The four Z600 Relays are activated using telephone key presses
(# - 1 - 1, # - 1 - 2, # - 1 - 3, # - 1 - 4).
4. Modems, alarm systems, fax & answering machines, satellite & cable
boxes should be connected 'in front of' the Z600
Make sure to connect the Z600 P&DB OUT to the Z630 P&DB IN
only
600 COMM CONTROLLER QUICK REFERENCE GUIDE
C.O. Line IN
Tel. Surge
Protector
Z600
House
Phones
Fax, Modem,
Sat. & Cable Boxes,
Answering Machine
TELEPHONE LINE FLOW CHART
(ELAN Z Power
Controller)
PAGE # - 7(P)
DOOR # - 3(D)
HOLD # - 4(H)
MUTE # - 6(M)
BYPASS # - 9
RELAY # - 1 - 1, # - 1 - 2,
# - 1 - 3, # - 1 - 4
FUNCTION KEYS
A caller is automatically placed On-Hold when the # key is pressed.
The Hold feature (# - 4) is only used when you want to hang up the phone and move to another one.
No extra key presses are needed to dial out - just pick the phone and dial.
The System Bypass feature (# - 9) is used when calling automated services such as a bank or credit card company. When
you hang up, the Z600 automatically come back on-line.
A USER'S QUICK REFERENCE CARD IS ENCLOSED WITH EVERY Z600. PLEASE MAKE SURE TO LEAVE IT WITH
THE HOMEOWNER
USAGE TIPS