Elan Z600 Quick Reference Manual

600 COMM CONTROLLER QUICK REFERENCE GUIDE
Z600 FRONT PANEL ADJUSTMENTS
Page Loop-Thru Level
Page & Door Chime Output Level
(Pull back left side of front panel strip to access)
MOH Input Level
DIP SWITCH SETTINGS
1. (Factory Default: Selects whether the or key
is used to initiate ELAN telcomm features.
2. (Factory Default: 65ms)
Switch to 85ms only if experiencing intermittent drop-outs during a phone conversation.
3. (Factory Default: 75ms)
Switch to 1.25 sec. only if experiencing trouble with Call Waiting functions.
4. (Factory Default: +3dB)
Switch to '0' if the Door Speaker is too loud or you are experiencing feedback from the Door Speaker.
5. (Factory Default: +3dB)
Switch to '0' dB if the Door Mic is too loud or you are experiencing feedback from the Door Mic.
#
)
#
*
1 2 3 4 5
*
#
65
85
.75
1.25
0
+3
0
+3
POUND/STAR
DEBOUNCE
FLASHHOOK
DSPKR GAIN
MIC GAIN
(Factory Default settings shown)
Always use Telephone Line Surge Protection between the incoming telephone service and the Z600 Communications Controller.
DOOR SPEAKER ASSEMBLY CONNECTIONS
PZ6 Door Speaker Connector
Blue Wh/Blue
Wh/Green
Wh/Orange Green
Orange
Brown Wh/Brown
M+ M­DB­L+ L­DB+ DS+ DS-
4 twisted-pair
shielded cable
w/ drain wire
(min. 24 AWG)
(max. length 400')
DRAIN WIRE
Cut
DRAIN
WIRE
Blue Wh/Blue Orange Wh/Orange Green Wh/Green Brown Wh/Brown
M+ M ­DB-
DB+ DS+ DS-
L+
L-
Door
Station
N.O. COM
to Electronic Door Latch
GND nc TIPTELCO RINGTELCO TIPPHONE RINGPHONE nc P&DB
Telco Connector
TELCO CONNECTIONS
Telephone Service IN
to Punch-
down Block
PZ6 #1
Zone
Connector
GND
+12V
485-
485+
IR
VC-
VC+
nc
GND +12V 485­485+
IR
VC-
VC+
nc
any of the PZ6 Zone
Connectors may be used
PZ6 #2 Zone Connector
GND
nc
TIPTELCO
RINGTELCO
P&DB
TIPPHONE
RINGPHONE nc
GND nc
PZ6 #1
Telco
Connector
TIPTELCO
RINGTELCO
P&DB
TIPPHONE
RINGPHONE
nc
PZ6 #2 Telco Connector
DUAL PZ6 INTERCONNECTS
to
PZ6
'Control'
to
PZ6
'Relay'
from Z630
Source #1 or dedicated MOH source
used for
stand-alone
applications
(see Z600
Installation Manual)
to Z630
P&DB IN
to PZ6 DS1
to PZ6 DS2
to
PZ6
'Telco'
to
PZ6
'Phone'
Z600 to PZ6 PRECISION PANEL FRONT PANEL CONNECTIONS
Z600 TO PZ6 PRECISION PANEL REAR PUNCHDOWN CONNECTIONS
RELAY CONNECTIONS
Relay-Controlled
Device
DC Power Supply
R1 COM R1 N.O. R2 COM R2 N.O. R3 COM R3 N.O. R4 COM R4 N.O.
Relay Connector
Relay-Controlled Device
VC­VC+ VC­VC+ VC­VC+ VC­VC+
ELAN Volume
Control w/
Override
VC­VC+
VCO Connector
OVERRIDE CONNECTIONS
NOTE: Plug the Z027 +12VDC Power Supply
into the VCO jack on the front of the PZ6.
Complete Z Series Installation Manuals for each Z Series component are available for download from the ELAN Web Site, www.elanhomesystems.com
P/N 9900006 April 2003
See reverse side for Z600 connections when NOT using a PZ6 Precision Panel
ELAN C4545 Interconnect Cables
This connection MUST be made in order for the Z630 to mute the music whenever a Page and Door Chime is initiated.
NOTE: If using a PZ6 Precision Panel, this connection is made automatically thru the PZ6 PC board.)
630
600 to 630 CONNECTIONS
IR INPUTS
ELAN C45P
White/Brown
ELAN C45P
Blue
600
CONTROL OUTPUTS
DOOR SPEAKER ASSEMBLY CONNECTIONS
Blue Wh/Blue Orange Wh/Orange Green Wh/Grn Brown Wh/Brown
(M+) (M-) (DB-) (L+) (L-) (DB+) (DS+) (DS-)
4 twisted-pair
shielded cable
w/ drain wire
(min. 24 AWG)
(max. length 400')
DRAIN WIRE
Cut
DRAIN
WIRE
M+ M -
DB+
DB-
DS+ DS-
L+ L-
Door
Station
N.O. COM
to Electronic Door Latch
ELAN C45P
Z600 Door Speaker Input 1 or 2
RELAY CONNECTIONS
i.e. Relay­Controlled Device
DC Power Supply
i.e. Dry Contact Controlled Device
Blue Wh/Blue Orange Wh/Orange Green Wh/Green Brown Wh/Brown
ELAN C45P
Z600 RELAY Output
Relay 1 COM. Relay 1 N.O.
Relay 3 N.O.
Relay 2 N.O. Relay 3 COM.
Relay 2 COM.
Relay 4 COM. Relay 4 N.O.
BLUE WHITE/BLUE ORANGE WHITE/ORANGE GREEN WHITE/GREEN BROWN WHITE/BROWN
1 2 3 4 5 6 7 8
PIN # COLOR CODE
FRONT
CABLE
Standard ELAN RJ-45 Pin-Out
TAB
to VC-
+
-
Z027
White/Blue White/Orange
White/Green Brown
ELAN C45P
to VC+
White/Orange White/Brown
Green Brown
ELAN C45P
Z600 CONTROL Output Jack
to VC­to VC+
Z600 CONTROL Output Jack
Using the Z600's Internal Power Supply
(Max 5 Volume Controls w/ Override)
Using the Z027 External Power Supply
(for use with 6 to 30 Volume Controls w/ Override)
tie together
CONNECTING ELAN VOLUME CONTROLS WITH OVERRIDE
Complete Z Series Installation Manuals for each Z Series component are available for download from the ELAN Web Site, www.elanhomesystems.com
P/N 9900006 April 2003
RJ11
Z600 TELCO IN
Telephone Service IN
RJ11
Z600 PHONE OUT
to Telephone Punchdown block for the connection of house extensions
Always use Telephone Line Surge Protection between the incoming telephone service and the Z600 Communications Controller.
TELEPHONE SERVICE CONNECTIONS
Connections when NOT using a PZ6 Precision Panel (see reverse side for Z600 connections to the PZ6)
IMPORTANT NOTES:
1. If you are NOT using a PZ6 Precision Panel make sure to connect the Page & Door Chime Control wires between the Z600 and the Z630 PreAmp Controller (see Z600 to Z630 Connections diagram). If using a PZ6, this connection is made automatically.
2.
3. The four Z600 Relays are activated using telephone key presses (# - 1 - 1, # - 1 - 2, # - 1 - 3, # - 1 - 4).
4. Modems, alarm systems, fax & answering machines, satellite & cable boxes should be connected 'in front of' the Z600
Make sure to connect the Z600 P&DB OUT to the Z630 P&DB IN
only
600 COMM CONTROLLER QUICK REFERENCE GUIDE
C.O. Line IN
Tel. Surge
Protector
Z600
House Phones
Fax, Modem, Sat. & Cable Boxes, Answering Machine
TELEPHONE LINE FLOW CHART
(ELAN Z Power Controller)
PAGE # - 7(P) DOOR # - 3(D) HOLD # - 4(H) MUTE # - 6(M) BYPASS # - 9 RELAY # - 1 - 1, # - 1 - 2, # - 1 - 3, # - 1 - 4
FUNCTION KEYS
A caller is automatically placed On-Hold when the # key is pressed. The Hold feature (# - 4) is only used when you want to hang up the phone and move to another one. No extra key presses are needed to dial out - just pick the phone and dial. The System Bypass feature (# - 9) is used when calling automated services such as a bank or credit card company. When you hang up, the Z600 automatically come back on-line. A USER'S QUICK REFERENCE CARD IS ENCLOSED WITH EVERY Z600. PLEASE MAKE SURE TO LEAVE IT WITH THE HOMEOWNER
USAGE TIPS
Loading...