DO NOT connect the AC power cord until all other connections have been completed.
Unpack the HC8. Verify that you have all package contents. You should have received:
HC8 DB9 Male to RJ45 Adapter (8) Can Mount Brackets (2)AC Power cord Safety Sheet Mounting Screws (8)
HCREM Remote Quick Install Guide (This Document)
AAA Batteries (2) Rack Brackets (2)
Mount the HC8 in the desired location. Use the included rack ears and screws if mounting in an equipment rack. When choosing the location for the HC8 keep heat management and ventilation in mind. The HC8 should not be directly located above heat sources such as amplifiers. When possible the HC8 should be mounted at the bottom of the gear rack. In very warm locations (i.e.: enclosed rack or cabinet) leave a rack space above and/or below the HC8. For can mount applications, use the can mounting bracket.
Serial Connections
Connect up to 8 RS232 controlled devices using the included DB9 to RJ45 adapters. Two RS485 ports are also available for a total of 10 serial ports. Connect serial inputs from PPIS panels when using GCIREs. Suggested Cat5 wiring is 568 for the RS232 port connections to the DB9-RJ45 adapters. Refer to the Integration Notes for Cat5 wiring for devices connected to the RS485 ports.
DO NOT move the HC8 when powered up! This unit contains a hard drive which could be damaged by shock or impact. Allow the hard drive to completely spin down before moving the HC8.
VIA!Net Connections
Connect to PPVN precision panels to provide VIA!Net communication for TS2 user interfaces. Connect to VIA!Net controlled devices like the M86A. Use the ELAN standard color code for this connection.
Insert wires in this order:
Blue White/Blue Orange White/Orange Green White/Green Brown White/Brown
1 2 3 4 5 76 8
PR3 GR
PR2 OR
PR1 BL
PR4 BR
ELAN Standard
Relay Connections
Connect to the PPCM precision panel to activate relay controlled devices like lifts, drapes and movie screens located in the zones. Connect bare leads using the screw down terminals. Only Room connections 1-2 on the PPCM have relay connections. Accepts up to 24V AC or DC and current of up to 1 amp. Relay controlled devices may be directly connected if desired.
Sense Input Connections
Connect to the Sense Input connections of the PPCM using 3.5mm stereo cables. This allows ELAN sensors connected to PPRMs to be used to trigger events or to be used when conditionals are required in programming. The connection from the HC8 provides power for the sensor. Optionally, sensors may be connected directly to the HC8 sense inputs.
IR Output Connections
Connect to IR controlled devices at the head end or by using the PPCM to connect to IR controlled devices located in zones. Use 3.5mm mono cables to connect to the PPCM.
EXTERNAL IR Input Connection
Connect to the EXT IR IN connection of a PPVN or the PPCM. This connection allows the HC8 to receive IR input from a TS2’s IR receiver (through the PPVN) or from an IR sensor connected to a PPRM, PPIS or PPIR (through the PPCM). If you need to connect both the PPCM and a PPVN to the EXT IR In of the HC8 an IR connecting block can be used. An IR sensor can be directly connected if desired.
Audio Output Connection
Connect to the source inputs of the A/V Controller. These are the line level audio output of the Internal Player. Requires a 3.5mm stereo mini to RCA adapter.
Video In/Out Connections
Connect the Video Output to the component input of a monitor to provide the On Screen Display of the HC8. Connect the Video Inputs to the component video output of the A/V Controller to allow video to loop through the HC8 when the OSD is not being displayed.
Ethernet and USB Connections
Connect the Ethernet connector to a switch or router to allow the HC8 to communicate on the network. Connect the USB connection to the dial-up modem for Voice Mail applications.
Connect AC Power Cord
Verify the HC8 is powered using the Activity Indicator LEDs.
Verify the HC8 is on the network
Using the g! Configuration software verify the HC8 is on the network. You can also “ping” the HC8’s IP address from a computer that is on the network. The HC8 comes from the factory as a DHCP client. We recommend changing the IP address using the “Config IP Info” button on g! ConnectPro to a dedicated static address outside of the DHCP range of your network.
1
2
3
4
5
6
7
8
9
10
11
12
13
To help protect your equipment from power surges and momentary power interruptions, we strongly suggest that you use a battery-backed power supply (UPS) with this equipment.
The complete HC8 Installation manual and the current Core Module software can be found and downloaded by going to www.elanhomesystems.com and following the dealer link. Be sure to
update the HC8 to the current Core Module software prior to programming.
Precision panel documentation is also located on the dealer site.
PPRM2
PPRM3
IR IN
VIANET
IR3
GND
VSNS
SNS3
PPRM1
IR2
-
GND
-
VIA-
VIA+
-
SNS3
IR1
GND
VSNS
SNS1
GND
NC1
COM1 NO1
GND
VIR
GRD
VIR
-
-
-
EXT IR IN
IR2
GND
VSNS
SNS2
GND
NC2
COM2
NO2
VIANET
-
SNS1 EXT IR INSNS2
IR3
R2
IR1
R1
NO
COM
GND
-
-
-
GND
COM
NC
NO
NC
PPVN
PPIS
+16VDC Power Supply
AC Power Connection
VIA!Net Connections
Connect to the PPCM and VIA!Net devices like the M86A. Uses the ELAN
standard color code.
Sense Input Connections
Connect to Sense Input connections on the PPCM.
EXTERNAL IR Input
OSD Output & Passthrough for component video from A/V Controller to a monitor.
Serial Connections
8 RS232 and 2 RS485 ports.
Connect to PPIS panels and/or to serial controlled devices using the supplied DB9­RJ45 adapters.
Relay Connections
Note: Only Room 1-2 punchdowns on the PPCM have relay connections.
IR Outputs
Connect to IR Output connections on the PPCM and / or to IR controlled devices located in the rack.
Audio Outputs
Connect to Source Inputs of the A/V Controller.
Provides audio out for the Internal Player.
Ethernet Connection
USB Modem Connections
Activity Indicator LEDS
EXT IR IN
RJ-45
PPIR
RJ-45
RELAY
IR OUT
SENSE
PPRM
RJ-45 to
RS-232
Adapter