eks e-light U3 Description And Manual

WWW.INFOPULSAS.LT / info@infopulsas.lt
System
e-light
U3
Medienkonverter Media Converter
Version: Manual_EL-100U3_Mediaconverter_v3.3 Beschreibung und Bedienungsanleitung Description and Manual
042000101EV10-00 042000102EV10-00 042000103EV10-00 042000111EV10-00 042000112EV10-00 042000115EV10-00 042000131EV10-00 042000133EV10-00 042000136EV10-00 042000137EV10-00 042000135EV10-00 042000151EV10-00 042000153EV10-00 042000156EV10-00 042000157EV10-00 042000155EV10-00
eks Engel GmbH & Co. KG Schützenstraße 2-4 DE-57482 Wenden-Hillmicke
Tel: +49 (0) 2762 9313-60 Fax: +49 (0) 2762 9313-7906 E-Mail: info@eks-engel.de Internet: www.eks-engel.de
Bedienungsanleitung / Manual
th)
U3
e-light
Systembeschreibung
Die Medienkonverter der Serie mit den Abmaßen von 82 x 93 x 22,5 mm. Sie zeichnen sich durch einfache Funktionalität und Bedienfreundlichkeit wie Auto-Negotiation und Auto MDI/MDIX aus sowie einem erweiterten Temperaturbereich aus.
Das flache Design des Gehäuses bietet größt mögliche Flexibilität und Sicherheit bei allen Anwendungen im Innen- und Außenbereich. Eingesetzt werden kann der wie z.B. in Kleinverteilergehäusen. In Verbindung mit den anderen Systemen der Baureihen e-Light bzw. DragonLine lassen sich somit individuelle Applikationen realisieren.
Als optische Anschlussvariante stehen neben ST, SMA, FC-PC und SC auch E­2000® zur Verfügung. Alle Systeme können sowohl über zwei Fasern als auch über eine Faser durch BIDI-Technik mit SC- oder ST-Anschluss kommunizieren. Für den Kunststoff-LWL (POF) gibt es auch eine crimp- und steckerlose Variante mit Klemmverriegelung.
In der Standardversion funktioniert der wenn alle Ports auf 100MBit/s arbeiten, ansonsten arbeitet das System in einem Cut-Through-Modus. Auf Wunsch kann das System auch mit dem Modus Store & Forward angeboten werden.
Das Gerät unterstützt zudem Link Fault Pass-Through (LFP). Durch diese Funktion wird bei einem Fehler auf der LWL-Seite die Kupferseite abgeschaltet und umgekehrt bei einem Fehler auf der Kupferseite die LWL-Seite abgeschaltet. Somit wird der Ausfall einer Verbindung auch an den Endpunkten signalisiert.
e-light
U3
überall dort, wo enge Platzverhältnisse herrschen,
e-light
U3
haben eine ultrakompakte Bauform
U3
e-light
im Modus Converter Mode,
Anschlusshinweise
Achtung: Beim Betrieb elektrischer Betriebsmittel und Anlagen stehen
zwangsläufig bestimmte Teile unter gefährlicher Spannung. Arbeiten an elektrischen Anlagen oder Betriebsmitteln dürfen nur von einer Elektrofachkraft oder von unterwiesenen Personen unter Anleitung und Aufsicht einer Elektrofachkraft, den elektrotechnischen Regeln entsprechend, vorgenommen werden.
Schalten Sie die Systeme und Endgeräte spannungsfrei. Rasten Sie das Gerät auf eine Tragschiene DIN EN auf, oder nutzen Sie die
Wandhalterung.Überprüfen Sie den sicheren Halt!
Achtung: Benutzen Sie nur die zugehörigen LWL-Anschlussstecker. Wir weisen
ausdrücklich daraufhin, dass der Anschluss mit falschen Steckverbinder Schäden an den optischen Anschlüssen hervorrufen kann! Beachten Sie zudem, dass die Stecker, die eine Verriegelung besitzen, nur in einer definierten Position montiert werden können.
Achtung: Sehen Sie nicht in den optischen Sender! Das gebündelte und
abhängig von der Wellenlänge sichtbare oder unsichtbare Licht kann zu Augenschäden führen!
Verbinden Sie den ankommenden Lichtwellenleiter mit dem optischen Empfän-
ger und den abgehenden LWL mit dem optischen Sender des LWL-System.
Benutzen Sie die beigefügten Stopfen um Sender und Empfänger des LWL-
System im nicht eingebauten oder nicht benutzten Zustand vor Verunreinigungen oder Staub zu schützen.
Achtung: Knicken Sie das LWL-Kabel nicht zu stark und beachten Sie den
Biegeradius des Kabelherstellers. Andernfalls kann das Kabel beschädigt werden und/oder die Kommunikation zwischen den LWL-Wandlern nicht mehr gewährleistet werden.
Schalten Sie die Betriebsspannung für die LWL-Systeme ein. Zur Versorgung
der Systeme wird eine Betriebsspannung von 12-65VDC benötigt, die an die Klemmen +UB und GND angelegt wird. Das System hat einen Verpolungsschutz.
Achtung bei Systemen mit BIDI: Bei Verwendung von Systemen mit optischem
BIDI-Anschluss müssen immer die optischen Anschlüsse (Transceiver) vom
Typ A mit Typ B verbunden werden . Status-LED´s: RJ45 (gelb): leuchtet bei Port verbunden, blinkt bei Daten­ verkehr auf dem Port. RJ45 (grün): leuchtet bei Vollduplex-Betrieb, blinkt bei Kollisionen. LWL (gelb): leuchtet bei Port verbunden, blinkt bei Daten­ verkehr auf dem Port. LWL (rot): ohne Funktion.
System Description
The dimension of 82 x 93 x 22,5 mm. Its features are Auto-Negotiation and Auto MDI/MDIX as well as an extended temperature range.
The flat design of the housing offers an extremely high degree of flexibility for all kinds of indoor and outdoor applications. wherever there is little space, e.g. in small distribution boxes. In connection with other systems out of the e-light and DragonLine series respectively, individual applications can be realized.
Besides ST, SMA, FC-PC and SC, E-2000® is also available. All systems can communicate via two or one fiber with the help of BIDI-technology with SC or ST-port.
The
e-light
100MBit/s. Otherwise the mode ist Cut-Trough. Optionally, the device is also available with Store & Forward mode.
Furthermore, the device supports Link Fault Pass-Through (LFP). This function makes the copper side switch off in case of a failure at the fiber optic side and vice versa. Thus, a breakdown at the terminals is signalled as well.
Hardware Installation
Power off the devices, which will be connected by using the fiber optic
system.
Snap the system onto the DIN EN rail or use the wall mount. Check the
correct holding!
Attention: Only use the correct optical connectors for the fiber optic
system. Using incorrect connectors can cause damage to the fiber optic system. Take care that connectors with a latch can only be mounted in a defined position.
Attention: Don't stare into the optical cable or the transmitter of the fiber
optic system. Visible and non visible light (depending on its waveleng of the optical transmitter can cause eye-damages!
Connect the fiber optic system by using the correct fiber optic cable. Take
care that you always have to connect an optical transmitter and an optical receiver.
Use the plugs to save the unused optical receiver and transmitter against
impurity.
Attention: Don't bend the fiber optic cable! Please refer to the
manufacturer’s specifications. Otherwise the fiber optic cable can be damaged and/or the communication will be disturbed.
Power on the devices. Please use a power supply of 12-65VDC, connected
to the terminals marked with +UB and GND. Note, that +UB has a reverse voltage protection.
Attention: BIDI Switches must always be connected from transceiver type
A to a transceiver type B (notice the label on the back of the device).
Status-LED´s: RJ45 (yellow): lights when port connected, flashes
during
data transfer. RJ45 (green): lights at full duplex mode, flashes during collisions.
Fiber Optic (yellow): lights when port connected,
flashes during data transfer. Fiber Optic (red): without any function
e-light
U3
media converters have an extra small housing with a
e-light
U3
standard mode is Converter Mode, if all ports work with
U3
is suitable
VERSION: MANUAL_EL-100U3_MEDIACONVERTER_V3.3.DOC TECHNISCHE ÄNDERUNGEN VORBEHALTEN SUBJECT TO TECHNICAL ALTERATIONS
SEITE : 1
Bedienungsanleitung / Manual
U3
e-light
Anschlussbilder / Schematics
Systembeschreibung mit BIDI / System Description with BIDI
Bei Verwendung von Systemen mit optischem BIDI-Anschluss müssen immer die optischen Anschlüsse (Transceiver) vom Typ A mit Typ B verbunden werden (siehe dazu der Hinweis auf dem rückseitigen Typenschild).
BIDI-Systems always have to be connected from
transceiver type A to a transceiver type B (notice the label on the back of the device).
VERSION: MANUAL_EL-100U3_MEDIACONVERTER_V3.3.DOC TECHNISCHE ÄNDERUNGEN VORBEHALTEN SUBJECT TO TECHNICAL ALTERATIONS
SEITE : 2
Bedienungsanleitung / Manual
U3
e-light
Typenauswahl und Technische Daten Type Selection and Technical Data
POF
Order-No. 100 FX Ports 1 x ST 1 x SMA 1 x CLAMP Fiber Kunststoff-Lichtwellenleiter / POF Fiber Type 980/1000µm Attenuation 180dB/km Bandwidth Standard-POF: 10MHz x 100m / Low-NA-POF: 150MHz x 100m Wavelength 650nm Budget 12dB Distance 40m
HCS/PCF
Order-No. 045000111EV10-00 045000112EV10-00 045000115EV10-00 100 FX Ports 1 x ST 1 x SMA 1 x E2000 Fiber HCS / PCF Fiber Type 200/230µm Attenuation 8dB/km Bandwidth 17MHz*km Wavelength 850nm Budget 12dB Distance 200m
Multimode
Order-No. 045000131EV10-00 045000133EV10-00
100 FX Ports 1 x ST 1 x SC 1 x SC 1 x E2000 Fiber Multimode Fiber Type Attenuation Bandwidth Wavelength 1310nm / BiDi: 1310nm + 1550nm Budget Distance
Singlemode
Order-No. 045000151EV10-00 045000153EV10-00
100 FX Ports 1 x ST 1 x SC 1 x SC 1 x E2000 Fiber Singlemode Fiber Type 9/125µm Attenuation 0,3dB/km Bandwidth 3,5ps/nm*km Wavelength 1310nm / BiDi: 1310nm + 1550nm Budget 16dB Distance 30km (andere Reichweiten auf Anfrage / please request for other distances)
10/100Base T/TX Port Power Supply 12-65 VDC Housing Polyamid, schwarz / Polyamide, black Weight 150g Operation Temperature -10°C - +60° C Humidity Feuchtigkeit 5-95% RHD nicht kondensierend / Humidity 5-95% RHD non-condensing EMV EN61000-6-2 / EN55022 Class B +A1 + A2
EL100U3-1TX-1FX-PO-ST EL100U3-1TX-1FX-PO-SMA EL100U3-1TX-1FX-PO-CL
045000101EV10-00
EL100U3-1TX-1FX-HC-ST EL100U3-1TX-1FX-HC-SMA EL100U3-1TX-1FX-HC-E2
EL100U3-1TX-1FX-MM-ST EL100U3-1TX-1FX-MM-SC
EL100U3-1TX-1FX-SM-ST EL100U3-1TX-1FX-SM-SC
RJ45 / Autonegotiation / Auto MDX/MDIX / unterstützt Längen bis 100m / supports cable till 100m (Cat5e)
045000102EV10-00 045000103EV10-00
800 (500)MHz*km
EL100U3-1TX-1FX-MM-SC-BIDIA EL100U3-1TX-1FX-MM-SC-BIDIB
045000136EV10-00 045000137EV10-00
50(62,5)/125µm
1dB/km
12(15)dB
5000(4000)m
EL100U3-1TX-1FX-SM-SC-BIDIA EL100U3-1TX-1FX-SM-SC-BIDIB
045000156EV10-00 045000157EV10-00
EL100U3-1TX-1FX-MM-E2
045000135EV10-00
EL100U3-1TX-1FX-SM-E2
045000155EV10-00
VERSION: MANUAL_EL-100U3_MEDIACONVERTER_V3.3.DOC TECHNISCHE ÄNDERUNGEN VORBEHALTEN SUBJECT TO TECHNICAL ALTERATIONS
SEITE : 3