Ekolos EVL30SW, EVL36SW, ESL30SW.BW, ESQ30SW, EFL30GW Use & Care And Installation Manual

...
R A N G E H O O D
SERIES EVL30SW
ESL30SW.BW
USE, CARE, AND INSTALLATION MANUAL
Read all lnstructions before installing and operating the appliance
XP02293( 1)
ESL36SW.BW
EFL30GW EFL36GW
ESQ30SW
ESQ36SW
1
SAFETY NOTICE .......................................... 2
INSTALLATION
Mounting Height & Clearance ........................ 3
Ducting Options ............................................. 4
Hood Specifications ...................................... 5-7
Mounting the Range Hood ............................. 8
Ductless Recirculating................................ 9
FEATURES & CONTROLS
Touch Controls .............................................. 10
MAINTENANCE
Cleaning and Metal Mesh Filter Care ............ 11
Lights ..............................................................12
13
TROUBLESHOOTING...................................
IM PORTA NT SA FETY NO TICEIM PORTA NT SA FETY NO TICE
2
3
In stallati onIn stallati on
Minimum mount height between range top to hood bottom should be no less than 28” Maximum mount height should be no higher than 36”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fi re hazard; while hoods mounted too high will be hard to reach and will lose its performance and effi ciency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood mounting height above range. Always check your
local codes for any differences.
DUCTING
A minimum of 6” round or 3-1/4”x10” rectangular duct must be used to maintain maximum air flow efficiency.
Always use rigid type metal ducts only. Flexible ducts could restrict air fl ow by up to 50%.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size from 6” to 7or 8”.
If turns or transitions are required; install as far away from opening and as far apart, between 2,
as possible.
- Mounting Height & Clearance
Minimum Mounting Height (Ducted) 8’. Hood mounted 28” above cooking surface; 64” from floor. Minimum Mounting Height (Recirculating) 8’4”. Hood mounted 28” above cooking surface; 64” from floor. Maxmimum Mounting Height 10’3”. Hood mounted 36” above cooking surface; 72” from floor.
Duct cover extension kit available for ceiling heights up to 14 feet.
4
In stallati onIn stallati on
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outsid, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
Some Ducting Options
- Ducting Options