Ekofires eko 5510, eko 5520, eko 5530 Installation And User Instructions Manual

installation and user instructions
All instructions must be handed to user for safekeeping
Revision B - 08/11
Country(s) of destination - GB/IE
eko 5510 eko 5520 eko 5530
Eko 5510
© 2009 Focal Point Fires plc.
Eko 5520
Eko 5530
INSTALLATION INSTRUCTIONS
IMPORTANT NOTES
This appliance is a high efficiency, flueless catalytic flame effect gas fire. It provides radiant and convected warmth both efficiently and safely utilising the latest type catalytic converter and burner technology. The appliance does not require a flue system of any type as the catalytic converter cleans the flue products to provide a complete com­bustion system, which is intrinsically safe. It is designed to operate on Natural Gas (see data badge) and is facto­ry set for operation on the gas type, and at the pressure stated on the appliance data plate. The appliance incorporates a combustion monitoring system (Oxygen Depletion System). It must not be adjusted or put out of operation. If replaced then manufacturer’s original parts must be used. It is the LAW that all gas appliances and fittings are installed by a GAS SAFE registered person and in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards for Installation, Codes of Practice and the Manufacturers' Instructions. The installation shall also be carried out in accordance with the following:
Failure to comply with the above could lead to prosecution and deem the manufacturer’s warranty invalid.
This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space. The appliance is designed to fit various types of situations as described in sections 3.0 and 4.0. The appli­ance must be installed in a correctly sized room (see section 3.1), and the correct purpose provided ventilation must be provided (see section 4.1). It should be noted that heaters create warm air currents. These currents move heat to wall surfaces next to the heater. Installing the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air (such as tobacco smoke, candle smoke etc.) exist, may cause the walls to become discoloured.
This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present. If the appliance is used in a room as the sole source of heat, then conden­sation may occur on colder surfaces within the room.
On first light up of a new appliance, initial curing of high temperature paint and burning off of lubricants may occur for the first few hours of operation. During this period some smoke may be emitted from the outlet grille, this should be no cause for concern. Accordingly, the room should be well ventilated with all windows and doors open during this period. During this period the appliance may cause smoke alarms to sound. If this happens, reset the alarms, but do not remove the batteries.
Consult ALL instructions before installation and use of this appliance. This appliance is free from any asbestos mate­rial.
Please note: Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet, is owned by Focal Point Fires plc. You are not permitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc.
1
Section Contents Page No.
1.0 Important Notes 1
2.0 Appliance Data 2
3.0 Installation Requirements 2
3.1 Room Sizing 2
4.0 Site Requirements 2
4.1 Ventilation 5
5.0 Unpacking the Appliance 5
5.1 Component Checklist 5
6.0 Appliance Installation 5
6.1 Preparing the Appliance 5
6.2 Gas Supply Routes 6
6.3 Installation Method 1 6
6.4 Installation Method 2 7
6.5 Installation Method 3 8
6.6 Installation Method 4 9
7.0 Final Fitting 9
Section Contents Page No.
7.1 Cable Fixing 9
7.2 Checking the Burner & Spark Gap 10
7.3 Fitting the Fuel Bed (Euphoria models) 10
7.4 Fitting Decorative Hood/Frame 11
8.0 Testing and Commissioning 11
8.1 Operating the Appliance 11
8.2 Setting Pressure 12
8.3 Briefing the Customer 12
9.0 Servicing 12
9.1 Cleaning the Coals 13
9.2 Servicing the Burner Tray 13
9.3 Pilot Assembly 13
9.4 Catalyst 14
9.5 Testing for Firebox Leakage 14
10.0 Troubleshooting Guide 15 User Instructions
Manufacturers' Instructions.
The Building Regulations issued by the Department for Communities and Local Government, the Building
Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department.
Relevant British standards insofar as the relevant areas are not covered by these instructions.
For Republic of Ireland, reference should be made to the current edition of IS813 (the relevant standards
governing installation).
1.0
© 2009 Focal Point Fires plc.
APPLIANCE DATA
INSTALLATION REQUIREMENTS
The fire has been designed to be installed in two main applications; either to fit into a suitable opening cre­ated in the inner leaf of an outside wall or false chimney breast/extended fire surround built to conceal the appliance. The appliance can also be fitted into an unserviceable or inoperative fireplace served by a natu­ral draught flue but the old flue must be sealed off. It will be necessary to ventilate the old flue to prevent condensation and dampness forming, however any air vent used to ventilate the old flue must not be sited within 500mm of this appliance. If the flue can be ventilated to the outside of the building then this is usu­ally the best solution. If in doubt then advice should be sought from a local building control officer.
The appliance must be installed onto a suitable non-combustible insulating surface at least 12 mm thick covering the entire base area of the box. The fire must be used with a back panel capable of withstanding 150°C minimum. Any combustible materials directly behind the fire frame (or back panel) and close to the cavity box of the fire must be removed and replaced with non-combustible material such as cement, brown­ing, 'Superlux' board or equivalent materials.
ROOM SIZING
The room size should be a minimum of 27m3(e.g. 11’ x 11’ x 8’) to allow adequate circulation of air and
ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces must
not be separated by a door. To calculate a room size in cubic metres (m3) divide the room volume in cubic
feet (ft3) by 35.3.
SITE REQUIREMENTS
This appliance may be installed in any room in the home except bathrooms or bedrooms. Installation in liv­ing rooms is common, however other rooms such as kitchens, dining rooms and hallways are permitted, providing a suitable natural gas supply is available, and rooms sizing and ventilation requirements are strictly adhered to (see sections 3.1 and 4.1).
The appliance is designed to be versatile, and as such will operate correctly when exposed to normal gen­tle draughts experienced within the home. It is not recommended, however that the appliance be installed in areas where it is likely to be exposed to persistent strong draughts, that may be generated by outside doors or windows, air vents etc. It is recommended that the appliance should not be installed within 1 metre of any air vent.
Gas Group Inlet Pressure (± 2.0mbar) Regulator Pressure Max Energy Input (Gross) Max Energy Input (Net) Max Gas Rate Min Energy Input (Gross) Min Energy Input (Net) Min Energy Input (Gross) Min Energy Input (Net) Burner Pressures ­High Cold (±1.5 mbar). High Hot (±1.5 mbar). Low Cold (± 0.75 mbar). Low Hot (± 0.75 mbar). Flow restrictor orifice Injector Oxypilot (SIT/Bray) Gas control Gas Inlet restrictor elbow Ignition Spark Gap (± 1.0mm)
All Models
G20 Natural Gas CAT I2H 20 mbar N/A
2.3 kW
2.07 kW
0.23 m3/h
1.3 kW
1.17 kW 166 W 150 W
18.0 mbar
18.2 mbar
4.5 mbar
4.6 mbar
1.16 mm N/A 9110 BM733/NGC8602D 8mm Piezo spark
4.0 mm
2.0
3.0
3.1
4.0
2
©
2009 Focal Point Fires plc.
SITE REQUIREMENTS (continued)
Basic opening sizes (all dimensions in mm)
The basic opening dimensions for the appliance are as follows;
The opening must be within these sizes in order to accommodate the full depth of the fire box in non-combustible applications. Applications involving combustible materials e.g. timber battens in false chimney breasts, must use appropriate clearances and insulation methods as described in the relevant section of these instructions. Opening depth ‘c’ includes any plaster, cement or infill/back panels that form part of the installation.
Consideration for cable fixings, any hearth that may be required etc. should be made in addition to the basic sizes given in table 1.
Cable fixings at rear - allow an extra 20mm depth.
Hearth to be installed - allow the height of the hearth (minimum
50mm).
The appliance must be sited on a solid base (indicated in figure
1). This base may be combustible (i.e. laminate or wooden floor­ing) but must not be carpet or fabric of any kind. If the room in which the appliance is to be installed is carpeted or has a fabric floor covering then a small solid hearth will be required, meeting the dimensions specified in table 1 and illustrated in figure 2.
In all installations, the wall or back panel of the installation must be flat, non-combustible and meet the dimensions specified in table 1 and illustrated in figure 2.
The appliance may be installed as a ‘hole in the wall’ type installation, however a small hearth or ledge must be provided to support the base of the appliance and decorative facia. In this situation the thickness of the hearth or ledge may be as desired, but it must have the strength to support the weight of the appliance and the facia.
4.0
a’
‘b’
‘c’
‘e’
d’
‘f’
‘i’
‘j’
k’
Dimension:
‘a’ minimum
‘a’ maximum
‘b’ minimum
‘b’ maximum
‘c’ minimum
‘c’ maximum
‘d’ minimum ‘e’ minimum
‘f’ minimum
‘g’ minimum
‘g’ maximum
‘h’ minimum
‘h’ maximum
‘i’ minimum
‘i’ maximum
‘j’ minimum ‘j’ maximum ‘k’ minimum
‘k’ maximum
Eko 5510 & Eko 5520
560 610 410 470 105
None
50 560 140 560
As desired
655
As desired
560 610 410 470 105
None
Eko 5530
555 570 410 425 105
None
50 560 100 560
As desired
605
As desired
555 570 410 425 105
None
Figure 1
Figure 2
Base area
This area to be
flat and non-
combustible
Hearth
(if required)
‘h’
‘g’
Table 1
Figure 3
3
©
2009 Focal Point Fires plc.
SITE REQUIREMENTS (continued)
Clearances to non-combustibles
Non combustible surfaces are defined as brick, metal, marble, concrete etc. and also a number of man­made materials impervious to flame. If in doubt refer to the material manufacturer for further information before proceeding with installation.
The wall/back panel for the opening must always be non-combustible. Bare plasterboard must be protect­ed by non-combustible plaster or replaced with non-combustible material (e.g. Superlux board). Any gap between wall boards and the wall must be filled using glass fibre insulation, silicone mastic or similar mate­rial to prevent heat ingress.
Any type of fire surround used with this appliance must be adequately sealed to the wall and floor to pre­vent excess draughts around the back of the fire. The temperature rating of any surround used must be 150°C minimum.
Clearances to the sides of the appliance are 100mm (4”). Clearance to the front of the appliance is 500mm (20”).
The sides and back of the appliance may be installed directly onto a non-combustible surfaces.
A non combustible shelf of any depth may be positioned above the appliance provided it is no closer than 200 mm from the top of the appliance glass panel and the wall above the appliance is non combustible. The shelf itself and any articles placed on it must also be tolerant of high temperatures.
Clearances to combustible materials
Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any material, which is likely to discolour, melt or misshape when exposed to moderate heat, should be considered as a combustible material or surface.
Clearance to the sides of the appliance facia are 100mm (4”) but curtains, drapes and other fabrics are not permitted within a distance of 500mm (20”) of the appliance sides. No such materials are permitted direct­ly above the appliance regardless of distance.
The minimum clearance to the ceiling above the appliance is 800mm (31.5”) measured from the top of the appliance glass panel.
Combustible materials should not be positioned directly in front of the appliance within a distance of one metre.
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below.
The shelf depth may be greater but the height must also be increased accordingly. An increase in height of 25 mm is required for every 12.5 mm of additional shelf depth. For shelves that are too low protective devices can be used such as metal heat deflectors, but it must be assured that the shelf does not reach an unacceptable temperature before relying on such a solution.
Under no circumstances should any electrical equipment e.g. plasma screen TV sets etc. be positioned on the wall above the appliance.
Clearance to the sides and rear of the firebox are a 75mm (3“) air-gap. Clearance to the top of the firebox is a 100mm (4”) air-gap.
It should be established that any mirrors or picture frames etc. to be positioned on the wall above the appli­ance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their installation.
If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integri­ty and ability of the wall to carry the weight of the appliance must be confirmed. It is important in these cir­cumstances that any vapour control barrier is not damaged, and that any structural members of the house frame are not damaged - refer to section 6.5.
4.0
Maximum depth of shelf Minimum distance from hearth to underside of shelf
150mm 950 mm
100mm 850 mm
4
©
2009 Focal Point Fires plc.
VENTILATION
A minimum of 100 cm2purpose provided ventilation is required for this appliance. This may be achieved either with one vent 100 cm2at a high or low position in the room, or split ventilation i.e. 50cm2be installed at high level and 50cm2be installed at low level within the room. An openable window or equiv­alent is also required.
To reduce the possibility of draughts, road noise or insects entering the room via the air vent, we recom­mend the use of “Black Hole”, “Vortex” or “Centurion” type vents featuring internal baffles. The requirements of any other gas, oil or solid fuel appliances operating in the same room or space must be taken into con­sideration when assessing ventilation. Any ventilation fitted must comply with BS 5871 part 4 and BS 5440 part 2. Ventilation fitted under, or within immediate vicinity of the appliance must not be used as it may adverse­ly effect performance of the ODS system. For Republic of Ireland refer to the current edition of IS813 and any relevant rules in force. The appliance shall not be installed within 1 metre of any existing air vent, and any new air vent shall not be installed within 1 metre of the appliance.
UNPACKING THE APPLIANCE
Lift off the remaining packaging components. Check that the components supplied correlate with the com­ponent checklist. Please dispose of all the packaging materials at your local recycling centre.
COMPONENT CHECKLIST
APPLIANCE INSTALLATION
Note: Ensure that the gas supply is isolated before commencing installation of the appliance.
The fireplace opening and environment must be in compliance with specifications laid down in the appro­priate sections of these instructions.
PREPARING THE APPLIANCE
Remove the appliance from its carton as described previously and stand on a dustsheet. Remove the hood and glass panel and place safely to one side.
Knock out holes are provided in the rear and sides of the firebox for use where concealed pipework is required. Note: Knock out holes are also provided in the sides of the inner firebox if a side-entry pipe rout­ing is required, but it is essential to seal these holes with grommets. Knock out the appropriate hole in the cavity box with a sharp tap from a hammer and fit the rubber grommet supplied. A small incision can now be made in the rubber to slip snugly around the outside of the supply pipe and sleeving.
Warning : Do not install or use the appliance without this seal in place.
5.0
5.1
6.0
6.1
4.1
QUANTITY DESCRIPTION
1 Firebox and burner assembly 1 Set of manufacturer’s instructions 1 Contemporary Facia (Eko 5530 models) 1 Traditional One-Piece Frame (Eko 5510 & Eko 5520) 1 Cast Firefront (Eko 5510 & Eko 5520) 1 Coal Set (Coal effect models) 1 Rubber grommet 1 Cable fixing kit 1 Screw pack including fibre rawlplugs
Eko 5530 models screw pack consists of:
2 No. 8 pozi self tapping screws
Eko 5510 & Eko 5520 screw pack consists of:
2 No. 8 pozi self tapping screws 2 M5 x 7 screws
5
©
2009 Focal Point Fires plc.
GAS SUPPLY ROUTES
Following preparation of the fixing method, the concealed gas supply (if required), can now be installed. When the opening is ready for installation the gas supply can be routed. If the gas pipe has been sleeved the ends of the sleeving must be sealed. The end of the 8mm pipe should be temporarily sealed to prevent the ingress of debris during fixing.
An inlet restrictor elbow is supplied as part of the appliance.
All installation pipework must be in accordance with the current edition of BS 6891, and for timber framed dwellings, the current edition of IGE/UP/7.
In order to avoid unnecessary pressure drops, no more than 1.5m of 8mm diameter pipe must be used. If a concealed gas connection is to be made, the supply pipe should always be sleeved through walls and floors using the shortest possible route. For concealed supply pipe routing, pipes must (where possible) be vertical and providing there is sufficient wall thickness available, they should be placed in pipe chases. Horizontal pipe runs should be avoided. Prior to chasing a solid wall, an inspection should be made to note the proximity of any cables/sockets outlets which may already be buried. Pipes must be secured using suit­able clips and protected against corrosion. Ideally factory finished protected pipework and fittings should be used. Joints should be kept to a minimum and compression fittings must not be used. The pipework installation must be tested for tightness before any protection is applied and/or the pipework and fittings are buried.
INSTALLATION METHOD 1 (against a non-combustible inside wall)
This method requires no modifications to the internal wall of a property and is achieved by using either a surround with extended rebate or a false chimney breast of minimum 105mm internal depth. If cable fixings are to be used then the minimum depth should be 125mm.
A false chimney breast should be installed, taking into account any guidance given in the section on tim­ber framed buildings as far as insulation and clearances are concerned. When the false chimney breast is constructed from combustible materials the firebox must be separated from any combustible materials by a minimum 75mm air gap at the sides and rear and 100mm air gap above the firebox. Alternatively the fire­box may be insulated with 75mm of fibre glass wool or rock wool to the sides, rear and 100 mm to the top.
6.2
6.3
Figure 4
False chimney breast
Non combustible back panel
Non combustible inside wall of building
Outer leaf of building
6
©
2009 Focal Point Fires plc.
INSTALLATION METHOD 2 (recessing into a non-combustible wall)
This method allows for installation of the appliance with the rear of the firebox recessed into the inner leaf of a cavity wall. This should enable a standard fire surround and back panel/hearth set to be fitted to the wall with the fire presented naturally in a flush fitted manner. The structural integri­ty of the wall must be maintained.
Check the cavity insulation type (if applicable). If cavity insulation is of a loose fill variety, take precautions to prevent excessive loss of material when the inner leaf is opened up by packing the cavity firmly with a minimum 50mm of rockwool or glass fibre. This will hold back any loose material now or in the future.
To maintain the structural integrity of the wall it is recommended that a suitable lintel is fitted. It is some­times possible to install this appliance without a lintel, depending on the type of wall. The guidance of a qualified professional or local building control officer is essential to confirm this.
Mark out the area of the proposed fireplace opening on the wall. Obtain a suitable concrete or steel lintel from a builder's merchant. Drill four holes at the corners of the lintel position and squarely over the fire­place opening, and if possible centrally under a block joint . Clear out the block work in the area and insert the lintel by saw, or stitch drill and chisel. Do not dry bed the lintel - always bed on mortar and securely slate pin. Clear out the block work from below the lintel to form the opening for the firebox to be insert­ed.
The top of the exposed area of cavity must be sealed against the ingress of moisture dripping from above. The best way to do this is a cavity tray but an easier and quicker method is to affix a 'Supalux' or equiva­lent board into the cavity. Slope the board towards the outside wall and support with screws, cement, 'Unibond' or silicone mastic etc. This will guide all moisture, harmlessly, to the outside wall. The exposed sides of the cavity must be packed with a suitable depth (minimum 50mm) of glass fibre or rock wool to prevent draughts and heat loss, even if no loose fill material is present. It is good practice to insulate the rear of the fire from the cavity to prevent heat loss and condensation.
The hearth may now be put in place (If fitted). Again this should not bridge the cavity where it projects into the wall space. Finally install the fireplace or fire surround and back panel/marble to its finished location.
6.4
Figure 5
Outer leaf of building
Non combustible back panel
Non combustible inside wall of building
Lintel
7
Figure 6
© 2009 Focal Point Fires plc.
INSTALLATION METHOD 3 (timber framed buildings)
Where removal of any part of a timber frame is undertaken the structural integrity of the wall must be retained. The advice of your local building control officer should be sought. If the property is under any NHBC warranty it is also advised that their advice on this kind of modification is sought.
Either of the two preceding installation methods may be adapted for timber framed buildings, providing extra care is taken in ensuring combustible materials are adequately protected from the effects of heat.
The appliance must be installed in accordance with the British Gas documents DM2 and DM3 or the Institute of Gas Engineers published procedure document IGE/UP/7.
Special attention must be paid to the location of studwork frames of the inner leaf and the appliance posi­tioned accordingly. Wires and pipes that run within the wall must also be taken into account.
Installation as per method 1 (against inner wall)
When using this method of installa­tion the following amendments should be incorporated. A 75mm air gap or 75mm of insulation (e.g. rockwool) must be provided between combustible materi­als and the sides and rear of the cavity box. A 100 mm air gap or 100mm of insulation (e.g. rock­wool) must be pro­vided to the top of the cavity box. It is also a good idea to enable as much airflow as possible, into and out of the area behind the fire without excessive heat loss from the room when the fire is off.
Installation as per method 2 (recessing into a wall)
When setting the appliance into the wall find a suitable position between frame timbers and open up the hole. Secure back the damp proof mem­brane to prevent ingress of damp. Again 50mm insula­tion plus a 12mm thick fire retardant board, 'Superlux' or equivalent, must be provided between combustible materi­als and the sides and rear of the cavity box. 100 mm of insulation plus a 12 mm thick fire retardant board, 'Superlux' or equivalent, must be provided to the top of the cavity box. The exposed cavity should be sealed off using non-combustible board, ('Supalux' or equivalent), made into a 4-sided box. It is also good prac­tice to further insulate the cavity with a 50mm layer of Rockwool outside the Superlux box. Note that the appliance should not be allowed to bridge the cavity in this installation method. It is also a good idea to enable as much airflow as possible, into and out of the area behind the fire without causing excessive heat loss from the room when the fire is off.
6.5
8
Figure 7
Outer leaf of building
Non combustible back panel
Combustible inside wall of building
Rockwool insulation 75mm sides and rear, 100mm top
False chimney breast
50mm of Rockwool to insulate cavity
Superlux Box, 12mm thick, External dims; Height 677, Width 529mm, Depth 167mm.
Rockwool insulation, 50mm sides and rear, 100mm top.
Combustible inside wall of building
Figure 8
© 2009 Focal Point Fires plc.
INSTALLATION METHOD 4
This method allows for a ‘hole in the wall’ installation of the appliance with the rear part recessed into the inner leaf of a cavity wall. The structural integrity of the wall must be maintained. The wall must be non-combustible.
Refer to section 6.4 (recessing into a non-combustible wall). Eko 5530 models : If the appliance is to be wall mounted then the entire base of the appliance must be supported by a non-combustible shelf. It may be desirable for the shape of the shelf to follow the profile of the appliance. In this case the footprint of the appliance is shown in figure 10, and any flush fitting shelf design may be calculated from the measurements given. Eko 5510 & Eko 5520 models : If the appliance is to be wall mounted then the entire base of the appliance must be supported by a non-combustible shelf. The dimensions of such a shelf are given in section 4.0 (site requirements).
FINAL FITTING
If not previously carried out, insert the firebox into the opening. If the appliance is to be screw fixed to the back panel/wall or inside of the opening then suitable locations for such fixings should be established, and a suitable number and type of such fixings should be established to ensure the appliance is securely fixed. There are no purpose provided screw fixing points provided on the firebox as the location of these points will vary from installation to installation, depending on the strength of the surrounding materials and the various sizes of opening that the appliance may be required to fit into. A cable fixing kit, however, is pro­vided and should be used wherever possible as the default fixing method. Carefully insert the firebox into the opening and guide the gas pipe through the sealing grommet into its final routing position and fit the restrictor inlet elbow supplied to the gas pipe. Secure the firebox by insert­ing screws in the previously prepared locations (if screw fixing) or refer to the following section if cable fix­ing.
CABLE FIXING
When using this method for fixing, the minimum depth of the opening must be increased from 105 mm to 125 mm. This is to allow for the eyebolts and a space for the cable tensioning. Remove the appliance glass panel by removal of the four retaining screws. Remove the burner unit - refer to section 9.2.
Drill four holes as shown in figure 11 and fit the fibre rawlplugs. If the fireplace does not allow for the exact lay­out shown, the eyebolts should be fixed to give as similar a configuration as possible. Thread both tensioning cables through the holes in the protruding tabs on the rear of the firebox then through the eyelets and back through the lower holes in the firebox.
Push the firebox back into the fireplace, centralise, pull the loose cables through the holes and into the bottom of the cavity box. Thread the cable tensioners onto the cables with the nuts screwed down close to the tensioner head. Slide the screwed nipple onto the cable, pull cable taut and tight­en nipple. Adjust tensioner using a suitable spanner to pull the appliance back into position, to allow an even pull around the fireplace opening. Visually inspect and repeat if necessary to achieve a good fit.
Note: Surplus cable MUST NOT be cut off, as this will prevent proper re-installation after servicing. Coil up the surplus cable and tuck the coils out of the way.
6.6
7.0
9
555
405
504
40
192
92
Figure 10All dimensions in mm
Figure 9
7.1
A
B
C
A. 350 mm B. 330 mm C. 70 mm Dimension ‘A’ can be +/-10mm
Figure 11
© 2009 Focal Point Fires plc.
CHECKING THE BURNER AND SPARK GAP
Non-coal effect models : There are no imitation fuel bed components to install. The appliance features a
ribbon burner which is designed to produce a continuous band of flame over it’s length. The burner should be visually inspected to ensure it is free from any foreign matter. If it is necessary to clean or dust off the burner then (if fitted) the glass door should be removed by removal of the four retaining screws. Re-fit the glass door after cleaning or inspection, ensuring a good seal. Coal effect models : The burner should be visually inspected to ensure it is free from any foreign matter. If it is necessary to clean or dust off the burner then (if fitted) the glass door should be removed by removal of the four retaining screws. Fit the fuel bed as described in section 7.3. All models : The gap between the spark electrode and the pilot should be 3 - 5mm to produce a good spark. There should be no need to adjust this. If under any circumstances the piezo electric spark fails, the pilot cannot be lit manually.
FITTING THE FUEL BED (where applicable)
The appliance features a coal style fuel effect.
1.Place the rear coal strip onto the shelf behind the burner as shown in figure 14. Ensure that the four protruding screw heads engage the hollow areas on the underside of the piece.
2.Position the front coal piece onto the front of the burner as shown in figure 15.
Re-fit the glass panel using 4 M6 screws. The fire is designed to operate correctly with the supplied components according to the instructions. Never add coals. Never put combustible or non-combustible materials, rubbish or other matter into the fire.
7.3
10
7.2
Figure 12
Spark gap
Figure 13
Figure 14
Figure 15
© 2009 Focal Point Fires plc.
FITTING THE DECORATIVE FRAME, FRONT AND HOOD
The appliance is supplied with a decorative frame and hood. Attach the hood using two M6 screws as shown in figure 16.
Eko 5510 & Eko 5520 models : Remove all protec­tive film from the frame. The frame is retained by four magnets on the front face of the firebox. Position the frame onto the magnets. IMPORTANT : Due to the possibility of sharp edges, care should be taken when handling the frame. The use of protective gloves is recommended. Place the firefront into position in front of the fire. Do not use any other firefront other than the one supplied with this appliance. The firefront shown in these instructions may differ from the one supplied with the appliance.
Eko 5530 models : Hang the decorative facia assembly onto the firebox as shown in figure 17. Secure in position using two no.8 self tapping screws as shown in figure 18.
TESTING AND COMMISSIONING
Turn on and test the gas supply up to the fire for any leaks, in accordance with the current edition of BS6891.
OPERATING THE APPLIANCE
The control knob is supplied in the loose parts pack. Fit the control knob onto the valve spindle as shown in figure 19.
The pilot is visible behind the left hand side of the burner. Push in and turn the control knob to the SPARK position, and hold there for a few seconds. Continue turning anti-clockwise through the spark click to the PILOT light position, ensuring the pilot has lit. If not, return the knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed for approximately ten seconds. Now release the knob and the pilot should stay alight. If the pilot is extinguished during use, wait three minutes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clockwise to the high position. The main burner should light after a few seconds. To decrease the setting to low, turn the control knob clockwise to the LOW setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. To turn the fire off, keep the knob pressed in, return to the OFF posi­tion and release.
11
7.4
8.0
Figure 16
8.1
Figure 19
Figure 17
Figure 18
© 2009 Focal Point Fires plc.
SETTING PRESSURE
The pressure test point is located on the left hand side of the appliance, on the main burner pipe, next to the brass restrictor/connector. Release the setting pressure test point screw (shown in figure 20), and attach a pressure gauge.
Light the fire on the HIGH setting.
To commission the appliance, the burner pressure must be in accordance with the figures stated in section 2.0 of these instructions. The fire is factory set to achieve these pres­sures and any significant variation could indicate a supply problem. If the pressure is too high, the gas supply meter may be set incorrectly. This should be checked with the fire running and if necessary reset by the gas supplier.
If the burner pressure is too low, then check the inlet pres­sure with the appliance running. If this is less than the inlet pressure stated in section 2.0 of these instruc­tions it will need to be reset by the gas supplier. If the setting pressure is too low, but the meter pressure is acceptable, then a problem in the supply pipework is to be suspected.
Upon satisfactory checking of the burner pressure, turn the fire off, disconnect the pressure gauge and refit the test point screw. Light the fire and check for gas soundness.
In the event that the burner pressure is not in accordance with the figures stated in the data section of these instructions, the appliance must not be commissioned, and the manufacturer should be contacted for guid­ance.
BRIEFING THE CUSTOMER
All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire. After commissioning the appliance, the customer should be instructed on the safe use of the appliance and the need for regular servicing. Frequency of service depends on usage, but MUST be carried out at least once annually. Advise that cleaning of the fire maybe achieved when the fire is cold using a damp cloth and mild detergent on most surfaces. Advise that the fire will emit a "newness" smell for a time after initial com­missioning and that extra ventilation may be needed during this time. Recommend that a guard be used for the protection of young children, pets, the elderly and the infirm.
SERVICING
Isolate the fire from the gas supply. Ensure that the fire is fully cold before attempting service. A sug­gested procedure for servicing is detailed below.
1. Lay out the dustsheet and tools.
2. Remove the frame and front/facia and then remove the hood (two M6 screws).
3. Remove the glass door assembly (four M6 screws) and clean carefully.
4. Coal effect models only : Carefully remove the ceramic components.
5. Inspect the catalyst and clean if necessary with a soft brush.
6. Disconnect the gas supply and remove the four screws retaining the burner (two in the burner legs and two in the rear of the firebox).
7. Lift away burner assembly.
8. Strip off the burner pipes and clean thoroughly.
9. Clean the in-line restrictor, pilot assembly and the burner tube. Do not attempt to remove the pilot injector as this can cause damage.
10. Re-assemble and re-fit the burner tray.
11. Turn on the gas supply and leak test. Check pilot and burner for good ignition.
12. Coal effect models only : Refit the ceramics as per these installation instructions.
13. Refit the glass door assembly, ensuring a good seal.
14. Refit the hood.
15. Check any purpose provided ventilation is un-obstructed.
16. Light the fire and check setting pressures.
17. Carry out combustion check as per section 9.4.
17. Check safe operation of the appliance.
For specific servicing instructions, see relevant sections.
12
8.2
8.3
9.0
Figure 20
© 2009 Focal Point Fires plc.
CLEANING THE CERAMICS
Remove the frame and front/facia and place to one side. Remove the hood. Remove the glass door assem­bly. Remove the ceramic components. Gently clean in the open air with a soft brush. Be careful not to cre­ate dust from the ceramics. Where necessary replace damaged components with genuine spares. Seal scrap ceramic components in plastic bags and dispose at proper refuse sites as directed. If using a vacuum clean­er a HEPA filtering system is recommended.
Re-fit the ceramics by referring to the relevant section of these instructions. Refit the glass door assembly ensuring a good seal. Refit the hood, front and frame/facia.
SERVICING THE BURNER TRAY AND GAS ASSEMBLY
Firstly, remove the front, frame/facia and hood, the glass panel (Coal effect models : remove ceramics), data plate and disconnect the gas connection at the isolator elbow. Remove the burner tray by removing the four securing screws shown in fig­ure 21.
Remove the pilot and main burner pipes and blow through to dislodge any debris. Now remove the restrictor elbow and blow through to make sure it is entirely clear. Unclip the pilot lint gauze and clean with a soft brush. Clean the exterior of the pilot assembly with a soft brush and blow through the flame ports on the pilot head. Check the aeration holes are free from lint or dirt. The pilot assembly can be removed if required by disconnecting the electrode HT lead, gas pipe and unscrewing the mounting screws and lifting away.
The pilot assembly is a non-serviceable item and should not be taken apart. Aeration holes must be absolutely clear internally for proper operation. NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. Modifications are dangerous and can have serious unseen effects on safety. If the pilot will not stay lit there is a problem with dirt, the gas supply to it, or the thermocouple needs replacement.
The gas valve is a non-serviceable item. If this needs replacement, remove M4 securing screw holding the valve in place, remove all pipe unions, electrode lead, thermocouple lead and then the complete valve. Replacement must be original manufacturers parts. Re-assembly is the reverse of removal. Ensure setting pressures are as stated in Section 2; Appliance Data.
Re-assembly in the reverse of removal.
PILOT ASSEMBLY
Clean the pilot assembly with a soft brush and blow through. Check the aeration holes are free of any dirt or lint. Clean thoroughly internally, the connection can be removed from the base of the pilot unit using two spanners to make cleaning easier. Do not damage or try to dismantle the pilot injector.
The unit is factory set and the only check necessary is to ensure the spark gap is correct. See specifica­tions for gas setting.
NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. If the pilot will not stay lit there is a problem with dirt, the gas supply, or the thermocouple needs replacement. Modifications are dangerous and can have a serious unseen effect on safety and therefore MUST not be done. Replacements must be original manufacturers parts. Re-assemble in the reverse of removal. Ensure setting pressures are as stated in Section 2; Appliance Data.
9.2
9.1
9.3
Figure 21
13
© 2009 Focal Point Fires plc.
CATALYST
It is recommended that the catalytic converter is inspected for signs of damage and dirt during routine serv­icing procedures. The expected life of the catalyst is in excess of 11,000 hours (10 years of normal use). After this time the catalytic converter should be replaced.
If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vac­uum cleaner. If removed for cleaning ensure the seals are in good condition before replacing the catalytic converter. New seals will usually be required.
The performance of the catalyst may be checked using an analyser as follows. Any analyser used should conform to BS7927 : 1998 + A1 : 1999 or BS EN 50379-3.
Important: The temperature of the gases emmited by the catalytic converter is in excess of 400
o
C. Measuring gas of this temperature may damage some types of gas analysers. If in doubt consult the equipment manufacturer.
Position gas sample probe directly in front of the catalyst underneath the hood, in the centre of the upper firebox. Ignite the fire as per the operating instructions, and run at high setting for 15 minutes. Record the carbon dioxide (CO2) concentration and then the carbon monoxide (CO) concentration as displayed by the analyser - also noting the units in which the values are expressed.
Most analysers display carbon dioxide (CO2) concentrations in percentage (%) terms and carbon monoxide concentration in parts per million (ppm) terms.
In order to calculate the combustion ratio for the appliance (CO/CO2) it is first necessary to express both gas concentrations in terms of percentage. To convert from parts per million (ppm) to a percentage (%) divide the ppm figure by 10,000. Examples : 35ppm = 0.0035%, 15ppm = 0.0015%, 5ppm = 0.0005%.
Now divide the concentration of carbon monoxide (CO) expressed in percent by the concentration of car­bon dioxide (CO2) to obtain the appliance combustion ratio.
The combustion ratio of the gasses emitted by the catalytic convertor should not exceed 0.0015.
If replacing the catalytic converter, remove the hood, front fret/facia and the grille (as shown in figure 22). The catalytic converter retaining clamp is secured with 4 nuts and slip proof washers, located on the inside of the firebox, at the top, remove these nuts and the clamp can be removed. Withdraw the clamp, followed by the catalytic converter and its seals from the firebox and discard.
Refit a new catalytic converter and seal in reverse order.
TESTING FOR FIREBOX LEAKAGE
Appliances that are several years old or have been extensively dismantled should be checked for sound­ness. It is important that all the products of combustion pass through the catalytic converter at the top of the firebox before leaving the appliance.
The firebox is heated by lighting for a few minutes to provide a flow through the firebox. The burner is then shut off and a smoke pellet or match introduced at the base of the fire underneath the burner tray. Large quantities of smoke will emerge from the top of the appliance, but none should emerge from the joints or gasket faces, especially around the door.
It is important to note that the appliance can never be expected to be 100% smoke tight and small quan­tities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the fire is in operation.
9.4
9.5
CO (%) CO2 (%) = ratio
Figure 22
14
©
2009 Focal Point Fires plc.
TROUBLESHOOTING GUIDE
Fire sparks but pilot does not light No gas to fire, check isolators are open and gas supply is on.
Pipework blockage, clean out.
Air not fully purged, re purge supply or wait longer.
Spark earthing to metalwork, reset gap correctly.
Blocked pilot, clean out internally.
Pilot lights but then goes out Severe restriction in gas supply: clear obstruction.
Faulty thermocouple, replace pilot unit.
Blocked pilot, clean out.
Blocked lint gauze, clean.
Hold control knob in for longer.
Check control knob does not foul indicator plate.
If the pilot will not stay lit there could be a problem with contami
nation of the gas supply, drafts, room size and/or ventilation or the thermocouple needs replacement.
Modifications are dangerous and can have a serious unseen effect on safety.
NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT.
Fire does not spark at pilot HT lead detached, refit.
Check the spark gap (see section 8.2).
Faulty piezo unit, replace.
Debris shorting out electrode, clean.
Spark shorting to metalwork under tray, check routing of HT lead under burner.
Fire runs for a time Loose or faulty thermocouple, rectify. and then cuts off Blocked pilot, clean out.
Fire is sited in a draft.
Door or window has been opened creating a draft.
Wall on which fire is sited has a hole/holes through which there is a draft.
Fire is too close the an air vent.
Fire is sited on disused chimney breast which has not been adequately sealed up.
Dirt or lint in pilot aeration hole or on the lint gauze, clean thoroughly.
If the pilot will not stay lit there could be a problem with contami
nation of the gas supply, drafts, room size and/or ventilation or the thermocouple needs replacement.
Modifications are dangerous and can have a serious unseen effect on safety.
NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT.
Pilot flame shrinks when Poor gas flow to fire, check pressure with fire on high. fire is on high If pressure is low, remove any restriction in pipework or valve.
Check all isolators are adequately sized and fully open.
Check meter pressure is adequate.
If the pilot will not stay lit there could be a problem with contami
nation of the gas supply, drafts, room size and/or ventilation or the thermocouple needs replacement.
Modifications are dangerous and can have a serious unseen effect on safety.
NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT.
Fire smells when first lit or in use Newness smell from brand new appliance.
Leakage occurring. Carry out leakage test and rectify any problems.
Combustible materials used in incorrect positions.
Airborne substances such as cleaning materials/air fresheners
are being drawn through the fire.
Other airborne contaminants such as dust, tobacco smoke, paint vapours.
10.0
15
©
2009 Focal Point Fires plc.
USER INSTRUCTIONS
Section Contents Page No
1.0 Important Notes 1
2.0 Fire Front/Facia 2
3.0 Clearances to Combustibles 2
4.0 Ventilation and Room Size 3
5.0 Operating Instructions 3
6.0 Combustion Monitoring System 3
7.0 Fitting the Fuel Bed 4
8.0 Cleaning 4
9.0 Servicing 4
10.0 List of Replacement Parts 4
IMPORTANT NOTES
The installation and Servicing of this fire MUST only be carried out by a GAS SAFE registered person in
accordance with local Codes and/or Regulations, Building Regulations and the manufacturer's instruc­tions.Failure to comply with the above could lead to prosecution and invalidate the appliance warranty. In the event of gas leakage from the appliance, the gas supply must be turned off at the nearest isolating valve. This appliance is only suitable for the gas type for which it is supplied.
Keep a note of the installer's name and address, the original purchase receipt and the date of installation. Failure to produce this information may invalidate the warranty. The appliance should be serviced regular­ly to ensure continued safe operation. See the servicing section for further reference.
The guard (glass front) is to prevent risk of fire or injury from burns and no part of it should be perma­nently removed. It Does Not Give Full Protection For Young Children Or The Infirm. Parts of this appli­ance become naturally hot during use. It is recommended that a suitable fireguard is used, especially where young children, pets, the elderly or infirm are concerned. The manufacturer of this appliance considers all surfaces as working surfaces with the exception of the control knob and control panel.
Combustible items, such as flooring and furniture and soft wall coverings (such as blown vinyl or embossed paper), low temperature surrounds etc may discolour if fitted too close to the fire. See relevant section for further details on clearances to combustibles. No combustible materials or flooring should pro­trude onto the hearth (if fitted).
This appliance incorporates a combustion monitoring system (ODS).
• DO NOT burn any foreign material on this fire. Under no circumstances shall the appliance be used if the
glass front door or panel has been removed, damaged or is open. On no account should the appliance inlet or outlet openings be blocked or obstructed in any way (see figure 1). DO NOT place objects on top of the appliance.
• WARNING: Due to the nature of this product the area around the top of the appliance (i.e. the grille) gets very hot. Care should be taken when operating the appliance.
The integral catalysts should be checked by the installer upon servicing to ensure there are no defects or obstructions that may prevent the satisfactory flow of combustion products. The expected life of the cata­lyst is in excess of 11,000 hours (10 years of normal use). After this time the catalyst should be replaced.
1.0
1
©
2009 Focal Point Fires plc.
FIREFRONT/FACIA
This fire is supplied with a particular style of fire front. Use of the fire front will ensure an adequate air­flow under the firebox for the correct functioning of this appliance. Compliance with safety standards can­not be guaranteed when another style of front is used.
CLEARANCES TO COMBUSTIBLES
Clearances to non-combustibles
Non combustible surfaces are defined as brick, metal, marble, concrete etc. and also a number of man­made materials impervious to flame. If in doubt refer to the material manufacturer for further information before proceeding with installation.
The wall/back panel for the opening must always be non-combustible. Bare plasterboard must be protect­ed by non-combustible plaster or replaced with non-combustible material (e.g. Superlux board). Any gap between wall boards and the wall must be filled using glass fibre insulation, silicone mastic or similar mate­rial to prevent heat ingress.
Any type of fire surround used with this appliance must be adequately sealed to the wall and floor to pre­vent excess draughts from around the back of the fire. The temperature rating of any surround used must be 150°C minimum.
Clearances to the sides of the appliance are 100mm (4”). Clearance to the front of the appliance is 500mm (20”).
The sides and back of the appliance may be installed directly onto a non-combustible surfaces.
A non combustible shelf of any depth may be positioned above the appliance provided it is no closer than 200 mm from the top of the appliance glass panel and the wall above the appliance is non combustible. The shelf itself and any articles placed on it must also be tolerant of high temperatures.
Clearances to combustible materials
Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any material, which is likely to discolour, melt or misshape when exposed to moderate heat, should be considered as a combustible material or surface.
Clearance to the sides of the appliance facia are 100mm (4”) but curtains, drapes and other fabrics are not permitted within a distance of 500mm (20”) of the appliance sides. No such materials are permitted direct­ly above the appliance regardless of distance.
The minimum clearance to the ceiling above the appliance is 800mm (31.5”) measured from the top of the appliance glass panel.
Combustible materials should not be positioned directly in front of the appliance within a distance of one metre.
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below.
The shelf depth may be greater but the height must also be increased accordingly. An increase in height of 25 mm is required for every 12.5 mm of additional shelf depth. For shelves that are too low protective devices can be used such as metal heat deflectors, but it must be assured that the shelf does not reach an unacceptable temperature before relying on such a solution.
Under no circumstances should any electrical equipment e.g. plasma screen TV sets etc. be positioned on the wall above the appliance.
Clearance to the sides and rear of the firebox are a 75mm (3“) air-gap. Clearance to the top of the firebox is a 100mm (4”) air-gap.
It should be established that any mirrors or picture frames etc. to be positioned on the wall above the appli­ance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their installation.
2.0
3.0
2
Maximum depth of shelf Minimum distance from hearth to underside of shelf
150mm 950 mm
100mm 850 mm
© 2009 Focal Point Fires plc.
VENTILATION AND ROOM SIZE
Purpose provided ventilation of 100cm2is required for this appliance. An openable window or equivalent is also required. Any ventilation fitted must comply with BS 5871 part 4 and BS 5440 part 2. Ventilation fit­ted under, or within immediate vicinity of the appliance must not be used as it may adversely effect per­formance of the combustion monitoring system (ODS) system. The appliance shall not be installed within 1 metre of any existing air vent, and any new air vent shall not be installed within 1 metre of the appliance.
The requirements of other appliances operating in the space or room must be taken into consideration when assessing ventilation requirements, this will have been carried out by your GAS SAFE registered installer. A supply of fresh air into the room is advisable to maintain temperatures within limits.
This appliance must not be installed in a bedroom or a bathroom. For Republic of Ireland, see relevant rules in force.
The room size should be a minimum of 27m3(e.g. 11’ x 11’ x 8’) to allow adequate circulation of air and ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces must not be separated b y a door. Note : To calculate a room size in cubic metres (m
3
) divide the room volume in cubic
feet (ft3) by 35.3.
It should be noted that heaters create warm air currents. These currents move heat to wall surfaces next to the heater. Installing the heater next to vinyl or cloth wall coverings or operating the heater where impu­rities in the air (such as tobacco smoke, candle smoke etc.) exist, may cause the walls to become dis­coloured.
This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present. If the appliance is used in a room as the sole source of heat, then condensation may occur on colder surfaces within the room.
OPERATING INSTRUCTIONS
The control knob is marked as shown in figure 1. The pilot is visible behind the left hand side of the burn­er. Push in and turn the control knob to the SPARK position, and hold there for a few seconds. Continue turning anti-clockwise through the spark click to the PILOT light position, ensuring the pilot has lit. If not, return the knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed for approximately ten seconds. Now release the knob and the pilot should stay alight. If the pilot is extinguished during use, wait three minutes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clockwise to the high position. The main burner should light after a few seconds. To decrease the setting to low, turn the control knob clockwise to the LOW setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. To turn the fire off, keep the knob pressed in, return to the OFF position and release.
COMBUSTION MONITORING SYSTEM
This fire is fitted with a combustion monitoring safety device (ODS). If the fire shuts down during use for no apparent reason then several reasons may be suspected. If a door or window has been opened creat­ing a draught, then pilot disturbance could be the problem and removal of the draught should resolve this. The fire can then be re-lit in accordance with the previous section. A grommet seal may also be missing from the firebox causing abnormal draught to shut down the pilot. Call your installer to check seals are properly fitted.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF, call in your installer to check the appliance and ventilation. Remedial work must be carried out as required. DO NOT allow the appliance to be used until the appliance and installation is passed as safe. If the pilot continues to be extinguished you must call your installer to check the operation of the complete appliance.
3
4.0
5.0
Figure 1
6.0
© 2009 Focal Point Fires plc.
FITTING THE FUEL BED (where applicable)
The appliance features a features a coal style fuel effect.
1. Place the rear coal strip onto the shelf behind the burner as shown in figure 2. Ensure that the four protruding screw heads engage the hollow areas on the underside of the piece.
2. Position the front coal piece onto the front of the burner as shown in figure 3.
Re-fit the glass panel using 4 M6 screws. The fire is designed to operate correctly with the supplied components according to the instructions. Never add coals. Never put combustible or non-combustible materi­als, rubbish or other matter into the fire.
CLEANING
Before carrying out any of the following operations, ensure that the appliance is OFF and completely cold. Regularly clean around the appliance to ensure that dust, fluff, pet hair etc, are kept to a minimum. There are no other specific requirements for care, other than regular cleaning of the general appliance. A wipe with a dry cloth is normally sufficient. DO NOT use abrasive cleaners as they can damage the finish. Metal parts may be cleaned using an appropriate metal cleaner or baby oil. Test on a hidden part of the metal before cleaning. Clean only in the direction of the grain. GLASS PANEL - This can be cleaned with a suitable glass cleaner. Test on a small area first. PAINTED AREAS - These can be cleaned using a dry cloth. FINISHED METAL AREAS - These can either be cleaned using a proprietory metal cleaner or baby oil. Test on a small hidden part before cleaning. Always clean in the direction of the grain.
SERVICING
The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot. The frequency of service will depend on usage, but MUST be carried out at least once annually. Servicing must be carried out by a competent person, such as a GAS SAFE registered installer.
LIST OF REPLACEMENT PARTS
The Installation instructions carry full servicing details for the use of the installer.
PART NO. ITEM
F550272 Glass door assembly F550241 Hood (Eko 5530) F550234 Hood (Eko 5510 & Eko 5520 models) F820191 Silver Decorative facia assembly (Eko 5530 models) F820190 Silver Decorative frame (Eko 5510 & Eko 5520 models) Please enquire Firefront (Eko 5510 & Eko 5520 models) F730041 Gas Valve F730069 Pilot assembly F510018 Burner unit (Coal effect models) F510035 Burner unit (Non-coal effect models) F780079 Catalyst (seal kit must also be supplied) F940136 Seal kit for Catalyst
7.0
Figure 2
Figure 3
10.0
8.0
9.0
As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or spec­ifications without prior notice.
F860625