SITE REQUIREMENTS
For aesthetic purposes it is essential that the hearth and infill plinth area are flat and level. The
hearth and infill must also be square to the back panel. Failure to comply with this could cause
the appliance to lean away from the fireplace resulting in an unsatisfactory installation.
The electrical earth to the property and all wiring must be carried out in accordance with IEE
Wiring Regulations (including any Local Regulations). If you are unsure about this aspect, then
professional advice should be sought. This appliance is suitable for use with a 230V~50Hz (ac)
single phase (normal domestic) electrical supply. Connection to the mains supply should be made
with the three core cable (green/yellow -earth, blue - neutral, brown - live) to a fixed fused spur
with double pole insulation (minimum 3mm separation of poles) and fused at 3 amp. Take care
not to pull or damage the internal wiring to the the fan unit at any time during installation. Should
the mains cable become damaged at any stage, it should only be replaced with the manufacturers supplied cable (part no. EL006225/0). Failure to use a genuine spare could cause a hazard.
WARNING! THIS APPLIANCE MUST BE EARTHED.
If a concealed gas supply is to be used, the supply pipe must be sleeved through walls and floors.
If the fire is to be inset into the cavity leaf, only factory sleeved pipe should be used. For further
details see relevant section. A separate isolation device must be incorporated into the incoming
gas supply to facilitate servicing. No more than 1.5 metres of 8mm pipe should be used in the
connection of the gas supply to the appliance, as more could result in an unacceptable drop in
pressure.
This appliance must only be installed onto a non-combustible wall or surface. The fire requires a
hearth with a non-combustible surface at least 12mm thick. The top surface of the hearth must
be at least 50mm above floor level, or be surrounded by a raised edge or fixed fender of at least
50mm high. The non-combustible hearth must extend a minimum of 300mm in front of, and
150mm either side of the live part of the appliance. The hearth must therefore be a minimum of
680mm wide.
The appliance must be installed by one of the following methods;
1 - Fitment against an existing inner house wall with a suitably constructed fireplace
and/or false chimney breast to enclose the depth of the fire.
2 - Insertion into a purpose made opening in the inner leaf of a cavity wall or disused fire
place opening with the use of a suitable fireplace surround etc. Note: The appliance must
not bridge the cavity - any overhang being kept to a minimum, and the Installation
instructions must be adhered to. Building Control requirements may vary in some
areas, enquiries should be made accordingly.
3 - Installation into a timber framed dwelling using the clearances to combustible materi-
als shown in the relevant section. Building Control requirements vary in some areas,
enquiries should be made accordingly.
An unprotected combustible shelf may be fitted above the appliance, provided it complies with
the minimum dimensions stated below. Protective materials can be used to deflect heat from
shelves that are too low.
A non-combustible shelf may be fitted to within 10mm of the top edge of the fireframe.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the
frame of the firebox providing it projects no further forward than 100mm (4in). As with all heating appliances, decorations, soft furnishings and wall coverings (such as blown vinyl, flock and
embossed paper) may discolour or scorch if positioned too close to the fire. If the appliance is fitted to a dry-lined wall, the gap between the plasterboard and blocks must be sealed with noncombustible material and any unplastered board replaced with superlux or other non-combustible
material if in direct contact with the appliance.
4
5.0
Maximum depth of shelf Minimum distance from finished hearth
surface to underside of shelf
100mm (4in) 745mm (29 1/4 in)
150mm (6in) 845mm (33 1/4 in)
203mm (8in) 895mm (35 1/4 in)
© 2009 Focal Point Fires plc.