EK Lights Nitec GIG-PAK T12 User Manual

Four high-output, slim-profile
RGB tri-color LED par lights
with included IR6 remote,
power and DMX cables,
and custom carry bag
TABLE OF CONTENTS
SAFETY / GENERAL INSTRUCTIONS
DIMENSIONS
OVERVIEW : CONNECTIONS Rear view
INSTALLATION Mounting
FUNCTIONS AND SETTINGS Function menu Menu structure
- Auto Show
- Static Color
- Sound Mode
- Manual Color
- Dimmer
- Linking
- DMX Conguration
- DMX Addressing
- DMX cable connection
- DMX termination notes
DMX FUNCTION CHART 3-channel mode 8-channel mode
IR6 REMOTE CONTROL OPERATION Auto Mode Sound Active Mode Manual Color Mode Other functions
MAINTENANCE / TROUBLESHOOTING
- LITEPAR T12 (4)
- Power cables (4)
- DMX cables (3)
- IR6 remote
- Carry bag
- User Manual
- Warranty Card
PACKING CONTENT
2
- 4 - MAINTENANCE
4.1 MAINTENANCE AND CLEANING THE UNIT
• Make sure the area below the installation place is free from unwanted persons during setup.
• All screws used for installing the device and any of its parts should be tightly fastened and should not be corroded.
deformation.
• The main cables must be in impeccable condition and should be replaced immediately even when a small problem is detected.
• It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or other particles to ensure that the light is radiated at maximum brightness. For cleaning, disconnect the main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then carefully wipe the part dr y. For cleaning other housing parts use only a soft, clean cloth. Never use a liquid, it might penetrate the unit and cause damage to it.
4.2 FUSE REPLACEMENT
1. Disconnect this product from the power outlet.
2. Remove the safety cap by a screwdriver.
3. Replace the blown fuse with a fuse of the exact same type and rating (T1A,250V).
4. Install the safety cap, and
reconnect power.
4.3 TROUBLESHOOTING
Fuse
Fig.13
Problems Possible causes Checks and remedies
Fixture does not light up
No mains supply
Dimmer fader set to 0
All color faders set to 0
Faulty LED
Faulty LED board
Check the power supply voltage
Increase the value of the dimmer channels
Increase the value of the color channels
Replace the LED board
Replace the LED board
General low light intensity
Dirty lens assembly
Misaligned lens assembly
Install lens assembly properly
Fixture does not power up
No power
Loose or damaged power cord
Faulty internal power supply
Check for power on power outlet
Check power cord
Replace internal power supply
Fixture does not respond to DMX
Wrong DMX addressing
Damaged DMX cables
Bouncing signals
Check control panel and unit addressing
Check DMX cables
Install terminator as suggested
Contact an authorized service center in case of technical problems or not reported in the table can not be resolved by the procedure given in the table.
15
3.15 OPERATION THROUGH THE IR6 CONTROLLER
To control the LITEPAR T12 with the infrared remote control:
• Press the button MENU repeatedly until SET
• Using UP/DOWN button to select On or to enable or disable the infrared remote control.
NOTE - Make sure to point the controller directly at the receiver on the product.
Automatic Mode
Automatic Mode will enable you to run the automatic programs on the product. To turn on Automatic Mode:
1. Press AUTO on the controller.
2. To adjust the speed of the automatic program:
1. Press SPEED on the controller.
2. Press %.
3. Press + or – to either increase or decrease the speed of the program.
Sound Active Mode
Sound Active Mode will enable the product to respond to the music. To turn on Sound Active mode:
1. Press SOUND on the controller. To adjust sound sensitivity in Sound Active mode:
1. Press SENSITIVITY on the controller.
2. Press %.
3. Press + or – to either increase or decrease sound sensitivity.
Manual Color Control
1. Press MANUAL on the controller.
2. Press any number between 0-9 to choose your color. To manually control the RGB percentage:
3. Press MANUAL on the controller.
4. Press R, G, or B to choose your color.
5. Press + or – to increase or decrease the percentage of each color.
Miscellaneous Operation
To adjust the strobe rate of the program:
1. Press STROBE on the controller.
2. Press + or – to increase or decrease the strobe rate.
• Press FADE/SNAP on the controller.
To black out the lights:
• Press BLACK OUT on the controller.
NOTE - The controller will not respond to any inputs when Black Out is activated. If the remote does not respond when a button is pressed, try pressing BLACK OUT. You may have inadvertently activated BLACK OUT.
Fig.8
IR6 REMOTE
BLACK
OUT
AUTO
STROBE SPEED
SOUND
SENSI­TIVITY
%
MANUAL
FADE
R
G B
+
0
1
2
3
4
5
6
7 8 9
A
UV W
14
WARNING! Before carrying out any operations with the unit, carefully read this instruction manual and keep it with cure for future reference. It contains important information about the installation, usage and maintenance of the unit.
SAFETY
General instruction
• The products referred to in this manual conform to the European Community Directives and are there­fore marked with
.
• The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only. Never make risk an electric shock.
• cording to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
installer. Check that the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label.
• This unit is not for home use, only professional applications.
- in places subject to vibrations or bumps;
- in places with a temperature of over 45 °C.
an inspection or contact the manufacturer directly.
plant for a disposal which is not harmful to the environment.
Warnings and installation precautions
damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short circuit, burns, electric shock, etc.
• Always additionally secure the projector with the safety rope. When carrying out any work, always com­ply scrupulously with all the regulations (particularly regarding safety) currently in force in the country
• Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent
• The lamp (LED) shall be changed if it has become damaged or thermally deformed.
trigger epileptic seizures in photosensitive persons or persons with epilepsy.
• Do not touch the product’s housing when operating because it may be very hot.
3
Loading...