![](/html/49/4978/49788f5a4b926024c91b57c3d79b627370e016c4d677b9cfc02a6da4a187f6b2/bg1.png)
Underarm (Axillary) Method:
(Alternative method for babies or very young children. Although simpler, the axillary
method takes longer.)
Make sure the underarm is dry and there is nothin g between the c hest and a rm. Point
the thermometer upward and place the tip well into the patient’s underarm. Fold the
patient’s arm over the chest to hold the thermometer in place. This method can take up
to 2-3 minutes.
Tips for using your NOVAPLUS Digit a l Ther mometer
Your NOVAPLUS Digital Thermometer is a durable and precise medical device. Here
are some helpful hints to get the best performance from the thermometer.
1. DURING ORAL USE, KEEP THE THERMOMETER IN PLACE WITHOUT
MOVEMENT IN THE MOUTH WHILE TAKING A TEMPERATURE
2. STAY WITH CHILDREN UNTIL THE TEMPERATURE TAKING IS
COMPLETED TO A S SU RE PROPER USE OF THE THERMOM ETER
PLEASE NOTE- Fast Readout Model Thermometers are NOT recommended
for axial (armpit) readings due to the body’s slower transfer of heat in this area.
Standard readout thermometers, VDTS-100U, VDTS-100B, & VDTS-100R are
recommended for these readings
Rectal Method:
(Recommended method for babies or very young children who breathe through the ir
mouth.) Lubricate the tip of the thermometer with a water soluble jelly such as K-Y®
Jelly. Do not use petroleum jelly. T he patient should lie o n his/her side with knee s
slightly bent . If the p atient is a baby, place the baby on his/her stomach wi th legs
hanging down either across your knees or at the edge of a bed or changing table. This
positions the baby’s rectum properly for safe and easy insertion of the thermometer.
With one hand, gently slide the tip of the thermometer no more than 1/2 inch into the
rectum. If you detect resistance of any kind, STOP. Hold thermometer in place
during temperature measurement. The thermometer should not be used orally for
sanitary reasons after being used rectally.
5. LISTEN FOR BEEP – TEMPERATURE READING COMPLETED
A steady beep will normally continue for 10 seconds. This is the indication that the
temperature reading is complete. The °F sign will also stop flashing. Yo u w ill hear 3
rapid beeps if the temperature reading is greater than 100°F.
6. READ THE THERMOMETER AND RECORD THE RESULTS
Remove the thermometer after hearing the completion beeps. Read the temperature
on the d isplay. The temp eratur e on the display will not change while the power
remains on. It is advisable to inform your doctor anytime a temperature is above
100°F.
7. PRESS BUTTON TO TURN OFF THERMOMETER
The thermo meter will automatically power off in appro ximately 10 minutes.
Cleaning Instr uctions
Wash the area extending about 2” from the tip of the thermometer with alcohol before
and after each use. Dry the thermometer thoroughly.
OR…
Wipe the area described above with 70% isopropyl alcohol before and after each use.
Alcohol swabs are convenient and hygienic way of cleaning the thermometer.
Instructions for Use
1. PRESS BUTTON TO TURN ON THE THERMOMETER
A beep will so und and the scr een wil l brief ly display:
This is a “function check”, and indicates the thermometer is working properly.
2. LAST TEMPERATURE READING DISPLAYED (MEMORY FEATURE)
The thermometer stores the last temperature taken. It will automatically disp lay the
last temperature taken after the “function check.” The thermometer will display 98.6F
on first use or if a temperature was not taken the last time the thermometer was
powered on.
3. THERMOMETER IS READY FOR USE
After the “function check” and the last temperature display, the thermometer will flash
“Lo” indicating that the thermometer is ready for use.
Dual Scale-This thermomete r reads in F (Fahrenheit) and C (Celsius). To switch
scales- hold the bottom down from the OFF position until it powers on.
4. TAKING TEMPERATURE – ORAL, UNDERARM (AXILLARY), OR
RECTAL METHOD
Oral Method
Place the thermometer probe under tongue. Probe tip should
rest in the “correct area” as shown in the diagram. Hold the
thermometer in the same spot under your tongue with your
mouth closed
√ = correct areas, x = incorrect areas
.
BATTERY REPLACEMENT
1. The battery symbol “ -- ” will appear in the lo wer rig h t corner of the LCD when
the battery needs to be replaced.
2. Remove the battery cover according to the diagram below.
3. Gently pull out the circuit board with the battery chamber 1/2 inch.
4. Use a pointy object such as a pen to remove the battery from the battery chamber.
Discard the exhausted battery according to local requirements.
5. Place a new 1.5V alkaline button cell battery, type LR41, AG3, or equivalent in toe
chamber with the positive polarity facing up.
6. Push the circuit board back into place and place the battery cover on the
thermometer.
1. The battery used with the thermometer should be kept out of the reach of children.
If the battery is swallowed, call your Poison Control Center at 800-222-1222
immediately.
EKLA Corporation is committed to a s s uring that t he NOVAPLUS Digital
Thermometer is a durable and precise medical device. If you carefully follow the
instr uctions, your NOVAPLUS Digital Ther momete r s ho uld last for years. However,
if for any reason (other than abuse or normal battery replacement) you are dissatisfied
with your NOVAPLUS Digital Thermometer, we will replace it.
If you have any proble ms with your the rmometer, please check the battery before
sending it back. This is usua lly the source of the problem.
Please contact us at customerservice@eklacorp.com or call 800-328-4215.
Send your thermometer to:
EKLA Corporation
1707 Quincy Avenue Suite #127
Naperville, IL 60540