Ekamed Ekamove Operating Instructions Manual

Adjustable 30° lateral positioning system
Installation and
operating instructions
GmbH & Co.KG
Medical Aids for Geriatric
and Nursing Care
Im Stadtfelde 43 31515 Wunstorf
info@ekamed.de
Internet: www.ekamed.de
1 List of contents
1 LIST OF CONTENTS 2
ITEMS SUPPLIED 4
2 GENERAL 5
2.1 EXPLANATION OF SYMBOLS 5
2.2 NOTES ON USING THE INSTALLATION AND OPERATING INSTRUCTIONS 6
2.3 GUARANTEE, WARRANTY AND 7
LIABILITY PROVISIONS 7
2.4 SAFETY 8
3 COMBINATION WITH OTHER APPARATUS 10 4 INDICATIONS AND CONTRA-INDICATIONS 11
4.1 INDICATIONS 11
4.2 CONTRA-INDICATIONS 12
5 NOTIFICATION OF ACCIDENT AND DAMAGE 13 6 OPERATION 14
6.1 ADVANTAGES AT A GLANCE 15
7 OPERATING SUMMARY 17 8 INSTALLATION 18
8.1 INSTALLING THE AIR CHAMBER SYSTEM 18
8.2 INSTALLING THE CONTROL UNIT 20
8.3 CONNECTING AIR CHAMBER, SENSORS AND CONTROL UNIT 21
8.4 CONNECTION WITH THE MAINS SUPPLY 21
9 PUTTING THE APPARATUS INTO OPERATION 22
9.1 SWITCHING ON 22
Operating instructions ekamove Rev 3 Date: June 2017 2
9.2 SETTING THE DATE/TIME 22
9.2.1 CALLING UP THE DATE AND TIME 23
9.3 CALIBRATING THE SENSORS (OPTIONAL) 24
9.4 FACTORY SETTINGS 25
10 NORMAL OPERATION 26
10.1 STARTING THE SYSTEM 26
10.2 CARE KEY 27
10.3 CALLING UP THE VALUES SET 27
10.4 STOPPING THE SYSTEM 28
11 SELECTING THE POSITIONING PROGRAMME 29 12 SELECTING THE POSITIONING ANGLE 30 13 SELECTING THE POSITIONING TIME 31 14 FREELY PROGRAMMABLE PROGRAMME 32 15 DOCUMENTATION 34 16 CPR FUNCTION 34 17 CLEANING 35 18 MAINTENANCE 36 19 DISPOSAL 36 20 MALFUNCTIONS/ERROR MESSAGES 37 21 WARNING MESSAGES 39 22 TECHNICAL DATA 40 23 EMC COMPATIBILITY 42 24 STANDARDS 43 25 CONTACT 43
Operating instructions ekamove Rev 3 Date: June 2017 3
Items supplied
1x base unit consisting of:
Control unit with clamping device Power line (fixed to the base unit) 1 SD card 2 GB for data storage 1x air chamber system Air chamber with connection hoses Protective cover Sensors with supply cable (optional)
2x stabilising plates for sensors 1x operating instructions 1x packaging material 1x carry-pouch for transport and storage
Operating instructions ekamove Rev 3 Date: June 2017 4
CPR
R
L
Emergency deflation
Indicates the emergency deflation coupling
Symbol for hose connection, right
Symbol for hose connection, left
Plus key for selection
with programme key depressed => next programme with angle key depressed => angle value is increased with time key depressed => time value is increased
Minus key for selection
with programme key depressed => previous programme with angle key depressed => angle value is decreased with time key depressed => time value is decreased
Programme key for selecting the positioning programme
(Only in combination with Plus or Minus key)
Start key for starting the system
(In programming mode for confirming values)
Stop key for stopping the system
(In programming mode for exiting the programming mode)
Angle key for selecting the positioning angle
(Only in combination with Plus or Minus key)
Time key for selecting the positioning time
(Only in combination with Plus or Minus key)
2 General
2.1 Explanation of symbols
Operating instructions ekamove Rev 3 Date: June 2017 5
2.2 Notes on using the Installation and Operating
Instructions
These operating instructions provide some important information on working with the ekamove system. All the safety advice and handling instructions given should be followed in order to guarantee safety when working with the apparatus.
In addition, on-site accident prevention directions and general safety provisions applicable in the area where the apparatus is used should be observed.
Note!
Read the instructions very carefully before starting any work! These operating instructions belong
to the product and should be kept close to the apparatus so that they
can be consulted by personnel and
operators at all times.
If the apparatus is passed on to third parties, the operating instructions must accompany it.
The illustrations in these instructions are intended to give a clear demonstration of the actual situation and are therefore not necessarily true to scale; they may vary slightly from the actual design of the apparatus.
Operating instructions ekamove Rev 3 Date: June 2017 6
2.3 Guarantee, warranty and
liability provisions
All information and advice in these operating instructions has been compiled taking account of the applicable standards and codes and the best available technology. With appropriate operation, the ekamed GmbH & Co. KG company accepts a guarantee of 24 months as from the invoice date. During this time, in the event of defective parts or malfunction due to a production defect, the apparatus and its accessories can be repaired or replaced free of charge.
The ekamed GmbH & Co. KG company does not accept any liability for damage due to:
1. Failure to follow the operating instructions
2. Use which is not in accordance with the instructions
3. Unauthorised alterations
4. Technical modifications
5. Use of unauthorised spare parts The warranty is based on legal provisions and directives. If any work or interventions are carried out on the apparatus or its
accessories by the client or by third parties without the prior approval of ekamed GmbH & Co. KG, the warranty lapses.
For medical products within the meaning of EU Directive 93/42/EEC which have to be regularly serviced or conditioned, the warranty only applies if the prescribed maintenance intervals are observed.
Operating instructions ekamove Rev 3 Date: June 2017 7
If claims are made on the warranty and if, after checking where applicable, it should turn out that these are based on signs of wear or other forms of damage not covered by the warranty, the ekamed GmbH & Co. KG company is entitled to pass any expenses incurred (testing, transport costs and similar) on to the client.
2.4 Safety
This section provides a summary of all the important safety aspects for optimum protection of the user and third parties and for safe and problem-free operation.
The apparatus is used in the home and in care establishments (commercial area). In commercial areas the user of the apparatus must comply with legal obligations regarding safety at work.
In addition to the instructions on safe working given in these instructions, the safety, accident prevention and environmental regulations applicable to the area of use of the apparatus must be observed. The following in particular applies here:
- The operator must clearly define and manage the areas of responsibility for operation, servicing and cleaning.
- The operator must make sure that all members of personnel who handle the apparatus have read and understood the operating instructions.
Furthermore, the operator is responsible for ensuring that the apparatus is always in a technically faultless condition; therefore the following applies:
- The operator must make sure that the intervals for maintenance work described in these operating instructions are observed.
Operating instructions ekamove Rev 3 Date: June 2017 8
- The operator must make sure that authorised accessories exclusively are used in connection with the apparatus.
Warning: Changes to the ME apparatus are not permitted Note: In order to prevent the risk of an electric shock, this
apparatus should only be connected to the mains power supply via a protective earth conductor.
Do not use the ekamove system without side rails. The apparatus should not be set up in the immediate vicinity
of sources of interference such as microwaves or apparatus emitting powerful radiation. To ensure electromagnetic compatibility, the apparatus should only be connected to the mains power supply via a protective earth conductor.
The location of the apparatus and the routing of the power line should be selected so that accidental disconnection from the supply network is excluded. The power line is to be routed in such a way that it cannot be pinched or crushed. Also it should be laid in such a way that it does not present a tripping hazard.
The supply cable should only be provided by the ekamed GmbH & Co. KG company or by a company authorised by it.
The fire hazard in case of use in oxygen enriched enviroments has been vastly reduced. The housing is self-extinguishing.
Operating instructions ekamove Rev 3 Date: June 2017 9
3 Combination with other apparatus
If done properly, ekamove® can be used with a PC or laptop as an option for storing positioning data. For this, a software programme can be acquired from ekamed GmbH & Co. KG as an option. Standard commercial 2 GB SD cards can be used as the storage medium.
Installation together with an alternating pressure system is not permissible as this may result in an unstable position.
Operating instructions ekamove Rev 3 Date: June 2017 10
4 Indications and contra-indications
4.1 Indications
Ekamove® is suitable for the prevention of decubitus ulcers (prophylaxis) for patients / residents who are at risk of developing decubitus ulcers or as an auxiliary decubitus therapy for patients / residents who are already suffering from existing decubitus ulcers up to and including stage 3 (EPUAP). The system is designed for patients with a bodyweight of up to 300 kg. In exceptional cases the system can also be used for higher stage decubitus ulcers. However, it is essential that a doctor should be consulted for this and his approval is necessary.
The ekamove ® is suitable and recommended
o for pre-existing decubitus ulcers (up to and including stage
III EPUAP)
o for people with a moderate to high risk of decubitus ulcers
(as per Braden)
o for people whose disability or illness means that they must
spend long periods lying down
o for people who cannot change their position when lying
down themselves
o for people who have suffered a stroke with partial paralysis o for people with paraplegia who want to change the position
in which they are lying with the use of their arms
Operating instructions ekamove Rev 3 Date: June 2017 11
4.2 Contra-indications
The product cannot be used
o with unstable fractures o with severe burn injuries o with equilibrium disturbances o with underlying neurological diseases which lead to anxiety
behaviour in patients
Claims of any kind for damages resulting from incorrect or inappropriate use are excluded. Ekamove ® is an aid for the avoidance of decubitus ulcers and an auxiliary therapy for decubitus ulcers. Even when using ekamove® the skin should also be regularly examined by the person himself – where possible – or by carers and/or qualified medical personnel for pressure points. If no improvement occurs in the condition, specialist medical personnel should be consulted.
Note! Claims of any kind for damages resulting from incorrect or inappropriate use are excluded. The operator alone is liable for all damages in case of incorrect or inappropriate use.
Operating instructions ekamove Rev 3 Date: June 2017 12
5 Notification of accident and damage
Malfunctions or breakdowns in the apparatus which have caused personal injury must be notified without delay to the competent authority and the company ekamed GmbH & Co. KG.
Comment!
The competent authority may demand that the operator has the event to be notified assessed by an expert at his own cost and that he submits the assessment in writing. The expert is selected in agreement with the competent authority.
The technical safety assessment includes the determination of the following elements
- to what the event can be ascribed,
- whether the product was in good condition,
- whether any further hazard exists after elimination of the
defect,
- whether new knowledge has been gained which requires
other or additional precautions.
Operating instructions ekamove Rev 3 Date: June 2017 13