eka EKF 711G UD, EKF 616G UD, EKF 664G UD Original Operating And Instruction Manual

ORIGINAL OPERATING AND INSTRUCTION MANUAL
MODD. EKF 711G UD – EKF 664G UD – EKF 616G UD
rev. 2
CATEGORY II2H3+
GB
TECNOEKA S.r.l.
Via Marco Polo, n.11 - 35010 Borgoricco (Padova) Italy
Tel. +39.049.9300344 – +39.049.5791479 Fax +39.049.5794387
www.tecnoeka.com E-mail: info@tecnoeka.com
TECNOEKA Srl _____________________________________________________________ use and instruction manual
page. 2 __________________________________________________________________________________________
UE DECLARATION OF CONFORMITY
Annexed document II A, of directive 2006/42/CE
Manufacturer name
TECNOEKA Srl
Manufacturer address
Via Marco Polo, 11 - 35010 Borgoricco (PD)
Name of person responsible for technical file
Minotto Lorenzo
Address of person responsible for technical file
Via Marco Polo, 11 - 35010 Borgoricco (PD)
Type of product
Gas oven
Purpose of product
Cooking food
Model
EKF 711G UD – EKF 664G UD - EKF 616G UD
TECNOEKA Srl hereby declares that the above-mentioned products meet all the relevant requirements of the following directives:
Machinery directive 2006/42/CE;
Electromagnetic compatibility directive 2014/30/UE.
TECNOEKA Srl hereby declares that the above-mentioned products meet the requirements of the
following harmonized standards:
EN 60335-1; EN 60335-2-102 EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3; EN 62233
TECNOEKA Srl hereby declares that the above-mentioned products also meet the requirements of the following directives:
Gas Appliances directive 2009/142/CE General product safety directive 2001/95/CE; Restriction of hazardous substances in electrical and electronic equipment (RoHS) directive
2011/65/UE;
Waste electrical and electronic equipment directive 2012/19/UE.
TECNOEKA Srl hereby declares that the above-mentioned products meet the requirements of (CE) Regulation 1907/2006
Borgoricco, 11/08/2016.
_________________________________
Signature of a Representative of the Board of Directors
(Lora Cristina)
X:\Sgq\PRODOTTI\1 - FORNI\FORNO GAS\LEka\MANUALI D'USO - Forno gas - LEka\Lingua Inglese\Linea
EKF\Instruction manual EKF 711G UD - EKF 664G UD - EKF 616G UD - GB - rev. 2.doc
Convection gas oven _ rev. 2__________________________ MODD. EKF 711G UD – EKF 664G UD – EKF 616G UD
_________________________________________________________________________________________ page. 3
Index
1
Descriptions and general warnings
1.1
General warnings
1.2
Data-plate and warning-plate
1.3
Technical specifications
2
General instruction (for installation technician)
2.1
Storage
2.2
Transporting the oven
2.3
Unpacking the oven
2.4
Removing the protective film
2.5
Disposing of the packaging
2.6
Positioning
2.7
Gas connection
2.8
Electrical connection
2.9
Connection to water mains
2.10
Water outlet
2.11
Thermal breaker safety devices
3
Start-up (for installation technician)
3.1
Check of nominal thermal capacity
3.2
Check of connection pressure
3.3
Adaptation to other gas
3.4
Injector replacement and adjustment of primary air
4
User instructions
4.1
General information
4.1.1
Residual risks
4.2
How to use the control panel
4.2.1
Control panel
4.3
First ignition
4.4
Door device
4.5
Cooking techniques
4.5.1
Steam cooking (moist heat)
4.5.2
Convection cooking (dry heat)
4.5.3
Convection + humidity cooking (dry heat + moist heat)
5
Cleaning
5.1
General information
5.2
Cleaning the cooking chamber
5.3
Cleaning the door seal
5.4
Cleaning the door
5.5
Cleaning the external casing
5.6
Periods without use
TECNOEKA Srl _____________________________________________________________ use and instruction manual
page. 4 __________________________________________________________________________________________
6
Maintenance
6.1
General information
6.2
Changing the lighting lamp in the cooking chamber
6.3
Changing the door seal
6.4
Cleaning the fans
6.5
Resetting the thermal breaker safety device
6.6
Possible faults
6.7
Wiring layout
7
TECHNICAL ASSISTANCE AND ORIGINAL SPARE PARTS
7.1
Spare parts list
8
Informations to the consumers
9
The Warranty
10
Availability and supply of spare parts
Convection gas oven _ rev. 2__________________________ MODD. EKF 711G UD – EKF 664G UD – EKF 616G UD
_________________________________________________________________________________________ page. 5
Note 1:
The information provided in this manual are valid only for the oven’s models listed in the cover
and for the country whose initials are therein indicated with the category of membership. For European countries whose initials are present in the data plate on the left side panel (see Fig. 1), the operating instructions will be provided in the official language with functional adaptations to the country (as the additional injector for gas available and its conditions of supply).
Note 2:
These instructions apply only if the EU country code is given on the nameplate of the oven. If the code does not appear, you should refer to the technical instructions which will provide necessary instructions regarding the adaptation of the unit to the conditions of use of other non-EU countries.
Note 3:
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. “
Note 4:
The power cable used must not have lower characteristics than: rubber insulated type H07RN-F with diameter of 3 x 1,5 mm2. If connection to the electrical mains is permanent, a multi-core protective switch of adequate capacity must be installed, with contact opening distance of the overvoltage category III (4000 V).
Note 5:
If the supply cable is damaged then it must be replaced by the manufacturer or by your technical support or by a qualified person to avoid any risk.
Note 6:
The water pressure must be in the range of 100 to 200 kPa (1,0 – 2,0 bar). The appliance is equipped with flexible hose (1.5 metres) with threaded female fittings ¾” and relevant gaskets. Old gaskets must not be reused.
TECNOEKA Srl _____________________________________________________________ use and instruction manual
page. 6 __________________________________________________________________________________________
1. Description and general warnings
The model convector oven bears (EKF616GUD - EKF664GUD - EKF711GUD) an official CE mark, issued by a Notified Body, entrusted with and responsible for evaluating the observance of the essential requirements specified by Gas Directive 2009/142/EC. The oven and the quality of the production system are subjected to regular surveillance by means of inspection checks in order to ascertain their conformity to the type certificate specified by the above mentioned Directive. This appliance may be marketed in all the European countries whose abbreviated reference is present on the technical data-plate. The appliance must be installed to conform with the local laws on the installation of electrical-gas appliance for collective use, and shall include the accessories and functional adaptations required in the destination countries, which are described in the original language in the use and maintenance handbook. The oven has an atmospheric burner and a heat exchanger for heating the cooking compartment. Heat is diffused by an internal two-way fan. The parameters relative to cooking (times, temperatures and climate) you set electronically and appear on the digital display. It is possible to get steam inside the oven chamber. If the burner doesn’t switch on, a red block light: it is possible to restart safely the ingnition of burner through the reset button. If the oven chamber overheats, a safety thermostat blocks the gas delivery and the power to the oven is cut off; it will be possible to switch it on again only manually. The device is located on the rear of the unit.
1.1 General warnings
- If, on receipt of the goods, the packaging is damaged, write the following on the delivery note: “I
REVERSE THE RIGHT TO CONTROL THE GOODS”, specify the damage and get the driver to sign in
acceptance; send a claim in writing to the seller within 4 calendar days from the date of receipt. No claim shall be accepted after such period.
- Read this handbook carefully: it supplies information on safe use, installation and maintenance. The
purpose of this manual is to provide information to operators on the essential prescriptions and criteria to ensure their own safety and prolong the oven’s operating life. This manual must be read by all personnel authorised to work on the machine before it is started up. It must be stored together with the machine for all future consultation. If the manual becomes worn or is mislaid, ask for another copy directly from the manufacturer. These instructions are valid only for countries whose abbreviated reference appears on the cover of this manual and on the data-plate. In European countries where marketing is possible, manuals in the official language shall be provided with specific references to gas, pressures, categories and conditions for the connection. In European countries where marketing is possible, manuals in the official language shall be provided with specific references to gas, pressures, categories and conditions for the connection.
- Maintenance, adaptation to another type of gas, installation, and the functional check must be
performed only by qualified personnel authorised by the manufacturer. Install the appliance in a suitable ventilated room and put it into operation while observing the laws in force. Insist on original spare parts and, after replacing and/or adjusting a part, such as primary air, make sure that it is sealed with paint to prevent any tampering. We advise you to take out a maintenance contract.
- This appliance is designed for cooking or heating foods. Do not use it for other purposes; all other
uses are considered improper. The appliance is intended for collective and professional use and must be utilised by personnel trained to use it.
- Before every oven cleaning or maintenance job, switch off electrical power, and shut off gas and
water supplies.
- This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
N.B.: Improper or incorrect use and failure to observe the installation instructions shall release the manufacturer from all responsibility.
Convection gas oven _ rev. 2__________________________ MODD. EKF 711G UD – EKF 664G UD – EKF 616G UD
_________________________________________________________________________________________ page. 7
1.2 Data-plate and warning-plate The technical data-plate (Fig.1) and the plate with the installation warnings (Fig. 2) are
permanently and visibly fitted on the rear panel of the oven. An additional plate – to be removed with all packing material – is situated inside the packing.
eka
Tecnoeka Srl Via Marco Polo, 11 35010 Borgoricco Padova (Italy )
2015
0705
N° 705CQ297
IT ; G20 ; 2H ; 20 mbar
Mod. Serial Number Qn Type
: XX : 13.50 kW : A1 B11 B21
: EKF 711G UD
G20 G25 G25.1 G2.350 G30 G31
= 1.429 m3/h = 1.661 m3/h = 1.658 m3/h = 1.985 m3/h = 1.065 kg/h = 1.049 kg/h
220-230 V AC 50 Hz 500 W
IPX3
100 ÷ 200 kPa(1.0 ÷ 2.0 bar)
IT-ES-GB-PT-IE-GR-CH-SK-TR-CZ
II2H3+
G20; G30/G31
20; 28-30/37 mbar
DE II2ELL3B/P
G20; G25; G30,G31
20; 20; 50 mbar
LU I2E
G20
20 mbar
AT-CH
II2H3B/P
G20; G30,G31
20; 50 mbar
BE-FR II2E+3+
G20/G25; G30/G31
20/25; 28-30/37 mbar
NL II2L3B/P
G25; G30,G31
25; 28-30 mbar
IS-CY-MT
I3B/P
G30,G31
28-30 mbar
HU 25; 25; 28-30 mbar
PL II2ELs3B/P
G20; G2.350; G30,G31
20; 13; 37 mbar
AL-BA-BG-DK-EE-FI-HR-LT-LV-
II2H3B/P
G20; G30,G31
20; 28-30 mbar
II2HS3B/P G20; G25.1; G30,G31
LU
I3+
G30/G31
28-30/37 mbar
MK-NO-RO-SE-SI-UA
Fig 1
DE
“Dieses Gerat muß nach geltenden Vorschriften angeschlossen und darf nur in einem gut belufteten Raum betrieben
werden. Bitte beachten Sie vor Inbetriebnahme des Gerates die Gebrauchs- und Wartungsanleitung.“
FR
“L’appareil doit être raccordé conformément aux normes en vigueur et il ne doit être installé que dans locaux bien aérés.
Faire attention aux instructions relatives á l’utilisation et l’entretien de l’appareil avant de le mettre en marche.“
ES
“El apparato debe ser conectado conforme a las normas vigentes y se tiene que instalar solo en locales bien aireados.
Prestese especial atencion a las instrucciones para el luso y mantenimiento del apparato antes de ponerlo en marcha.”
GB
“The appliance must be connected according to the standards in force and must be installed only in well aired premises.
It is recommended to follow the use and servicing instructions of the appliance before operating it.”
PT
O aparelho deve ser ligado em conformidade com as normas vigentes e deve ser instalado somente em locais bem
ventilados. Deve-se prestar particular atenção às instruções para o uso e a manutenção do aparelho antes de pô-lo em
funcionamento.
IT
"L'apparecchio deve essere allacciato conformemente alle norme in vigore e deve essere installato solo in locali ben
aerati.
Si presti particolare attenzione alle istruzioni per l'uso e la manutenzione dell'apparecchio prima di metterlo in funzione."
Fig. 2
GB ; G20 ; 20mbar
TECNOEKA Srl _____________________________________________________________ use and instruction manual
page. 8 __________________________________________________________________________________________
1.3 Technical specifications
External overall dimension L x D x H
935 x 980 x 1070 mm
Weight
118 Kg
Nominal thermal capacity
13,50 kW
Tray maximal load GN1/1-600x400mm
4 - 2 kg
Total load GN 1/1-600x400mm
28 - 12 kg
ISO 7-1 gas union
1/2 “
Water union
3/4 “
Fume exhaustion vertical tube
Ø 150 mm; height min. 1000 mm
Appliance category
II2H3+
Factory adjustment
Methane gas G20 , 20 mbar
Type of construction
A1 / B
11
Electrical power
220-230 V ~
Electrical capacity
0,5 kW
Class
I
Power cable type
H07RN-F 3 x 1,5 mm
2
Connecting electric cable
Type Y
Gas connection pressure
Liquid butane/propane gas G30/G31 : 30/37 mbar
Methane gas G20: 20 mbar
Water connection pressure
Max. 200 kPa (2,0 bar)
Gas consumption calculated at low heat value of Hi at
15° and 1013 mbar
G30 : 1,065 kg / h
G20 : 1,429 m3 / h
Parameters to the chimney B11 (Ø 150 mm, L=1 m)
(G20 20 mbar)
fume load
31.45 g/s
fume temperature
163.5 °C
fume pressure
-2.8 Pa
Parameters to the chimney B11 (Ø 150 mm, L=1 m)
(G30 28-30 mbar)
fume load
29.83 g/s
fume temperature
169.2 °C
fume pressure
-2.9 Pa
Main injector diameter
G30/G31 : 190 1/100 mm
G20 : 280 1/100 mm
Primary air bush adjustment
G30/G 31 : 16 mm
G20 : 10 mm
Table 1
The noise level of the appliance in operation is less than 70 dB (A).
2. General instruction (for installation technician)
The installation technician must make sure that start-up conforms to current national regulations. The appliance must be installed only by qualified personnel authorised by the manufacturer. She must observe the safety regulations in force in the country where the appliance is installed. All extraordinary maintenance jobs (possible adaptation to another type of gas or replacement of parts) must be performed by qualified personnel having the necessary professional qualifications. The protected devices and / or sealed by the manufacturer and that are not intended for maintenance, adjustment, or adaptation to change of gas must not be handled either by the installer or user. The seals that must be removed to change the gas must be restored at the end of the adaptation. The manufacturer will not respond for damage to people, animals and property due to installation errors. Likewise the manufacturer is not responsible for breakage caused to the appliance by incorrect installation.
Loading...
+ 16 hidden pages