User’s Manual
Calibration Sensor
Please read this User’s Manual carefully to familiarize yourself with safe and eective usage.
Please retain this manual for future reference.
PRECAUTIONS
WARNING
If the unit begins to emit smoke, smells like something is burning, or makes strange noises,
disconnect all connections immediately and contact your local EIZO representative for advice.
Attempting to use a malfunctioning unit may result in re, electric shock, or equipment damage.
Do not disassemble or modify the unit and cable.
Not doing so may result in damage, re or electric shock.
Package Contents
English
Please contact your local EIZO representative for assistance if any of the listed items are missing
or damaged.
• EX4 (sensor)
• User’s Manual (This manual)
No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any
form or by any means, electronic, mechanical, or otherwise, without the prior written permission
of EIZO Corporation. EIZO Corporation is under no obligation to hold any submitted material or
information condential unless prior arrangements are made pursuant to EIZO Corporation’s
receipt of said information. Although every eort has been made to ensure that this manual
provides up-to-date information, please note that this products specications are subject to
change without notice.
EIZO and EIZO Logo are registered trademarks of EIZO Corporation in Japan and other countries.
ColorNavigator is a trademark of EIZO Corporation.
All other company and product names are trademarks or registered trademarks of their respective owners.
1
Installing the software
This sensor is for the calibration of monitors in the ColorEdge series using color management
software “ColorNavigator 7”. ColorNavigator 7 software needs to be installed to enable use of
EX4. For more information about how to install, see ColorNavigator 7 Installation Guide.
How to attach the EX4
Attention
• Before attaching the EX4, remove the stains or dusts on the surface of the monitor.
Connect the monitor and the PC with the USB cable supplied with
1.
your monitor.
For more information about how to connect, see the Setup Guide for the monitor.
Remove the cap (counterweight) from the sensor.
2.
Counterweight
Sensor
Connect the EX4 to the USB downstream port of either the PC or the
3.
monitor.
2
Suspend the sensor in its measuring position on the monitor by
4.
carefully adjusting the counterweight’s position until both are in
balance.
Counterweight
Counterweight
Slide Slowly
English
3
Specications
Interface USB
Enviromental Specications Temperature Operation: 15 °C – 35 °C
Storage: -10 °C – 60 °C
Humidity Operation: 30 % – 80 % R.H.Non-condensing
Storage: 30 % – 80 % R.H.Non-condensing
Power Supply 5.0 ± 2.5 V max.100 mA
Mass Approx.148 g
Dimensions 79.1 mm (W) × 75.5 mm (H) × 45.7 mm (D)
Certications and Standards CE, FCC-A
Attention
• Take care that the sensor does not suer impact by dropping or other means, or it may aect the
accuracy of the measurement. Storing or using the sensor at a temperature of under 30 °C and a
humidity of under 70% is recommended (avoid storing or using the sensor where it may be exposed
to direct sunlight).
Dimensions
Unit: mm
4
75.51620