EIT LED-R Series, LEDCure User Manual

0
Table of Contents
The Process Values........................................................................................................................................................................................................... 1
Operation and Features ..................................................................................................................................................................................................... 2
Operating the Radiometer ................................................................................................................................................................................................. 3
Setup & Default Modes .................................................................................................................................................................................................... 4
Explanation of Settings: ................................................................................................................................................................................................... 5
Diagnostics & Error Messages ......................................................................................................................................................................................... 6
Low Battery Indicator .................................................................................................................................................................................................. 6
Over-Temperature State ............................................................................................................................................................................................... 6
Over-Range State ......................................................................................................................................................................................................... 6
Other Error Codes ........................................................................................................................................................................................................ 6
Replacing the Batteries ..................................................................................................................................................................................................... 7
Maintenance – Cleaning and Calibration ........................................................................................................................ Error! Bookmark not defined.
Cleaning ...................................................................................................................................................................... Error! Bookmark not defined.
Calibration................................................................................................................................................................... Error! Bookmark not defined.
Warranty and Returns ....................................................................................................................................................................................................... 7
New Product Warranty ................................................................................................................................................................................................. 7
Calibration and Repair Warranty ................................................................................................................................................................................. 8
Returning the Instrument to EIT Instrument Markets ....................................................................................................................................................... 8
Address for Returning All Instruments to EIT-IM ........................................................................................................................................................... 9
Appendix A ...................................................................................................................................................................................................................... 9
Display Cleaning Instructions ...................................................................................................................................................................................... 9
Optics Cleaning Instructions ........................................................................................................................................................................................ 9
Appendix B..................................................................................................................................................................................................................... 10
COM Port Identification and Settings with Keyspan USB Serial Adaptor: ................................................................ Error! Bookmark not defined.
Appendix C...................................................................................................................................................................... Error! Bookmark not defined.
Specifications ............................................................................................................................................................................................................. 10
LED-R Series
LEDCure
User's Manual
1
Introduction
The EIT® LED-R™ Series of instruments is a new family of instruments with optics designed for the measurement of UV LEDs. The instruments build on EIT’s 32+ years of UV measurement experience and previously released products that have bene used to measure broadband UV sources. The first products released are LEDCure Radiometers in Profiling and Non-Profiling (Standard) versions.
The EIT® LED-R™ Series of instruments feature a Total Measured Optics Response. The LEDCure builds and improves on the success of previous EIT radiometers, instruments which are widely used for accurate, repeatable UV measurement of
broadband sources throughout the global UV industry. The LEDCure features selectable sample rates, reference modes and UV irradiance profile graphs. The new instrument is designed specifically to measure UV output from industrial UV LED light sources. As with other EIT products, the instrument is simple to use with easy push-button operation.
The LEDCure is a self-contained, electro-optic radiometer that measures and displays the total UV energy and UV irradiance of a UV LED curing system. The LEDCure combines compact size and robust design to withstand the extremes of UV LED curing environments while providing accurate measurements.
The carefully engineered optical sensing systems only measure LED wavelengths that are relevant to the UV process in the LED band specified. The output of the sensing system is converted to digital form and displayed on an easy-to-read OLED display.
The LEDCure provides measurement from a choice of one of the available EIT wavelength bands designated LXXX, where XXX is the center wavelength of the source to be measured in nanometers (e.g. the LEDCure Model L395 measures 395nm center wavelength LED sources).
EIT Instrument Markets LEDCure is manufactured in the USA. Patent Pending.
The Process Values
The two process values read by the LEDCure are total energy and peak irradiance. The irradiance reading is instantaneous and is the highest amount of UV energy that the unit senses during an exposure run. The irradiance value is energy at one instant in time during the exposure run. The radiometers measure and display irradiance in Watts or milliWatts per square centimeter (W/cm2, mW/cm2).
Total energy density (sometimes referred to as “dose”) is a factor of irradiance over time. The instruments derive this value from the irradiance values during the exposure run and the length of time of the run. Total energy is measured in Joules or milliJoules per square centimeter (J/cm2, mJ/cm2).
Reaching the energy and irradiance values specified by your process is necessary for achieving a complete UV cure.
Ultraviolet Radiation
Although this product is not a source of UV light, it is used in a
UV environment. Refer to the UV source's documentation for
recommended protective measures against UV radiation present
in the UV environment.
2
Identifying Instrument Type
The instrument band, dynamic range and whether the instrument is Profiler enabled can be found in two locations on the instrument
The same information can be found on the instrument display when the instrument is first turn on
Instrument Band: L395
Dynamic Range: 40 W/cm2
Indicates Profiling Enabled
3
Operation and Features: Non-Profiling (Standard) Version
Setup Mode Button
On / Off Button
Depress and Hold until screen is illuminated.
Run / Exit Run Button
Press to enter Run Mode. Press to Exit Run Mode.
Display
Battery Door
Unit Serial Number
Soft Button Operation
Buttons perform the function indicated on the display bottom line.
PC Connector
Alarm
Above: Side view of instrument showing Serial Number, USB port and Alarm
Right: Back of unit showing optics window
Loading...
+ 7 hidden pages