E Instruments BTU1500-Oil User manual

WARNING! - Before proceeding with the combustion analysis remember to set the proper fuel.
7/08/14
10:00
Configuration
Analysis
Operator
Instrument
Alarms
7/08/14
10:00
OK
Configuration Analysis
Fuel
O2 reference
7/08/14
Condensation
Measure units
10:00
OK
Configuration Fuel
Natural gas
Propane
L.P.G.
Butane
Diesel oil
Information
Diagnostic
Autozero
Measures list
Fuel oil
Propane-Air
Language
Combustion analysis
O2
%
CO2
%
Ex. Air
T flue
°F
T air
°F
ΔT
°F
Loss tot
%
Eff. tot
%
Restore
190.1
7/08/14
10:00
4.2
9.3
1.25
15.4
74.7
8.6
91.4
Biogas
7/08/14
10:00
Memory Save
Mode
Memory
Samples
Interval
s
data logger
10
60
1
OK
OK
Combustion analysis
O2
%
CO2
%
Ex. Air
T flue
°F
T air
°F
ΔT
°F
Loss tot
%
Eff. tot
%
7/08/14
10:00
4.2
Automatically
9.3
saves the first
1.25
sample when the
190.1
15.4
74.7
91.4
1
120
set interval
expires, and so on
until the third
8.6
sample.
In case the automatic print mode is set then the average analysis printing start automatically. Conversely, after the sampling of the third analysis, the average analysis is shown, so that it can be sent to the printer as explained in the following.
7/08/14
10:00
Memory Average analysis
O2
%
CO2
%
Ex. Air
T flue
°F
T air
°F
ΔT
°F
Loss tot
%
Eff. tot
%
To view different test measurements, use ' ' key to scroll through the various test measurement screens.
Xair = Excess Air
ΔT = Differential Temperature (NET Temperature)
4.2
9.3
1.25
190.1
15.4
74.7
8.6
91.4
Print Report
Memory
Analysis
Model
OK
7/08/14
10:00
average
partial
Print Report
OK
Memory
Analysis
Model
F1: stop
F1
WARNING
Please wait...
1
Printing.
7/08/14
10:00
In average
partial
Date: 7/08/14 Time: 10.10
Fuel: Natural gas Altitude: 0 m R.H. air: 50 %
1
O2 4.2 ٪ CO2 9.3 ٪ Ex. Air 20 ٪ T flue 374.2 °F T air 60.4 °F ΔT 313.8 °F Loss tot 8.6 ٪ Eff. Tot 91.4 ٪ CO 148 ppm
CO amb 0 ppm Draft: 0.05 inH2O Smoke: 3 1 2
Aver n. : 2
—————————————————————— —————————————————————— —————————————————————— —————————————————————— ——————————————————————
Tg = Flue Gas Stack Temperature Eff. tot = Total Combustion Efficiency
Find Quality Products Online at: sales@GlobalTestSupply.com
Ta = Ambient or Incoming Air Temperature Loss tot = Stack Losses
www.GlobalTestSupply.com
1500
KEYBOARD FUNCTIONS
KEYS FUNCTION
Activate the context keys shown on the display
Enters the Memory menu
Enters the Print menu
Enters the Configuration menu
Previes the combustion analysis
Enters the measurements menu
Turns the instrument on/off
Quits the current screen
Selects and/or modifies
Confirms data
E Instruments respects the nature and the environment, therefore provides this quick user guide to avoid any unwanted waste of paper. However the complete manual for use and maintenance of the instrument is already available in the USB stick (included),. Respect your environment: think before printing the full manual on paper.
Compliant with: EN 50379-1, EN 50379-2
Features
Combustion, Flue gas & Emissions analysis Calculating of stack heat loss and efficiency CO environment measurement Measuring differential pressure Draft measurement Pressure measurement in the gas supply pipe Store Smoke values, calculating mean value
The magnets in the back of the instrument can damage credit cards, hard drives, mechanical watches, pacemakers, defibrillators and other devices proven sensitive to magnetic fields. It is recommended to keep the instrument at a distance of at least 10” away from any of these devices.
CONTEXT KEYS
CONTEXT KEY FUNCTION
O
OK
Esc
ZERO the pressure sensor
Updates the measure
Saves the current measurement or analysis in the memory location selected from the ‘Select Memory’ menu
Starts the report ticket
Enters the Print menu
Stops the flue gas analysis
Enters the modify mode for the selected parameter
Confirms the settings
Cancels the change/operation and returns to the previous screen
Zooms the screen
Shows the details for the selected parameter
‘Find’ function; starts a quick search for
the analysis to recall
COMPLETE MANUAL
ON USB FLASH DRIVE
K000000000EJ 027995 010217
AA AL05
AAC TA03A
AAC KP01
AA SA08
AA SF--A
WARNING!
Be sure all connections are tight to assure accurate sampling. It is important that water trap & filter be installed vertically to
prevent damage from moisture & particles to sensors.
When conducting measurements, the water trap/filter
assembly MUST be in a VERTICAL position.
When testing is completed, always drain the water
trap with any condensation (after EVERY test!).
7/08/14
WARNING! During autozero DO NOT insert the gas probe in the chimney.
KEEP
PRESSED
FOR 2
SECONDS
UNTIL IT
BEEPS
Combustion analysis UNI 10389
O2
%
CO2
%
Ex. Air
T flue
°F
T air
°F
ΔT
°F
Loss tot
%
Eff. tot
%
10:00
4.2
9.3
1.25
190.1
15.4
74.7
8.6
91.4
Find Quality Products Online at: sales@GlobalTestSupply.com
15/01/1
4
Configuration Air temperature
Probe T
Analysis
°C
25.0
Air T
Air temp.
°C
It saves the value, acquired or entered in the parameter
‘Air T’.
15/01/1
4
Configuration Air temperature
Probe T
25.0
°C
Air T
-----
°C
While in manual analysis, holding pressed both keys and makes the instrument switch off the suction fumes pump and blocks the refresh of any current measure. To switch on the suction fumes pump again and reactivate the refresh of the current measure, press again the keys and .
-----
A c q u i r e s t h e temperature value detected from the sampling probe. That value is reported in
the parameter ‘Air T’.
15/01/1
Configuration Air temperature
Probe T
25.0
°C
Air T
25.0
°C
4
www.GlobalTestSupply.com
Draft
P diff
inH2O
O
O
P diff
inH2O
O
P diff
inH2O
O
Measurements Draft
0.001
Measurements Draft
0.000
Measurements Draft
- 0.020
7/08/14
10:00
Before zeroing the
pressure it is mandatory to REMOVE the
probe from the
ZERO Draft
7/08/14
10:00
pressure zeroing
is completed
insert the probe in
the chimney and
measure the draft.
View & Save the
measurement.
7/08/14
10:00
chimney.
Sensor
Once the
DRAFT
It is mandatory to perform the instrument autozero in fresh, clean outdoor air.
7/08/14
10:00
Measurements Ambient CO
CO
Ambient CO
ppm
0
CO max
0
ppm
Connect the gas probe to the instrument and perform
the measurement.
Wait 5 minutes.
7/08/14
Measurements Ambient CO
10:00
Save the
measurement
CO
0
ppm
CO max
0
ppm
K000000000EJ 027995 010217
Loading...