WARNING! - Be fore proceeding with the combustion analysis remember to set th e p r oper fu el.
Configuration
Fuel
7/08/14
1.25
190.1
15.4
74.7
91.4
1
10:00
1
7/08/14
10:00
10:00
4.2
Automatically
9.3
saves the first
sample when the
set interval
expires, and so on
until the third
sample.
8.6
Date: 7/08/14
Time: 10.10
Fuel: Natural gas
Altitude: 0 m
R.H. air: 50 %
O2 4.2 ٪
CO2 9.3 ٪
Ex. Air 20 ٪
T flue 374.2 °F
T air 60.4 °F
ΔT 313.8 °F
Loss tot 8.6 ٪
Eff. Tot 91.4 ٪
CO 148 ppm
CO amb 0 ppm
Draft: 0.05 inH2O
Smoke: 3 1 2
Aver n. : 2
——————————————————————
——————————————————————
——————————————————————
——————————————————————
——————————————————————
7/08/14
10:00
Configuration
Analysis
Operator
Information
Language
Combustion analysis
O2
%
CO2
%
Ex. Air
T flue
°F
T air
°F
ΔT
°F
Loss tot
%
Eff. tot
%
Instrument
Alarms
Diagnostic
Restore
7/08/14
10:00
1.25
190.1
15.4
74.7
91.4
4.2
9.3
8.6
OK
Mode
Memory
Samples
Interval
s
Fuel
reference
O
2
Autozero
Memory
Save
OK
In case the automatic print mode is set then the average analysis printing start automatically.
Conversely, after the sam pling of t he third a nalysis , the avera ge anal ysis is sh own, so t hat it ca n be se nt to the
printer as explained in the following.
Memory
Average analysis
O2
%
CO2
%
Ex. Air
T flue
°F
T air
°F
ΔT
°F
Loss tot
%
Eff. tot
%
x To view different test measurements, use ' ' key to scroll through the various test measurement screens.
Xair = Excess Air
ΔT = Differential Temperature (NET Temperature)
7/08/14
10:00
1.25
190.1
15.4
74.7
91.4
Print
4.2
9.3
Memory
Analysis
Model
Report
average
8.6
OK
Tg = Flue Gas Stack Temperature
Eff. tot = Total Combustion Efficiency
Configuration
Analysis
Condensation
Measure units
Measures list
data logger
7/08/14
10:00
1
partial
7/08/14
OK
10:00
10
60
7/08/14
10:00
1
OK
Memory
Analysis
Model
F1
Natural gas
Propane
OK
L.P.G.
Butane
Diesel oil
Fuel oil
Propane-Air
Biogas
Combustion analysis
O2
%
CO2
%
Ex. Air
T flue
°F
T air
°F
ΔT
°F
Loss tot
%
Eff. tot
%
120
7/08/14
Print
Report
In average
WARNING
partial
Printing.
Please wait...
F1: stop
Ta = Ambient or Incoming Air Temperature
Loss tot = Stack Losses
1500
KEYBOARD FUNCTIONS
KEYS FUNCTION
Activate the context keys shown on
the display
Enters the Memory menu
Enters the Print menu
Enters the Configuration menu
Previes the combustion analysis
Enters the measurements menu
Turns the instrument on/off
Quits the current screen
Selects and/or modifies
Confirms data
E Instruments respects the nature and the environment, therefore provides this quick user guide to
avoid any unwanted wast e of pa p er .
However the complete manual for use and maintenance of the instrument i s already available in
the USB stick (included),.
Respect your environment: think before printing the full manual on paper.
Compliant with: EN 50379-1, EN 50 379-2
Features
x Combustion, Flue gas & Emissions analysis
x Calculating of stack heat loss and efficiency
x CO environment measurement
x Measuring differential pressure
x Draft measurement
x Pressure measurement in the gas supply pipe
x Store Smoke values, calculating mean value
The magnets in the back of the instrument can damage credit
cards, hard drives, mechanical watches, pacemakers,
defibrillators and other devices proven sensitive to magnetic
fields.
It is recommended to keep the instrument at a distance of at
least 10” away from any of thes e dev ices .
CONTEXT KEYS
CONTEXT KEY FUNCTION
O
ZERO the pressure sensor
Updates the measure
Saves the current measurement or
analysis in the memory locatio n selected
from the ‘Select Memory’ menu
Starts the report ticket
Enters the Print menu
Stops the flue gas analysis
Enters the modify mode for the selected
parameter
Confirms the settings
OK
Cancels the change/operation and
Esc
returns to the previous screen
Zooms the screen
Shows the details for the selected
parameter
‘Find’ function; starts a quick s earch for
the analysis to recall
COMPLETE MANUAL
ON USB FLASH DRIVE
K000000000EJ 027995 010217
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com

AA AL05
AAC TA03A
AAC KP01
AA SA08
WARNING!
x Be sure all connections are tight t o assure accurate s ampling.
x It is importan t that water trap & filter be installed vertically to
prevent damage from moisture & particles to sensors.
x When conduc ting measureme nts, the water trap/filter
assembly MUST be in a VERTICAL position.
x When testing is completed, always drain the water
trap with any condensation (after EVERY test!).
WARNING!
During autozero DO NOT
insert the gas probe in the
chimney.
KEEP
PRESSED
FOR 2
SECONDS
UNTIL IT
BEEPS
AA SF--A
Combustion analysis
UNI 10389
O2
%
CO2
%
Ex. Air
T flue
°F
T air
°F
ΔT
°F
Loss tot
%
Eff. tot
%
7/08/14
10:00
1.25
190.1
15.4
74.7
91.4
4.2
9.3
8.6
15/01/1
4
Configuration
Air temperature
Probe T
Analysis
°C
25.0
Air T
Air temp.
It saves the value,
acquired or entered
in the parameter
‘Air T’.
Configuration
Air temperature
°C
15/01/1
Probe T
25.0
°C
Air T
-----
°C
While in manual analysis, holding pressed both keys and
makes the instrument switch off the suction fumes
pump and blocks the refresh of any current measure.
To switch on the suction fumes pump again and reactivate
the refresh of the current measure, press again the keys
and .
-----
4
Acquires the
temperature value
detected from the
sampling probe. That
value is reported in
the parameter ‘Air T’.
Configuration
Air temperature
15/01/1
Probe T
25.0
°C
Air T
25.0
°C
7/08/14
10:00
Measurements
Draft
P diff
Draft
inH2O
0.001
Before zeroing the
pressure it is
mandatory to
REMOVE the
probe from the
chimney.
It is mandatory to perform the
instrument autozero in fresh, clean
outdoor air.
7/08/14
10:00
Measurements
Ambient CO
CO
O
O
Measurements
Draft
P diff
0.000
4
inH2O
7/08/14
10:00
pressure zeroing
is completed
insert the probe in
the chimney and
measure the draft.
ZERO Draft
Sensor
Once the
Ambient CO
ppm
CO max
ppm
Connect the gas probe to the instrument and perform
the measurement.
Wait 5 minutes.
0
0
O
7/08/14
10:00
0
Save the
measurement
P diff
inH2O
Measurements
Draft
- 0.020
7/08/14
10:00
View & Save the
DRAFT
measurement.
CO
ppm
Measurements
Ambient CO
CO max
0
ppm
O
K000000000EJ 027995 010217
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com