Einhell 18V 4-6 Multi-Ah PXC - EX - NA Manual

EN Operating instructions
Battery Pack
Batterie
SP Manual de instrucciones
Paqueta de baterías
Battery Power-X-Change 4.0/6.0 Ah Plus 2P
Batterie Power-X-Change 4,0/6,0 Ah Plus 2P
Lithium-Ion Battery
Batterie au Lithium-Ion
7
Art.-Nr.: 4511904 I.-Nr.: 21010
Anl_Power_X_Change_4_to_6_SPK7_USA.indb 1Anl_Power_X_Change_4_to_6_SPK7_USA.indb 1 28.04.2022 10:26:3128.04.2022 10:26:31
EN
The corresponding safety information / instructions can be found in the safety information and original operating instructions issued for the equipment. Warning! Read all
A
B
Converting the rechargeable battery
The rechargeable battery can be converted between:
- 4511904 (4.0 Ah / 72 Wh) --> low stress for the battery resulting in a total service life which is about three times longer
- 4511905 (6.0 Ah / 108 Wh) --> long running time per battery charge
The rechargeable battery supplied with in 4511904 (4.0 Ah / 72 Wh).
These articles can be converted between each other by entering a code (9-digit chronological key sequence). To do so, proceed as follows:
Important! Read the instructions in full before you start to convert the rechargeable battery!
1. Press the button for the battery charge level indicator (A) and hold it pressed for about 6 seconds until the battery starts counting from 1 to 9 in the display (B). Then let go.
2. - To convert from 4511904 (4.0 Ah / 72 Wh) to 4511905 (6.0 Ah / 108 Wh), press the button (A) briefl y when the fi gure 6 is shown. After this, counting continues as normal up to 9. (Code: 0 0 0 0 0 1 0 0 0)
- To switch over from 4511905 (6.0 Ah / 108 Wh) to 4511904 (4.0 Ah / 72 Wh), press the button (A) briefl y when the fi gure 4 is shown. After this, counting continues as normal up to 9. (Code: 0 0 0 1 0 0 0 0 0)
3. Once the sequence has counted up to 9 in the display (B), the capacity of the converted article will be shown as “6Ah” or “4Ah” for about 2 seconds.
The rechargeable battery has now been converted.
Important! Conversion only takes place if the button (A) is pressed precisely when the digit 4 or 6 appears. This operation is necessary in order to prevent unintended conversion. After conversion, the rechargeable battery is a diff erent device with a diff erent article number. The new specifi cations label can be obtained by going to www.einhell.com.
Important! For the Lithium-Ion battery to be allowed to be sent or transported in accordance with special provision 188, it must be converted to 4511904 (4.0 Ah / 72 Wh)! Defective Lithium-Ion batteries are not allowed to be sent normally! In this connection, contact King Canada Tools Inc. Dorval, Quebec · H9P 2Y4 · CA, www.einhell.com
ACTIVE BATTERY MANAGEMENT SYSTEM
The computer-assisted Active Battery Management System permanently monitors and controls all the safety­related processes of the electrical components and associated hardware. This results in a whole range of advantages:
MAXIMIZED RUNNING TIMES
OPTIMIZED TOOL POWER
LONGER BATTERY SERVICE LIFE
MORE SAFETY
Battery charge level indicator
Press the button for the battery charge level indicator (A) briefl y. The display for the battery charge level indicator (B) fi rst shows you the charge level in % and the current capacity in succession for 2 seconds each.
the safety information and instructions carefully!
Description
A - Button for battery charge level indicator B - Display for battery charge level indicator
- 2 -
Anl_Power_X_Change_4_to_6_SPK7_USA.indb 2Anl_Power_X_Change_4_to_6_SPK7_USA.indb 2 28.04.2022 10:26:3228.04.2022 10:26:32
EN
Important! The charge level adjusts accordingly after conversion to 4511904 (4.0 Ah / 72 Wh) or 4511905 (6.0 Ah / 108 Wh) and may vary from that of the previous article. If, for example, the rechargeable battery in 4511904 (4.0 Ah / 72 Wh) had a charge level of 100% and it is converted to 4511905 (6.0 Ah / 108 Wh), the charge level then will be well below 100%. You therefore need to charge up the battery before doing anything else.
Error codes
Code Cause Remedy
F01 The rechargeable battery is too hot (e.g.
due to direct sunshine).
F02 The rechargeable battery is too cold. Keep it at room temperature (approx. 68°F (20°C)) for
F03 The rechargeable battery is over-loaded. Remove the battery from the equipment and try again.
F04 The rechargeable battery is defective. A defective battery is not allowed to be used any more.
F05 The rechargeable battery has undergone
partial exhaustive discharge.
Keep it at room temperature (approx. 68°F (20°C)) for one day.
one day.
No change: See F01.
Recharge the battery.
- 3 -
Anl_Power_X_Change_4_to_6_SPK7_USA.indb 3Anl_Power_X_Change_4_to_6_SPK7_USA.indb 3 28.04.2022 10:26:3328.04.2022 10:26:33
Loading...
+ 5 hidden pages