Eilon Engineering RON 2501 Operating Manual

This document courtesy of:
Data Weighing Systems, Inc.
Contact Us
For immediate assistance call
1-800-750-6842
OPERATING MANUAL
RON 2501
WIRELESS MULTI-FUNCTION
CRANE SCALE / DYNAMOMETER
The multi load cell version
18.10.06 n.g.
Eilon Engineering Ltd. RON 2501 NG Operating Manual 2
CONTENTS
GENERAL CAUTIONS AND WARNINGS
3
WARRANTY 6
1. GENERAL DESCRIPTION 7
2. BATTERY CARE AND MAINTENANCE 8
3. OPERATION 10
4. TARE 11
5. MAX. (=PEAK HOLD)
11
6. OVERLOAD WARNINGS 12
7. CALIBRATION 12
8. OPTIONS 14
8.1 SET POINTS – ADJUSTING & GENERAL SCHEME 14
8.2 UNITS - SELECTING 15
8.3 TIME - ADJUSTING 16
8.4 RS-232 COMMUNICATION DATA 16
8.5 PRINT – MODE, SELECTION 17
8.6 BAUD RATE SELECTION 18
8.7 TOTALIZER 18
8.8 DATA LOGGER 19
8.9 CONNECTING CABLES 20
8.9.1 SEALED, ROUND 5-PIN CONNECTOR 20
8.9.2 SEALED, ROUND 3-PIN CONNECTOR 20
8.10 THE HOT INDUSTRY VERSION 20
8.11 CONTINUOUS MAX. DISPLAY 22
8.12 DAMPENED READINGS – IF APPLICABLE 23
8.13 MULTI-LOAD CELL WITH ONE SUMMING-UP
INDICATOR 24
8.13.1 “CLOSING” LOAD CELLS 24
8.13.2 CALIBRATION 25
9. ERROR TABLE 26
10. TROUBLESHOOTING 27
Eilon Engineering Ltd. RON 2501 NG Operating Manual 3
GENERAL CAUTIONS AND WARNINGS
THE CAUTIONS AND WARNINGS, SYSTEM SPECIFICATIONS AND USER INSTRUCTION SHEETS SHOULD BE READ CAREFULLY BEFORE ATTEMPTING TO USE THIS EILON ENGINEERING PRODUCT.
Products are supplied with the express understanding that the purchaser and/or the user are thoroughly familiar with their correct application and proper use. Eilon Engineering will assume no responsibility for the misuse or misapplication of any of its products.
In addition to these guidelines, the user must also comply with general safe operating practice, and when using the systems for weighing during lifting, the user must also comply with safe operating practice during lifting.
The load limit rating (or “capacity”) indicates the maximum force or load a system can carry under normal working conditions. Overloading, or placing a load on the system above its rated capacity is dangerous and is therefore STRICTLY PROHIBITED, except during annual safety testing of the system, to be performed by qualified personnel, when overload of up to 25% of rated capacity is permitted.
Eilon Engineering will accept no liability for damage caused by the product being used in excess of the working load limit (capacity of the system) or from abuse.
Opening or attempting to open the systems and, needless to say, any attempt to repair the systems by unauthorised personnel (without written authorisation) will nullify the warranty as well as the manufacturer's liability, and could be dangerous.
When measuring loads using shifted zero or tare, the actual loading is the indicated value (the readout) plus the value of the shifted zero or tare.
The system is designed for occasional, not continuous, use. If the system is to be integrated with equipment that performs continuous loading over extensive periods of time, then use of a system with at least 30% higher rated capacity (load limit) is necessary. For example: a 3t crane should be used with a 5t load system.
The system is designed for static loading. Eilon Engineering or other qualified engineering personnel should be consulted before using the system to measure dynamic loads.
Avoid bending, side loading and off-axis loading.
Eilon Engineering Ltd. RON 2501 NG Operating Manual 4
When connecting the load cell in order to measure forces or loads, special care should be taken to choose the right connecting accessories that will permit free movement and prevent bending moments in the load cell.
Use shackles with S.W.L. (Safe Working Load) equal to, or greater than the system's maximum capacity.
Check the system thoroughly before use, including the lifting accessories which are included in some of the RON systems. Do not use a damaged system.
We recommend that the systems be checked occasionally by lifting a known weight.
We recommend that the systems be sent back to the manufacturer for general examination once every year.
Do not use the system with an unknown load if there is any doubt as to the reliability of the load indication. To check its reliability, use only a known load with a value of more than 50% and less than 100% of the system’s rated capacity (load limit).
The permitted temperature range appears in the RON systems specification. Do not allow the systems to overheat. This could be dangerous.
Take particular care not to expose the system to nuclear radiation. Local environmental conditions such as extreme temperatures, radio transmissions or other magnetic radiation may interfere with reliable system operation and may cause a false (low) reading which could prove dangerous. Avoid using the system under such conditions. The system is not explosion-proof and should not be used in hazardous areas.
System calibration should be performed annually, in an authorized laboratory, unless laws, regulations, or other policies specify other intervals for calibration.
Between calibrations, the user can verify whether the systems are still calibrated correctly by using a known weight.
Calibration verification and adjustment must be performed with extreme care since a wrong calibration adjustment will result in false readings, which could be dangerous.
Eilon Engineering Ltd. RON 2501 NG Operating Manual 5
Unless otherwise specified, Eilon Engineering products are not legal for trade.
Each system consists of a load cell with its own indicator. Important
: If you own several systems, make sure that each load cell is used with its original indicator. Load cells and indicators are calibrated as matched pairs and are non-interchangeable.
At all times, it is the responsibility of the user of this equipment to ensure that normal safety precautions are observed. No amount of safety features and engineering can be a substitute for common sense and a desire to work safely.
Eilon Engineering Ltd. RON 2501 NG Operating Manual 6
EILON ENGINEERING LTD.
LIMITED WARRANTY
Eilon Engineering Ltd. load meters and overload detectors are built in accordance with listed specifications. Eilon Engineering Ltd. also guarantees that all its products are thoroughly inspected and performance tested prior to shipment.
If any appropriately maintained part proves to have been originally defective in materials or workmanship within the Warranty Period explicitly stated in the Eilon Engineering Ltd. literature that accompanied the product, Eilon Engineering Ltd. will replace or repair the part at no charge, or refund the price paid for such product, all at the sole discretion of Eilon Engineering Ltd.
This warranty policy specifically excludes transportation costs.
The warranty shall be null and void if any repair or modification is performed on
the system, or if any attempt has been made to open any part of the system, by
any parties other than those specifically authorised by Eilon Engineering Ltd.
Batteries are not covered by this warranty.
Eilon Engineering Ltd. reserve the right to change materials or design when, in its opinion, such changes will improve its product.
These warranties exclude all other warranties, express or implied.
Eilon Engineering Ltd. will not, in any event, be liable for incidental or consequential damages.
The distributor is solely responsible for ensuring that this warranty is delivered to his sub-distributors and their ultimate customers or users.
Eilon Engineering Ltd. RON 2501 NG Operating Manual 7
1. GENERAL DESCRIPTION:
RON 2501 is available either as a Shackle or Hook Type.
RON 2501 Shackle Type is a Dynamometer with remote wireless display.
RON 2501 Hook Type is a Crane Scale with remote wireless display.
The RON 2501 consists of a Load Cell and an Indicator. These two items are
designed to work together.
The indicator is held by the user, so that under no circumstances will he have to approach the load in order to read the result. By this means, his personal safety is ensured.
Communication between the load cell and the indicator is wireless. The effective transmission range is 50m under normal working conditions. This feature enables the system to be used in hot industries and in circumstances where using a cable is not possible, or is inconvenient.
The load cell panel includes an ON/OFF button. When the load cell is
functioning correctly the red light on the panel flashes briefly at approximately 5
sec. intervals.
The indicator includes a control panel and a display. The standard control panel has six push-buttons to operate and program the system. It also includes the hidden key “ESC”.
Each standard system offers these push-button features: On/Off Zero Tare (100% of capacity) MAX (=Peak hold) User calibration
The 5-digit display provides the following information:
* The measured load * Two level overload warning * Max. value (= Peak hold) * Low battery warning for both load cell and indicator * The following modes: SLEEP, TARE, NET * The units in use (Lbs, Kgs, etc.) * Instructions during programming procedure etc.
Eilon Engineering Ltd. RON 2501 NG Operating Manual 8
The RON 2501 is available calibrated in lbs, kgs, metric tons, short tons, newtons, deca-newtons or kilo newtons.
RON 2501 options include:
1) * Digital RS-232 output for communication with computer, printers etc.
user-selectable; continuous data flow or print on demand.
2) * User-selectable baud rate.
3) * User-adjustable set points.
4) * User-selectable units.
5) * Additional remote wireless display/s, similar to the main one.
6) * Additional remote display 2" (50mm) LCD with cable.
7) * Totalizer, for totaling up accumulated loads.
8) * Data logging: stores data and time, up to 600 load measurements, with print
capability.
9) * Data logger with extended memory capacity for storing up to 3000 load
measurements.
10) * Rechargeable batteries (instead of disposable) and a charger to charge the
batteries inside the system.
11) * Specially fitted carrying case.
12) * High accuracy 0.05% of full range + 1 resolution step and imported
resolution (50% of standard).
13) * Indicator belt clip (for hanging the indicator on a belt).
14) * Heat shield for hot industries.
15) * Clock – real time clock.
2. BATTERY CARE AND MAINTENANCE
The standard system is equipped with disposable 1.5V (“finger”) type Alkaline batteries fixed in special battery racks. The load cell contains 4 and the indicator 3. The battery rack is located in the lower part of the indicator.
To replace batteries, press the two small latches on both sides of the lower part of the indicator. The battery rack is just behind the lower indicator box cover that is released by the two latches. The load cell batteries can be replaced by opening the four Philips screws securing the body cover – the one without the antenna.
Use high quality, high energy Alkaline 1.5V AA size batteries.
Loading...
+ 20 hidden pages