Eiki AH-51401, AH-45401 User Manual

WARNING: This installation manual is for use by service personnel. Please be aware that the
Installation Manual
AH-45201 AH-45301 AH-45401
(Only for EIP-4500L)
AH-51401
(Only for EIP-5000L)
AH-45501 AH-45601 AH-45701
manufacturer cannot be responsible for breakage or damage incurred due to improper installation of this lens or use of the projector.
When replacing the lens, please have the lens replaced by the store of purchase or an EIKI Engineering certified service workshop. The inside of the projector contains high­voltage parts that can be extremely dangerous. Never attempt to replace the lens by yourself.
Always make sure to turn off the main power and unplug the power cord before replacing the lens.
Be careful not to allow any screws to drop inside the projector while working. This can cause a fire, electrical shock or malfunction.
Do not attempt to replace the lens while the projector is suspended from the ceiling. The lens may fall out of the projector resulting in injury.
Before replacing the lens, return the lens shift to the position shown below. (The lens shift is adjusted to the position shown below when shipped from the factory.)
••
V (vertical) shift: Uppermost position
••
••
H (horizontal) shift: Middle position
••
When replacing the lens, use a commercially available screwdriver that satisfies all of the conditions indicated below.
Type 2 Philips head screwdriver
Length of protruding section: min. 180 mm (10")
Magnetized
12
Loosen the lamp replacement
screw (
11
1) that fastens the lamp
11
unit cover, and remove the lamp
unit cover by sliding in the direc-
tion shown by the arrow (
Lamp unit cover
2
22
2).
22
Lamp replacement screw
1
Remove the mounting screws of
the top cover.
Top cover
Mounting screws
345 6
Unplug the cable connector (
and remove the top cover (
1
Cable connector
AH51401_Inst_Manual_E.p65 06.12.27, 11:54 AM1
(When the lens being removed is the AH-45401 (EIP-4500 standard lens) or AH-51401 (EIP-5000 standard lens))
Remove the lens ring by turning
Unplug the cable connector.
22
2).
22
11
1)
11
Release the tabs while pulling up
on the lens cover, and then pull
it out towards you.
in the direction shown by the ar-
row.
2
Tabs
Lens cover
Cable connector
7
8
9
10
Remove the lens mounting
screws.
Lens mounting screws
Rotate the replacement lens 90 degrees in the direction shown by the arrow (
11
1), align the posi-
11
tioning pin with the guide hole, tighten the lens mounting screws ( cable connector (
3
22
2) and then connect the
22
33
3).
33
Cable connector
Positioning pin
Guide hole
1
Pull out the lens towards you and
then take out the lens (
tating it 90 degrees (
22
2) by ro-
22
11
1) in the di-
11
rection shown by the arrow.
1
2
1211
(When the lens being attached is the AH-45401 (EIP-4500 standard lens) or AH-51401 (EIP-5000 standard lens))
Attach the lens ring.
Align the a mark on the lens ring with the positioning pin on the lens (silver pin), in­sert the lens ring all the way to the back and then rotate in the direction of the ar­row.
Positioning pin
Remove the lens cap (on the
back) from the replacement lens.
This explanation uses the example of the AH-45201.
Positioning pin
Lens cap (back)
Insert the replacement lens into
the lens mount with the motor
section facing up.
Motor section
13 14
Attach the lens cover.
Insert the lens cover while spreading apart the ring section (made of rubber), and then attach the tabs to the ribs.
Ribs
Tabs
Connect the cable connector by
following steps 1 through 3, and
then attach the top cover and
lamp unit cover.
The power of the projector will not come on unless the lamp unit cover is securely attached.
Lens mount
2
AH51401_Inst_Manual_E.p65 06.12.27, 11:54 AM2
a
mark
Lens cover
Printed in China
9NK5010060800
07P03-CH-NM