Ei Electronics Ei 3105TYCH Optical Product Manual

Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053 Email. eielectronics@eiltd.ie Web: www.eielectronics.com
Model Ei 3105TYCH Optical
High sensitivity – responds to all standard fires Senses smoke using the light scatter principle,
giving a quick response to visible smouldering fires
Lithium 10 year battery to provide long lasting life Interconnect up to 12 other alarms with silencer
capability
Low battery warning Built in sounder Test/Hush button Kitemarked to BS EN 14604:2005 5 year guarantee
Product Description
The Ei3105TYCH is an Optical Smoke Alarm that runs on a 9V 10 year lithium battery to provide a long lasting life (supplied with the alarm).
The Ei3105TYCH is easily installed and comes supplied with all necessary screw fixings.
The Ei3105TYCH particularly useful near kitchens as the hush button will silence nuisance alarms from cooking etc for 10 minutes.
Operation
The smoke detector will activate the built in sounder
upon sensing smoke particles
The smoke detector will automatically reset itself
and silence the sounder when smoke particles are no longer present in the sensing chamber
The built in sounder will provide a minimum sound
output of 85dB at 3m
The “Hush/Test” button will simulate smoke-use to
check performance at least monthly
The “Hush/Test” button will silence nuisance alarms The smoke detector will emit a beep every 40
seconds to indicate that the battery back up is depleted and needs replacing
9V LITHIUM BATTERY
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053 Email. eielectronics@eiltd.ie Web: www.eielectronics.com
Model Ei3105TYCH Smoke Alarm
Installation & Placement
Alarms should be placed in accordance with the general guidelines shown in the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector Please consult the Instruction Leaflet supplied with the Ei3105TYCH for
detailed instructions as to how to correctly install and position the smoke detector
Important Precaution:
Do not install the actual smoke/heat alarm itself in new or renovated buildings until all work is completed (including floor coverings) and the building has been fully cleaned. (Excessive dust and debris from building work can contaminate the smoke chamber and cause problems, and it will also invalidate the guarantee). If it must be installed, cover it completely, particularly around the edges, with a dust cover (eg. a plastic bag), until all cleaning is finished..
Technical Specification
Sensor: Optical, uses light scatter from
smoke particles
Sensitivity: Complies with BS 5446 Part 1:
2000
Source: Contains no radioactive material
Airspeed: Essentially immune to the effect
of airspeed.
Button Test: Simulates the effect of smoke and
checks chamber, electronics and horn
Supply Voltage: 9V lithium battery
Alarm: Piezoelectric horn
in unit
Alarm Sound Output: 85dB (minimum) at 3m
Temperature Range: 0 to 40°C
Humidity Range: 0% to 90% Relative Humidity
Fixing: Screw fixings supplied
Plastic material: UL94HB flame retardant Dimensions: 140x 120x 45 Weight: 281 g Warranty: 5 year (limited) warranty Approvals: Kitemarked to BS EN 14604:2005,
CE Approved
Specifications are subject to change
Loading...