Ei Electronics Ei3105RF User Manual

Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053 Email. eielectronics@eiltd.ie Web: www.eielectronics.com
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. Ei3105RF DataSht RevB
RF wireless interconnect Unique house coding feature Visual RF transmission indicator High performance optical chamber with integral
insect screen
Test button Advanced suppression and calibration technology Radio transmitter and receiver in each alarm Built in auto self test feature Low power cell warning Kitemarked to BS EN 14604:2005 5 year guarantee
Product Description
The Ei3105RF is an Optical Smoke Alarm that runs on 9V alkaline battery and is part of the Radio Frequency range of smoke alarms. The RF signal will wirelessly interconnect the Ei3105RF to other RadioLINK products
The Ei3105RF uses advanced radio transceiver technology with unique software coding to transmit and receive the radio signals. The transmissions are frequency modulated (FM) and use Manchester coding to ensure robust signal integrity and avoid signal noise interference
The Ei3105RF has other advanced features such as high performance optical chambers fitted with integral insect screens to reduce the chances of false alarms, as well as the ability to wireless interconnect up to twelve alarms to allow all alarms to sound if just one of the interconnected alarms should be triggered.
The Ei3105RF has built in circuitry to aid suppression of voltage transients and RF interference to further reduce the chances of false alarms under such conditions
Operation
The red indicator will flash every 40 seconds to show that
the detector has performed an automatic self test
In normal standby mode the amber indicator will light to
indicate transmission of an RF signal
In code mode, the amber indicator will flash to indicate the
number of other RF alarms that have been “learned” in the
system
The red indicator will flash rapidly to show an alarm
condition for the smoke detector
The “Test/Hush” button will either silence false alarms or
perform a unit self test
In “Hush” mode the alarm enters a ten minute period of
reduced sensitivity and the red light flashes every 10 seconds and then resets
When interconnected to other Ei mains powered alarms, an
alarm on one detector will trigger all other interconnected alarms within one second (only the triggered alarm will flash a red indicator)
The smoke detector will emit a beep and the red light
flashes every 40 seconds to indicate that the battery is depleted and needs to be changed
BATTERY POWERED 9V
RF Communication
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053 Email. eielectronics@eiltd.ie Web: www.eielectronics.com
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. Ei3105RF DataSht RevB
Model Ei3105RF Optical
Installation & Placement
Place the alarm on the ceiling/wall and mark the screw holes. Drill with a suitable drill bit, insert the screw plugs and screw the alarm into position. Simply connect the battery on the alarm and slide into position on the mounting plate.
The RF alarms should be house coded to prevent possible interference from neighbouring installations – see instructions for more details.
Alarms should be placed in accordance with the general guidelines shown in the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector
House Code Procedure
1. Connect the battery
2. Press the house code switch until the amber light turns on and then release
3. Similarly, place other alarms into house code mode
4. Check that the number of amber flashes (on each alarm) corresponds to the number of alarms in your system
5. Remove all alarms from house code
6. Button test each alarm to check your system
Technical Specification
Sensor Optical, uses light scatter from
smoke
Sensitivity: Complies with BS 5446 Part 1:
2000
Automatic Self-Test: Smoke Chamber is tested every 40 Sec. and unit beeps (without LED flash) if it is degraded.
Supply Voltage: 9V alkaline battery RF Range: 150 meters (min) free space RF Visual Indicator: Amber light flashes continuously
for 1.5 to 3.5 seconds while transmitting RF signal
RF Frequency: 868.499MHZ (1% duty cycle) RF Power: +5dBM Dimensions: 140mm x 120mm x 45mm Weight: 220g
Power-On Indicator: Red light flashes every 40 seconds Alarm: Electronic Piezoelectric horn Alarm Sound Output: 85dB (minimum) at 3m Alarm Status: Red LED flashes every second on
unit sensing fire
Temperature Range: 00 to 400 C Humidity Range: 15% to 95% Relative Humidity Interconnect: Up to 12 RadioLINK products Plastic material: UL94HB flame retardant Warranty: 5 year (limited) warranty Approvals: Kitemarked to BS EN 14604: 2005,
CE Approved