• High sensitivity – responds to all standard fires
• Senses smoke using the light scatter principle,
giving a quick response to visible smouldering
fires
• Battery powered – 9V alkaline (supplied)
• Missing battery indicator
• Low battery warning
• Built in sounder
• No wiring
• Test/Hush button
• Kitemarked to BS5446-1:2000
• 5 year guarantee
Product Description
The Ei3105H is an Optical Smoke Alarm that runs on a
9V alkaline battery (supplied with the alarm).
The Ei3105H is easily installed and comes supplied with
all necessary screw fixings.
The Ei3105H particularly useful near kitchens as the
hush button will silence nuisance alarms from cooking
etc for 10 minutes.
Operation
• The smoke detector will activate the built in sounder
upon sensing smoke particles
• The smoke detector will automatically reset itself
and silence the sounder when smoke particles are
no longer present in the sensing chamber
• The smoke detector has a built in warning flag to
prevent installation of the detector without a battery
fitted
• The built in sounder will provide a minimum sound
output of 85dB at 3m
• The “Test/Hush” button will simulate smoke-use to
check performance at least monthly
• The “Test/Hush” button will silence nuisance alarms
• The smoke detector will emit a beep every 40
seconds to indicate that the battery back up is
depleted and needs replacing
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. eielectronics@eiltd.ie
www.eielectronics.com
Model Ei3105H Smoke Alarm
Installation & Placement
Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector
Please consult the Instruction Leaflet supplied with the Ei3105H for detailed
instructions as to how to correctly install and position the smoke detector
Important Precaution:
Do not install the actual smoke/heat
alarm itself in new or renovated
buildings until all work is completed
(including floor coverings) and the
building has been fully cleaned.
(Excessive dust and debris from
building work can contaminate the
smoke chamber and cause
problems, and it will also invalidate
the guarantee). If it must be
installed, cover it completely,
particularly around the edges, with
a dust cover (eg. a plastic bag),
until all cleaning is finished..
Technical Specification
Sensor: Optical, uses light scatter from
smoke particles
Sensitivity: Complies with BS 5446 Part 1:
2000
Source: Contains no radioactive material
Airspeed: Essentially immune to the effect
of airspeed.
Button Test: Simulates the effect of smoke and
checks chamber, electronics and
horn
Supply Voltage: 9V battery
Alarm: Piezoelectric horn
in unit
Alarm Sound Output: 85dB (minimum) at 3m
Temperature Range: 0 to 40°C
Humidity Range: 0% to 90% Relative Humidity
Fixing: Screw fixings supplied
Plastic material: UL94HB flame retardant
Dimensions: 140x120x45 mm
Weight: 281 g
Warranty: 5 year (limited) warranty
Approvals: Kitemarked to BS5446-1:2000, CE
Approved
Specifications are subject to change
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. eielectronics@eiltd.ie
www.eielectronics.com