Ei Electronics Ei2110 User Manual

Model Ei2110
Multiple sensor elements – optical and heat Better response to all fire types than single sensor
devices.
MAINS POWERED 230V~
Remote Control Capability & Rechargeable Battery Back-Up
Multi-Sensor Alarm
Product Description
The Ei2110 is a Multi-Sensor Fire Alarm that contains two separate sensing elements – optical and heat. Using i-fire® intelligence to monitor two different byproducts of fire, its response to all fire types is vastly improved over traditional single sensor
alarms. It’s ability to respond quickly to both fast flaming and
smoldering fires, simplifies alarm choice for the designated rooms / areas.
The new sensor chamber design, i-fire® intelligence and the unique dust compensation feature, combine to reduce the frequency of nuisance alarms.
The dust compensation automatically adjusts for any contamination within the optical sensor chamber, resulting in increased longevity and robustness.
The Ei2110 runs on 230V AC mains power. In the event of mains failure, the 10 Year+ built in tamper-proof rechargeable Lithium cells will provide back-up supply and continuous operation.
The E2110 also has hardwired Remote Control capability, enabling it to be interconnected to and communicate with compatible Ei smoke/heat alarms and accessories. Up to twelve alarms can be interconnected, which will cause all alarms to sound when one unit senses fire.
The Ei2110 is supplied with an easi-fit base that allows quick and simple installation of the alarm, combined with simple alarm head removal and replacement.
Connecting the Ei2110 to an Ei168RC easi-fit RadioLINK base enables the remote control functionality to be performed wirelessly, eliminating the need for hard wired interconnections.
Operation
The green indicator will illuminate to show mains power is
present and the device is in standby mode.
On receipt of a fire alarm signal the red LED will flash rapidly
and the horn alarm will turn on. When the alarm has been cleared the device will remember the event and the red LED will emit two slow flashes every 40 sec for 24 hours.
When the Ei2110 receives an external fire signal from another
smoke/heat/multi-sensor device via interconnect or RadioLINK the horn alarm will turn on.
Pressing and holding the “Test/Hush” button while the device
is in standby state, will perform a test on the alarm. This checks the sensors, electronics and sounder.
Pressing and holding the “Test/Hush” button on a device that
has alarmed in past 24 hours, will cause the alarm to emit short beeps. This can aid in identifying the unit that has previously triggered the entire alarm system.
Pressing and releasing the “Test/Hush” button when the
device is in alarm will silence the unit by reducing its sensitivity. The unit will automatically reset after 10 minutes
When hardwired or RadioLINK interconnected to other Ei
mains powered alarms, an alarm on one device will trigger all other interconnected alarms (only the triggered alarm will have a rapidly flashing red indicator)
When a low back-up battery condition is sensed, the device
will emit a single beep and red LED flash every 40 seconds.
The Amber Led will flash once every 40 seconds, to indicate a
device fault condition.
E & OE. As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. Ei2110 RevB
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Phone.+353 (0)61 471277 Fax.+353 (0)61 471053 E-mail. eielectronics@eiltd.ie Web. www.eielectronics.com
Model Ei2110
E & OE. As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. Ei2110 RevB
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Phone.+353 (0)61 471277 Fax.+353 (0)61 471053 E-mail. eielectronics@eiltd.ie Web. www.eielectronics.com
Technical Specification
Supply Voltage: 230V AC Mains Power Supply.
Battery back-up: Built-in 10 Year tamperproof
rechargeable Lithium cells.
Power-On Indicator: Continuous Green LED when
mains connected.
Alarm sounder: Electronic Piezoelectric horn Alarm Indicator: Red LED will flash twice per
second.
Memory Indicator: Red LED will flash twice every
40 seconds to indicate the device has been in alarm state in the last 24 hrs.
Fault Indicator: Amber LED flashes once every
40 seconds to indicate excessive smoke chamber contamination.
Amber LED flashes once every
40 seconds with an audible beep to indicate a sensor fault.
Low battery: Red LED will flash once every 40
seconds simultaneously with a horn beep
Temperature Range: 0°C to 40°C Humidity Range: 0% to 90% Relative Humidity Interconnect: A combination up to 12 devices
can be interconnected. These devices include Ei2110 Multi­Sensor Fire alarms, Ei160 RC Series Smoke & Heat alarms Ei261 series CO alarms*. In addition the following accessories may be interconnected e.g. Ei168RC RadioLINK base, Ei1529RC control switch and EI128R relay base. *Note: we recommend that a control switch be fitted when interconnecting CO alarms with Smoke and fire alarms.
Optional Controls: Ei1529RC Control Switch
MCP401RC Manual Call Point
Fixing: Easi-fit mounting base
Plastic material: UL94VO flame retardant Dimensions: 152mm diameter x 50mm
depth
Weight: 320g Warranty: 5 year (limited) warranty